Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMJ Case Rep ; 16(5)2023 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-37247947

RESUMEN

A man in his 60s with no relevant previous medical history presented to an urban, major trauma centre by ambulance after being found with a head injury in a nightclub. The paramedics reported he was hypoxic, hypotensive and tachycardic with altered mental status. At the emergency department, he had oxygen saturations of 85% despite high-flow oxygen and was hypotensive at 88/43mmHg. We were concerned the patient was haemorrhaging given the lack of response to oxygen therapy and their hypotension. However, an arterial blood gas (ABG) established a diagnosis of methemoglobinaemia. Methylthioninium chloride was promptly administered, and the patient's condition improved. He later reported using recreational drugs, including alkyl nitrites ('poppers'). He was monitored until his fraction of methaemoglobin returned to normal baseline levels with serial ABGs. He was discharged 24 hours later. It was suspected that his use of alkyl nitrites was the most likely cause of methaemoglobinaemia.


Asunto(s)
Metahemoglobinemia , Masculino , Humanos , Metahemoglobinemia/inducido químicamente , Metahemoglobinemia/diagnóstico , Metahemoglobinemia/tratamiento farmacológico , Nitritos , Azul de Metileno/uso terapéutico , Oxígeno
2.
BMJ Case Rep ; 20172017 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-29054892

RESUMEN

A Littre's hernia is an unusual phenomenon where a Meckel's diverticulum protrudes through a potential abdominal opening. We wish to present a unique case of a 79-year-old man with respiratory distress following a fall from standing, initially managed as a haemothorax. After a chest drain was placed, bowel contents were drained from the pleural cavity and he was taken to theatre. He had a history of minimally invasive oesophagectomy for cancer and had subsequently developed a diaphragmatic hernia. A blind ending diverticulum with a perforation at its tip was found in the left oblique lung fissure that was subsequently confirmed histologically as a perforated Meckel's diverticulum. The patient had a prolonged stay on the intensive care unit with a left-sided empyema that was managed radiologically prior to discharge. Unfortunately 4 months postoperatively, he passed away from hospital-acquired pneumonia on a rehabilitation ward.


Asunto(s)
Accidentes por Caídas , Hernia Diafragmática Traumática/diagnóstico por imagen , Perforación Intestinal/diagnóstico por imagen , Divertículo Ileal/complicaciones , Cavidad Pleural/diagnóstico por imagen , Neumotórax/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Anciano , Tubos Torácicos , Resultado Fatal , Heces , Hernia Diafragmática Traumática/patología , Hernia Diafragmática Traumática/cirugía , Humanos , Perforación Intestinal/patología , Perforación Intestinal/cirugía , Masculino , Divertículo Ileal/diagnóstico por imagen , Divertículo Ileal/patología , Cavidad Pleural/lesiones , Cavidad Pleural/patología , Neumonía Asociada al Ventilador , Neumotórax/etiología , Neumotórax/cirugía , Radiografía , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/cirugía
3.
J Orthop Res ; 35(4): 820-828, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27306746

RESUMEN

We have developed a laser-textured superhydrophilic Ti-6Al-4V surface with unique surface chemistry and topography that substantially promotes osteoblast adhesion in culture. Here we investigate the osteointegration of laser-textured implants in an ovine model. Our hypothesis was that laser-textured implants, without any surface coating (LT), would encourage comparable amounts of bone-implant contact and interfacial strength when compared with widely accepted hydroxyapatite (HA) coated implants. Additionally, we hypothesized that LT would significantly increase bony integration compared with machine-finished (MF) and grit-blasted (GB) implants. Forty-eight tapered transcortical pins were implanted into six sheep. Four experimental groups (LT, HA, MF, and GB) were investigated (n = 12) and implants remained in vivo for 6 weeks. Bone apposition rates, interfacial shear strength, and bone-implant contact (BIC) were quantified. The interfacial strength of LT and HA implants were found to be significantly greater than GB (p = 0.032 and p = 0.004) and MF (p = 0.004 and p = 0.004, respectively), but no significant difference between LT and HA implants was observed. Significantly increased BIC was measured adjacent to HA implants when compared with both LT and GB implant surfaces (p = 0.022 and p = 0.006, respectively). No significant difference was found when LT and GB implants were compared. However, all surface finishes encouraged significantly increased BIC when compared with the MF surface. Maximizing implant fixation to host bone is vital for its long-term success. The production of an LT surface is a simple and cheap manufacturing process and this study demonstrated that laser-textured implants are a very promising technical development that warrants further research. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:820-828, 2017.


Asunto(s)
Rayos Láser , Oseointegración/efectos de los fármacos , Oseointegración/fisiología , Prótesis e Implantes , Titanio/química , Aleaciones , Animales , Fenómenos Biomecánicos , Regeneración Ósea , Huesos/metabolismo , Interfase Hueso-Implante , Materiales Biocompatibles Revestidos , Durapatita/química , Femenino , Humanos , Microscopía Electrónica de Rastreo , Diseño de Prótesis , Dispersión de Radiación , Resistencia al Corte , Ovinos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...