Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am Surg ; 67(9): 865-7, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11565765

RESUMEN

Traumatic hepatic arterioportal fistulae (APF) are described infrequently as sequelae of hepatic trauma. These anomalies are usually associated with blunt hepatic trauma or iatrogenic injury. The majority of APF present within weeks to months of injury with gastrointestinal hemorrhage, hemobilia, abdominal pain, and diarrhea. When presenting remotely APFs are associated with portal hypertension, heart failure, gastrointestinal hemorrhage, ascites, and splenomegaly. We report an unusual case of mesenteric ischemia due to an APF that resulted from a penetrating liver injury 20 years before presentation. Successful treatment of the APF was achieved by intravascular catheter occlusion resulting in resolution of symptoms.


Asunto(s)
Fístula Arteriovenosa/complicaciones , Arteria Hepática , Isquemia/etiología , Hígado/lesiones , Mesenterio/irrigación sanguínea , Vena Porta , Heridas Punzantes/complicaciones , Adulto , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/etiología , Fístula Arteriovenosa/terapia , Embolización Terapéutica , Arteria Hepática/diagnóstico por imagen , Humanos , Isquemia/diagnóstico por imagen , Masculino , Mesenterio/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Radiografía
2.
Ann Thorac Surg ; 71(3): 1008-10, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11269412

RESUMEN

We observed a case of anomalous origin of the left pulmonary artery from the aorta in which the media of the abnormal vessel and the main pulmonary artery were fused, but without communication. This is the fifth isolated case of repair without the use of cardiopulmonary bypass reported in the literature. This pathology should be included in the aortic arch anomalies as a partial or complete failure of development of the left sixth arch.


Asunto(s)
Anomalías Múltiples , Aorta Torácica/anomalías , Arteria Pulmonar/anomalías , Anomalías Múltiples/embriología , Aorta Torácica/embriología , Humanos , Recién Nacido , Masculino , Arteria Pulmonar/embriología
3.
Am J Surg ; 180(6): 512-5; discussion 515-6, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11182409

RESUMEN

BACKGROUND: Aminoglycosides can cause nephrotoxicity and ototoxicity. Alternatives are available. METHODS: Surgical service antibiotic use, aminoglycoside toxicity, and perioperative culture/sensitivity results from July 1998 to June 1999 were reviewed. RESULTS: Of 289 positive cultures in 243 patients, 92 cultures (32%) grew 151 Gram-negative rods (GNRs). Aminoglycosides were used in 26 patients and 4 of 26 (15%) suffered nephrotoxicity. Of the 112 GNRs tested against ceftazidime, 111 (99%) were sensitive to it which was significantly better than amikacin (56 of 61, 92%, P = 0.038), gentamicin (116 of 134, 87%, P <0.001), and tobramycin (67 of 81, 83%, P <0.001). The proportion sensitive to cefuroxime (26 of 30, 87%) was equivalent to the proportions sensitive to gentamicin (87%, P = NS) and tobramycin (83%, P = NS). Of the 35 GNRs that were resistant to gentamicin and/or tobramycin, 15 (43%) were Pseudomonas aeruginosa. CONCLUSION: Aminoglycosides produce a significant rate of nephrotoxicity. There are antibiotics with equal or better sensitivity profiles than aminoglycosides against GNRs and Pseudomonas. Aminoglycoside use is rarely, if ever, indicated.


Asunto(s)
Antibacterianos/efectos adversos , Infecciones por Bacterias Gramnegativas/tratamiento farmacológico , Pautas de la Práctica en Medicina , Adulto , Anciano , Anciano de 80 o más Años , Aminoglicósidos , Antibacterianos/farmacología , Utilización de Medicamentos , Femenino , Bacterias Gramnegativas/efectos de los fármacos , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Pseudomonas aeruginosa/efectos de los fármacos , Estudios Retrospectivos
4.
Ann Thorac Surg ; 68(4): 1376-8; discussion 1378-9, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10543509

RESUMEN

BACKGROUND: Advantages and complications have been reported from the use of chest tubes (CT). To reduce the incidence of complications we have employed a selective use of CT in thoracotomy for congenital cardiovascular procedure; ie, in absence of air leaks and fluid to be drained, no CT was inserted. METHODS: The lung was reexpanded and air evacuated during the chest closure. Early and 6 hours chest roentgenograms were performed on every patient. This study retrospectively reviews the results of this selective approach in 546 patients operated on between 1980 and 1998 mainly for patent ductus arteriosum ligation, pulmonary artery band, aortic coarctation, Blalock-Taussig shunt. Four hundred and eighteen patients did not receive a CT at the initial surgery (group I), and 128 patients received a CT either before or at surgery (group II). RESULTS: 40 patients in group I developed an air or fluid collection large enough to require a CT. Only one patient had complication, from an undetected hemothorax. Nine patients in group II required another CT, and one patient developed a pneumothorax upon pulling out the CT. No death in either group was related to the use or lack of use of the CT. A total of 378 CTs and collecting chambers were saved. CONCLUSIONS: A selective approach to the use of CT in thoracotomies for cardiovascular procedures can be employed with minimal complications, more comfort for the patient, and cost savings.


Asunto(s)
Tubos Torácicos , Cardiopatías Congénitas/cirugía , Complicaciones Intraoperatorias/etiología , Complicaciones Posoperatorias/etiología , Toracotomía/instrumentación , Femenino , Hemotórax/etiología , Hemotórax/prevención & control , Humanos , Recién Nacido , Complicaciones Intraoperatorias/prevención & control , Masculino , Neumotórax/etiología , Neumotórax/prevención & control , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA