Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 9(1): 16976, 2019 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-31740683

RESUMEN

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 µW whereas the power of the AC-HBT ranges from 1 to 20 µW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/[Formula: see text] range. The charge sensitivity for the CB-HBT and AC-HBT is 330 µe/[Formula: see text] and 400 µe/[Formula: see text], respectively. For the single-shot readout performed, less than 10 µs is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

2.
Rev Sci Instrum ; 89(10): 10G125, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399712

RESUMEN

Crystal x-ray imaging is frequently used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. However, currently used x-ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single-line-of-sight x-ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns-scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single-line-of-sight with high spatial and temporal resolution. At the moment, the instrument can record two single-line-of-sight images with spatial and temporal resolution of 35 µm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single-line-of-sight camera for the NIF, including the x-ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...