Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dent Mater ; 40(5): 869-877, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38609774

RESUMEN

OBJECTIVES: This 3D finite element analysis study aimed to investigate the effect of reinforcing CAD-CAM bars on stress distribution in various components of a posterior composite bridge. METHODS: A virtual model mimicking the absence of an upper second premolar was created, featuring class II cavity preparations on the proximal surfaces of the adjacent abutment teeth surrounding the edentulous space. Five distinct finite element analysis (FEA) models were generated, each representing a CAD-CAM reinforcing bar material: 3-YTZP (IPS. emax ZirCAD MO; Zr), lithium disilicate (IPS e.max CAD; EX), nano-hybrid resin composite (Grandio Blocs; GB), Fibre-reinforced composite (Trilor; Tri), and polyetheretherketone (PEEK). A veneering resin composite was employed to simulate the replacement of the missing premolar (pontic). In the FEA, an axial force of 600 N and a transverse load of 20 N were applied at the center of the pontic. Subsequently, maximum von Mises (mvM) and maximum principal stresses (σmax) were computed across various components of the generated models. Additionally, shear stresses at the interface between the CAD-CAM bars and the veneering resin composite were determined. RESULTS: CAD-CAM materials with high modulus of elasticity, such as Zr and EX, exhibited the highest mvM stresses and shear stresses while transferring the lowest stress to the veneering resin composite in comparison to other materials. Conversely, PEEK demonstrated the lowest mvM stresses but produced the highest stresses within the veneering resin composite. There was a uniform distribution of mvM stresses in the remaining tooth structure among all groups, except for a noticeable elevation in the molar region of Zr and EX groups. SIGNIFICANCE: Reinforcing CAD-CAM bar materials with a high modulus of elasticity, such as Zr and EX, may result in debonding failures at the connector sites of posterior composite bridges. Conversely, GB, PEEK, and Tri have the potential to cause fracture failures at the connectors rather than debonding.


Asunto(s)
Benzofenonas , Resinas Compuestas , Diseño Asistido por Computadora , Análisis del Estrés Dental , Análisis de Elementos Finitos , Polietilenglicoles , Resinas Compuestas/química , Polietilenglicoles/química , Ensayo de Materiales , Humanos , Materiales Dentales/química , Cetonas/química , Fenómenos Biomecánicos , Polímeros/química , Porcelana Dental/química , Coronas con Frente Estético , Imagenología Tridimensional
2.
Dent Mater ; 40(5): 858-868, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38616152

RESUMEN

OBJECTIVES: This study evaluates the potential for osseointegration and remodeling of customized dental implants made from Titanium-Hydroxyapatite Functionally Graded Material (Ti-HAP FGM) with optimized geometry, using the finite element method (FEM). METHODS: The study utilized CT scan images to model and assemble various geometrical designs of dental implants in a mandibular slice. The mechanical properties of Ti-HAP FGMs were computed by varying volume fractions (VF) of hydroxyapatite (0-20%), and a bone remodeling algorithm was used to evaluate the biomechanical characteristics of the ultimate bone configuration in the peri-implant tissue. RESULTS: The findings of the FEA reveal that osseointegration improves with changes in the density and mechanical properties of the bone surrounding Ti-HAP implants, which are influenced by the varying VF of hydroxyapatite in the FGM. SIGNIFICANCE: Increasing the hydroxyapatite fraction improves osseointegration, and appropriate length and diameter selection of Ti-HAP dental implants contribute to their stability and longevity.


Asunto(s)
Remodelación Ósea , Implantes Dentales , Durapatita , Análisis de Elementos Finitos , Oseointegración , Titanio , Remodelación Ósea/fisiología , Durapatita/química , Titanio/química , Mandíbula , Tomografía Computarizada por Rayos X , Humanos , Fenómenos Biomecánicos , Diseño de Prótesis Dental , Algoritmos , Ensayo de Materiales
3.
J Adhes Dent ; 26: 53-64, 2024 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-38329120

RESUMEN

PURPOSE: This study investigated and compared the bond strengths, microleakage, microgaps, and marginal adaptation of self-adhesive resin composites (SAC) to dentin with or without universal adhesives. MATERIALS AND METHODS: Dentin surfaces of 75 molars were prepared for shear and microtensile bond strength testing (SBS and µTBS). Silicon molds were used to build up direct restorations using the following materials to form 5 groups: 1. Surefil One; 2. Prime&Bond active Universal Adhesive + Surefil One; 3. Vertise Flow; 4. OptiBond Universal + Vertise Flow; 5. Scotchbond Universal + Filtek Z500 (control group). Bonded specimens were thermocycled 10,000x before being tested either for SBS or µTBS using a universal testing machine at a crosshead speed of 0.5 mm/min. Direct mesial and distal class-II cavities were created on 100 sound premolars, with the gingival margin of distal cavities placed below CEJ and restored according to the five groups. After thermocycling, microleakage scores were assessed following immersion of restored premolars in 2% methylene blue dye for 24 h, while marginal gaps and adaptation percentages were investigated on epoxy resin replicas under SEM at magnifications of 2000X and 200X, respectively. Results were statistically analyzed with parametric and non-parametric tests as applicable, with a level of significance set at α = 0.05. RESULTS: Bond strengths, microleakage scores, microgaps, and percent marginal adaptation of Surefil One and Vertise Flow were significantly (p < 0.001) inferior to the control group. Dentin preconditioning with universal adhesives significantly increased the study parameter outcomes of Surefil One and Vertise Flow, yet they were still significantly below the performance of the control group. CONCLUSION: Conventional resin composite outperformed the SAC whether applied solely or in conjunction with their corresponding universal adhesives.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Bisfenol A Glicidil Metacrilato/química , Cementos de Resina/química , Recubrimientos Dentinarios/química , Restauración Dental Permanente/métodos , Cementos Dentales , Dentina , Resinas Compuestas/química , Ensayo de Materiales
4.
Dent Mater ; 40(2): 227-235, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37977990

RESUMEN

OBJECTIVES: To evaluate and compare the effect of tooth preparation designs and different CADCAM. materials on stress distribution and Weibull survival probability of endocrowns. applied to root canal-treated lower first permanent molar using the 3D finite element. analysis method. METHODS: A root canal-treated lower first permanent molar was prepared for endocrowns with a. butt joint or with a ferrule design by placing, circumferentially, a 1-mm wide shoulder. finish line. The prepared molar was scanned for the two designs and modeled on a 3D. Finite element model. Monolithic zirconia (IPS e.max ZirCAD MT, FCZ), lithium. disilicate (IPS e.max CAD, EX), and nano-ceramic resin composite (Lava Ultimate, LU). CAD-CAM materials were used for each preparation to design the virtual endocrown. A. total of six models were built according to the different tooth preparation designs and. endocrown materials. An occlusal load of 600 N and a transverse load of 20 N in. magnitude that simulates the average occlusal load was directed toward the occlusal. surfaces. von Mises and maximum principle values were evaluated Weibull risk-ofrupture. analysis was used to analyze the survival probability of the restorations and. tooth in the different models. RESULTS: The highest von Mises were found in the butt joint design for FCZ, EX, and LU (45.3. MPa, 35.2 MPa, and 24.2 MPa, respectively) compared to the ferrule design for the. same materials (42.6 MPa, 31.2 MPa, and 23.6 MPa, respectively). For von Mises. stress distribution in the remaining part of tooth structure (dentin), the highest stresses. were found in LUFerrule which was closely similar to LUButt joint (135.4 MPa and. 134.7 MPa, respectively), followed by EXFerrule and FCZFerrule (132.2 MPa and. 131.7 MPa, respectively), while the lowest stresses were found in EXButt joint and. FCZButt joint (129.0 MPa and 128.4 MPa, respectively). Shear stresses within the. resin cement were the highest in FCZ and EX compared to LU. EX was found to be the. most reliable material with the highest survival probability, while FCZ showed the. lowest survival probability according to the Weibull risk-of-fracture results. SIGNIFICANCE: Materials with high elastic modulus transfer more stresses to the endocrown and less. to the remaining tooth structure. Endocrown tooth preparation with ferrule design has. better stress distribution and magnitude compared to the butt joint design.


Asunto(s)
Cerámica , Porcelana Dental , Análisis de Elementos Finitos , Cerámica/química , Resinas Compuestas/química , Diente Molar , Diseño Asistido por Computadora , Ensayo de Materiales , Análisis del Estrés Dental , Coronas
5.
Angle Orthod ; 93(6): 659-666, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37922388

RESUMEN

OBJECTIVES: To investigate the post-treatment stability of anterior open bite (AOB) cases treated with upper and lower extrusion arches in adults. MATERIALS AND METHODS: 23 patients with AOB were treated with extrusion arches and evaluated for dentoskeletal changes using lateral cephalometric radiographs before treatment (T0), after treatment (T1), and 12 months post-treatment (T2). Patients received bondable tongue spurs and vacuum-formed retainers as post-treatment retention/stability measures for 12 months. Post-treatment stability was further assessed qualitatively by the Photographic Openbite Severity Index. RESULTS: All the cases showed positive overlap between the anterior teeth at the end of orthodontic treatment, and 20 of 23 treated patients attended the recall visit after 12 months. A total of 85% of the cases maintained positive overlap at least 1 year post-treatment, 10% showed edge-to-edge bite, and only 5% showed no overbite. CONCLUSIONS: Treatment of AOB in adults with extrusion arches proved to be stable 1 year post-treatment. Changes in the overbite after 1 year of follow-up were not significant.


Asunto(s)
Maloclusión Clase II de Angle , Mordida Abierta , Sobremordida , Diente , Humanos , Adulto , Mordida Abierta/diagnóstico por imagen , Mordida Abierta/terapia , Estudios de Seguimiento , Cefalometría
6.
Sci Rep ; 13(1): 15341, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37714943

RESUMEN

In-office bleaching, using hydrogen peroxide, is effective to remove dental enamel stains. However, bleaching agents can deteriorate surface properties of CAD-CAM materials. This in vitro study aimed to investigate the effect of in-office bleaching agents on Vickers hardness and surface topography of polished and unpolished dental CAD-CAM composite materials (Grandio blocs, Lava Ultimate, BRILLIANT Crios, Cerasmart), and a polymer-infiltrated ceramic network block (Vita Enamic). The specimens were randomly divided into two groups: unpolished or polished. The micro-hardness and surface topography of each group were measured before bleaching, after a 60 min bleaching period, and 24-h and one-month post-bleaching. In-office bleaching significantly influenced the Vickers hardness of both the polished and unpolished CAD/CAM composite blocks, with Vita Enamic exhibiting the least hardness stability among all groups. Furthermore, in-office bleaching significantly influenced the surface roughness of unpolished CAD/CAM composite blocks. There was a significant difference in hardness reduction between the polished and unpolished specimens for most of the investigated materials at different time points. The bleaching did not influence the surface roughness of the investigated polished group, except for Vita Enamic and Lava Ultimate. However, it did influence the surface roughness of the investigated materials in the unpolished group.


Asunto(s)
Blanqueadores , Dureza , Colorantes , Diseño Asistido por Computadora , Peróxido de Hidrógeno , Ácido Hipocloroso , Compuestos de Sodio
7.
BMC Oral Health ; 23(1): 543, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-37550631

RESUMEN

BACKGROUND: To study the effect of water storage (3 months) on the creep deformation of various CAD-CAM composite structures at the nanoscale and compare it to that at the macroscale. METHODS: Seven CAD-CAM blocks were investigated: five resin-composite blocks (RCB), one polymer-infiltrated ceramic network (PICN) block, and one ceramic-filled polyetheretherketone (PEEK) block. Specimens of each material (n = 6) were separated into two groups (n = 3) according to their storage conditions (24 h dry storage at 23˚C and 3 months storage in 37˚C distilled water). Nano-indentation creep measurements were undertaken (creep depth measured in µm) using a nanoindenter (Nanovea) equipped with Berkovich three-sided pyramidal diamond tip. The machine was set for the chosen parameters: a load of 20 gf, a pause of 20 s, and the material type. Thirty indentations on 3 samples were made for each material for each test. Data were analysed using two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests and independent t-test (< 0.05) for comparisons between the materials. RESULTS: The nanoindentation creep depth after 24 h storage ranged from 0.09 to 0.33 µm and increased after 3 months storage in distilled water to between 0.28 and 3.46 µm. There was a statistically significant difference in nanoindentation creep behaviour between the two storage conditions for each investigated material (independent t-test) and between all materials (Bonferroni post hoc). There was a non-significant negative correlation between nanoindentation creep (µm) and filler weight% at 24 h dry storage but a significant correlation at 3 months of water storage. A further non-significant positive correlation between nanoindentation creep (µm) and bulk compressive creep (%) was found. CONCLUSION: The PICN material showed superior dimensional stability in terms of nanoindentation creep depth in both storage conditions. Other composite blocks showed comparable performance at 24 h dry condition, but an increased nanoindentation creep upon water storage.


Asunto(s)
Cerámica , Agua , Humanos , Ensayo de Materiales , Resinas Compuestas/química , Diseño Asistido por Computadora , Propiedades de Superficie
8.
BMC Oral Health ; 23(1): 228, 2023 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-37081415

RESUMEN

BACKGROUND: To assess the antibacterial activity of multi-strain probiotics supernatants (MSP); Lactobacillus plantarum, Lactobacillus rhamnosus, and Lactobacillus acidophilus as an intracanal medication on Enterococcus faecalis (E. faecalis) biofilm in a tooth model. METHODS: Sixty extracted human single-rooted teeth with single canals were instrumented, sterilized, and inoculated with E. faecalis. After 21 days of incubation, four specimens were randomly selected to validate the biofilm formation by scanning electron microscope (SEM). The remaining specimens were randomly divided (n = 14), according to the intracanal medication (ICM) received into: Ca(OH)2: calcium hydroxide paste (35% Ultra Cal XS Ca(OH)2), Probiotics supernatants: MSP in poloxamer gel vehicle Poloxamer: poloxamer gel vehicle and, Control: E. faecalis biofilm only. The tested groups were further subdivided into two equal subgroups (n = 7) according to the incubation period (24 h and 7 days). Shaved dentin chips were obtained and collected by H-files and paper points, respectively for bacterial culture. The antibacterial activity was assessed after each incubation period quantitatively and qualitatively using bacterial colony-forming units per milliliter (CFUs/ml) and SEM, respectively. RESULTS: The lowest CFUs/ml was found in Ca (OH)2 with a significant difference compared to other groups after 24 h. After 7 days, a similar outcome was found with a further significant reduction of CFUs/ml in all groups with no statistical difference between Ca(OH)2 and probiotics supernatants groups. Ca (OH)2 and Probiotics supernatants groups showed a significant (p < 0.05) percentage of overall bacterial reduction (100.00 ± 0.00% and 70.30 ± 12.95%, respectively) compared to poloxamer and control groups (27.80 ± 14.45 and 28.29 ± 19.79). SEM images showed a bacteria-free state in the Ca(OH)2 group after 7 days while few bacteria were found in the probiotics supernatants group. An extensive invasion of bacteria was found in poloxamer and controls groups. CONCLUSION: MSP has a potential antibacterial effect on E. faecalis growth closely similar to the routinely used Ca (OH)2.


Asunto(s)
Clorhexidina , Enterococcus faecalis , Humanos , Poloxámero , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Bacterias , Biopelículas , Hidróxido de Calcio/farmacología , Hidróxido de Calcio/uso terapéutico , Irrigantes del Conducto Radicular , Cavidad Pulpar/microbiología
9.
Dent Mater ; 39(1): 123-131, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36577562

RESUMEN

OBJECTIVES: The aim of this study was to fractographically examine clinically fractured fixation screws used to fix implant supported restorations and to estimate stress at failure. METHODS: 20 clinically fractured titanium implant fixation screws were collected and analyzed under scanning electron microscope in order to locate critical crack origin and calculate stress at fracture. Principles of fractographic analysis were applied using relative equations and cause and conditions of screw fracture were calculated. X-rays and patients' records were collected after approval of necessary consent forms. RESULTS: Fractographic analysis revealed location and dimensions of critical crack size for every fractured screw examined. Two patterns of screw fracture were identified; the first was related to improper seating of fixation screw leading to damage at screw threads and eventual fracture of screw body. The second was related to slow crack growth propagation causing final fracture of screw body. The calculated stress at failure ranged from 755 to 804 MPa. Patients' records revealed that 75% of fractured screws were related to single unit screw retained restorations. SIGNIFICANCE: Single unit screw retained restorations and improperly seated implant abutments impose high stress concentration on fixation screw which may result in fixation screw fracture.


Asunto(s)
Implantes Dentales , Humanos , Fracaso de la Restauración Dental , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Tornillos Óseos
10.
Dent Mater ; 39(1): 57-69, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36496258

RESUMEN

OBJECTIVE: To investigate the effect of acidic media, including beverages and gastric fluids on flexural strength and fatigue of CAD-CAM materials. METHODS: Four CAD-CAM materials (high-translucency zirconia (Ceramill Zolid HT+), lithium disilicate (IPS e-max CAD), hybrid ceramic (Vita Enamic), and nanohybrid resin composite (Grandio Blocs) were prepared and immersed in one of five media (gastric HCl, white wine, Coca-Cola, orange juice, and artificial saliva) in an incubator (37 â„ƒ, 24 h). Surface topography and roughness were obtained using a scanning electron microscope (SEM) and a stylus contact profilometer, respectively. Initial 3-point flexural strength was measured for half of the bars (n = 20/gp) using a universal testing machine (0.5 mm/min). The other bars underwent 106 cyclic fatigue loadings before measurement of residual 3-point flexural strength. Data were statistically analyzed (two-way and three-way ANOVA, Tukey's post-hoc, p < 0.05). Weibull distributions were plotted for reliability analysis. RESULTS: Zirconia bars has the highest initial flexural strengths followed by lithium disilicate, while resin composite and hybrid ceramic groups had the lowest strength regardless of the erosive medium. Cyclic fatigue significantly reduced initial flexural strengths for all materials except for hybrid ceramic and resin composite. Weibull moduli were the highest for zirconia, lithium disilicate and resin composite and lowest for hybrid ceramic. SIGNIFICANCE: Erosive media significantly changed surface roughness of CAD-CAM materials except for zirconia and resin composite without jeopardizing the flexural strength of the CAD-CAM materials. Despite the higher flexural strengths for zirconia and lithium disilicate, resin composite and hybrid ceramic were more resistant to cyclic fatigue.


Asunto(s)
Materiales Dentales , Resistencia Flexional , Reproducibilidad de los Resultados , Ensayo de Materiales , Propiedades de Superficie , Porcelana Dental , Cerámica , Diseño Asistido por Computadora
11.
BMC Oral Health ; 22(1): 412, 2022 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-36123676

RESUMEN

BACKGROUND: Mechanical surface treatments can deteriorate the mechanical properties of zirconia. This study evaluated and compared the biaxial flexural strength, fracture toughness, and fatigue resistance of high translucency (HT) to low translucency (LT) zirconia after various mechanical surface treatments. METHODS: Four hundred eighty zirconia discs were prepared by milling and sintering two HT (Katana and BruxZir) and LT (Cercon and Lava) zirconia blocks at targeted dimensions of 12 mm diameter × 1.2 mm thickness. Sintered zirconia discs received one of the following surface treatments: low-pressure airborne particle abrasion (APA) using 50 µm alumina particles, grinding using 400 grit silicon carbide paper, while as-sintered specimens served as control. Internal structure and surface roughness were evaluated by scanning electron microscope (SEM) and a non-contact laser profilometer, respectively. Half of the discs were tested for initial biaxial flexural strength, while the rest was subjected to 106 cyclic fatigue loadings, followed by measuring the residual biaxial flexural strength. Fractured surfaces were examined for critical size defects (c) using SEM to calculate the fracture toughness (KIC). The effect of surface treatments, zirconia type, and cyclic fatigue on the biaxial flexural strength was statistically analyzed using three-way analysis of variance (ANOVA) and Tukey HSD post hoc tests (α = 0.05). Weibull analysis was done to evaluate the reliability of the flexural strength for different materials. RESULTS: The initial biaxial flexural strength of LT zirconia was significantly higher (p < 0.001) than that of HT zirconia in all groups. While low APA significantly increased the biaxial flexural strength of LT zirconia, no significant change was observed for HT zirconia except for Katana. Surface grinding and cyclic fatigue significantly reduced the flexural strength of all groups. High translucency zirconia reported higher fracture toughness, yet with lower Weibull moduli, compared to LT zirconia. CONCLUSION: LT zirconia has higher biaxial flexural strength, yet with lower fracture toughness and fatigue resistance, compared to HT zirconia. Low-pressure APA has significantly increased the biaxial flexural strength in all zirconia groups except BruxZir. Grinding was deteriorating to biaxial flexural strength and fracture toughness in all zirconia types. Cyclic fatigue has significantly decreased the biaxial flexural strength and reliability of HT and LT zirconia.


Asunto(s)
Óxido de Aluminio , Resistencia Flexional , Humanos , Ensayo de Materiales , Reproducibilidad de los Resultados , Circonio
12.
BMC Oral Health ; 22(1): 191, 2022 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-35590294

RESUMEN

BACKGROUND: Erosive acids might create surface flaws and deteriorate the mechanical properties of CAD-CAM materials. This invitro study aimed to investigate the effect of simulated gastric HCl and extrinsic erosive acids on surface microhardness and fracture toughness of CAD-CAM materials. METHODS: 400 bar-shaped specimens (17×4×2 mm3) were prepared from 4 different CAD-CAM dental materials (n = 100/group); monolithic zirconia (Ceramill Zolid HT+, Amanngirbach, Austria), lithium disilicate ceramic (IPS e.max CAD, Ivoclar Vivadent, Liechtenstein), nanohybrid resin composite (Grandio Blocs, VOCO) and polymer-infiltrated glass network (Vita Enamic, VITA Zahnfabrik). Specimens from each material type were further subdivided into 5 groups (n = 20) according to the erosive media applied (simulated gastric HCl, white wine, Coca-Cola®, orange juice, and artificial saliva that served as a control). Specimens were immersed for 24 h in an incubator at 37 ℃, then ultrasonically cleaned in distilled water and air-dried. Half of the specimens were tested for Vickers microhardness (VHN) at parameters of 500 gf for 10 s, while the rest of the specimens underwent 3-point flexure till fracture. Fractured surfaces were examined under a scanning electron microscope (SEM) for fracture toughness (KIC) calculation using the quantitative fractographic analysis method. Data collected were statistically analyzed using two-way analysis of variance (α = 0.05) after verification of data normality and homogeneity of variances. RESULTS: Erosive media created surface flaws that lowered the surface microhardness of the material and initiated the fracture pattern under different loads according to material type. The material type was a more predominant factor than erosive media that affected either the microhardness or the fracture toughness of CAD-CAM dental materials. The highest VHN and KIC values were found among Ceramill Zolid HT+ groups followed by IPS e.max CAD and Grandio Blocs regardless of the erosive media employed. Erosive media significantly reduced the VHN and KIC in Vita Enamic specimens compared to the rest of the material types. CONCLUSION: All CAD-CAM materials used, except Vita Enamic, showed high resistance against the erosive acids indicating higher longevity of the material in patients frequently exposed to either extrinsic or intrinsic acid.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Materiales Dentales , Humanos , Ensayo de Materiales , Propiedades de Superficie
13.
Polymers (Basel) ; 14(8)2022 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-35458269

RESUMEN

This study aimed to evaluate the colour stability of polymethyl methacrylate (PMMA) denture base reinforced with ZrO2 nanoparticles, E-glass fibres, and TiO2 nanoparticles at various concentrations over 180-day storage in Steradent™ (STD) denture cleaner or coffee (CF). A total of 130 disc-shaped specimens were fabricated at various filler concentrations and divided into four main groups to measure the colour changes. Groups Z, T, and E consisted of PMMA reinforced with ZrO2 nanoparticles, TiO2 nanoparticles, or E-glass fibre, respectively, while Group C consisted of PMMA specimens without filler served as the control group (n = 10). The three reinforced groups were further subdivided according to the filler content (n = 10) added to the PMMA (1.5%, 3.0%, 5.0%, and 7.0% wt.%). Half of the specimens were stored in STD, while the other half was stored in CF for 180 days. A Minolta Chroma Meter was used to measure the colour changes (ΔE) at 7, 30, 90 and then 180 days. The results were assessed using two-way repeated-measures analysis of variance (RM-ANOVA) along with Bonferroni post hoc tests at a p ≤ 0.05 significance level. Significant different colour changes (ΔΕ) were observed between all tested groups and across different time points. TiO2-reinforced PMMA in STD/CF showed the lowest colour stability, while the E-glass fibre-reinforced PMMA in STD/CF showed the highest colour stability. Furthermore, coffee appeared to have the greatest impact on the colour change in comparison to the SteradentTM. The results indicated that the filler type and concentration, type of solution, and length of storage all affected the colour stability of the tested specimens.

14.
Materials (Basel) ; 14(6)2021 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-33802778

RESUMEN

Zirconia repair could be a feasible alternative option to total replacement in fractured zirconia-based restorations. Maximising the bond strength by enriching zirconia with fluorapatite glass-ceramics (FGC) powder has been addressed and compared to other surface treatments. Besides resin composite, other repair materials have been proposed and compared. Zirconia blocks received different surface treatments (A-sandblasting with tribochemical silica-coated alumina (CoJet). B-sandblasting with FGC powder (FGC), C-fluorapatite glass-ceramic coat+ neodymium-doped yttrium aluminum garnet laser irradiation (FGC + Nd: YAG), and D-no surface treatment). The surface roughness, topography, and crystallinity were investigated by a profilometer, scanning electron microscopy (SEM), and X-ray diffraction (XRD) analyses, respectively. For each surface treatment, three repair materials (feldspathic porcelain, lithium disilicate, and resin composite) were bonded to zirconia with 10, Methacryloyloxydecyl dihydrogen phosphate (MDP)-Monobond Plus/ Multilink Automix. Bonded specimens were thermocycled for 10,000 cycles and tested for shear bond strength (SBS) at a speed of 1 mm/min, followed by the analysis of the mode of failure. FGC + Nd: YAG laser group reported the highest surface roughness and monoclinic content compared to CoJet, FGC, and control groups. The highest mean SBS was found in FGC-blasted zirconia, followed by FGC + Nd: YAG laser and CoJet treated groups. However, the lowest SBS was found in control groups regardless of the repair material. Sandblasting zirconia with FGC powder increased SBS of resin to zirconia with lower monoclinic phase transformation compared to FGC + Nd: YAG or CoJet groups.

15.
Dent Mater ; 37(5): 905-913, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33691991

RESUMEN

OBJECTIVES: To evaluate the effect of laser fused and air abraded fluorapatite particles on flexural strength σf and fracture toughness (KIC) of Yttria tetragonal zirconia polycrystal (Y-TZP). METHODS: 160 polished Y-TZP bars received one of the following surface treatments: airborne particle abrasion (APA) with fluorapatite glass-ceramics (FGC), APA with tribochemical silica-coated alumina (CoJet), laser fused FGC using Nd:YAG Laser (FGC + Laser), while as-sintered polished specimens served as control. Initial flexural strength σfI was measured to half of the specimens, while the rest underwent cyclic fatigue (1,000,000 cycle of 15N load and 3 s contact time) followed by measuring residual flexural strength σfR. Fractographic analysis was performed and KIC was calculated. The effect of surface treatment and fatigue on flexural strength was statistically analysed using 2-way ANOVA (α = 0.05). Weibull probability was measured to assess the reliability of flexural strength. RESULTS: The highest σf before or after the fatigue was reported for the control group while the lowest was for FGC + Laser group. Cyclic fatigue significantly decreased the flexural strength of all groups except for FGC + Laser group. There was no significant difference between the KIC between the control and FGC groups, however, a significant reduction of KIC was found in the CoJet group, while FGC + Laser reported the significant lowest value compared to all groups (P = 0.00). SIGNIFICANCE: Fluorapatite glass-ceramic powder offers a promising alternative for particle abrasion of zirconia-based frameworks.


Asunto(s)
Materiales Dentales , Circonio , Cerámica , Análisis del Estrés Dental , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Itrio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA