Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ACS Meas Sci Au ; 4(1): 25-41, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38404496

RESUMEN

This article provides an overview of the work reported in the past decade in the field of microfluidic fuel cells. To develop appropriate research, the most commonly used electrocatalytic materials were considered and a new classification was proposed based on their nature: abiotic, hybrid, or biological. This classification allowed the authors to discern the information collected. In this sense, the types of electrocatalysts used for the oxidation of the most common fuels in different environments, such as glucose, ethanol, methanol, glycerol, and lactate, were presented. There are several phenomena presented in this article. This information gives an overview of where research is heading in the field of materials for electrocatalysis, regardless of the fuel used in the microfluidic fuel cell: the synthesis of abiotic and biological materials to obtain hybrid materials that allow the use of the best properties of each material.

2.
Bioelectrochemistry ; 146: 108147, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35504230

RESUMEN

Ferrocene-based polymers as redox mediators are considered versatile and important in the study of glucose biosensors. Poly-L-lysine (PLL), as a cationic polymer, possesses good properties including biocompatibility, biodegradation and water solubility. In this work, PLL was modified with ferrocene carboxylate in a very simple way by activating the carboxyl group of Fc, which reacted with the amino groups of the polymer. The resulting product was analysed by FTIR. Performance as a redox mediator (Fc-PLL) with the enzyme glucose oxidase was tested by cyclic voltammetry and showed an increase in the oxidation current in the presence of glucose in PBS pH 7.4. Additionally, performance as a biosensor was evaluated by amperometry and gave a linear range of 0-10 mM, a limit of detection of 23 µM, a sensitivity of 6.55 µA/cm2 mM and high selectivity. To evaluate the charged regions of Fc-PLL/GOx on the electrode surface, analysis by scanning electrochemical microscopy showed remarkable activity. The Fc-PLL redox polymer as a glucose biosensor has been well accepted as this kind of material, and the results showed remarkable activity as an electron transfer mediator between the redox polymer and the GOx enzyme.


Asunto(s)
Técnicas Biosensibles , Glucosa , Técnicas Biosensibles/métodos , Electrodos , Enzimas Inmovilizadas/química , Glucosa/análisis , Glucosa Oxidasa/química , Metalocenos , Oxidación-Reducción , Polilisina/metabolismo , Polímeros/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...