Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Arthrosc Tech ; 13(2): 102872, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38435265

RESUMEN

Persistent rotational instability after anterior cruciate ligament reconstruction is a relatively common postoperative complication, typically associated with graft verticalization due to improper femoral tunnel placement, especially with classic transtibial femoral tunnel techniques. This article describes a technique designed to reorient a verticalized anterior cruciate ligament graft at its femoral insertion to a more anatomic position in the coronal and sagittal planes, aiming to restore knee stability without the need for a complete revision operation. Additionally, a lateral extra-articular tenodesis with fascia lata is added to reinforce rotational stability.

2.
Arthrosc Sports Med Rehabil ; 5(5): 100778, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37560143

RESUMEN

Purpose: The purpose of this study was to evaluate practice patterns of a single surgeon with respect to meniscectomy and meniscal repair over a 20-year period at a single institution. Methods: A cross-sectional descriptive study was carried out by reviewing the surgical data from the past 20 years (2002-2021) of patients who underwent arthroscopic primary meniscal surgery. Age, sex, knee and meniscus affected, morphology of the meniscal tear, meniscal radial location, location on the axial plane, tissue quality, and associated injuries were recorded. An analysis of the evolution of the characteristics of the meniscal lesions was performed according to the presence of degenerative tissue, the repairability of the lesion, and the treatment performed. Categorical data were represented in contingency tables and compared using the χ2 test for significance of differences, which was set at P < .05. Results: In total, 1,892 cases were included. A decrease in degenerative meniscal tears was found, from 63.2 in 2002 to 2006 to 9.7% in 2017 to 2021 (P < .001), while repairable tears increased from 1.6% to 82.3% P < .001); in the same periods, arthroscopic partial meniscectomy procedures declined from 75.7% to 17.7% (P < .001) while meniscal repair increased from 0.4% to 81.3% (P < .001). All types of tears increased significantly their repairability, although longitudinal tears, root tears, and ramp lesions showed the highest possibilities for repair. Conclusions: In the present study, a drastic change in the attitude toward meniscal preservation in the past 20 years was observed, with a large increase in the proportion of tears considered repairable found in primary arthroscopic surgery (to 80% of cases) and a decrease in degenerative meniscus tears (to less than 10%). Clinical Relevance: In the past 2 decades, arthroscopic knee surgery has evolved such that more meniscus tears are deemed repairable, and fewer tears considered degenerative are indicated for arthroscopy.

3.
Int Orthop ; 47(10): 2419-2427, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36944816

RESUMEN

PURPOSE: To compare biomechanical behaviour of the anterior root of the lateral meniscus (ARLM) after a transtibial repair (TTR) and after an in situ repair (ISR), discussing the reasons for the efficacy of the more advantageous technique. METHODS: Eight cadaveric human knees were tested at flexion angles from 0° to 90° in four conditions of their ARLM: intact, detached, reinserted using TTR, and reinserted using ISR. Specimens were subjected to 1000 N of compression, and the contact area (CA), mean pressure (MP), and peak pressure (PP) on the tibial cartilage were computed. For the TTR, traction force on the sutures was registered. RESULTS: ARLM detachment significantly altered contact biomechanics, mainly at shallow flexion. After ISR, differences compared to the healthy group persisted (extension, CA 22% smaller (p = 0.012); at 30°, CA 30% smaller (p = 0.012), MP 21%, and PP 32% higher (both p = 0.017); at 60°, CA 28% smaller (p = 0.012), MP 32%, and PP 49% higher (both p = 0.025). With TTR, alterations significantly decreased compared to the injured group, with no statistical differences from the intact ones observed, except for CA at extension (15% decrease, p = 0.012) and at 30° (12% decrease, p = 0.017). The suture tension after TTR, given as mean(SD), was 36.46(11.75)N, 44.32(11.71)N, 40.38(14.93)N, and 43.18(14.89)N for the four tested flexion angles. CONCLUSIONS: Alterations caused by ARLM detachment were partially restored with both ISR and TTR, with TTR showing better results on recovering CA, MP, and PP in the immediate postoperative period. The tensile force was far below the value reported to cause meniscal cut-out in porcine models.


Asunto(s)
Traumatismos de la Rodilla , Lesiones de Menisco Tibial , Humanos , Porcinos , Animales , Meniscos Tibiales/cirugía , Articulación de la Rodilla/cirugía , Lesiones de Menisco Tibial/cirugía , Traumatismos de la Rodilla/cirugía , Tibia/cirugía , Fenómenos Biomecánicos , Cadáver
4.
Arthrosc Tech ; 11(10): e1769-e1777, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36311320

RESUMEN

Lateral collateral ligament (LC) injuries that go unnoticed when associated with an anterior cruciate ligament (ACL) tear can increase stress forces on the ACL graft causing its failure. Furthermore, it is a main stabilizer to varus stress and external rotation. On the other hand, the reinforcement of anterolateral structures during ACL reconstruction has regained popularity in recent years, because evidence has shown that it increases the control of rotational laxity and decreases ACL graft failures, especially in revision surgery. The present article shows a technique to perform an ACL reconstruction, associated with the reconstruction of the LCL and of the anterolateral ligament using a single Achilles tendon allograft, which is split after the fixation of the ACL graft into two fascicles.

5.
Sci Rep ; 12(1): 6182, 2022 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-35418662

RESUMEN

Treatment of posterior meniscal roots tears evolved after biomechanical evidence of increased pressures on the tibiofemoral cartilage produced by this lesion and the subsequent accelerated development of arthritis or osteonecrosis observed clinically. However, little is known about the consequences of the detachment of the anterior roots. This in-vitro study analyzes the biomechanical changes in the tibiofemoral joint caused by avulsion of the anterior root of the lateral meniscus. The effectiveness of surgical root re-insertion to restore the pre-injured conditions is also evaluated. Using cadaveric knees at flexion angles from 0° to 90°, results show that the lesion significantly reduces the contact area and raises the pressure on the tibiofemoral cartilage of the injured compartment at all angles. Said modifications become larger at low flexion angles, which are the most frequent positions adopted by the knee in daily and sports activities, where they result similar to total meniscectomy. In-situ repair partially restores the contact biomechanics. Consequently, careful attention should be paid to proper diagnosis and treatment of detached anterior roots since the observed altered knee contact might induce similar degenerative problems in the cartilage as with completely detached posterior roots.


Asunto(s)
Enfermedades de los Cartílagos , Traumatismos de la Rodilla , Lesiones de Menisco Tibial , Fenómenos Biomecánicos , Cadáver , Humanos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Rango del Movimiento Articular , Lesiones de Menisco Tibial/cirugía
6.
Arthrosc Tech ; 11(2): e263-e271, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35155122

RESUMEN

Massive irreparable rotator cuff tears (RCT) in younger and active patients remain a significant clinical challenge to orthopaedic surgeons. Superior capsular reconstruction (SCR) has been presented as a way to restore the restraining effect of the superior joint capsule and the balanced force couples necessary for dynamic shoulder function; furthermore, it does not exclude future treatment options. The purpose of this article is to show a technical modification of the SCR in massive and revision RCT using Achilles tendon allograft as an effective static restraint to prevent superior migration of the humeral head due to its thickness and robustness, and performing a side-to-side repair on the greater tuberosity between the graft and the residual infraspinatus tendon to completely restore the superior stability of the shoulder joint.

7.
Arthrosc Tech ; 10(8): e1965-e1971, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34401241

RESUMEN

Massive rotator cuff tears (RCT) have traditionally been a challenging clinical problem for shoulder surgeons. A broad variety of treatment options have been proposed to address this problem, but outcomes have been as variable as the techniques themselves. Superior capsular reconstruction has been presented as a way to restore the restraining effect of the superior joint capsule and balanced force couples in massive tears of the superior rotator cuff. The purpose of this article is to propose a technical modification of the superior capsular reconstruction in large to massive RCT, and, especially in anterior L-shaped RCT, using the long head of the biceps tendon autograft to reinforce the weakest area of the anterior capsule, not as an augmentation of the rotator cuff, but as a static stabilizer of the humeral head, allowing the rotator cuff repair to heal without tension.

8.
J Knee Surg ; 34(3): 267-272, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31434141

RESUMEN

The purpose of this study was to analyze the effect of obesity and other clinical factors on the outcome of meniscal allograft transplantation (MAT) with transosseous fixation. A retrospective cohort study was performed on patients who underwent a MAT between 2002 and 2017. All the participants had a minimum follow-up period of 24 months. The variables assessed were age at the time of the transplant, side, sex, transplanted meniscus (lateral/medial), body mass index (BMI), smoking status, and previous surgeries. Lysholm, Tegner, and International Knee Documentation Committee (IKDC) test outcomes, and patient satisfaction were recorded. Image assessment was performed using plain standing X-rays and a follow-up magnetic resonance imaging scan. Thirty-five patients fulfilled the inclusion criteria. The mean follow-up time was of 75.7 standard deviation (SD) 43.4 months. Patients with a BMI ≥ 30 underwent medial meniscal transplants (88.9 vs. 42.3%, p = 0.022, respectively) more frequently. Obese patients had a significantly lower IKDC (48.6 SD 19.9 vs. 61.7 SD 13.1, p = 0.038, power: 57.5%) and Lysholm (60.3 SD 19.2 vs. 79.4 SD 14.3, p = 0.004, power: 88.7%) scores compared with nonobese patients. The satisfaction and Tegner scores were also lower in obese patients (55.6 vs. 80.7%, p = 0.136, and 2.8 SD 1.0 vs. 4.0 SD 1.9, p = 0.104, respectively); however, these differences were not statistically significant. Obese patients had higher rates of meniscal transplant failure compared with nonobese patients (adjusted hazard ratio: 11.8 [95% confidence interval: 1.5-91.4]). No differences were observed between obese and nonobese patients regarding age, sex, side, smoking status, and follow-up time. In this study, a BMI ≥ 30 kg/m2 resulted in higher MAT failure rates. Nonobese patients had better knee functional results compared with obese individuals.


Asunto(s)
Supervivencia de Injerto , Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/trasplante , Obesidad/complicaciones , Lesiones de Menisco Tibial/cirugía , Adulto , Funcionamiento Retardado del Injerto , Femenino , Estudios de Seguimiento , Humanos , Traumatismos de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética , Masculino , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/patología , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Lesiones de Menisco Tibial/diagnóstico por imagen , Trasplante Homólogo/métodos
9.
Arthrosc Tech ; 9(11): e1657-e1663, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33294323

RESUMEN

A technique for augmentation of the anterior cruciate ligament (ACL) with hamstring graft and lateral extra-articular tenodesis is presented. The patient is positioned supine with the knee flexed 90°. First, intra-articular injuries are addressed arthroscopically, and then autologous hamstring tendons are harvested and measured; the present technique is a resource for cases with a very small graft diameter (less than 8 mm), due to thin tendons or to tendon breakage, even after tripling the hamstring graft, which is prepared using a facia lata strip long enough to fit the lengths of the femoral tunnel, the anterior cruciate ligament graft, and the tibial tunnel. A single femoral tunnel is performed and only 2 interference screws are needed for fixation.

10.
Arthrosc Tech ; 9(6): e747-e754, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32577347

RESUMEN

A technique for anterior cruciate ligament (ACL) reconstruction in patients with open physis is presented. The patient is positioned supine with the knee flexed 90°. After intraarticular injuries are addressed, an autologous hamstring graft is harvested and prepared using a suspension device attached in its expansion device. All-epiphyseal femoral and tibial tunnels of the same diameter of the graft are created; both of them are drilled in an outside-in direction, sparing the physis under radioscopic control. A second divergent tibial tunnel of the same diameter of the graft, distal to the physis, is created in an outside-in, mediolateral, and craniocaudal direction, leaving a 1-cm bone bridge between the 2 tibial tunnels. The graft is passed through the all-epiphyseal tunnels, from femoral to tibial, and pulled until the suspension device leans on the lateral femoral cortex. The graft is passed through the second divergent tibial tunnel and fixed in it with an interference screw to move the pressure away from the physis.

11.
Clin Biomech (Bristol, Avon) ; 76: 105008, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32413774

RESUMEN

BACKGROUND: In ACL repair, full-length single-diameter tunnels facilitate anatomic femoral fixation with suspensory devices, especially with outside-in techniques, and are required after accidental cortical perforation. With tunnel diameters over 6 mm, fixation resistance using regular suspensory devices may not suffice. Oversized cortical footprint devices could be a solution to guarantee fixation performance in larger tunnel diameters. This study aims to assess the biomechanical properties of ACL femoral fixation provided by two enlarged suspensory devices of similar characteristics, a fixed loop (G-Lok™ with G-Lok-XL™) and an adjustable loop (ProCinch™ with G-Lok-XL™), resting on a full-length 9 mm diameter tunnel compared to the widely accepted regular fixed-loop device (G-Lok™) on a socket tunnel. METHODS: Twenty-seven fresh frozen porcine femurs and flexor digitorum profundus tendons were randomly assigned to a study group depending on the fixation method used (N = 9). Graft-femur constructs were subjected to a traction cyclic test (5000 cycles, [50-250]N load, 1 Hz) followed by a load-to-failure test (v = 1 mm/s). Residual displacement during the cyclic test and stiffness, displacements at physiological loads, ultimate load and corresponding displacement during the load-to-failure test were determined. FINDINGS: No significant differences could be established for any parameter measured in the comparison between the control with the socket tunnel and the oversized fixations with full-length tunnels. INTERPRETATION: ACL femoral fixation achieved in full-length single diameter tunnels by using an enlarged suspension device, both with a fixed or an adjustable loop, provide similar biomechanical properties to the gold-standard fixed-loop device in a socket tunnel. Therefore, its clinical use may be safe.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/instrumentación , Fémur , Animales , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Fémur/cirugía , Porcinos , Tendones/cirugía
12.
Arthrosc Tech ; 9(4): e549-e552, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32368477

RESUMEN

Ramp lesions are considered hidden injuries of the medial meniscus and are very difficult to diagnose. The Finochietto jump sign is a very specific finding that could be considered pathognomonic regarding ramp lesions. This sign consists of a sudden jerk that appears when the free edge of the posterior horn of the medial meniscus is dislocated anteriorly due to the medial condyle interposition when an anterior drawer test is performed on a knee with a ramp lesion, especially when it is associated with an anterior cruciate ligament tear. In this technical note, the Finochietto sign is described clinically, is correlated with its exploration under anesthesia, and is described for the first time under arthroscopic examination in the case of a ramp lesion, in which this finding can help to the diagnosis when present, especially when associated with anterior cruciate ligament tears.

13.
Sci Rep ; 10(1): 1748, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-32019982

RESUMEN

The importance of meniscal root integrity to preserve contact load distribution and stability at the knee joint is recognised. Transosseous suture technique is commonly used to repair meniscal root tears. However, clinical results are not completely satisfactory. Specifically, concern exists about the development of substantial displacements at the repaired root. This study aims to assess if the use of a post-insertion tensioning knotless-anchor at the distal exit of the tibial tunnel improves time-zero biomechanical properties of the transtibial repair compared to knotting sutures over a cortical button. Twenty porcine tibia with detached posterior medial meniscal roots were randomized into two groups depending on the method to fix the sutures after root repair: knotless-anchor (KA) or suture-button (SB). Specimens underwent cyclic and load-to-failure testing. Group KA showed significantly smaller residual root displacements after low-level repetitive loads. At the load-to-failure test, Group KA exhibited significantly lower displacements at representative subcritical loads and higher resistance to development of clinically relevant displacements. The authors conclude that use of a knotless suture anchor attached at the distal outlet of the bone tunnel may be an effective solution to reduce root displacements in transtibial meniscal root repairs, a matter reported to alter biomechanics of joint contact.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Menisco/cirugía , Tibia/cirugía , Lesiones de Menisco Tibial/cirugía , Animales , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos de Cirugía Plástica/métodos , Técnicas de Sutura , Suturas , Porcinos
14.
Orthop Traumatol Surg Res ; 105(6): 1115-1118, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31182389

RESUMEN

Anatomical reinsertion is the optimal treatment for meniscal root injuries. However, in chronic settings, tissue fraying of the meniscal root may impede it. This study describes a salvage technical procedure performed in 3 cases of chronic anterior root avulsion of the lateral meniscus with profuse tissue degeneration in which remnant debridement resulted in amputation of the root. Reinsertion of the meniscus at the remaining healthy tissue was performed using an all-inside anchoring technique.


Asunto(s)
Amputación Quirúrgica , Artroscopía/métodos , Meniscos Tibiales/cirugía , Lesiones de Menisco Tibial/cirugía , Adulto , Femenino , Humanos , Traumatismos de la Rodilla/cirugía , Imagen por Resonancia Magnética , Masculino , Meniscos Tibiales/diagnóstico por imagen , Persona de Mediana Edad , Reimplantación , Lesiones de Menisco Tibial/diagnóstico , Lesiones de Menisco Tibial/fisiopatología
15.
Arthroscopy ; 35(3): 857-863, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30704886

RESUMEN

PURPOSE: To analyze, in a long series of patients with knee injuries, the meniscal tear patterns in both stable and unstable knees to ascertain the exact proportion of such injuries that could have been repaired. METHODS: A descriptive cross-sectional study was undertaken by reviewing the clinical reports of arthroscopic knee operations carried out in 1 hospital. A total of 2,066 consecutive patients were included in the study. An analysis of clinical and anatomical data of knee lesions, including the shape of the meniscal tears and the surrounding injuries, was performed. RESULTS: Out of all meniscal tears, 34.9% were found to be repairable, a figure that rose to 55.6% in those tears accompanied by anterior cruciate ligament injuries; 37% of meniscal tears in male patients were repairable, and 28% in their female counterparts; 38.2% of medial meniscal tears were repairable and 30.6% in their lateral counterparts. The most frequently encountered injury was the complex tear (46.9%). CONCLUSIONS: Our study concludes that, according to current standard indications, 34.9% of all meniscal injuries offer the potential for repair. Where the injury is also accompanied by anterior cruciate ligament damage, the proportion of repairable tears rises to 55.6%. This information should increase the interest for meniscal preservation in the future. LEVEL OF EVIDENCE: Level IV, case series.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Lesiones de Menisco Tibial/cirugía , Adolescente , Adulto , Lesiones del Ligamento Cruzado Anterior/cirugía , Artroscopía , Estudios Transversales , Femenino , Humanos , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Masculino , Meniscos Tibiales/cirugía , Persona de Mediana Edad , Rotura/cirugía , Adulto Joven
16.
Arthrosc Tech ; 7(8): e797-e804, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30167356

RESUMEN

A technique for associated anterior cruciate ligament and fibular collateral ligament reconstruction is shown, using a single hamstring tendon graft, which is prepared asymmetrically, leaving one-third of the length with a single diameter and two-thirds with a double diameter. A single femoral tunnel is created, using an interference screw for fixation and isolation of the grafts. A suspension device is used for tibial fixation, allowing for length adjustment according to the graft's length. The objective of this Technical Note is to provide the orthopaedic surgeon with a resource for anterior cruciate ligament and fibular collateral ligament reconstruction even with short grafts, saving bone stock and avoiding the need for allografts.

17.
J Orthop Case Rep ; 8(2): 81-85, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30167421

RESUMEN

INTRODUCTION: Simultaneous avulsion fractures of the insertion of both cruciate ligaments of the knee are extremely uncommon lesions and their treatment remains difficult. The purpose of this paper is to show an arthroscopic repair technique of simultaneous tibial avulsion fracture of both cruciate ligaments of the knee such by using an adjustable length suspension device. CASE REPORT: A 25-year-oldmale patient was treated by arthroscopic reduction and fixation of both bony avulsion of cruciate ligaments of the knee with a sliding and adjustable length suspension device (ZipTight, Biomet, Warsaw, IN, USA). There were no post-operative complications appeared. At 18-month follow-up, the patient was conducting normal life, free of symptoms. At clinical examination, Lachman, anterior drawer, pivot shift, posterior drawer, and reverse pivot shift tests were negative. Range of motion was 130° flexion, presenting a slight 5° of extension deficit. The International Knee Documentation Committee score was 83.80 points. Lysholm scale was 85 points. CONCLUSION: The described repair technique is able to provide stable fixation of bone fragments in the face of early fracture consolidation, as well as minimizing potential complications and surgical time.

18.
Arthrosc Tech ; 7(7): e731-e737, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30094144

RESUMEN

A technique for augmentation of the partial anterior cruciate ligament is presented. The patient is positioned supine with the knee flexed 90°. After addressing intra-articular injuries, the autologous semitendinosus tendon is harvested and measured in a doubled manner; after that, the tibial tunnel is performed in the outside-in direction, of the same diameter of the doubled graft. Both ends of the graft are sutured together, after inserting it through the loop of a suspension device, which is attached in its augmentation piece. A lateral femoral incision is made, to approach the joint through the "over the top" position. A looped thread is introduced inside the joint with the aid of a hook. This thread pulls the graft's sutures through the "over the top" position. A femoral tunnel is then drilled in the lateromedial and caudocranial direction. The suspension device is attached to the anterior tibial cortex and the graft is pulled in the caudocranial direction to the femoral tunnel, where an interference screw is used for fixation.

19.
Int Orthop ; 42(4): 811-818, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29396804

RESUMEN

PURPOSE: To assess the role of suture cutout in the mechanics of failure of the repaired posterior meniscal root during the early post-operative period when using sutures of different shape. METHODS: Twenty medial porcine menisci were randomized in two groups depending on the suture shape used to repair the posterior root: thread or tape. The sutured menisci were subjected to cyclic loading (1000 cycles, (10, 30) N) followed by load-to-failure testing. Residual displacements, stiffness, and ultimate failure load were determined. During tests, the tissue-suture interface was recorded using a high-resolution camera. RESULTS: In cyclic tests, cutout progression at the suture insertion points was not observed for any specimen of either group and no differences in residual displacements were found between use of thread or tape. In load-to-failure tests, suture cutout started in all menisci at a load close to the ultimate failure and all specimens failed by suture pullout. Suture tape had a greater ultimate load with no other differences. CONCLUSIONS: In a porcine model of a repaired posterior meniscal root subjected to cyclic loads representative of current rehabilitation protocols in the early post-operative period under restricted loading conditions, suture cutout was not found as a main source of permanent root displacement when using suture thread or tape. Suture cutout progression started at high loading levels close to the ultimate load of the construct. Tape, with a meniscus-suture contact area larger than thread, produced higher ultimate load.


Asunto(s)
Meniscos Tibiales/cirugía , Procedimientos Ortopédicos/efectos adversos , Técnicas de Sutura/efectos adversos , Lesiones de Menisco Tibial/cirugía , Animales , Fenómenos Biomecánicos/fisiología , Humanos , Técnicas In Vitro , Procedimientos Ortopédicos/métodos , Periodo Posoperatorio , Suturas/efectos adversos , Porcinos , Resistencia a la Tracción
20.
Arthrosc Tech ; 6(3): e621-e626, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28706808

RESUMEN

A technique for posterior meniscal root reinsertion is presented. With the arthroscope in the central transtendinous portal for a better view, a 5-mm transtibial tunnel is created with the aid of an anterior cruciate ligament guide open to 45°. A suture device, which consists of a long needle with an eyelet on its tip, is introduced through the tunnel with a suture thread inserted through the eyelet, while the meniscus is stabilized with a grasper inserted through the anterior portal. The meniscus is pierced with the device, and the suture thread is recovered with said grasper. A finger-tip pincer is inserted through the tunnel to recover the thread. The same procedure is followed to perform a second stitch. A lasso loop is made for both stitches, and the resultant tails are knotted to a knotless suture anchor, which is inserted in the anterior cortex of the tibia, 1 cm distal to the extra-articular end of the tibial tunnel.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...