Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
2.
Clin Res Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38436739

RESUMEN

BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.

3.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38479833

RESUMEN

OBJECTIVES: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material. METHODS: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit). The conduits were designed according to the Ozaki method. Their hydrodynamic performance (effective orifice area, mean pressure gradient and leakage volume) were evaluated in a mock circulation loop at different hydrodynamic conditions. RESULTS: Hydrodynamic assessment showed significantly larger effective orifice area of PEPE and PEPR compared to PRPR under all conditions and there were no significant differences between PEPE and PEPR [for condition 2: PEPE 2.43 (2.35-2.54) cm2, PEPR: 2.42 (2.4-2.5) cm2, PRPR: 2.08 (1.97-2.21) cm2, adjusted pairwise comparisons: PEPE versus PEPR: P = 0.80, PEPE versus PRPR: P < 0.001, PEPR versus PRPR: P < 0.001]. Mean pressure gradient was significantly lower for PEPE and PEPR compared with PRPR, whereas no significant differences were seen between PEPE and PEPR. Leakage volume was significantly lower for PEPE and PEPR compared with PRPR under all conditions while leakage was similar between PEPE and PEPR. CONCLUSIONS: Pulmonary graft reconstruction with pericardium cusps showed superior hydrodynamic performance compared with polytetrafluoroethylene cusps. Our results suggest that it could be considered as an alternative substitute for right ventricular outflow tract replacement during the Ross procedure.


Asunto(s)
Prótesis Valvulares Cardíacas , Obstrucción del Flujo Ventricular Externo , Humanos , Tereftalatos Polietilenos , Prótesis Vascular , Diseño de Prótesis , Obstrucción del Flujo Ventricular Externo/cirugía , Politetrafluoroetileno , Resultado del Tratamiento , Estudios Retrospectivos
5.
J Heart Lung Transplant ; 43(2): 189-203, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069920

RESUMEN

In recent years, there have been significant advancements in the understanding, risk-stratification, and treatment of cardiogenic shock (CS). Despite improved pharmacologic and device-based therapies for CS, short-term mortality remains as high as 50%. Most recent efforts in research have focused on CS related to acute myocardial infarction, even though heart failure related CS (HF-CS) accounts for >50% of CS cases. There is a paucity of high-quality evidence to support standardized clinical practices in approach to HF-CS. In addition, there is an unmet need to identify disease-specific diagnostic and risk-stratification strategies upon admission, which might ultimately guide the choice of therapies, and thereby improve outcomes and optimize resource allocation. The heterogeneity in defining CS, patient phenotypes, treatment goals and therapies has resulted in difficulty comparing published reports and standardized treatment algorithms. An International Society for Heart and Lung Transplantation (ISHLT) consensus conference was organized to better define, diagnose, and manage HF-CS. There were 54 participants (advanced heart failure and interventional cardiologists, cardiothoracic surgeons, critical care cardiologists, intensivists, pharmacists, and allied health professionals), with vast clinical and published experience in CS, representing 42 centers worldwide. State-of-the-art HF-CS presentations occurred with subsequent breakout sessions planned in an attempt to reach consensus on various issues, including but not limited to models of CS care delivery, patient presentations in HF-CS, and strategies in HF-CS management. This consensus report summarizes the contemporary literature review on HF-CS presented in the first half of the conference (part 1), while the accompanying document (part 2) covers the breakout sessions where the previously agreed upon clinical issues were discussed with an aim to get to a consensus.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Humanos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
6.
J Heart Lung Transplant ; 43(2): 204-216, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069919

RESUMEN

The last decade has brought tremendous interest in the problem of cardiogenic shock. However, the mortality rate of this syndrome approaches 50%, and other than prompt myocardial revascularization, there have been no treatments proven to improve the survival of these patients. The bulk of studies have been in patients with acute myocardial infarction, and there is little evidence to guide the clinician in those patients with heart failure cardiogenic shock (HF-CS). An International Society for Heart and Lung Transplant consensus conference was organized to better define, diagnose, and manage HF-CS. There were 54 participants (advanced heart failure and interventional cardiologists, cardiothoracic surgeons, critical care cardiologists, intensivists, pharmacists, and allied health professionals) with vast clinical and published experience in CS, representing 42 centers worldwide. This consensus report summarizes the results of a premeeting survey answered by participants and the breakout sessions where predefined clinical issues were discussed to achieve consensus in the absence of robust data. Key issues discussed include systems for CS management, including the "hub-and-spoke" model vs a tier-based network, minimum levels of data to communicate when considering transfer, disciplines that should be involved in a "shock team," goals for mechanical circulatory support device selection, and optimal flow on such devices. Overall, the document provides expert consensus on some important issues facing practitioners managing HF-CS. It is hoped that this will clarify areas where consensus has been reached and stimulate future research and registries to provide insight regarding other crucial knowledge gaps.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Choque Cardiogénico/diagnóstico , Insuficiencia Cardíaca/cirugía , Infarto del Miocardio/terapia
8.
Clin Res Cardiol ; 113(1): 75-85, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37462856

RESUMEN

BACKGROUND: Various second-generation transcatheter heart valve (THV) prostheses with high clinical efficacy and safety are available, but there is limited large-scale data available comparing their hemodynamic performance and clinical implications. OBJECTIVE: To compare the hemodynamic performance and short-term clinical outcome of four second-generation THV prostheses. METHODS: 24,124 patients out of the German Aortic Valve Registry who underwent transfemoral transcatheter aortic valve implantation (TAVI) (Evolut™ R n = 7028, Acurate neo™ n = 2922, Portico n = 878 and Sapien 3 n = 13,296) were included in this analysis. Propensity-score weighted analysis was performed to control for differences in age, left ventricular function, STS score and sex. Primary endpoint was survival at one-year, secondary endpoints were 30 days survival, pre-discharge transvalvular gradients, paravalvular leakage and peri-procedural complications. RESULTS: Thirty-day and one-year survival were not significantly different between the four patient groups. Transvalvular gradients in Evolut™ R and Acurate neo™ were significantly lower as compared to Portico and Sapien 3 at hospital discharge. This difference exists across all annulus sizes. Paravalvular leakage ≥ II occurred significantly less often in the Sapien 3 group (1.2%, p < 0.0001). Rate of severe procedural complications was low and comparable in all groups. Permanent pacemaker implantation rate at one year was lowest in the ACUARATE neo group (13.0%) and highest in the Evolut™ R group (21.9%). CONCLUSION: Albeit comparable short-term clinical outcomes there are certain differences regarding hemodynamic performance and permanent pacemaker implantation rate between currently available THV prostheses which should be considered for individual prosthesis selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros
9.
Ann Thorac Surg ; 117(3): 517-525, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37625612

RESUMEN

BACKGROUND: Aortic valve (AV) repair is an evolving surgical strategy in the treatment of nonelderly adults with aortic regurgitation. We aimed to determine the 1-year outcome after AV repair vs surgical AV replacement (sAVR) using real-world data from the German Aortic Valve Registry. METHODS: A total of 8076 aortic regurgitation patients (mean age, 59.1 ± 15.0 years; 76% men; mean The Society of Thoracic Surgeons score, 1.3 ± 1.1), who underwent AV surgical procedures between 2011 and 2015, were identified from German Aortic Valve Registry. The AV was repaired in 2327 patients (29%), and the remaining 5749 patients (71%) underwent sAVR. A weighted propensity score model, including the variables of age, sex, and The Society of Thoracic Surgeons score, was used to correct for baseline differences between AV repair and sAVR cohorts. The primary end point was 1-year survival after AV repair vs sAVR. Secondary end points were freedom from cardiac events and AV reinterventions. RESULTS: Survival at 1 year was 97.7% (95% CI, 97.0%-98.5%) in the AV repair cohort vs 96.4% (95% CI, 95.9%-96.9%) in the propensity score-weighted sAVR cohort (log-rank P < .001). Cox regression revealed a significant advantage of AV repair vs sAVR (hazard ratio, 0.68; 95% CI, 0.51-0.90; P < .0001) on 1-year survival, which was independent of age. Cardiac event-free survival at 1 year was 85.7% (95% CI, 483.8%-87.7%) in the AV repair group vs 81.7% (95% CI, 80.7%-82.9%) in the sAVR group (log-rank P < .001). AV reintervention was required in 38 AV repair patients (1.6%) compared with 1.6% in the sAVR cohort (P = .59). CONCLUSIONS: AV repair surgery, whenever intraoperatively feasible, is associated with a significantly better 1-year survival and 1-year cardiac event-free survival compared with sAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Sistema de Registros
10.
Eur J Cardiothorac Surg ; 64(4)2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37773993

RESUMEN

OBJECTIVES: Transcatheter heart valves (THVs) are investigated according to International Organization for Standardization requirements using in vitro heart simulators to evaluate hydrodynamic performance. In contrast to surgical valves, a THV's performance heavily depends on the configuration and shape of the aortic anulus. In International Organization for Standardization regulations, there is no detailed definition for the construction of a compartment in which a THV has to be tested. Therefore, the aim of this in vitro study was to compare different in vitro models for functional testing of THVs. METHODS: Porcine aortic conduits (23-mm diameter) were implanted in Dacron prostheses and calcified with double-distilled water and calcification buffer at 37°C over 83 million cycles in a Hi-Cycler (durability testing) mimicking nearly 3 patient-years. Hydrodynamic testing of Evolut PRO 26 mm was performed within 3 models (plexiglass, native conduit and calcified conduit; all 23-mm diameter) at a frequency of 64 bpm and different stroke volumes (55-105 ml). RESULTS: Calcified conduits showed significantly higher mean pressure gradients (MPG) and lower effective orifice areas (EOA) in comparison to native conduits (without THV; P < 0.001). EOA and MPG of Evolut PRO differed depending on the model tested. Calcified conduits resulted in the lowest EOA and highest MPG of the THV compared to plexiglass and the native conduit. Full expansion of the THV was least impaired in the native conduit, while lowest geometric orifice area, lowest minimal internal diameter and highest pin-wheeling index of Evolut PRO were seen in the calcified conduit. CONCLUSIONS: Full expansion and functional performance of the Evolut PRO THV depends on the configuration of the testing compartment in an in vitro setting.

11.
Sci Rep ; 13(1): 15340, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37714924

RESUMEN

Pressure recovery (PR) is essential part of the post stenotic fluid mechanics and depends on the ratio of EOA/AA, the effective aortic valve orifice area (EOA) and aortic cross-sectional area (AA). In patients with advanced ascending aortic aneurysm and mildly diseased aortic valves, the effect of AA on pressure recovery and corresponding functional aortic valve opening area (ELCO) was evaluated before and after valve-sparing surgery (Dacron graft implantation). 66 Patients with ascending aortic aneurysm (mean aortic diameter 57 +/- 10 mm) and aortic valve-sparing surgery (32 reimplantation technique (David), 34 remodeling technique (Yacoub)) were routinely investigated by Doppler echocardiography. Dacron graft with a diameter between 26 and 34 mm were implanted. EOA was significantly declined after surgery (3.4 +/- 0.8 vs. 2.6 +/- 0.9cm2; p < 0.001). Insertion of Dacron prosthesis resulted in a significant reduction of AA (26.7 +/- 10.2 vs. 6.8 +/- 1.1cm2; p < 0.001) with increased ratio of EOA/AA (0.14 +/- 0.05 vs. 0.40 +/- 0.1; p < 0.001) and pressure recovery index (PRI; 0.24 +/- 0.08 vs. 0.44 +/- 0.06; p < 0.0001). Despite reduction of EOA, ELCO (= EOA corrected for PR) increased from 4.0 +/- 1.1 to 5.0 +/- 3.1cm2 (p < 0.01) with reduction in transvalvular LV stroke work (1005 +/- 814 to 351 +/- 407 mmHg × ml, p < 0.001) after surgery. These effects were significantly better in patients with Yacoub technique than with the David operation. The hemodynamic findings demonstrate a valve-vessel interaction almost entirely caused by a marked reduction in the ascending AA with significant PR gain. The greater hemodynamic benefit of the Yacoub technique due to higher EOA values compared to the David technique was evident and may be of clinical relevance.


Asunto(s)
Aorta Torácica , Válvula Aórtica , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Tereftalatos Polietilenos , Catéteres , Aorta/diagnóstico por imagen , Aorta/cirugía
12.
Open Heart ; 10(2)2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37696617

RESUMEN

INTRODUCTION: Drug therapy to reduce the regurgitation fraction (RF) of high-grade aortic regurgitation (AR) by increasing heart rate (HR) is generally recommended. However, chronic HR reduction in HFREF patients can significantly improve aortic compliance and thereby potentially decrease RF. To clarify these contrasts, we examined the influence of HR, aortic compliance and stroke volume (SV) on RF in an ex vivo porcine model of severe AR. METHODS: Experiments were performed on porcine ascending aorta with aortic valves (n=12). Compliance was varied by inserting a Dacron graft close to the aortic valve. Both tube systems were connected to a left heart simulator varying HR and SV. AR was accomplished by punching a 0.3 cm2 hole in one aortic cusp. Flow, RF, SV and aortic pressure were measured, aortic compliance with transoesophageal ultrasound probes. RESULTS: Compliance of the aorta was significantly reduced after Dacron graft insertion (0.55%±0.21%/mm Hg vs 0.01%±0.007%/mm Hg, p<0.001, respectively). With increasing HR, RF was significantly reduced in each steady state of the native aorta (HR 40 bpm: 88%±7% vs HR 120 bpm: 42%±10%; p<0.001), but Dacron tube did not affect RF (HR 40 bpm: 87%±8%; p=0.79; HR 120 bpm: 42%±3%; p=0.86). Increasing SV also reduced RF independent of the stiff Dacron graft. CONCLUSION: Aortic compliance did not affect AR in the ex vivo porcine model of AR. RF was significantly reduced with increasing HR and SV. These results affirm that HR lowering and negative inotropic drugs should be avoided to treat severe AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Insuficiencia Cardíaca , Humanos , Porcinos , Animales , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Frecuencia Cardíaca , Volumen Sistólico , Tereftalatos Polietilenos , Aorta/diagnóstico por imagen , Aorta/cirugía
13.
Echocardiography ; 40(10): 1058-1067, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37638407

RESUMEN

BACKGROUND: The importance of pulmonary artery pressure recovery (PR) in patients with Ross procedures in whom a homograft substitutes the resected pulmonary valve, is unknown. The aim of the study was to evaluate the occurrence and extent of PR in the pulmonary artery in 65 asymptomatic patients with pulmonary homograft after Ross surgery during rest and exercise. METHODS: Stress echocardiography was performed in 65 pulmonary homograft patients and 31 controls with native pulmonary valves up to 75 W. Right ventricular systolic pressure (RVSP), transvalvular flow, mean pressure gradient (Pmean ), valve resistance, and RV stroke work were determined in the exercise (max. 75 W) and recovery phases in increments of 25 W each. RESULTS: Pulmonary homografts demonstrated significantly elevated Pmean compared to controls at all stages. When considering pressure recovery (absolute and relative PR at rest 3.8 ± 1.8 mm Hg, 42.6 ± 7.2%, respectively) and transvalvular energy loss (EL; at rest 4.5 ± 4.3 mm Hg) the homograft hemodynamics reached the level of controls. In a subgroup of patients with tricuspid regurgitation, resting RVSP was the same in homograft patients and controls (21.3 ± 6.1 vs. 20.4 ± 6.3, p = .62), despite significant different Pmax values. CONCLUSIONS: Ross patients with pulmonary homograft showed systematically increased hemodynamic parameters compared to normal pulmonary valves. These differences were abolished when PR was considered for homograft patients. The equality of RVSP values at rest in both groups shows non-invasive evidence for PR in the pulmonary system after homograft implantation. Therefore, PR appears to be an important measure in calculating the actual hemodynamics in pulmonary homografts.

14.
Heart ; 109(22): 1706-1713, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37407220

RESUMEN

OBJECTIVE: After transcatheter aortic valve implantation (TAVI), the optimal regimen of anticoagulant therapy in patients with an additional indication for oral anticoagulation remains a matter of debate. This study investigates the efficacy of direct oral anticoagulants (DOACs) versus vitamin K antagonists (VKAs) in patients after TAVI in a real-world population. METHODS: The German Aortic Valve RegistrY (GARY) is a prospective, multicentre registry enrolling patients undergoing invasive treatment for aortic valve disease. From January 2011 to December 2019, 1 41 790 patients from 92 hospitals in Germany were enrolled. Anticoagulatory treatment regimens were assessed at hospital discharge for patients after TAVI procedures. All-cause mortality and the combined endpoint 'cardiac and cerebrovascular events' containing myocardial infarction, stroke, transient ischaemic attack, aortic prosthesis reintervention and all-cause mortality in the first year after TAVI were examined by treatment regimen. RESULTS: Of 45 598 patients (mean age 80.7±5.7 years, 49.3% males) undergoing TAVI, 16 974 patients (37.2%) received an anticoagulant regimen that included VKA or DOAC. Hereof, the majority of patients were prescribed VKA (n=11 333, 66.8%) compared with DOAC (n=5641, 33.2%) with an increase of DOAC use from 9.4% in 2011 to 69.9% in 2019. During the 1-year follow-up, the absolute event rates per 100 person-years for all-cause mortality and the combined endpoint cardiac and cerebrovascular events were 1.9 and 1.3 for VKA-treated and 1.7 and 1.2 for DOAC-treated patients, respectively. After adjustment for baseline confounders, all-cause mortality (HR 0.95, 95% CI 0.88 to 1.01, p=0.114) and cardiac and cerebrovascular event-free survival (HR 0.93, 95% CI 0.86 to 1.01, p=0.071) did not differ significantly between VKA and DOAC groups. CONCLUSIONS: This study supports evidence of the efficacy of DOAC use after TAVI in patients with an indication for oral anticoagulation.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Anticoagulantes/efectos adversos , Válvula Aórtica/cirugía , Fibrinolíticos , Vitamina K , Resultado del Tratamiento , Factores de Riesgo
15.
Eur Heart J Digit Health ; 4(3): 225-235, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37265865

RESUMEN

Aims: Identification of high-risk patients and individualized decision support based on objective criteria for rapid discharge after transcatheter aortic valve implantation (TAVI) are key requirements in the context of contemporary TAVI treatment. This study aimed to predict 30-day mortality following TAVI based on machine learning (ML) using data from the German Aortic Valve Registry. Methods and results: Mortality risk was determined using a random forest ML model that was condensed in the newly developed TAVI Risk Machine (TRIM) scores, designed to represent clinically meaningful risk modelling before (TRIMpre) and in particular after (TRIMpost) TAVI. Algorithm was trained and cross-validated on data of 22 283 patients (729 died within 30 days post-TAVI) and generalisation was examined on data of 5864 patients (146 died). TRIMpost demonstrated significantly better performance than traditional scores [C-statistics value, 0.79; 95% confidence interval (CI)] [0.74; 0.83] compared to Society of Thoracic Surgeons (STS) with C-statistics value 0.69; 95%-CI [0.65; 0.74]). An abridged (aTRIMpost) score comprising 25 features (calculated using a web interface) exhibited significantly higher performance than traditional scores (C-statistics value, 0.74; 95%-CI [0.70; 0.78]). Validation on external data of 6693 patients (205 died within 30 days post-TAVI) of the Swiss TAVI Registry confirmed significantly better performance for the TRIMpost (C-statistics value 0.75, 95%-CI [0.72; 0.79]) compared to STS (C-statistics value 0.67, CI [0.63; 0.70]). Conclusion: TRIM scores demonstrate good performance for risk estimation before and after TAVI. Together with clinical judgement, they may support standardised and objective decision-making before and after TAVI.

16.
Radiat Oncol ; 18(1): 88, 2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37217934

RESUMEN

BACKGROUND: In stereotactic radiotherapy, dose is prescribed to an isodose surrounding the planning target volume (PTV). However, the desired dose inhomogeneity inside the PTV leaves the specific dose distribution to the gross tumor volume (GTV) unspecified. A simultaneously integrated boost (SIB) to the GTV could solve this shortcoming. In a retrospective planning study with 20 unresected brain metastases, a SIB approach was tested against the classical prescription. METHODS: For all metastases, the GTV was isotropically enlarged by 3 mm to a PTV. Two plans were generated, one according to the classical 80% concept with 5 times 7 Gy prescribed (on D2%) to the 80% PTV surrounding isodose (with D98%(PTV) ≥ 35 Gy), and the other one following a SIB concept with 5 times 8.5 Gy average GTV dose and with D98%(PTV) ≥ 35 Gy as additional requirement. Plan pairs were compared in terms of homogeneity inside GTV, high dose in PTV rim around GTV, and dose conformity and gradients around PTV using Wilcoxon matched pairs signed rank test. RESULTS: The SIB concept was superior to the classical 80% concept concerning dose homogeneity inside GTV: Heterogeneity index of GTV was in the SIB concept (median 0.0513, range 0.0397-0.0757) significantly (p = 0.001) lower than in the 80% concept (median 0.0894, range 0.0447-0.1872). Dose gradients around PTV were not inferior. The other examined measures were comparable. CONCLUSION: Our stereotactic SIB concept better defines the dose distribution inside PTV and can be considered for clinical use.


Asunto(s)
Neoplasias Encefálicas , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Estudios de Factibilidad , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario
18.
Cardiovasc Res ; 119(3): 857-866, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35727948

RESUMEN

AIMS: The present study aims to characterize the genetic risk architecture of bicuspid aortic valve (BAV) disease, the most common congenital heart defect. METHODS AND RESULTS: We carried out a genome-wide association study (GWAS) including 2236 BAV patients and 11 604 controls. This led to the identification of a new risk locus for BAV on chromosome 3q29. The single nucleotide polymorphism rs2550262 was genome-wide significant BAV associated (P = 3.49 × 10-08) and was replicated in an independent case-control sample. The risk locus encodes a deleterious missense variant in MUC4 (p.Ala4821Ser), a gene that is involved in epithelial-to-mesenchymal transformation. Mechanistical studies in zebrafish revealed that loss of Muc4 led to a delay in cardiac valvular development suggesting that loss of MUC4 may also play a role in aortic valve malformation. The GWAS also confirmed previously reported BAV risk loci at PALMD (P = 3.97 × 10-16), GATA4 (P = 1.61 × 10-09), and TEX41 (P = 7.68 × 10-04). In addition, the genetic BAV architecture was examined beyond the single-marker level revealing that a substantial fraction of BAV heritability is polygenic and ∼20% of the observed heritability can be explained by our GWAS data. Furthermore, we used the largest human single-cell atlas for foetal gene expression and show that the transcriptome profile in endothelial cells is a major source contributing to BAV pathology. CONCLUSION: Our study provides a deeper understanding of the genetic risk architecture of BAV formation on the single marker and polygenic level.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Animales , Humanos , Enfermedad de la Válvula Aórtica Bicúspide/metabolismo , Enfermedad de la Válvula Aórtica Bicúspide/patología , Válvula Aórtica/patología , Enfermedades de las Válvulas Cardíacas/patología , Estudio de Asociación del Genoma Completo , Pez Cebra/genética , Células Endoteliales/metabolismo
19.
Zentralbl Chir ; 148(3): 284-292, 2023 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-36167311

RESUMEN

In recent years, the use of mechanical support for patients with cardiac or circulatory failure has continuously increased, leading to 3,000 ECLS/ECMO (extracorporeal life support/extracorporeal membrane oxygenation) implantations annually in Germany. Due to the lack of guidelines, there is an urgent need for evidence-based recommendations addressing the central aspects of ECLS/ECMO therapy. In July 2015, the generation of a guideline level S3 according to the standards of the Association of the Scientific Medical Societies in Germany (AWMF) was announced by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS). In a well-structured consensus process, involving experts from Germany, Austria and Switzerland, delegated by 16 scientific societies and the patients' representation, the guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" was created under guidance of the GSTCVS, and published in February 2021. The guideline focuses on clinical aspects of initiation, continuation, weaning and aftercare, herein also addressing structural and economic issues. This article presents an overview on the methodology as well as the final recommendations.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque , Humanos , Sociedades Científicas , Circulación Extracorporea , Sociedades Médicas , Alemania
20.
Physiol Rep ; 10(23): e15432, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36511522

RESUMEN

Relevant pressure recovery (PR) has been shown to increase functional stenotic aortic valve orifice area and reduce left ventricular load. However, little is known about the relevance of PR in the pulmonary artery. The study examined the impact of PR using 2D-echocardiography in the pulmonary artery distal to the degenerated homograft in patients after Ross surgery. Ninety-two patients with pulmonary homograft were investigated by Doppler echocardiography (mean time interval after surgery 31 ± 26 months). PR was measured as a function of pulmonary artery diameter determined by computed tomography angiography. Homograft orifice area, valve resistance, and transvalvular stroke work were calculated with and without considering PR. PR decreased as the pulmonary artery diameter increased (r = -0.69, p < 0.001). Mean PR was 41.5 ± 7.1% of the Doppler-derived pressure gradient (Pmax ), which resulted in a markedly increased homograft orifice area (energy loss coefficient index [ELCOI] vs. effective orifice area index [EOAI], 1.3 ± 0.4 cm2 /m2 vs. 0.9 ± 0.4 cm2 /m2 , p < 0.001). PR significantly reduced homograft resistance and transvalvular stroke work (822 ± 433 vs. 349 ± 220 mmHg × ml, p < 0.0001). When PR was considered, the correlations of the parameters used were significantly better, and 11 of 18 patients (61%) in the group with severe homograft stenosis (EOAI <0.6 cm2 /m2 ) could be reclassified as moderate stenosis. Our results showed that the Doppler measurements overestimated the degree of homograft stenosis and thus the right ventricular load, when PR was neglected in the pulmonary artery. Therefore, Doppler measurements that ignore PR can misclassify homograft stenosis and may lead to premature surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Humanos , Constricción Patológica , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...