Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
2.
Interv Cardiol Clin ; 13(2): 207-216, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432763

RESUMEN

Reintervention is commonly required postsurgical mitral valve replacement (SMVR) or repair due to bioprosthetic valve and annuloplasty ring degeneration. However, redo SMVR is associated with a high risk of morbidity and mortality. Postsurgical transcatheter mitral valve replacement (TMVR) is a safe and less-invasive alternative that has repeatedly been shown to be associated with improved survival and lower rates of complications compared with redo SMVR. Comprehensive patient evaluation and thorough procedural planning are key to successful TMVR.


Asunto(s)
Catéteres , Válvula Mitral , Humanos , Válvula Mitral/cirugía
3.
Interv Cardiol Clin ; 13(2): 227-235, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432765

RESUMEN

Mitral valve dysfunction is prevalent amongst older patients. Of those not suitable for surgical therapy, mitral transcatheter edge-to-edge repair (TEER) can treat as large proportion of patients, many are not suitable TEER candidates. As such, orthotopic transcatheter mitral valve replacement (TMVR) is an important innovation but it faces significant challenges. Orthotopic TMVR requires a prosthesis with stable anchoring, adequate sealing, minimal footprint in the left ventricle and long term durability. Multidisciplinary expertise in advanced imaging, surgery, heart failure are needed for success.


Asunto(s)
Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ventrículos Cardíacos , Implantación de Prótesis
4.
Interv Cardiol Clin ; 13(2): xiii-xiv, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432771
5.
Interv Cardiol Clin ; 12(4): ix, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37673501
7.
Interv Cardiol Clin ; 12(3): xi, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37290847
8.
Cardiovasc Revasc Med ; 55: 99-100, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37290992

RESUMEN

Mitral valve endocarditis complicated by peri-mitral annular destruction requires surgical intervention. We present a case where surgery was not an option. A 45-year-old man who developed an enlarging left ventricle pseudoaneurysm, left ventricle to left atrium fistula and red blood cell hemolysis as sequalae of mitral valve endocarditis was not a surgical candidate. Patient underwent a hybrid repair of left ventricle pseudoaneurysm via a transapical and transseptal approach. The body of pseudoaneurysm was coiled trans-apically whereas the neck of pseudoaneurysm was reached and coiled via a transseptal approach. The left ventricle to left atrium fistula was closed via an Amplatz muscular ventricle septal occluder. The pseudoaneurysm was fully obliterated, patient symptoms improved and was discharged with stable hemoglobin levels.


Asunto(s)
Aneurisma Falso , Endocarditis , Fístula , Estenosis de la Válvula Mitral , Masculino , Humanos , Persona de Mediana Edad , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Aneurisma Falso/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Fístula/complicaciones
9.
Interv Cardiol Clin ; 12(2): xiii, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36922070
11.
Interv Cardiol Clin ; 12(1): xiii, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36372466
12.
J Thorac Cardiovasc Surg ; 165(6): 2011-2020.e5, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-34538638

RESUMEN

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement since its approval, the frequency and outcomes of aortic valve reintervention after transcatheter aortic valve replacement are poorly understood. METHODS: Valve reinterventions, either surgical transcatheter aortic valve explantation or repeat transcatheter aortic valve replacement, between 2012 and 2019 were queried using the Society of Thoracic Surgeons Database and the Transcatheter Valve Therapy Registry through the Michigan Statewide quality collaborative. The reintervention frequency and clinical outcomes including observed-to-expected mortality ratio using Society of Thoracic Surgeons Predicted Risk of Mortality were reviewed. RESULTS: Among 9694 transcatheter aortic valve replacement recipients, a total of 87 patients (0.90%) received a reintervention, consisting of 34 transcatheter aortic valve explants and 53 repeat transcatheter aortic valve replacement procedures. The transcatheter aortic valve explant group demonstrated a higher Society of Thoracic Surgeons Predicted Risk of Mortality. Reintervention cases increased from 0 in 2012 and 2013 to 26 in 2019. The proportion of transcatheter aortic valve explants among all reinterventions increased and was 65% in 2019. Self-expandable devices had a higher reintervention rate than balloon-expandable devices secondary to a higher transcatheter aortic valve explant frequency (0.58% [23/3957] vs 0.19% [11/5737]; P = .001), whereas repeat transcatheter aortic valve replacement rates were similar (0.61% [24/3957] vs 0.51% [29/5737]; P = .51). Among patients with transcatheter aortic valve explants, contraindications to repeat transcatheter aortic valve replacement included unfavorable anatomy (75%), need for other cardiac surgery (29%), other structural issues by transcatheter aortic valve device (18%), and endocarditis (12%). For transcatheter aortic valve explant and repeat transcatheter aortic valve replacement, the 30-day mortality was 15% and 2% (P = .032) and the observed-to-expected mortality ratio was 1.8 and 0.3 (P = .018), respectively. CONCLUSIONS: Aortic valve reintervention remains rare but is increasing. The clinical impact of surgical device explantation was substantial, and the proportion of transcatheter aortic valve explants was significantly higher in patients with a self-expandable device.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Factores de Riesgo
13.
Interv Cardiol Clin ; 11(4): xi, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36243492
14.
15.
Catheter Cardiovasc Interv ; 100(5): 890-900, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35971750

RESUMEN

OBJECTIVE: To describe outcomes of patients who underwent transcatheter aortic valve replacement (TAVR) in a native valve or failed bioprosthetic valve or transcatheter heart valve (THV) and a transcatheter mitral valve replacement procedure (TMVR; valve-in-valve [mViV], valve-in-ring [mViR], and valve in mitral annulus calcification [ViMAC]) either concomitantly (same procedure) or staged (different procedures). BACKGROUND: Patient characteristics, procedural details, and outcomes of concomitant or staged TAVR and TMVR procedures are largely unknown. METHODS: Data were extracted from the STS/ACC TVT Registry™ for patients undergoing concomitant or staged TAVR and TMVR with SAPIEN XT, SAPIEN 3, or SAPIEN 3 Ultra (Edwards Lifesciences) THVs. Descriptive results were reported for procedural, index hospitalization, 30-day, and 1-year outcomes. RESULTS: A total of 257 patients underwent TAVR and TMVR in concomitant (n = 135) or staged (n = 122) procedures. Device success was 82.9% and 83.9% for concomitant TAVR and TMVR procedures and 83.8% and 82.5% for staged TAVR and TMVR procedures. Significant improvements in aortic and mitral valve function remained stable through 1 year. All-cause mortality for concomitant and staged groups was 14.7% and 10.5% at 30 days, and 32.8% and 24.6% at 1 year, respectively. Stroke rate for concomitant and staged groups was 0.8% and 3.6% at 30 days and 3.9% and 5.6% at 1 year, respectively. Improvements from baseline to 1 year in NYHA class and KCCQ overall summary scores were observed for all patients. CONCLUSIONS: Concomitant or staged transcatheter treatment of patients with aortic and mitral valve disease can be performed in select high-risk patients in experienced centers.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Factores de Tiempo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
16.
Curr Cardiol Rep ; 24(10): 1417-1424, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35980565

RESUMEN

PURPOSE OF REVIEW: Repeat surgery for failed mitral valve prostheses and repairs are fraught with high rates of morbidity and mortality. Therefore, clinicians have evolved transcatheter technology as an alternative therapy. This review serves as an update as the field has moved out of the early learning curve of treating postsurgical mitral valve failures. RECENT FINDINGS: Mitral valve-in-valve procedures have higher rates of technical success and better in-hospital and 1-year mortality rates than mitral valve-in-ring cases. The higher rates of complications, including left ventricular outflow tract obstruction, paravalvular leak, valve embolization, and need for a 2nd valve, may explain these outcomes. Mitral valve-in-ring procedures have attenuated outcomes as compared to valve-in-valve. Clinicians should be cognizant of the nuanced complexities and the potential for suboptimal outcomes in using balloon-expandable valves for mitral valve-in-ring procedures.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis , Falla de Prótesis , Instrumentos Quirúrgicos , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 100(4): 628-635, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35900207

RESUMEN

OBJECTIVES: To study the safety and efficacy of AngioVac for left-sided transcatheter vacuum-assisted mass extraction (TVME). BACKGROUND: The AngioVac system is approved for right-sided TVME and has emerged as an effective and safe alternative for open surgical treatment. The use of the AngioVac device for aspiration of left-sided TVME has been limited. METHODS: Consecutive patients from two Michigan centers who underwent left-sided TVME were included. Data on patient demographics, procedural information, in-hospital and follow-up events were collected through electronic medical records review. Technical success was defined as aspirating of 70%-100% of the material. RESULTS: Ten patients (mean age 58.3 [±17.3] years, 50% male) were included. Indications for TMVE were in large for recurrent embolic events. All patients underwent bilateral cerebro-embolic protection using the Sentinel device. The total mean procedure time was 192.5 (±47.5) min of which the meantime for active aspiration (bypass time) was 9.3 (±4.2) min. The circuit configuration was: arteriovenous (AV) in four cases and arterioarterial (AA) in six cases. Successful aspiration was achieved in 80% of cases. No complications were reported (range follow-up 1-16 months). CONCLUSIONS: Our small case series demonstrates the feasibility and safety of the AngioVac system in left-sided mass extraction. Larger trials are needed to further demonstrate its effectiveness and safety and potentially apply for on-label use.


Asunto(s)
Trombectomía , Femenino , Humanos , Masculino , Michigan , Persona de Mediana Edad , Trombectomía/efectos adversos , Resultado del Tratamiento , Vacio
19.
Cardiovasc Revasc Med ; 45: 44-50, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35882600

RESUMEN

INTRODUCTION: Acute MR due to mechanical mitral valve (MV) complications frequently results in cardiogenic shock and requires emergency surgical intervention. There was limited evidence for alternative treatment like MitraClip for patients at prohibitive surgical risk. We aimed to study the technical features and outcomes of emergency transcatheter edge-to-edge repair (TEER) using the MitraClip system for patients with cardiogenic shock (CS) secondary to acute mitral regurgitation (MR) and mechanical MV complication. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all TEER for CS patients due to acute mitral regurgitation and mechanical MV complication. Clinical endpoints included device success rate assessed at the end of procedure, ability to wean off MCS, all-cause and cardiovascular mortality at 30-day. RESULTS: Eight patients were identified from institutional review. Detail anatomical analysis found that patients with mechanical MV complications related to myocardial infarction had a lower transseptal height achieved during MitraClip (3.6 ± 0.1 cm vs 4.3 ± 0.3 cm, p = 0.03) than those not related. Pooled analysis for cases from institutional review (n = 8) and systemic literature review (n = 16) was performed. The device success rate was 68.8 %. Seventy-five percent (n = 18) cases required mechanical circulatory support (MCS), and 94.4 % were able to wean off MCS. At 30-day, the cardiovascular mortality was 4.5 % and the all-cause mortality was 9.1 %. CONCLUSIONS: In CS patients due to acute MR and mechanical MV complications, TEER with/without MCS was feasible with a reasonable device success rate.


Asunto(s)
Choque Cardiogénico , Humanos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
20.
Interv Cardiol Clin ; 11(3): 233-243, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35710279

RESUMEN

Paravalvular leaks (PVLs) are challenging lesions that require a comprehensive understanding of surgical and transcatheter heart therapies, multimodality imaging, and transcatheter techniques. Approach to a transcatheter heart valve (THV) or surgical prosthesis for PVL differs in terms of options and varies according to the location (aortic or mitral). A suggested framework for transcatheter PVL repair is defect localization, access planning, defect crossing, sheath delivery. and occluder deployment. Careful planning facilitates success, but operators begin the case with a flexible mindset because many initial strategies may not succeed.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Imagen Multimodal , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...