Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
JOR Spine ; 7(2): e1322, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38666074

RESUMEN

Background: Cadaveric intervertebral discs are often studied for a variety of research questions, and outcomes are interpreted in the in vivo context. Unfortunately, the cadaveric disc does not inherently represent the LIVE condition, such that the disc structure (geometry), composition (T2 relaxation time), and mechanical function (opening pressure, OP) measured in the cadaver do not necessarily represent the in vivo disc. Methods: We conducted serial evaluations in the Yucatan minipig of disc geometry, T2 relaxation time, and OP to quantify the changes that occur with progressive dissection and used axial loading to restore the in vivo condition. Results: We found no difference in any parameter from LIVE to TORSO; thus, within 2 h of sacrifice, the TORSO disc can represent the LIVE condition. With serial dissection and sample preparation the disc height increased (SEGMENT height 18% higher than TORSO), OP decreased (POTTED was 67% lower than TORSO), and T2 time was unchanged. With axial loading, an imposed stress of 0.20-0.33 MPa returned the disc to in vivo, LIVE disc geometry and OP, although T2 time was decreased. There was a linear correlation between applied stress and OP, and this was conserved across multiple studies and species. Conclusion: To restore the LIVE disc state in human studies or other animal models, we recommend measuring the OP/stress relationship and using this relationship to select the applied stress necessary to recover the in vivo condition.

2.
J Orthop Res ; 42(6): 1343-1355, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38245852

RESUMEN

The intervertebral disc is an important structure for load transfer through the spine. Its injury and degeneration have been linked to pain and spinal fractures. Disc injury and spine fractures are associated with high stresses; however, these stresses cannot be measured, necessitating the use of finite element (FE) models. These models should include the disc's complex structure, as changes in disc geometry have been linked to altered mechanical behavior. However, image-based models using disc-specific structures have yet to be established. This study describes a multiphasic FE modeling approach for noninvasive estimates of subject-specific intervertebral disc mechanical behavior based on medical imaging. The models (n = 22) were used to study the influence of disc geometry on the predicted global mechanical response (moments and forces), internal local disc stresses, and tractions at the interface between the disc and the bone. Disc geometry was found to have a strong influence on the predicted moments and forces on the disc (R2 = 0.69-0.93), while assumptions regarding the side curvature (bulge) of the disc had only a minor effect. Strong variability in the predicted internal disc stresses and tractions was observed between the models (mean absolute differences of 5.1%-27.7%). Disc height had a systematic influence on the internal disc stresses and tractions at the disc-to-bone interface. The influence of disc geometry on mechanics highlights the importance of disc-specific modeling to estimate disc injury risk, loading on the adjacent vertebral bodies, and the mechanical environment present in disc tissues.


Asunto(s)
Análisis de Elementos Finitos , Disco Intervertebral , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/fisiología , Humanos , Fenómenos Biomecánicos , Adulto , Masculino , Femenino , Estrés Mecánico , Persona de Mediana Edad , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiología , Modelos Biológicos
4.
Pathophysiology ; 30(4): 618-629, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38133145

RESUMEN

The menisci increase the contact area of load bearing in the knee and thus disperse the mechanical stress via their circumferential tensile fibers. Traumatic meniscus injuries cause mechanical symptoms in the knee, and are more prevalent amongst younger, more active patients, compared to degenerative tears amongst the elderly population. Traumatic meniscus tears typically result from the load-and-shear mechanism in the knee joint. The treatment depends on the size, location, and pattern of the tear. For non-repairable tears, partial or total meniscal resection decreases its tensile stress and increases joint contact stress, thus potentiating the risk of arthritis. A longitudinal vertical tear pattern at the peripheral third red-red zone leads to higher healing potential after repair. The postoperative rehabilitation protocols after repair range from immediate weight-bearing with no range of motion restrictions to non-weight bearing and delayed mobilization for weeks. Pediatric and adolescent patients may require special considerations due to their activity levels, or distinct pathologies such as a discoid meniscus. Further biomechanical and biologic evidence is needed to guide surgical management, postoperative rehabilitation protocols, and future technology applications for traumatic meniscus injuries.

5.
BMC Res Notes ; 16(1): 127, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37391824

RESUMEN

OBJECTIVES: Mechanical loading is crucial for tendon matrix homeostasis. Under-stimulation of tendon tissue promotes matrix degradation and ultimately tendon failure. In this study, we examined the expression of tendon matrix molecules and matrix-degrading enzymes (matrix metalloproteinases) in stress-deprived tail tendons and compared to tendons that were mechanically loaded by a simple restraining method. DATA DESCRIPTION: Isolated mouse tail fascicles were either floated or restrained by magnets in cell culture media for 24 h. The gene expression of tendon matrix molecules and matrix metalloproteinases in the tendon fascicles of mouse tails were examined by real-time RT-PCR. Stress deprivation of tail tendons increase Mmp3 mRNA levels. Restraining tendons represses these increases in Mmp3. The gene expression response to restraining was specific to Mmp3 at 24 h as we did not observe mRNA level changes in other matrix related genes that we examined (Col1, Col3, Tnc, Acan, and Mmp13). To elucidate, the mechanisms that may regulate load transmission in tendon tissue, we examined filamentous (F-)actin staining and nuclear morphology. As compared to stress deprived tendons, restrained tendons had greater staining for F-actin. The nuclei of restrained tendons are smaller and more elongated. These results indicate that mechanical loading regulates specific gene expression potentially through F-actin regulation of nuclear morphology. A further understanding on the mechanisms involved in regulating Mmp3 gene expression may lead to new strategies to prevent tendon degeneration.


Asunto(s)
Actinas , Metaloproteinasa 3 de la Matriz , Estrés Mecánico , Tendones , Animales , Ratones , Fenómenos Magnéticos , Metaloproteinasa 3 de la Matriz/genética , ARN Mensajero/genética , Tendones/fisiología
6.
J Biomech Eng ; 145(10)2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37338241

RESUMEN

The spine is a multi-tissue musculoskeletal system that supports large multi-axial loads and motions during physiological activities. The healthy and pathological biomechanical function of the spine and its subtissues are generally studied using cadaveric specimens that often require multi-axis biomechanical test systems to mimic the complex loading environment of the spine. Unfortunately, an off-the-shelf device can easily exceed 200,000 USD, while a custom device requires extensive time and experience in mechatronics. Our goal was to develop a cost-appropriate compression and bending (flexion-extension and lateral bending) spine testing system that requires little time and minimal technical knowledge. Our solution was an off-axis loading fixture (OLaF) that mounts to an existing uni-axial test frame and requires no additional actuators. OLaF requires little machining, with most components purchased off-the-shelf, and costs less than 10,000 USD. The only external transducer required is a six-axis load cell. Furthermore, OLaF is controlled using the existing uni-axial test frame's software, while the load data is collected using the software included with the six-axis load cell. Here we provide the design rationale for how OLaF develops primary motions and loads and minimizes off-axis secondary constraints, verify the primary kinematics using motion capture, and demonstrate that the system is capable of applying physiologically relevant, noninjurious, axial compression and bending. While OLaF is limited to compression and bending studies it produces repeatable physiologically relevant biomechanics, with high quality data, and minimal startup costs.


Asunto(s)
Columna Vertebral , Humanos , Fenómenos Biomecánicos , Movimiento (Física) , Soporte de Peso/fisiología , Presión , Rango del Movimiento Articular/fisiología
7.
J Biomech Eng ; 145(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37184932

RESUMEN

Tendon degeneration is typically described as an overuse injury with little distinction made between magnitude of load (overload) and number of cycles (overuse). Further, in vivo, animal models of tendon degeneration are mostly overuse models, where tendon damage is caused by a high number of load cycles. As a result, there is a lack of knowledge of how isolated overload leads to degeneration in tendons. A surgical model of synergist ablation (SynAb) overloads the target tendon, plantaris, by ablating its synergist tendon, Achilles. The objective of this study was to evaluate the structural and functional changes that occur following overload of plantaris tendon in a rat SynAb model. Tendon cross-sectional area (CSA) and shape changes were evaluated by longitudinal MR imaging up to 8 weeks postsurgery. Tissue-scale structural changes were evaluated by semiquantified histology and second harmonic generation microscopy. Fibril level changes were evaluated with serial block face scanning electron microscopy (SBF-SEM). Functional changes were evaluated using tension tests at the tissue and microscale using a custom testing system allowing both video and microscopy imaging. At 8 weeks, overloaded plantaris tendons exhibited degenerative changes including increases in CSA, cell density, collagen damage area fraction (DAF), and fibril diameter, and decreases in collagen alignment, modulus, and yield stress. To interpret the differences between overload and overuse in tendon, we introduce a new framework for tendon remodeling and degeneration that differentiates between the inputs of overload and overuse. In summary, isolated overload induces multiscale degenerative structural and functional changes in plantaris tendon.


Asunto(s)
Tendón Calcáneo , Músculo Esquelético , Ratas , Animales , Tendón Calcáneo/patología , Colágeno , Modelos Animales , Fibras Musculares Esqueléticas
8.
J Biomech Eng ; 145(8)2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37255448

RESUMEN

The meniscus serves important load-bearing functions and protects the underlying articular cartilage. Unfortunately, meniscus tears are common and impair the ability of the meniscus to distribute loads, increasing the risk of developing osteoarthritis. Therefore, surgical repair of the meniscus is a frequently performed procedure; however, repair does not always prevent osteoarthritis. This is hypothesized to be due to altered joint loading post-injury and repair, where the functional deficit of the meniscus prevents it from performing its role of distributing forces. The objective of this study was to quantify joint kinematics in an intact joint, after a meniscus root tear, and after suture repair in cadaveric porcine knees, a frequently used in vivo model. We utilized an magnetic resonance images-compatible loading device and novel use of a T1 vibe sequence to measure meniscus and femur displacements under physiological axial loads. We found that anterior root tear led to large meniscus displacements under physiological axial loading and that suture anchor repair reduced these displacements but did not fully restore intact joint kinematics. After tear and repair, the anterior region of the meniscus moved posteriorly and medially as it was forced out of the joint space under loading, while the posterior region had small displacements as the posterior attachment acted as a hinge about which the meniscus pivoted in the axial plane. Methods from this study can be applied to assess altered joint kinematics following human knee injuries and evaluate repair strategies aimed to restore joint kinematics.


Asunto(s)
Menisco , Osteoartritis , Lesiones de Menisco Tibial , Humanos , Porcinos , Animales , Meniscos Tibiales/cirugía , Cadáver , Articulación de la Rodilla , Fenómenos Biomecánicos , Imagen por Resonancia Magnética
9.
J Biomech Eng ; 145(7)2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36939383

RESUMEN

Load-induced volume change is an important aspect of knee meniscus function because volume loss creates fluid pressure, which minimizes friction and helps support compressive loads. The knee meniscus is unusual amongst cartilaginous tissues in that it is loaded not only in axial compression, but also in circumferential tension between its tibial attachments. Despite the physiologic importance of the knee meniscus' tensile properties, its volumetric strain in tension has never been directly measured, and predictions of volume strain in the scientific literature are inconsistent. In this study, we apply uniaxial tension to bovine knee meniscus and use biplanar imaging to directly observe the resulting three-dimensional volume change and unloaded recovery, revealing that tension causes volumetric contraction. Compression is already known to also cause contraction; therefore, all major physiologic loads compress and pressurize the meniscus, inducing fluid outflow. Although passive unloaded recovery is often described as slow relative to loaded loss, here we show that at physiologic strains the volume recovery rate in the meniscus upon unloading is faster than the rate of volume loss. These measurements of volumetric strain are an important step toward a complete theory of knee meniscus fluid flow and load support.


Asunto(s)
Meniscos Tibiales , Menisco , Animales , Bovinos , Articulación de la Rodilla , Tibia , Estrés Mecánico
10.
JOR Spine ; 6(1): e1243, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36994458

RESUMEN

Background: Intervertebral disc degeneration is often implicated in low back pain; however, discs with structural degeneration often do not cause pain. It may be that disc mechanics can provide better diagnosis and identification of the pain source. In cadaveric testing, the degenerated disc has altered mechanics, but in vivo, disc mechanics remain unknown. To measure in vivo disc mechanics, noninvasive methods must be developed to apply and measure physiological deformations. Aim: Thus, this study aimed to develop methods to measure disc mechanical function via noninvasive MRI during flexion and extension and after diurnal loading in a young population. This data will serve as baseline disc mechanics to later compare across ages and in patients. Materials & Methods: To accomplish this, subjects were imaged in the morning in a reference supine position, in flexion, in extension, and at the end of the day in a supine position. Disc deformations and vertebral motions were used to quantify disc axial strain, changes in wedge angle, and anterior-posterior (A-P) shear displacement. T2 weighted MRI was also used to evaluate disc degeneration via Pfirrmann grading and T2 time. All measures were then tested for effect of sex and disc level. Results: We found that flexion and extension caused level-dependent strains in the anterior and posterior of the disc, changes in wedge angle, and A-P shear displacements. Flexion had higher magnitude changes overall. Diurnal loading did not cause level-dependent strains but did cause small level-dependent changes in wedge angle and A-P shear displacements. Discussion: Correlations between disc degeneration and mechanics were largest in flexion, likely due to the smaller contribution of the facet joints in this condition. Conclusion: In summary, this study established methods to measure in vivo disc mechanical function via noninvasive MRI and established a baseline in a young population that may be compared to older subjects and clinical disorders in the future.

11.
bioRxiv ; 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36778395

RESUMEN

The meniscus serves important load-bearing functions and protects the underlying articular cartilage. Unfortunately, meniscus tears are common and impair the ability of the meniscus to distribute loads, greatly increasing the risk for developing osteoarthritis. Therefore, surgical repair of the meniscus is a frequently performed procedure; however, this repair does not always prevent osteoarthritis. This is hypothesized to be due to altered joint loading post injury and repair, where the functional deficit of the meniscus prevents it from performing its role of distributing forces. However, many studies of meniscus function required opening the joint, which alters kinematics. The objective of this study was to use novel MRI methods to image the intact joint under axial load and measure the acute meniscus and femur displacements in an intact joint, after a meniscus root tear, and after suture repair in the porcine knee, a frequently used in vivo model. We found that anterior root tear led to large meniscus and femur displacements under physiological axial loading, and that suture anchor repair reduced these displacements, but did not fully restore intact joint kinematics. After tear and repair, the anterior region of the meniscus moved posteriorly and medially as it was forced out of the joint space under loading, while the posterior region had small displacements as the posterior attachment acted as a hinge about which the meniscus rotated in the axial plane. This technique can be applied to evaluate the effect of knee injuries and to develop improved repair strategies to restore joint kinematics.

12.
Mol Biol Cell ; 33(14): ar141, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36129771

RESUMEN

Actin is a central mediator between mechanical force and cellular phenotype. In tendons, it is speculated that mechanical stress deprivation regulates gene expression by reducing filamentous (F)-actin. However, the mechanisms regulating tenocyte F-actin remain unclear. Tropomyosins (Tpms) are master regulators of F-actin. There are more than 40 Tpm isoforms, each having the unique capability to stabilize F-actin subpopulations. We investigated F-actin polymerization in stress-deprived tendons and tested the hypothesis that stress fiber-associated Tpm(s) stabilize F-actin to regulate cellular phenotype. Stress deprivation of mouse tail tendon down-regulated tenogenic and up-regulated protease (matrix metalloproteinase-3) mRNA levels. Concomitant with mRNA modulation were increases in G/F-actin, confirming reduced F-actin by tendon stress deprivation. To investigate the molecular regulation of F-actin, we identified that tail, Achilles, and plantaris tendons express three isoforms in common: Tpm1.6, 3.1, and 4.2. Tpm3.1 associates with F-actin in native and primary tenocytes. Tpm3.1 inhibition reduces F-actin, leading to decreases in tenogenic expression, increases in chondrogenic expression, and enhancement of protease expression in mouse and human tenocytes. These expression changes by Tpm3.1 inhibition are consistent with tendinosis progression. A further understanding of F-actin regulation in musculoskeletal cells could lead to new therapeutic interventions to prevent alterations in cellular phenotype during disease progression.


Asunto(s)
Actinas , Tendinopatía , Humanos , Ratones , Animales , Actinas/metabolismo , Tendinopatía/metabolismo , Tendones/metabolismo , Isoformas de Proteínas/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Fenotipo , Péptido Hidrolasas/metabolismo , Tropomiosina/metabolismo
13.
Orthop J Sports Med ; 9(11): 23259671211035444, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34796238

RESUMEN

BACKGROUND: The corrective procedures for meniscal injury are dependent on tear type, severity, and location. Vertical longitudinal tears are common in young and active individuals, but their natural progression and impact on osteoarthritis (OA) development are not known. Root tears are challenging and they often indicate poor outcomes, although the timing and mechanisms of initiation of joint dysfunction are poorly understood, particularly in large-animal and human models. PURPOSE/HYPOTHESIS: In this study, vertical longitudinal and root tears were made in a large-animal model to determine the progression of joint-wide dysfunction. We hypothesized that OA onset and progression would depend on the extent of injury-based load disruption in the tissue, such that root tears would cause earlier and more severe changes to the joint. STUDY DESIGN: Controlled laboratory study. METHODS: Sham surgeries and procedures to create either vertical longitudinal or root tears were performed in juvenile Yucatan mini pigs through randomized and bilateral arthroscopic procedures. Animals were sacrificed at 1, 3, or 6 months after injury and assessed at the joint and tissue level for evidence of OA. Functional measures of joint load transfer, cartilage indentation mechanics, and meniscal tensile properties were performed, as well as histological evaluation of the cartilage, meniscus, and synovium. RESULTS: Outcomes suggested a progressive and sustained degeneration of the knee joint and meniscus after root tear, as evidenced by histological analysis of the cartilage and meniscus. This occurred in spite of spontaneous reattachment of the root, suggesting that this reattachment did not fully restore the function of the native attachment. In contrast, the vertical longitudinal tear did not cause significant changes to the joint, with only mild differences compared with sham surgery at the 6-month time point. CONCLUSION: Given that the root tear, which severs circumferential connectivity and load transfer, caused more intense OA compared with the circumferentially stable vertical longitudinal tear, our findings suggest that without timely and mechanically competent fixation, root tears may cause irreversible joint damage. CLINICAL RELEVANCE: More generally, this new model can serve as a test bed for experimental surgical, scaffold-based, and small molecule-driven interventions after injury to prevent OA progression.

14.
JOR Spine ; 4(2): e1145, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34337333

RESUMEN

Finite element models of the intervertebral disc are used to address research questions that cannot be tested through typical experimentation. A disc model requires complex geometry and tissue properties to be accurately defined to mimic the physiological disc. The physiological disc possesses residual strain in the annulus fibrosus (AF) due to osmotic swelling and due to inherently pre-strained fibers. We developed a disc model with residual contributions due to swelling-only, and a multigeneration model with residual contributions due to both swelling and AF fiber pre-strain and validated it against organ-scale uniaxial, quasi-static and multiaxial, dynamic mechanical tests. In addition, we demonstrated the models' ability to mimic the opening angle observed following radial incision of bovine discs. Both models were validated against organ-scale experimental data. While the swelling only model responses were within the experimental 95% confidence interval, the multigeneration model offered outcomes closer to the experimental mean and had a bovine model opening angle within one SD of the experimental mean. The better outcomes for the multigeneration model, which allowed for the inclusion of inherently pre-strained fibers in AF, is likely due to its uniform fiber contribution throughout the AF. We conclude that the residual contribution of pre-strained fibers in the AF should be included to best simulate the physiological disc and its behaviors.

15.
J Orthop Res ; 39(5): 919-928, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33458882

RESUMEN

Macro-scale changes in longitudinal bone growth resulting from mechanical loading were shown in Part 1 of this review to depend on load magnitude, anatomical location, and species. While no significant effect on longitudinal growth was observed by varying frequency and amplitude of cyclic loading, such variations, in addition to loading duration and species, were shown to affect the morphology, viability, and gene and protein expression within the growth plate. Intermittent compression regimens were shown to preserve or increase growth plate height while stimulating increased chondrocyte presence in the hypertrophic zone relative to persistent and static loading regimens. Gene and protein expressions related to matrix synthesis and degradation, as well as regulation of chondrocyte apoptosis were shown to exhibit magnitude-, frequency-, and duration-dependent responses to loading regimen. Chondrocyte viability was shown to be largely preserved within physiological bounds of magnitude, frequency, amplitude, and duration. Persistent static loading was shown to be associated with overall growth plate height in tension only, reducing it in compression, while affecting growth plate zone heights differently across species and encouraging mineralization relative to intermittent cyclic loading. Lateral loading of the growth plate, as well as microfluidic approaches are relatively understudied, and age, anatomical location, and species effects within these approaches are undefined. Understanding the micro-scale effects of varied loading regimes can assist in the development of growth modulation methods and device designs optimized for growth plate viability preservation or mineralization stimulation based on patient age and anatomical location.


Asunto(s)
Desarrollo Óseo/fisiología , Placa de Crecimiento/fisiología , Animales , Calcificación Fisiológica , Condrocitos/metabolismo , Humanos , Especificidad de la Especie , Estrés Mecánico , Agua/análisis
16.
Acta Biomater ; 123: 197-207, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-33444797

RESUMEN

Determining tissue biomechanical material properties from mechanical test data is frequently required in a variety of applications. However, the validity of the resulting constitutive model parameters is the subject of debate in the field. Parameter optimization in tissue mechanics often comes down to the "identifiability" or "uniqueness" of constitutive model parameters; however, despite advances in formulating complex constitutive relations and many classic and creative curve-fitting approaches, there is currently no accessible framework to study the identifiability of tissue material parameters. Our objective was to assess the identifiability of material parameters for established constitutive models of fiber-reinforced soft tissues, biomaterials, and tissue-engineered constructs and establish a generalizable procedure for other applications. To do so, we generated synthetic experimental data by simulating uniaxial tension and compression tests, commonly used in biomechanics. We then fit this data using a multi-start optimization technique based on the nonlinear least-squares method with multiple initial parameter guesses. We considered tendon and sclera as example tissues, using constitutive models that describe these fiber-reinforced tissues. We demonstrated that not all the model parameters of these constitutive models were identifiable from uniaxial mechanical tests, despite achieving virtually identical fits to the stress-stretch response. We further show that when the lateral strain was considered as an additional fitting criterion, more parameters are identifiable, but some remain unidentified. This work provides a practical approach for addressing parameter identifiability in tissue mechanics.


Asunto(s)
Modelos Biológicos , Tendones , Fenómenos Biomecánicos , Estrés Mecánico
17.
Ann Biomed Eng ; 49(3): 1058-1068, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33128181

RESUMEN

One of the most common bath solutions used in musculoskeletal mechanical testing is phosphate buffered saline (PBS). In tendon, swelling induced by physiological PBS results in decreased tendon modulus and induces microstructural changes. It is critical to evaluate the multiscale mechanical behavior of tendon under swelling to interpret prior work and provide information to design future studies. We compared the effects of physiological PBS and 8% polyethylene glycol and saline bathing solutions on tendon multiscale tendon mechanics and damage as well as microstructure with TEM in order to understand the effect of swelling on tendon. At the tissue level, tendons in PBS had a lower modulus than SPEG samples. PBS samples also showed an increased amount of non-recoverable sliding, which is an analog for microscale damage. SPEG had a higher microscale to tissue-scale strain ratio, showing the fibrils experienced less strain attenuation. From the TEM data, we showed the fibril spacing of SPEG samples was more similar to fresh control than PBS. We concluded that swelling alters multiscale mechanics and damage in addition to tendon microstructure. Future mechanical testing should consider using SPEG as a bath solution with an osmotic pressure which preserves fresh tissue water content.


Asunto(s)
Concentración Osmolar , Traumatismos de los Tendones , Tendones , Animales , Fenómenos Biomecánicos , Femenino , Microscopía Electrónica de Transmisión , Polietilenglicoles , Ratas Long-Evans , Solución Salina , Estrés Mecánico , Traumatismos de los Tendones/etiología , Traumatismos de los Tendones/fisiopatología , Tendones/fisiología , Tendones/ultraestructura
18.
Tissue Eng Part A ; 27(1-2): 117-128, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32546053

RESUMEN

Intervertebral disc degeneration is a cascade of cellular, structural, and biomechanical changes that is strongly implicated as a cause of low-back pain. Current treatment strategies have poor long-term efficacy as they seek only to alleviate symptoms without preserving or restoring native tissue structure and function. The objective of this study was to evaluate the efficacy of a combined triple interpenetrating network hydrogel (comprising dextran, chitosan, and teleostean) and mesenchymal stem cell (MSC) therapy targeting moderate-severity disc degeneration in a clinically relevant goat model. Degeneration was induced in lumbar discs of 10 large frame goats by injection of chondroitinase ABC. After 12 weeks, degenerate discs were treated by injection of either hydrogel alone or hydrogel seeded with allogeneic, bone marrow-derived MSCs. Untreated healthy and degenerate discs served as controls, and animals were euthanized 2 weeks after treatment. Discs exhibited a significant loss of disc height 12 weeks after degeneration was induced. Two weeks after treatment, discs that received the combined hydrogel and MSC injection exhibited a significant, 10% improvement in disc height index, as well as improvements in histological condition. Discs that were treated with hydrogel alone exhibited reduced tumor necrosis factor-α expression in the nucleus pulposus (NP). Microcomputed tomography imaging revealed that the hydrogel remained localized to the central NP region of all treated discs after 2 weeks of unrestricted activity. These encouraging findings motivate further, longer term studies of therapeutic efficacy of hydrogel and MSC injections in this large animal model. Impact statement Low-back pain is the leading cause of disability worldwide, and degeneration of the intervertebral discs is considered to be one of the most common reasons for low-back pain. Current treatment strategies focus solely on alleviation of symptoms, and there is a critical need for new treatments that also restore disc structure and function. In this study, using a clinically relevant goat model of moderate-severity disc degeneration, we demonstrate that a combined interpenetrating network hydrogel and mesenchymal stem cell therapy provides acute improvements in disc height, histological condition, and local inflammation.


Asunto(s)
Degeneración del Disco Intervertebral , Disco Intervertebral , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Animales , Modelos Animales de Enfermedad , Cabras , Hidrogeles/farmacología , Degeneración del Disco Intervertebral/terapia , Microtomografía por Rayos X
19.
J Orthop Res ; 39(5): 907-918, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33377536

RESUMEN

Growth modulation is an emerging method for treatment of angular skeletal deformities such as adolescent idiopathic scoliosis (AIS). The Hueter-Volkmann law, by which growth is stimulated in tension and inhibited in compression, is widely understood, and applied in current growth-modulating interventions such as anterior vertebral body tethering (AVBT) for AIS. However, without quantification of the growth rate effects of tension or compression, the possibility of under- or over- correction exists. A definitive mechanical growth modulation relationship relating to treatment of such skeletal deformities is yet to exist, and the mechanisms by which growth rate is regulated and altered are not fully defined. Review of current literature demonstrates that longitudinal (i.e., lengthwise) growth rate in multiple animal models depend on load magnitude, anatomical location, and species. Additionally, alterations in growth plate morphology and viability vary by loading parameters such as magnitude, frequency, and whether the load was applied persistently or intermittently. The aggregate findings of the reviewed studies will assist in work towards increasingly precise and clinically successful growth modulation methods. Part 1 of this review focuses on the effects of mechanical loading, species, age, and anatomical location on the macro-scale alterations in longitudinal bone growth, as well as factors that affect growth plate material properties. Part 2 considers the effects on micro-scale alterations in growth plate morphology such as zone heights and proportions, chondrocyte viability, and related gene and protein expression.


Asunto(s)
Desarrollo Óseo/fisiología , Placa de Crecimiento/fisiología , Factores de Edad , Animales , Humanos , Modelos Animales , Especificidad de la Especie
20.
JOR Spine ; 3(3): e1102, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33015575

RESUMEN

Noninvasive assessments of intervertebral disc health and degeneration are critical for addressing disc degeneration and low back pain. Magnetic resonance imaging (MRI) is exceptionally sensitive to tissue with high water content, and measurement of the MR transverse relaxation time, T 2, has been applied as a quantitative, continuous, and objective measure of disc degeneration that is linked to the water and matrix composition of the disc. However, T 2 measurement is susceptible to inaccuracies due to Rician noise, T 1 contamination, and stimulated echo effects. These error generators can all be controlled for with proper data collection and fitting methods. The objective of this study was to identify sequence parameters to appropriately acquire MR data and to establish curve fitting methods to accurately calculate disc T 2 in the presence of noise by correcting for Rician noise. To do so, we compared T 2 calculated from the typical monoexponential (MONO) fits and noise corrected exponential (NCEXP) fits. We examined how the selected sequence parameters altered the calculated T 2 in silico and in vivo. Typical MONO fits were frequently poor due to Rician noise, and NCEXP fits were more likely to provide accurate T 2 calculations. NCEXP is particularly less biased and less uncertain at low SNR. This study showed that the NCEXP using sequences with data from 20 echoes out to echo times of ~300 ms is the best method for calculating T 2 of discs. By acquiring signal data out to longer echo times and accounting for Rician noise, the curve fitting is more robust in calculating T 2 despite the noise in the data. This is particularly important when considering degenerate discs or AF tissue because the SNR of these regions is lower.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA