Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
2.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38471835

RESUMEN

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Angiopoyetina 2 , Interleucina-6 , Modelos Estadísticos , Volumen Sistólico , Remodelación Ventricular , Factores de Riesgo , Pronóstico , Recurrencia , Función Ventricular Izquierda , Biomarcadores , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-38448258

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38310499

RESUMEN

BACKGROUND: The Food and Drug Administration approved the Amulet occluder (Abbott) after demonstrating safety and effectiveness in the Amulet IDE (AMPLATZER Amulet LAA Occluder) trial. OBJECTIVES: The aim of the EMERGE Left Atrial Appendage study is to evaluate early postapproval outcomes of the Amulet occluder in the United States using data from the National Cardiovascular Data Registry Left Atrial Appendage Occlusion Registry. METHODS: Patients with a commercial Amulet occluder implant attempt between Food and Drug Administration approval (August 14, 2021) and December 31, 2022, were included. The safety composite endpoint included all-cause death, ischemic stroke, systemic embolism, or device/procedure-related events requiring open cardiac surgery or endovascular intervention between device implantation and 7 days or hospital discharge (whichever is later). Major adverse events through 45 days were also reported and stratified by operator experience (early [<10 cases], moderate [10-29 cases], and high [30+ cases]). RESULTS: A total of 5,499 patients underwent attempted Amulet occluder implantation. Implant success was 95.8%, and complete closure was 97.2% post-left atrial appendage occlusion and 87.1% at 45 days. A safety composite endpoint event occurred in 0.76% patients. Any major adverse event occurred in 2.9% and 5.7% of patients in-hospital and through 45 days, respectively, driven by major bleeding and pericardial effusion (PE) requiring intervention. PE requiring surgery or percutaneous intervention decreased significantly with increasing experience both in-hospital (early vs high operator experience 1.8% vs 1.1%; P = 0.006) and at 45 days (2.3% vs 1.5%; P = 0.012). CONCLUSIONS: The EMERGE Left Atrial Appendage study demonstrates favorable safety and effectiveness of the Amulet occluder in the real-world setting. More experienced operators had improved implant success and fewer PEs, suggesting a learning curve effect implanting this dual occlusive mechanism device.

6.
JACC Cardiovasc Interv ; 16(15): 1902-1913, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37587599

RESUMEN

BACKGROUND: The Amulet (Abbott) left atrial appendage occluder investigational device exemption trial is the largest randomized trial evaluating the safety and effectiveness of the Amulet left atrial appendage occluder compared with the Watchman 2.5 device (Boston Scientific) through 5 years. OBJECTIVES: This analysis evaluated the device effect on 3-year outcomes in the Amulet investigational device exemption trial. METHODS: The medication regimen and key clinical outcomes were reported through 3 years including: 1) the composite of ischemic stroke or systemic embolism (SE); 2) the composite of all strokes, SE, or cardiovascular (CV) death; 3) major bleeding; and 4) all-cause death and CV death. RESULTS: A total of 1,878 patients at 108 sites were randomized. A significantly higher percentage of patients were free of oral anticoagulation usage at 3 years with Amulet (96.2%) vs Watchman (92.5%) (P < 0.01). Clinical outcomes were comparable for the composite of ischemic stroke or SE (5.0% vs 4.6%; P = 0.69); the composite of all strokes, SE, or CV death (11.1% vs 12.7%; P = 0.31); major bleeding (16.1% vs 14.7%; P = 0.46); all-cause death (14.6% vs 17.9%; P = 0.08); and CV death (6.6% vs 8.5%; P = 0.14) for Amulet and Watchman, respectively. Through 3 years, device factors (device-related thrombus or peridevice leak ≥3 mm) preceded ischemic stroke events and CV deaths more frequently in Watchman compared with Amulet patients. CONCLUSIONS: The Amulet occluder demonstrated continued safety and effectiveness with over 96% free of oral anticoagulation usage through 3 years in a high-risk population compared to the Watchman device. (AMPLATZER Amulet LAA Occluder Trial [Amulet IDE]; NCT02879448).


Asunto(s)
Apéndice Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Anticoagulantes
7.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37584233

RESUMEN

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Dispositivo Oclusor Septal/efectos adversos , Cateterismo Cardíaco/efectos adversos , Accidente Cerebrovascular/etiología
8.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37634148

RESUMEN

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/clasificación , Fibrilación Atrial/cirugía , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia , Método Simple Ciego , Taquicardia/etiología , Resultado del Tratamiento
9.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1147-1157, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495323

RESUMEN

BACKGROUND: Experimental evidence suggests genetic variation in 4q25/PITX2 modulates pulmonary vein (PV) myocardial sleeve length. Although PV sleeves are the main target of atrial fibrillation (AF) ablation, little is known about the association between different PV sleeve characteristics with ablation outcomes. OBJECTIVES: This study sought to evaluate the association between clinical and genetic (4q25) risk factors with PV sleeve length in humans, and to evaluate the association between PV sleeve length and recurrence after AF ablation. METHODS: In a prospective, observational study of patients undergoing de novo AF ablation, PV sleeve length was measured using electroanatomic voltage mapping before ablation. The sentinel 4q25 AF susceptibility single nucleotide polymorphism, rs2200733, was genotyped. The primary analysis tested the association between clinical and genetic (4q25) risk factors with PV sleeve length using a multivariable linear regression model. Covariates included age, sex, body mass index, height, and persistent AF. The association between PV sleeve length and atrial arrhythmia recurrence (>30 seconds) was tested using a multivariable Cox proportional hazards model. RESULTS: Between 2014 and 2019, 197 participants were enrolled (median age 63 years [IQR: 55 to 70 years], 133 male [67.5%]). In multivariable modeling, men were found to have PV sleeves 2.94 mm longer than women (95% CI: 0.99-4.90 mm; P < 0.001). Sixty participants (30.5%) had one 4q25 risk allele and 6 (3.1%) had 2 alleles. There was no association between 4q25 genotype and PV sleeve length. Forty-six participants (23.4%) experienced arrhythmia recurrence within 3 to 12 months, but there was no association between recurrence and PV sleeve length. CONCLUSIONS: Common genetic variation at 4q25 was not associated with PV sleeve length and PV sleeve length was not associated with ablation outcomes. Men did have longer PV sleeves than women, but more research is needed to define the potential clinical significance of this observation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/genética , Fibrilación Atrial/cirugía , Genotipo , Estudios Prospectivos , Venas Pulmonares/cirugía , Factores de Riesgo , Anciano , Proteína del Homeodomínio PITX2
11.
Circ Arrhythm Electrophysiol ; 16(5): e011740, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36960716

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) infection has a high mortality. Previous investigations showed reduced postoperative infections using skin preparation with chlorhexidine, preoperative intravenous antibiotics, and a TYRX-a antibacterial envelope. The additional benefit of antibiotic pocket wash and postoperative antibiotics has not been systematically studied. METHODS: The ENVELOPE trial (A Randomized trial of Stand-Alone Use of the Antimicrobial Envelope in High-Risk Cardiac Device Patients) was a prospective, multicenter, randomized, controlled trial enrolling patients undergoing CIED procedures with ≥2 risk factors for infection. The control arm received standard chlorhexidine skin preparation, intravenous antibiotics, and the TYRX-a antibiotic envelope. The study arm received pocket wash (500 mL antibiotic solution) and postoperative antibiotics for 3 days along with the prophylactic control measures. The primary end point was CIED infection and system removal at 6 months. RESULTS: One thousand ten subjects (505 per arm) were enrolled and randomized. Patients were seen in person for a wound check with digital photo 2 weeks postimplant and at 3 and 6 months. CIED infection rate was low in both groups (1.0% control arm and 1.2% study arm, P=0.74). In the 11 subjects with infection and system removal, the time to study end point was 107±92 days with a PADIT (Prevention of Arrhythmia Device Infection Trial) score of 7.4 and a 64% 1-year mortality. Prior history of CIED infection independently predicted CIED system removal at 6 months in all subjects (odds ratio, 9.77, P=0.004). Of 11 infections requiring system removal, 5 were in the setting of pocket hematoma. CONCLUSIONS: The use of antibiotic pocket irrigation and postoperative oral antibiotics provides no additional benefit to the prophylactic measures of chlorhexidine skin preparation, preoperative intravenous antibiotics, and an antibiotic envelope in reducing CIED infection. Postoperative hematoma is a major risk factor for infection, driven by the use of antiplatelet and anticoagulant medications. The strongest predictor of CIED removal at 6 months, regardless of intervention, was prior CIED infection. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02809131.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Desfibriladores Implantables/efectos adversos , Estudios Prospectivos , Clorhexidina , Antibacterianos/uso terapéutico , Cardiopatías/complicaciones , Hematoma/etiología , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Marcapaso Artificial/efectos adversos
12.
J Chem Inf Model ; 63(7): 2196-2206, 2023 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-36977188

RESUMEN

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is a FDA-approved reversal agent, antagonizes opioids through competitive binding at the µ-opioid receptor (mOR). Thus, knowledge of the opioid's residence time is important for assessing the effectiveness of naloxone. Here, we estimated the residence times (τ) of 15 fentanyl and 4 morphine analogs using metadynamics and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann et al. Clin. Pharmacol. Therapeut. 2022, 120, 1020-1232). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.


Asunto(s)
Analgésicos Opioides , Naloxona , Analgésicos Opioides/farmacología , Naloxona/farmacología , Naloxona/metabolismo , Fentanilo/metabolismo , Fentanilo/farmacología , Morfina/química , Receptores Opioides mu/metabolismo , Antagonistas de Narcóticos
13.
JACC Cardiovasc Interv ; 16(6): 627-642, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-36990553

RESUMEN

Left atrial appendage occlusion is an increasingly adopted stroke prevention strategy in patients with atrial fibrillation. However, peridevice leaks after the procedure are not infrequent and have recently been shown to confer a higher risk for subsequent ischemic events. In this paper, the authors review the available research on the frequency, mechanisms, clinical significance, and management of peridevice leak after percutaneous left atrial appendage occlusion.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Incidencia , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Cateterismo Cardíaco/efectos adversos
14.
bioRxiv ; 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36945599

RESUMEN

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is an FDA-approved reversal agent, antagonizes opioids through competitive binding at the mu-opioid receptor (mOR). Thus, knowledge of opioid's residence time is important for assessing the effectiveness of naloxone. Here we estimated the residence times of 15 fentanyl and 4 morphine analogs using metadynamics, and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann, Li et al, Clin. Pharmacol. Therapeut. 2022). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning (ML) approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.

15.
JACC Clin Electrophysiol ; 9(1): 96-107, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36697204

RESUMEN

BACKGROUND: Device-related thrombus (DRT) following left atrial appendage occlusion (LAAO) can lead to adverse clinical outcomes. DRT rates and outcomes from randomized trials are limited. OBJECTIVES: This analysis investigated the incidence, predictors, and clinical outcomes of DRT following LAAO in the Amulet IDE (AMPLATZER Amulet LAA Occluder Trial) trial. METHODS: Successful implants occurred in 903 patients with an Amulet occluder (dual occlusive mechanism device) and 885 patients with a Watchman device (single occlusive mechanism device). These patients were then followed through 18 months and DRT was assessed by transesophageal echocardiography. RESULTS: The overall incidence of DRT was 3.9% (n = 70) with 3.4% (n = 30) in dual occlusive mechanism device patients and 4.8% (n = 40) in single occlusive mechanism device patients. Most DRTs (n = 19 of 31) were identified early (≤45 days) on the dual occlusive mechanism device, whereas most of the DRTs (n = 31 of 42) were identified late (>45 days) on the single occlusive mechanism device. Strong predictors of DRT included atrial fibrillation at time of procedure (HR: 2.44; 95% CI: 1.42-4.22; P < 0.01), female sex (HR: 1.65; 95% CI: 1.01-2.71; P = 0.04), and older age (HR: 1.04; 95% CI: 1.01-1.08; P = 0.02). There were no stroke events following DRT in the dual occlusive mechanism device group and 3 stroke events following DRT in the single occlusive mechanism device group. Patients with DRT were at a greater risk for cardiovascular mortality compared with non-DRT patients (8.7% vs 3.9%; HR: 2.33; 95% CI: 1.01-5.39; P = 0.04). CONCLUSIONS: Incidence of DRT following LAAO was low. Early DRTs are seen with the dual occlusive mechanism device and late DRTs are seen with the single occlusive mechanism device. Increased cardiovascular mortality risk in patients with DRT should be further investigated. (AMPLATZER Amulet LAA Occluder Trial; NCT02879448).


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Femenino , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Incidencia , Accidente Cerebrovascular/epidemiología , Trombosis/epidemiología , Trombosis/etiología
16.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36300705

RESUMEN

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Péptido Natriurético Encefálico , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/metabolismo , Ecocardiografía Transesofágica , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/química , Apnea Obstructiva del Sueño/diagnóstico , Volumen Sistólico , Función Ventricular Izquierda
18.
Heart Rhythm O2 ; 3(5): 493-500, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36340489

RESUMEN

Background: Left atrial appendage (LAA) occlusion is an alternative therapy to oral anticoagulants to reduce stroke risk in patients with nonvalvular atrial fibrillation (NVAF). The Amulet IDE trial compared the Amplatzer™ Amulet™ occluder (Abbott) with the Watchman™ 2.5 device (Boston Scientific) for LAA occlusion in patients with NVAF. Objective: The purpose of this study was to describe outcomes of the Amulet IDE trial roll-in cohort. Methods: At US sites up to 3 patients per implanter could be implanted with the Amulet occluder in the roll-in phase. The primary Endpoints in the Amulet IDE trial included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and rate of LAA occlusion at 45 days. Results: A total of 201 roll-in patients were enrolled. Device success occurred in 99% of patients, and device closure (residual jet ≤5 mm) was observed in 98.9% of patients at 45 days. The safety endpoint rate was numerically higher (worse) in the roll-in cohort compared to the randomized Amulet occluder cohort (18.4% vs 14.5%). Six patients (3.1%) experienced an ischemic stroke and 0 patients with a systemic embolism within 18 months, which was similar to the primary effectiveness endpoint rate in the randomized Amulet occluder cohort (2.8%). Conclusions: Despite lack of experience of the operators with the Amulet occluder in the roll-in phase, device implant success was high, a high rate of device closure was achieved, and low stroke rates were observed in patients with NVAF.

19.
JACC Cardiovasc Interv ; 15(21): 2127-2138, 2022 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-36357016

RESUMEN

BACKGROUND: Peridevice leak (PDL) is a limitation of left atrial appendage occlusion. OBJECTIVES: The aim of this study was to assess the incidence of and outcomes associated with PDL in the Amulet IDE (AMPLATZER™ Amulet™ LAA Occluder Trial) randomized controlled trial. METHODS: Patients with atrial fibrillation at increased stroke risk were randomly assigned to undergo either Amulet (dual occlusive mechanism) or Watchman 2.5 (single occlusive mechanism) device implantation. Transesophageal echocardiography was performed at 45 days and 12 months postprocedure. Clinically significant PDL was defined as ≥3 mm. The primary endpoint was ischemic stroke or systemic embolism, and the secondary endpoint was stroke, systemic embolism, or cardiovascular death. The Kaplan-Meier method was used to estimate 18-month cumulative event rates landmarked at day 45 postprocedure. RESULTS: A total of 1,593 patients underwent successful left atrial appendage occlusion and had an evaluable transesophageal echocardiographic studies at 45 days. The dual-occlusive mechanism device provided superior closure (defined as leak <3 mm) compared with the single-occlusive mechanism device at 45 days (88.9% vs 74.1%; P < 0.01) and 12 months (90.5% vs. 78.3%; P < 0.01). Through 18 months, PDL was associated with a higher, but not statistically significant, risk for the primary endpoint (3.6% vs 1.8%; adjusted HR: 1.98; 95% CI: 0.93-4.19; P = 0.07) and a statistically significantly higher risk for the secondary endpoint (8.1% vs. 4.7%; adjusted HR: 1.66; 95% CI: 1.02-2.69; P = 0.04). CONCLUSIONS: The dual-occlusive mechanism device provided superior closure compared with the single-occlusive mechanism device at both 45 days and 1 year postprocedure. PDL ≥3 mm was associated with a significantly increased 18-month risk for the composite of stroke, systemic embolism, or cardiovascular death. Completeness of closure of the left atrial appendage has important implications for patient outcomes. (AMPLATZER™ Amulet™ LAA Occluder Trial [Amulet IDE]; NCT02879448).


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Ecocardiografía Transesofágica/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Embolia/etiología , Cateterismo Cardíaco , Dispositivo Oclusor Septal/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...