Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Future Sci OA ; 10(1): FSO956, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827803

RESUMEN

Aim: This systematic review aims to consolidate findings from current clinical trials that compare the effectiveness of insulin infusion at 0.05 IU/kg/h versus 0.1 IU/kg/h in managing pediatric diabetic ketoacidosis. Methods: We searched several databases, including PubMed, Embase, Scopus, Cochrane Central and Web of Science. Our primary outcomes were time to reach blood glucose ≤250 mg/dl and time to resolution of acidosis. Secondary outcomes included rate of blood glucose decrease per hour, incidence of hypoglycemia, hypokalemia, treatment failure, and cerebral edema. Results & conclusion: The present study establishes that a low insulin dose exhibits comparable efficacy to the standard dosage for managing pediatric patients suffering from diabetic ketoacidosis, with a lower incidence of complications.


When kids with type 1 Diabetes (T1DM) face a serious complication called Diabetic Ketoacidosis (DKA), it becomes a life-threatening situation. This condition, responsible for significant mortality, involves high blood sugar, ketone buildup and acidity. Our study delves into a critical aspect of DKA treatment-finding the right insulin dose. By pooling the studies on this point, we discovered that using a lower insulin dose is just as effective as the standard dose in managing DKA in children, with fewer complications. This insight is crucial for improving the care and outcomes for young patients dealing with this challenging condition.

2.
Front Microbiol ; 15: 1385834, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38646637

RESUMEN

Background: The Vi-diphtheria toxoid typhoid conjugate vaccine (Vi-DT) has shown promising results in preventing typhoid fever in children under 2 years of age. However, a thorough assessment of its safety and immunogenicity is required to inform vaccination strategies. This systematic review and meta-analysis aimed to determine the safety and immunogenicity of Vi-DT in children below 2 years. Methods: We systematically searched multiple databases, including PubMed, Web of Science, and Scopus, for relevant studies published up to September 2023. We included studies reporting on the safety and immunogenicity outcomes of Vi-DT compared to the control or Vi-tetanus toxoid conjugated vaccine (Vi-TT) in children below 2 years. We applied a random-effects model for meta-analysis using RevMan 5.4. We expressed the results as risk ratio (RR) with a 95% confidence interval (95%CI). Results: In this analysis, five studies were selected, encompassing 1,292 children under 2 years who received the Vi-DT vaccine. No significant difference in immediate reactions was observed within 30 min post-vaccination between Vi-DT and control groups (RR: 0.99 [95% CI: 0.19, 5.26]), nor between Vi-DT and Vi-TT groups. For solicited adverse events within 4 weeks, the VI-DT group showed no significant increase in adverse events compared to control (RR: 0.93 [95% CI: 0.78, 1.12]) or Vi-TT (RR: 0.86 [95% CI: 0.69, 1.07]). Similarly, within 7 days post-vaccination, risk ratios indicated no significant differences in adverse events between the groups. The 4-week seroconversion rate was significantly higher in the Vi-DT group compared to the control (RR: 1.99 [95% CI: 1.07, 3.69]), but no difference was found between Vi-DT and Vi-TT. Adverse events associated with typhoid conjugate vaccines were predominantly non-serious, including fever and injection site reactions. Serious adverse events were rare but included conditions like pneumonia and gastroenteritis. Conclusion: This meta-analysis highlights Vi-DT safety and immunogenicity in six to 24-month-old children. The findings support the use of this Vi-DT to expand typhoid vaccination in endemic regions, in line with WHO's strategy.

3.
BMC Cardiovasc Disord ; 24(1): 65, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38262990

RESUMEN

INTRODUCTION: The published studies comparing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) in pure aortic regurgitation (AR) are conflicting. We conducted this systematic review and meta-analysis to compare TAVI with SAVR in pure AR. METHODS: We searched PubMed, Embase, Web of Science (WOS), Scopus, and the Cochrane Library Central Register of Controlled Trials (CENTRAL) from inception until 23 June 2023. Review Manager was used for statistical analysis. The risk ratio (RR) with a 95% confidence interval (CI) was used to compare dichotomous outcomes. Continuous outcomes were compared using the mean difference (MD) and 95% CI. The inconsistency test (I2) assessed the heterogeneity. We used the Newcastle-Ottawa scale to assess the quality of included studies. We evaluated the strength of evidence using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) scale. RESULTS: We included six studies with 5633 patients in the TAVI group and 27,851 in SAVR. In-hospital mortality was comparable between TAVI and SAVR (RR = 0.89, 95% CI [0.56, 1.42], P = 0.63) (I2 = 86%, P < 0.001). TAVI was favored over SAVR regarding in-hospital stroke (RR = 0.50; 95% CI [0.39, 0.66], P < 0.001) (I2 = 11%, P = 0.34), in-hospital acute kidney injury (RR = 0.56; 95% CI: [0.41, 0.76], P < 0.001) (I2 = 91%, P < 0.001), major bleeding (RR = 0.23; 95% CI: [0.17, 0.32], P < 0.001) (I2 = 78%, P < 0.001), and shorter hospital say (MD = - 4.76 days; 95% CI: [- 5.27, - 4.25], P < 0.001) (I2 = 88%, P < 0.001). In contrast, TAVI was associated with a higher rate of pacemaker implantation (RR = 1.68; 95% CI: [1.50, 1.88], P < 0.001) (I2 = 0% P = 0.83). CONCLUSION: TAVI reduces in-hospital stroke and is associated with better safety outcomes than SAVR in patients with pure AR.


Asunto(s)
Lesión Renal Aguda , Insuficiencia de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica
4.
Pacing Clin Electrophysiol ; 47(2): 281-291, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38071455

RESUMEN

INTRODUCTION: The implantable cardioverter-defibrillator (ICD) was designed to detect and treat ventricular arrhythmias, which account for nearly half of all cardiovascular fatalities. Transvenous ICD (TV-ICD) complications were reduced by introducing subcutaneous ICD (S-ICD). S-ICD can be implanted using a three (3IT)- or two (2IT)-incision technique. This systematic review and meta-analysis was conducted to compare the 3IT to the 2IT. METHODS: We searched medical electronic databases of Cochrane Central, Embase, PubMed, Scopus, and Web of Science (WOS) from the study's inception until March 8, 2023. We compared 2IT and 3IT techniques of S-ICDs in terms of procedural, safety, and efficacy outcomes. We used Review Manager software for the statistical analysis. We calculated the risk ratio (RR) with its 95% confidence interval (CI) for dichotomous variables; and the mean difference with its 95% CI for continuous variables. We measured the heterogeneity using the chi-squared and I-squared tests. If the data were heterogeneous, the random-effect (RE) model was applied; otherwise, the fixed-effect model (FE) was used. RESULTS: We included three retrospective observational studies of 2076 patients, 1209 in the 2IT group and 867 in the 3IT. There was no statistically significant difference in erosion after S-ICD when 2IT compared with 3IT (RR = 0.27, 95% CI: [0.07, 1.02]; P = .05) (I2 = 0%, P = .90). There was no difference in risk of infection, lead dislocation, or inappropriate shock with either incision technique (RR = 0.78, 95% CI: [0.48, 1.29]; P = .34) (I2 = 0%, P = .71) and (RR = 0.37, 95% CI: [0.02, 8.14]; P = .53) (I2 = 66%, P = .05) respectively. Our meta-analysis showed that the efficacy of both techniques is comparable; Appropriate shock (RR = 0.94, 95% CI: [0.78, 1.12]; P = .48) (I2 = 0%, P = .81) and first shock efficacy (RR = 0.89, 95% CI: [0.44, 1.82]; P = .76) (I2 = 0%, P = .87). CONCLUSION: 2IT and 3IT of S-ICD have comparable efficacy and complication rates; however, the 3IT exposes patients to an additional incision without any additional benefits. These findings may provide clinicians with a simpler method for subcutaneous ICD implantation and likely result in improved cosmetic outcomes. Before the 2IT technique can be considered the standard of care, randomized controlled trials (RCTs) must be conducted to assess its long-term safety and efficacy.


Asunto(s)
Desfibriladores Implantables , Humanos , Resultado del Tratamiento , Cardioversión Eléctrica , Arritmias Cardíacas , Estudios Retrospectivos , Muerte Súbita Cardíaca
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...