1.
Ear Hear ; 44(5): 1014-1028, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36790447

RESUMEN

OBJECTIVE: Minimally traumatic surgical techniques and advances in cochlear implant (CI) electrode array designs have allowed acoustic hearing present in a CI candidate prior to surgery to be preserved postoperatively. As a result, these patients benefit from combined electric-acoustic stimulation (EAS) postoperatively. However, 30% to 40% of EAS CI users experience a partial loss of hearing up to 30 dB after surgery. This additional hearing loss is generally not severe enough to preclude use of acoustic amplification; however, it can still impact EAS benefits. The use of electrocochleography (ECoG) measures of peripheral hair cell and neural auditory function have shed insight into the pathophysiology of postimplant loss of residual acoustic hearing. The present study aims to assess the long-term stability of ECoG measures and to establish ECoG as an objective method of monitoring residual hearing over the course of EAS CI use. We hypothesize that repeated measures of ECoG should remain stable over time for EAS CI users with stable postoperative hearing preservation. We also hypothesize that changes in behavioral audiometry for EAS CI users with loss of residual hearing should also be reflected in changes in ECoG measures. DESIGN: A pool of 40 subjects implanted under hearing preservation protocol was included in the study. Subjects were seen at postoperative visits for behavioral audiometry and ECoG recordings. Test sessions occurred 0.5, 1, 3, 6, 12 months, and annually after 12 months postoperatively. Changes in pure-tone behavioral audiometric thresholds relative to baseline were used to classify subjects into two groups: one group with stable acoustic hearing and another group with loss of acoustic hearing. At each test session, ECoG amplitude growth functions for several low-frequency stimuli were obtained. The threshold, slope, and suprathreshold amplitude at a fixed stimulation level was obtained from each growth function at each time point. Longitudinal linear mixed effects models were used to study trends in ECoG thresholds, slopes, and amplitudes for subjects with stable hearing and subjects with hearing loss. RESULTS: Preoperative, behavioral audiometry indicated that subjects had an average low-frequency pure-tone average (125 to 500 Hz) of 40.88 ± 13.12 dB HL. Postoperatively, results showed that ECoG thresholds and amplitudes were stable in EAS CI users with preserved residual hearing. ECoG thresholds increased (worsened) while ECoG amplitudes decreased (worsened) for those with delayed hearing loss. The slope did not distinguish between EAS CI users with stable hearing and subjects with delayed loss of hearing. CONCLUSIONS: These results provide a new application of postoperative ECoG as an objective tool to monitor residual hearing and understand the pathophysiology of delayed hearing loss. While our measures were conducted with custom-designed in-house equipment, CI companies are also designing and implementing hardware and software adaptations to conduct ECoG recordings. Thus, postoperative ECoG recordings can potentially be integrated into clinical practice.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva , Humanos , Estimulación Acústica , Audiometría de Respuesta Evocada/métodos , Implantación Coclear/métodos , Pérdida Auditiva/rehabilitación , Sordera/rehabilitación , Audiometría de Tonos Puros , Umbral Auditivo , Estimulación Eléctrica
2.
eNeuro ; 8(1)2021.
Artículo en Inglés | MEDLINE | ID: mdl-33419861

RESUMEN

There is considerable interest in understanding cortical processing and the function of top-down and bottom-up human neural circuits that control speech production. Research efforts to investigate these circuits are aided by analysis of spectro-temporal response characteristics of neural activity recorded by electrocorticography (ECoG). Further, cortical processing may be altered in the case of hearing-impaired cochlear implant (CI) users, as electric excitation of the auditory nerve creates a markedly different neural code for speech compared with that of the functionally intact hearing system. Studies of cortical activity in CI users typically record scalp potentials and are hampered by stimulus artifact contamination and by spatiotemporal filtering imposed by the skull. We present a unique case of a CI user who required direct recordings from the cortical surface using subdural electrodes implanted for epilepsy assessment. Using experimental conditions where the subject vocalized in the presence (CIs ON) or absence (CIs OFF) of auditory feedback, or listened to playback of self-vocalizations without production, we observed ECoG activity primarily in γ (32-70 Hz) and high γ (70-150 Hz) bands at focal regions on the lateral surface of the superior temporal gyrus (STG). High γ band responses differed in their amplitudes across conditions and cortical sites, possibly reflecting different rates of stimulus presentation and differing levels of neural adaptation. STG γ responses to playback and vocalization with auditory feedback were not different from responses to vocalization without feedback, indicating this activity reflects not only auditory, but also attentional, efference-copy, and sensorimotor processing during speech production.


Asunto(s)
Implantes Cocleares , Percepción del Habla , Estimulación Acústica , Percepción Auditiva , Electrocorticografía , Retroalimentación , Humanos , Habla
3.
Otol Neurotol ; 36(6): 1035-44, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25955750

RESUMEN

OBJECTIVE: Characterize hearing loss (HL) after hearing preservation cochlear implantation and determine the association between high charge electrical stimulation (ES) and late loss of acoustic hearing. METHODS: A retrospective cohort analysis of all hearing preservation implantees at our center (n = 42) assayed HL as a function of maximum charge. We analyzed serial audiometry from 85 patients enrolled in the multicenter Hybrid S8 trial to detail the hearing loss greater than 1 month after implantation. Cochleotypic explant cultures were used to assess susceptibility to high levels of ES. RESULTS: Early HL after implantation tends to be mild and averages 12.2 dB. After activation of the Hybrid S8 device, 17 (20%) of 85 patients experienced acceleration of HL. Compared with the majority of patients who did not lose significant hearing after activation, these patients experienced more severe HL at 1 year. Five patients implanted at our center experienced acceleration of HL after high charge exposure. In patients implanted at our center, high charge was associated with late HL (Pearson 0.366, p = 0.016). In rat cochleotypic explants, high voltage ES damaged afferent nerve fibers, reflected by blebbing and a 50% reduction in the number of fibers innervating the organ of Corti. In contrast, hair cells displayed only minor differences in cell number and morphology. CONCLUSIONS: Based on clinical and in vitro data, we theorize that the combination of acoustic amplification and ES in the setting of intact hair cells and neural architecture may contribute, in part, to cochlear toxicity, perhaps by damaging the afferent innervation.


Asunto(s)
Implantes Cocleares/efectos adversos , Pérdida Auditiva/etiología , Enfermedades del Nervio Vestibulococlear/fisiopatología , Adolescente , Adulto , Vías Aferentes/fisiopatología , Animales , Audiometría , Audiometría de Tonos Puros , Recuento de Células , Niño , Estudios de Cohortes , Estimulación Eléctrica , Femenino , Células Ciliadas Auditivas/patología , Humanos , Masculino , Persona de Mediana Edad , Neuritas , Técnicas de Cultivo de Órganos , Órgano Espiral/patología , Ratas , Estudios Retrospectivos , Ganglio Espiral de la Cóclea/patología , Enfermedades del Nervio Vestibulococlear/complicaciones , Adulto Joven
4.
J Assoc Res Otolaryngol ; 14(3): 435-50, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23519390

RESUMEN

Electrical stimulation of the auditory nerve with a cochlear implant (CI) is the method of choice for treatment of severe-to-profound hearing loss. Understanding how the human auditory cortex responds to CI stimulation is important for advances in stimulation paradigms and rehabilitation strategies. In this study, auditory cortical responses to CI stimulation were recorded intracranially in a neurosurgical patient to examine directly the functional organization of the auditory cortex and compare the findings with those obtained in normal-hearing subjects. The subject was a bilateral CI user with a 20-year history of deafness and refractory epilepsy. As part of the epilepsy treatment, a subdural grid electrode was implanted over the left temporal lobe. Pure tones, click trains, sinusoidal amplitude-modulated noise, and speech were presented via the auxiliary input of the right CI speech processor. Additional experiments were conducted with bilateral CI stimulation. Auditory event-related changes in cortical activity, characterized by the averaged evoked potential and event-related band power, were localized to posterolateral superior temporal gyrus. Responses were stable across recording sessions and were abolished under general anesthesia. Response latency decreased and magnitude increased with increasing stimulus level. More apical intracochlear stimulation yielded the largest responses. Cortical evoked potentials were phase-locked to the temporal modulations of periodic stimuli and speech utterances. Bilateral electrical stimulation resulted in minimal artifact contamination. This study demonstrates the feasibility of intracranial electrophysiological recordings of responses to CI stimulation in a human subject, shows that cortical response properties may be similar to those obtained in normal-hearing individuals, and provides a basis for future comparisons with extracranial recordings.


Asunto(s)
Corteza Auditiva/fisiología , Implantes Cocleares , Estimulación Eléctrica , Femenino , Pérdida Auditiva Sensorineural/inducido químicamente , Pérdida Auditiva Sensorineural/terapia , Humanos , Persona de Mediana Edad
5.
Otol Neurotol ; 31(7): 1041-8, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20634770

RESUMEN

OBJECTIVES: To determine the extent to which electrically evoked compound action potential (ECAP) measurements were related with speech perception performance in implant users with a short electrode array and to investigate the relationship between ECAP measures and performance according to specific devices. DESIGN: Prospective study. SETTING: Tertiary referral center. PATIENTS: Seventeen Hybrid cochlear implant users were tested in this study. Subjects were divided into 2 groups: 8 using the Nucleus Hybrid M and 9 using the Nucleus Hybrid RE. In addition, 21 Nucleus Freedom long electrode implant (CI24RE) users also were tested to compare with the results of the old device (CI24M). MAIN OUTCOME MEASURES: ECAP growth functions were recorded using either an interphase gap (IPG) of 8 or 45 mus. We then calculated the slope of the growth function and changes in sensitivity with IPG. For each subject, these measures were compared with performance on tests of word recognition. RESULTS: The changes in sensitivity using 2 IPGs showed no correlation with the results of word recognition test in Hybrid cochlear implant users. In contrast, relatively strong correlations have been found between the slope of ECAP growth functions and performance on word recognition test. Additionally, when we separate the results of Hybrid M and RE, the slopes of ECAP growth functions from only Hybrid RE CI recipients were significantly correlated with speech performance. The slopes of ECAP growth function in CI24RE users with long electrode also were significantly correlated with performance. However, comparing between 2 independent correlations in RE devices, correlation was higher in Hybrid RE group. CONCLUSION: The results presented in this article support the view that slope of the ECAP growth can show significant correlation to performance with a cochlear implant. Furthermore, these results suggest that the strength of the correlation may be related to the specific device. These results suggest that ECAP measures may be useful in developing a test to predict outcomes with the implant.


Asunto(s)
Potenciales de Acción/fisiología , Implantes Cocleares , Percepción del Habla/fisiología , Adulto , Anciano , Audiometría de Tonos Puros , Sordera/fisiopatología , Sordera/terapia , Estimulación Eléctrica , Electrodos , Electrónica , Diseño de Equipo , Femenino , Pruebas Auditivas , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Telemetría
6.
J Am Acad Audiol ; 21(1): 16-27, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20085196

RESUMEN

BACKGROUND: In the mid-1990s, Cochlear Corporation introduced a cochlear implant (CI) to the market that was equipped with hardware that made it possible to record electrically evoked compound action potentials (ECAPs) from CI users of all ages. Over the course of the next decade, many studies were published that compared ECAP thresholds with levels used to program the speech processor of the Nucleus CI. In 2001 Advanced Bionics Corporation introduced the Clarion CII cochlear implant (the Clarion CII internal device is also known as the CII Bionic Ear). This cochlear implant was also equipped with a system that allowed measurement of the ECAP. While a great deal is known about how ECAP thresholds compare with the levels used to program the speech processor of the Nucleus CI, relatively few studies have reported comparisons between ECAP thresholds and the levels used to program the speech processor of the Advanced Bionics CI. PURPOSE: To explore the relationship between ECAP thresholds and behavioral measures of perceptual dynamic range for the range of stimuli commonly used to program the speech processor of the Advanced Bionics CI. RESEARCH DESIGN: This prospective and experimental study uses correlational and descriptive statistics to define the relationship between ECAP thresholds and perceptual dynamic range measures. STUDY SAMPLE: Twelve postlingually deafened adults participated in this study. All were experienced users of the Advanced Bionics CI system. DATA COLLECTION AND ANALYSIS: ECAP thresholds were recorded using the commercially available SoundWave software. Perceptual measures of threshold (T-level), most comfortable level (M-level), and maximum comfortable level (C-level) were obtained using both "tone bursts" and "speech bursts." The relationship between these perceptual and electrophysiological variables was defined using paired t-tests as well as correlation and linear regression. RESULTS: ECAP thresholds were significantly correlated with the perceptual dynamic range measures studied; however, correlations were not strong. Analysis of the individual data revealed considerable discrepancy between the contour of ECAP threshold versus electrode function and the behavioral loudness estimates used for programming. CONCLUSION: ECAP thresholds recorded from Advanced Bionics cochlear implant users always indicated levels where the programming stimulus was audible for the listener. However, the correlation between ECAP thresholds and M-levels (the primary metric used to program the speech processor of the Advanced Bionics CI), while statistically significant, was quite modest. If programming levels are to be determined on the basis of ECAP thresholds, care should be taken to ensure that stimulation is not uncomfortably loud, particularly on the basal electrodes in the array.


Asunto(s)
Estimulación Acústica/métodos , Umbral Auditivo/fisiología , Implantes Cocleares , Sordera/rehabilitación , Potenciales Evocados Auditivos/fisiología , Percepción Sonora/fisiología , Interfaz Usuario-Computador , Adulto , Anciano , Anciano de 80 o más Años , Sordera/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Telemetría/métodos
7.
Ear Hear ; 30(3): 320-9, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19322089

RESUMEN

OBJECTIVES: The purpose of this study was to determine whether the electrically evoked acoustic change complex (EACC) could be used to assess sensitivity to changes in stimulus level in cochlear implant (CI) recipients and to investigate the relationship between EACC amplitude and rate of growth of the N1-P2 onset response with increases in stimulus level. DESIGN: Twelve postlingually deafened adults using Nucleus CI24 CIs participated in this study. Nucleus Implant Communicator (NIC) routines were used to bypass the speech processor and to control the stimulation of the implant directly. The stimulus consisted of an 800 msec burst of a 1000 pps biphasic pulse train. A change in the stimulus level was introduced 400 msec after stimulus onset. Band-pass filtering (1 to 100 Hz) was used to minimize stimulus artifact. Four to six recordings of 50 sweeps were obtained for each condition, and averaged responses were analyzed in the time domain using standard peak picking procedures. RESULTS: Cortical auditory change potentials were recorded from CI users in response to both increases and decreases in stimulation level. The amplitude of the EACC was found to be dependent on the magnitude of the stimulus change. Increases in stimulus level elicited more robust EACC responses than decreases in stimulus level. Also, EACC amplitudes were significantly correlated with the slope of the growth of the onset response. CONCLUSIONS: This work describes the effect of change in stimulus level on electrically evoked auditory change potentials in CI users. The amplitude of the EACC was found to be related both to the magnitude of the stimulus change introduced and to the rate of growth of the N1-P2 onset response. To the extent that the EACC reflects processing of stimulus change, it could potentially be a valuable tool for assessing neural processing of the kinds of stimulation patterns produced by a CI. Further studies are needed, however, to determine the relationships between the EACC and psychophysical measures of intensity discrimination in CI recipients.


Asunto(s)
Corteza Auditiva/fisiología , Implantes Cocleares , Sordera/fisiopatología , Sordera/terapia , Estimulación Eléctrica , Potenciales Evocados Auditivos/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Percepción Auditiva/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Psicoacústica , Sensibilidad y Especificidad