Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Talanta ; 270: 125562, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38159354

RESUMEN

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. Using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

2.
J Hazard Mater ; 459: 132165, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37531768

RESUMEN

Mechanism of hexavalent chromium removal (Cr(VI) as CrO42-) by the weak-base ion exchange (IX) resin ResinTech® SIR-700-HP (SIR-700) from simulated groundwater is assessed in the presence of radioactive contaminants iodine-129 (as IO3-), uranium (U as uranyl UO22+), and technetium-99 (as TcO4-), and common environmental anions sulfate (SO42-) and chloride (Cl-). Batch tests using the acid sulfate form of SIR-700 demonstrated Cr(VI) and U(VI) removal exceeded 97%, except in the presence of high SO42- concentrations (536 mg/L) where Cr(VI) and U(VI) removal decreased to ≥ 80%. However, Cr(VI) removal notably improved with co-mingled U(VI) that complexes with SO42- at the protonated amine sites. These U-SO42- complexes are integral to U(VI) removal, as confirmed by the decrease in U(VI) removal (<40%) when the acid chloride form of SIR-700 was used instead. Solid phase characterization revealed that CrO42- is removed by IX with SO42- complexes and/or reduced to amorphous Cr(III)(OH)3 at secondary alcohol sites. Tc(VII)O4- and I(V)O3- also undergo chemical reduction, following a similar removal mechanism. Oxyanion removal preference is determined by the anion reduction potential (CrO42->TcO4->IO3-), geometry, and charge density. For these reasons, 39% and 69% of TcO4- and 17% and 39% of IO3- are removed in the presence and absence of Cr(VI), respectively.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...