Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiol Case Rep ; 18(3): 1037-1040, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36684636

RESUMEN

Stanford type B aortic dissection (TBAD) is a potentially fatal condition involving a tear in the descending aorta. As TBAD can be managed with medical therapy or surgical repair, identifying predictors of adverse outcomes is important to risk-stratify patients for preemptive surgical procedures. 4D flow magnetic resonance imaging (MRI) has shown to be useful in characterizing the complex hemodynamics seen in TBAD patients and correlating flow patterns with adverse outcomes. We report a case of a 58-year-old man who presented to the hospital with acute TBAD and a large primary entry tear. He was initially managed with medical therapy due to his stable clinical status and computed tomographic angiography showing a stable dissection. However, 4D flow MRI showed high velocity flow through the entry tear, which foreshadowed the later clinical decompensation of the patient. Our case demonstrates that performing 4D flow MRI on TBAD patients is feasible and can provide valuable information in the decision to pursue medical or surgical management.

2.
J Magn Reson Imaging ; 57(6): 1752-1763, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36148924

RESUMEN

BACKGROUND: 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD). PURPOSE: To investigate CS-accelerated 4D Flow MRI performance compared to GRAPP-accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD. STUDY TYPE: Prospective. POPULATION: Twelve TBAD patients, two volunteers. FIELD STRENGTH/SEQUENCE: 1.5T, 3D time-resolved cine phase-contrast gradient echo sequence. ASSESSMENT: GRAPPA (acceleration factor [R] = 2) and two CS-accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane-based mid-lumen flows were quantified. Imaging times were recorded. TESTS: Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance. RESULTS: The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781-0.986]), and low to strong in FL (r = [0.347-0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732-0.989). The FF and net flow in mid-descending aorta TL were significantly different between CS7.7 and CS10.2. CONCLUSION: CS-accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS-acceleration impacts KE, FF, RF, and stasis more in FL. EVIDENCE LEVEL: 1 Technical Efficacy: Stage 2.


Asunto(s)
Disección Aórtica , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Velocidad del Flujo Sanguíneo/fisiología , Imagen por Resonancia Magnética/métodos , Disección Aórtica/diagnóstico por imagen , Hemodinámica , Imagenología Tridimensional/métodos
3.
J Card Surg ; 37(11): 3899-3903, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36116051

RESUMEN

BACKGROUND: The hemispherical aortic annuloplasty reconstructive technology (HAART) is an internal geometric annuloplasty ring designed to restore a natural elliptical shape to the aortic annulus as part of aortic valve repair. We present four-dimensional flow hemodynamic analysis before and after implementation of the HAART ring in patients undergoing ascending aortic replacement. METHODS: Aortic hemodynamics over the cardiac cycle were visualized using time-resolved three-dimensional pathlines. Velocity streamlines tangent to the time-resolved velocity vector field were used to demonstrate instantaneous aortic hemodynamics. Peak velocities, forward and retrograde flow were calculated at nine planes placed along the midline of the thoracic aorta. Systolic wall shear stress and peak viscous energy loss over the cardiac cycle were calculated. RESULTS: HAART patients displayed similar or improved flow profiles after surgery when compared to a patient undergoing ascending aortic replacement alone. CONCLUSION: There may be a trend towards improved flow dynamics in patients undergoing HAART ring implantation.


Asunto(s)
Terapia Antirretroviral Altamente Activa , Válvula Aórtica , Aorta/cirugía , Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo , Hemodinámica , Humanos , Espectroscopía de Resonancia Magnética , Tecnología
4.
Urology ; 105: e9-e10, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28408339

RESUMEN

A 78-year-old woman presented to the urology clinic with a large, symptomatic left-sided abdominal cyst that was believed to be renal in etiology for many years and that had been percutaneously drained 3 times previously with persistent regrowth. The patient underwent laparoscopic resection of this mass, which proved to be a completely distinct retroperitoneal cystic structure and was not renal in nature. Pathologic analysis ultimately revealed a rare occurrence: a benign retroperitoneal Müllerian serous cystadenoma. To our knowledge, this is the first report of such an entity "disguised" as a renal cyst.


Asunto(s)
Cistadenoma Seroso/diagnóstico , Enfermedades Renales Quísticas/diagnóstico , Conductos Paramesonéfricos/patología , Neoplasias Retroperitoneales/diagnóstico , Anciano , Cistadenoma Seroso/cirugía , Diagnóstico Diferencial , Femenino , Humanos , Enfermedades Renales Quísticas/cirugía , Laparoscopía , Neoplasias Retroperitoneales/cirugía , Tomografía Computarizada por Rayos X
6.
PLoS One ; 10(4): e0121254, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25853491

RESUMEN

Avian host life history traits have been hypothesized to predict rates of infection by haemosporidian parasites. Using molecular techniques, we tested this hypothesis for parasites from three haemosporidian genera (Plasmodium, Haemoproteus, and Leucocytozoon) collected from a diverse sampling of birds in northern Malawi. We found that host life history traits were significantly associated with parasitism rates by all three parasite genera. Nest type and nest location predicted infection probability for all three parasite genera, whereas flocking behavior is an important predictor of Plasmodium and Haemoproteus infection and habitat is an important predictor of Leucocytozoon infection. Parasite prevalence was 79.1% across all individuals sampled, higher than that reported for comparable studies from any other region of the world. Parasite diversity was also exceptionally high, with 248 parasite cytochrome b lineages identified from 152 host species. A large proportion of Plasmodium, Haemoproteus, and Leucocytozoon parasite DNA sequences identified in this study represent new, previously undocumented lineages (n = 201; 81% of total identified) based on BLAST queries against the avian malaria database, MalAvi.


Asunto(s)
Biodiversidad , Aves/crecimiento & desarrollo , Aves/parasitología , Haemosporida/clasificación , Haemosporida/fisiología , Interacciones Huésped-Parásitos , Estadios del Ciclo de Vida , Animales , Conducta Animal , Enfermedades de las Aves/transmisión , Vectores de Enfermedades , Ecosistema , Prevalencia , Infecciones Protozoarias en Animales/transmisión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...