1.
Radiography (Lond) ; 23(2): 117-124, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28390542

RESUMEN

PURPOSE: The use of cadavers for medical education purposes and for radiology research methodologies which involve subjective image quality evaluation of anatomical criteria is well documented. The aim of this study was to quantify the impact of cadaver tissue preservation in producing MR images that are representative of living tissue by comparing the visualisation of anatomical structures of the ankle obtained from live and cadaver (fresh frozen and Thiel embalmed) specimens through a visual grading analysis (VGA) study. METHODS: A VGA study was conducted on an image data set consisting of 4 coronal proton density weighted (PDw) sequences obtained from ankles of a live patient and those of a cadaveric specimen, of which the right ankle was frozen and the left Thiel embalmed. RESULTS: Comparison of the image quality scores obtained from: the live patient vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) between the scores in favour of the Thiel specimen; between the live patient vs. the frozen specimen indicate a significant difference (p ≤ 0.05) in favour of the frozen specimen and between the frozen vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) in favour of the Thiel specimen. CONCLUSIONS: The advantages of the use of cadavers (frozen or Thiel embalmed) has been shown to also apply for use with proton density (PD) MR imaging. The preservation of cadavers especially using Thiel is a suitable alternative for MRI optimisation and protocol development purposes.


Asunto(s)
Tobillo/anatomía & histología , Embalsamiento/métodos , Congelación , Imagen por Resonancia Magnética/métodos , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Persona de Mediana Edad
2.
Clin Neuroradiol ; 25(3): 233-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24599322

RESUMEN

PURPOSE: The purpose of this study was to investigate the diagnostic efficacy of a range of conventional magnetic resonance imaging (MRI) pulse sequences in the identification of internuclear ophthalmoplegia (INO) caused by medial longitudinal fasciculus (MLF) lesions in multiple sclerosis patients using a receiver-operating characteristic (ROC) methodology. METHODS: A total of 15 clinically confirmed INO and 15 control subjects underwent conventional MRI at 1.5 T consisting of T2-weighted, proton density (PD)-weighted, and fluid-attenuated inversion recovery (FLAIR) sequences, following full institutional approval. A free-response, multiple-reader multiple-case design ROC study was used to evaluate the diagnostic efficacy of each sequence. All imaging sequences were evaluated by 10 board-certified neuroradiologists. Area under the curve (AUC), sensitivity, and specificity were analysed statistically for all three pulse sequences using repeated-measures analyses of variance and post-test analysis using Bonferroni's multiple comparison test of differences. RESULTS: No significant AUC differences were found between the three sequences (p = 0.0697), with T2 recording the highest AUC (0.8346). Sensitivity differences between PD (0.7927) and FLAIR (0.6329) were significant (p < 0.05). Non-significant differences were also evident between T2 and FLAIR (p = 0.0511). The specificity analysis revealed an overall difference (p = 0.0005), with specific inter-sequence differences shown between T2 and PD (p < 0.05) and PD and FLAIR (p < 0.001) with the PD values being lower than those provided with the other two sequences. CONCLUSION: T2-weighted axial imaging through the MLF region resulted in the greatest overall diagnostic efficacy when viewing a combination of mean AUC, sensitivity, and specificity, in terms of the identification of INO-causing lesions.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico , Imagen de Difusión Tensora/métodos , Aumento de la Imagen/métodos , Esclerosis Múltiple/patología , Trastornos de la Motilidad Ocular/patología , Nervio Oculomotor/patología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/complicaciones , Variaciones Dependientes del Observador , Trastornos de la Motilidad Ocular/etiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
3.
Insights Imaging ; 4(5): 637-46, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24006206

RESUMEN

OBJECTIVE: To review knowledge of computed tomography (CT) parameters and their influence on patient dose and image quality amongst a cohort of clinical specialist radiographers (CSRs) and examining radiologists. METHODS: A questionnaire survey was devised and distributed to a cohort of 65 examining radiologists attending the American Board of Radiology exam in Kentucky in November 2011. The questionnaire was later distributed by post to a matching cohort of Irish CT CSRs. Each questionnaire contained 40 questions concerning CT parameters and their influence on both patient dose and image quality. RESULTS: A response rate of 22 % (radiologists) and 32 % (CSRs) was achieved. No difference in mean scores was detected between either group (27.8 ± 4 vs 28.1 ± 4, P = 0.87) although large ranges were noted (18-36). Considerable variations in understanding of CT parameters was identified, especially regarding operation of automatic exposure control and the influence of kilovoltage and tube current on patient dose and image quality. Radiologists were unaware of recommended diagnostic reference levels. Both cohorts were concerned regarding CT doses in their departments. CONCLUSIONS: CT parameters were well understood by both groups. However, a number of deficiencies were noted which may have a considerable impact on patient doses and limit the potential for optimisation in clinical practice. KEY POINTS: • CT users must adapt parameters to optimise patient dose and image quality. • The influence of some parameters is not well understood. • A need for ongoing education in dose optimisation is identified.

4.
Br J Radiol ; 86(1021): 27961545, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22573300

RESUMEN

OBJECTIVE: The current study aims to establish whether detection of solitary pulmonary nodules can be improved by inverting the grey scale of posteroanterior (PA) chests. METHODS: 30 PA chest images were presented on 2 occasions to 16 senior radiologists on either primary or secondary class displays in the standard or inverted mode. 15 images within each group contained a single nodule positioned in a range of anatomical sites. A receiver operating characteristic (ROC) methodology was used to explore differences between the presentation modes. RESULTS: Improved ROC scores were evident with inverted (Az 0.77) compared with standard (Az 0.73) (p=0.02) images; however, this difference was seen only with the primary displays. The benefits seen are most likely owing to increased nodule luminance with the inverted images, particularly when using primary displays. CONCLUSION: This study demonstrates that the inverted image can offer advantages in lung nodule detection over the standard presentation mode when images are viewed on high-specification viewing systems. The study has demonstrated that there is an improvement in the detectability of lung nodules on an inverted image with a primary display monitor that is not evident with secondary displays. This is likely to be the result of increased nodule luminance on primary displays when images are presented in the inverted mode.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Br J Radiol ; 86(1021): 20110812, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23239692

RESUMEN

Objective The current study aims to establish whether detection of solitary pulmonary nodules can be improved by inverting the grey scale of posteroanterior (PA) chests. Methods 30 PA chest images were presented on 2 occasions to 16 senior radiologists on either primary or secondary class displays in the standard or inverted mode. 15 images within each group contained a single nodule positioned in a range of anatomical sites. A receiver operating characteristic (ROC) methodology was used to explore differences between the presentation modes. Results Improved ROC scores were evident with inverted (Az 0.77) compared with standard (Az 0.73) (p=0.02) images; however, this difference was seen only with the primary displays. The benefits seen are most likely owing to increased nodule luminance with the inverted images, particularly when using primary displays. Conclusion This study demonstrates that the inverted image can offer advantages in lung nodule detection over the standard presentation mode when images are viewed on high-specification viewing systems. The study has demonstrated that there is an improvement in the detectability of lung nodules on an inverted image with a primary display monitor that is not evident with secondary displays. This is likely to be the result of increased nodule luminance on primary displays when images are presented in the inverted mode.


Asunto(s)
Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Digit Imaging ; 14(2 Suppl 1): 104-7, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11442065

RESUMEN

The American Board of Radiology is developing a computerized interactive case management examination to be used to evaluate the clinical skills of radiation oncologists. In the past, these skills have been evaluated by a pencil and paper written examination and an oral examination. With the increasing capabilities of computers, these skills can be easily, and perhaps even better, evaluated digitally. The aim is to develop an examination, which will be based on actual clinical cases, and be interactive so that it better mimics the clinical practice of a radiation oncologist than a written examination. It will also be less labor-intensive and less expensive than an oral examination. One of the most important skills of a radiation oncologist is the ability to design treatment portals that will encompass the entire cancer and yet minimize the irradiation of critical tissues and normal organs. Important parameters for radiation oncologists include the direction of the treatment beam, the size and shape of the portals, and the location of the margins of the field relative to patient anatomy and tumor location. In order to evaluate a physician's ability to design treatment portals, the computer-based examination has the capability to interactively construct field lines. The computer interface allows the candidate to draw field lines on a digitized x-ray image in a manner similar to practice. After the candidate illustrates the field lines, the evaluation of the response must be performed quickly to avoid interrupting the flow of the examination. The answer key is stored as a lossless compressed image. The key contains three regions consisting of (1) the must include region, which contains the tumor; (2) the must-exclude region, which contains tissues that if damaged would affect patient vitality and quality of life; and (3) the envelope of acceptable curves. Each region is assigned a unique byte code. The candidate's response is assigned a fourth byte code. Using basic logic operations, the response is swiftly evaluated. The scoring algorithm scores a candidate's action as correct if his/her drawn area encompasses all of the "must-include region" and is within the "envelope of acceptable curves." It scores a candidate's action as incorrect if his/her drawn area overlaps any part of the "exclude region" and/or exceeds at any point the "envelope of acceptable curves."


Asunto(s)
Instrucción por Computador , Oncología por Radiación/educación , Algoritmos , Competencia Clínica , Evaluación Educacional , Humanos
7.
J Digit Imaging ; 14(2 Suppl 1): 27-33, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11442114

RESUMEN

This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.


Asunto(s)
Terminales de Computador , Presentación de Datos/normas , Evaluación Educacional , Radiología/educación , Calibración , Terminales de Computador/normas , Humanos , Control de Calidad , Programas Informáticos , Consejos de Especialidades