Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 30(1): 78-86, 2011 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-21944924

RESUMEN

An optical waveguide array biosensor suitable for rapid detection of multiple bio-hazardous agents is presented. SpectroSens™ optical microchip sensors contain multiple spatially-separated waveguide channels with integral high-precision Bragg gratings sensitive to changes in refractive-index; selective surface-functionalisation of discrete sensing channels with different antibodies as bio-recognition elements enables selective multi-analyte biological detection. Interactions between target antigens in the test sample and respective surface-immobilised antibodies result in localised changes in refractive-index; the biosensor response manifests as increases in wavelength of light reflected from specific sensing channels. Multiplexed, label-free detection of 8 different biological agents, encompassing bacterial spores, vegetative cells, viruses and proteinaceous toxins has been demonstrated in real-time. Selective detection of Bacillus atrophaeus (BG) spores, Escherichia coli cells, MS2 viruses and ovalbumin (OVA) protein (simulant bio-hazardous agents) was first demonstrated as proof-of-concept; subsequently, detection of Bacillus anthracis (BA) spores (UM23CL2 strain), Franciscella tularensis (FT) cells (live vaccine strain), Vaccinia viruses (heat-killed) and ricin toxin (bio-hazardous agents) was proven. Two optical microchip sensors, each comprising 8 sensing channels were packaged into a single disposable cartridge allowing simultaneous 16-channel data acquisition. The specific antibody deposition sequence used in this study enabled detection of either 4 simulants or 4 bio-hazardous agents using a single consumable. The final device, a culmination of the multidisciplinary convergence of the fields of biology, chemistry, optoelectronics and microfluidics, is man-portable and inherently robust. The performance characteristics of the SpectroSens™ technology platform highlight its potential for exploitation as a 'detect to warn/treat' biodetector in security and defence operations.


Asunto(s)
Técnicas Biosensibles/instrumentación , Mezclas Complejas/análisis , Equipos Desechables , Sustancias Peligrosas/análisis , Inmunoensayo/instrumentación , Análisis por Micromatrices/instrumentación , Refractometría/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo
2.
J Immunol Methods ; 362(1-2): 121-6, 2010 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-20850447

RESUMEN

A rapid, label-free optical biosensor system for sensitive monitoring of bio-molecular interactions in real-time is presented. SpectroSens sensor chips are based on integrated planar Bragg gratings sensitive to localised changes in refractive index. Bio-molecule recognition is imparted by functionalisation of the sensing surface with antibodies against targets of interest. In this study, antibodies against selected proteins were oriented with recombinant Protein A/G, which was covalently immobilised to the sensor chip via amine coupling to a glutaraldehyde-activated silane layer. Immunoassays for the detection of rabbit IgG and ovalbumin proteins as model antibody-antigen interaction systems were performed. Binding of complementary antigens to respective antibody-functionalised sensors manifested as changes in wavelength of light reflected from the optical sensors. Quantitative binding kinetics with detection sensitivities in the mid ng/ml range were obtained for both antigens using this planar, two-dimensional surface coating. Data presented demonstrate the suitability of SpectroSens sensors as a valuable tool in life science research and development for monitoring bio-specific interactions, protein concentration determination and antibody selection; the optical integration and analytical characteristics of these sensors suggest that they may find numerous applications in bio-pharmaceutical development and clinical diagnostics.


Asunto(s)
Anticuerpos/análisis , Antígenos/análisis , Proteínas Bacterianas/química , Técnicas Biosensibles/métodos , Análisis por Matrices de Proteínas/métodos , Proteína Estafilocócica A/química , Animales , Cabras , Conejos , Sensibilidad y Especificidad
3.
Opt Lett ; 32(11): 1542-4, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17546182

RESUMEN

We demonstrate liquid-crystal-based integrated optical devices with >140 GHz electrical tuning for potential applications in dynamic optical networks. Bragg wavelength tuning covering five 25 GHz wavelength-division multiplexing channel spacing has been achieved with 170 V (peak-to-peak) sinusoidal voltages applied across electropatterned indium tin oxide-covered glass electrodes placed 60 microm apart. This tunability range was limited only by the initial grating strength and supply voltage level. We also observed two distinct threshold behaviors that manifest during increase of supply voltage, resulting in a hysteresis in the tuning curve for both TE and TM input light.

4.
Opt Lett ; 29(9): 947-9, 2004 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15143636

RESUMEN

A waveguide laser with a neodymium-doped silica core is fabricated on a silicon substrate by a combination of flame hydrolysis deposition, solution doping, and direct UV writing. The neodymium-ion concentration is estimated to be approximately 8000 parts in 10(5). The propagation loss around 1.05 microns is < 0.8 dB/cm. Lasing in the range 1048-1056 nm and 1356 +/- 1 nm is observed. A slope efficiency of 33% for a high-reflectivity output coupler and a threshold of 4 mW of absorbed power for a 25% output coupler are measured for the 4F3/2-->4I11/2 transition.

5.
Hum Reprod ; 12(6): 1360-3, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9222030

RESUMEN

This paper describes the first pregnancy in a childless widow after intracytoplasmic sperm injection (ICSI) treatment with her deceased husband's spermatozoa which had been stored for nearly 3 years before use. Before his death the husband had received treatment for testicular cancer and he had given the appropriate written consent for the future use of his spermatozoa. Of the 10 eggs injected, six resulted in normal embryos. Three embryos were transferred and the remaining three embryos are currently stored for possible future use. The treatment resulted in a continuing singleton pregnancy. The case demonstrated the suitability of ICSI in those difficult cases where the sperm quality is extremely poor. This success is also compared with a widely debated case of another widow who was refused permission to use her deceased husband's spermatozoa. It is concluded that in the case of posthumous use of frozen spermatozoa, the current laws are conveniently applicable in a chronic illness but not so in an acute illness leading to death. In the light of the wide public debate on the issues raised by this legal case, the UK Government has also decided to conduct a review of consent procedures involving the storage and use of genetic material.


Asunto(s)
Ética Médica , Fertilización In Vitro/legislación & jurisprudencia , Fertilización In Vitro/métodos , Espermatozoides , Viudez , Criopreservación , Citoplasma , Femenino , Humanos , Consentimiento Informado/legislación & jurisprudencia , Masculino , Microinyecciones , Embarazo , Política Pública , Semen , Reino Unido
6.
Br Heart J ; 39(5): 569-72, 1977 May.
Artículo en Inglés | MEDLINE | ID: mdl-861101

RESUMEN

Two cases of symmetrical peripheral gangrene associated with intracardiac lesions are described. One had a secondary deposit from a uterine leiomyosarcoma in the wall of the right ventricle, the other had a free ball thrombus in the right atrium; there were no valvular lesions in either case. The published reports of this type of gangrene indicate that it may result from (1) va sospastic conditions, (2) small vessel obstruction, or (3) conditions producing a very low cardiac output. The two patients reported are unusual examples of the last.


Asunto(s)
Gangrena/etiología , Neoplasias Cardíacas/complicaciones , Leiomiosarcoma/complicaciones , Trombosis/complicaciones , Anciano , Femenino , Gangrena/patología , Atrios Cardíacos/patología , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA