Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Endocrinol (Lausanne) ; 15: 1359052, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39157681

RESUMEN

Introduction: Changes to bone physiology play a central role in the development of osteoarthritis with the mechanosensing osteocyte releasing factors that drive disease progression. This study developed a humanised in vitro model to detect osteocyte responses to either interleukin-6, a driver of degeneration and bone remodelling in animal and human joint injury, or mechanical loading, to mimic osteoarthritis stimuli in joints. Methods: Human MSC cells (Y201) were differentiated in 3-dimensional type I collagen gels in osteogenic media and osteocyte phenotype assessed by RTqPCR and immunostaining. Gels were subjected to a single pathophysiological load or stimulated with interleukin-6 with unloaded or unstimulated cells as controls. RNA was extracted 1-hour post-load and assessed by RNAseq. Markers of pain, bone remodelling, and inflammation were quantified by RT-qPCR and ELISA. Results: Y201 cells embedded within 3D collagen gels assumed dendritic morphology and expressed mature osteocytes markers. Mechanical loading of the osteocyte model regulated 7564 genes (Padj p<0.05, 3026 down, 4538 up). 93% of the osteocyte transcriptome signature was expressed in the model with 38% of these genes mechanically regulated. Mechanically loaded osteocytes regulated 26% of gene ontology pathways linked to OA pain, 40% reflecting bone remodelling and 27% representing inflammation. Load regulated genes associated with osteopetrosis, osteoporosis and osteoarthritis. 42% of effector genes in a genome-wide association study meta-analysis were mechanically regulated by osteocytes with 10 genes representing potential druggable targets. Interleukin-6 stimulation of osteocytes at concentrations reported in human synovial fluids from patients with OA or following knee injury, regulated similar readouts to mechanical loading including markers of pain, bone remodelling, and inflammation. Discussion: We have developed a reproducible model of human osteocyte like cells that express >90% of the genes in the osteocyte transcriptome signature. Mechanical loading and inflammatory stimulation regulated genes and proteins implicated in osteoarthritis symptoms of pain as well as inflammation and degeneration underlying disease progression. Nearly half of the genes classified as 'effectors' in GWAS were mechanically regulated in this model. This model will be useful in identifying new mechanisms underlying bone and joint pathologies and testing drugs targeting those mechanisms.


Asunto(s)
Inflamación , Células Madre Mesenquimatosas , Osteoartritis , Osteocitos , Humanos , Osteocitos/metabolismo , Osteocitos/patología , Osteoartritis/patología , Osteoartritis/metabolismo , Inflamación/patología , Inflamación/metabolismo , Células Madre Mesenquimatosas/metabolismo , Células Madre Mesenquimatosas/patología , Interleucina-6/metabolismo , Remodelación Ósea , Células Cultivadas , Diferenciación Celular
2.
J Biomech ; 163: 111913, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38181575

RESUMEN

Advancements in systems for prevention and management of pressure ulcers require a more detailed understanding of the complex response of soft tissues to compressive loads. This study aimed at quantifying the progressive deformation of the buttock based on 3D measurements of soft tissue displacements from MR scans of 10 healthy subjects in a semi-recumbent position. Measurements were obtained using digital volume correlation (DVC) and released as a public dataset. A first parametric optimisation of the global registration step aimed at aligning skeletal elements showed acceptable values of Dice coefficient (around 80%). A second parametric optimisation on the deformable registration method showed errors of 0.99mm and 1.78mm against two simulated fields with magnitude 7.30±3.15mm and 19.37±9.58mm, respectively, generated with a finite element model of the buttock under sitting loads. Measurements allowed the quantification of the slide of the gluteus maximus away from the ischial tuberosity (IT, average 13.74 mm) that was only qualitatively identified in the literature, highlighting the importance of the ischial bursa in allowing sliding. Spatial evolution of the maximus shear strain on a path from the IT to the seating interface showed a peak of compression in the fat, close to the interface with the muscle. Obtained peak values were above the proposed damage threshold in the literature. Results in the study showed the complexity of the deformation of the soft tissues in the buttock and the need for further investigations aimed at isolating factors such as tissue geometry, duration and extent of load, sitting posture and tissue properties.


Asunto(s)
Úlcera por Presión , Sedestación , Humanos , Nalgas , Úlcera por Presión/prevención & control , Postura/fisiología , Muslo
3.
J Mech Behav Biomed Mater ; 142: 105824, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37060717

RESUMEN

Bone fracture surface morphology (FSM) can provide valuable information on the cause of failure in forensic and archaeological applications and it depends primarily on three factors, the loading conditions (like strain rate), the ambient conditions (wet or dry bone material) and the quality of bone material itself. The quality of bone material evidently changes in taphonomy as a result of the decomposition process and that in turn is expected to affect FSM. Porcine bones were fractured by a standardised impact during the course of soft tissue decomposition, at 28-day intervals, over 140 days (equivalent to 638 cooling degree days). Measurements of the associated microcracks on the fractured cortical bone surfaces indicated a progressive increase in mean length during decomposition from around 180 µm-375 µm. The morphology of these microcracks also altered, from multiple intersecting microcracks emanating from a central point at 0-28 cumulative cooling degree days, to longer linear cracks appearing to track lamellae as soft tissue decomposition progressed. The implications of these findings are that taphonomic changes of bone may offer the real possibility of distinguishing perimortem and taphonomic damage and also provide a new surrogate parameter for estimation of post-mortem interval (PMI) in forensics.


Asunto(s)
Antropología Forense , Fracturas Óseas , Porcinos , Animales , Huesos , Autopsia , Medicina Legal
4.
J Mech Behav Biomed Mater ; 140: 105704, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36801778

RESUMEN

Synthetic models (phantoms) of the brain-skull system are useful tools for the study of surgical events that are otherwise difficult to study directly in humans. To date, very few studies can be found which replicate the full anatomical brain-skull system. Such models are required to study the more global mechanical events that can occur in neurosurgery, such as positional brain shift. Presented in this work is a novel workflow for the fabrication of a biofidelic brain-skull phantom which features a full hydrogel brain with fluid-filled ventricle/fissure spaces, elastomer dural septa and fluid-filled skull. Central to this workflow is the utilization of the frozen intermediate curing state of an established brain tissue surrogate, which allows for a novel moulding and skull installation approach that permits a much fuller recreation of the anatomy. The mechanical realism of the phantom was validated through indentation testing of the phantom's brain and simulation of the supine to prone brain shift event, while the geometric realism was validated through magnetic resonance imaging. The developed phantom captured a novel measurement of the supine to prone brain shift event with a magnitude that accurately reproduces that seen in the literature.


Asunto(s)
Cabeza , Hidrogeles , Humanos , Cráneo , Encéfalo , Imagen por Resonancia Magnética , Fantasmas de Imagen
5.
Comput Methods Biomech Biomed Engin ; 26(14): 1719-1731, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36420964

RESUMEN

Microneedle (MN) array patches present a promising new approach for the minimally invasive delivery of therapeutics and vaccines. However, ensuring reproducible insertion of MNs into the skin is challenging. The spacing and arrangement of MNs in an array are critical determinants of skin penetration and the mechanical integrity of the MNs. In this work, the finite element method was used to model the effect of MN spacing on needle reaction force and skin strain during the indentation phase prior to skin penetration. Spacings smaller than 2-3 mm (depending on variables, e.g., skin stretch) were found to significantly increase these parameters.

6.
J R Soc Interface ; 19(197): 20220557, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36514891

RESUMEN

Computational modelling of the brain requires accurate representation of the tissues concerned. Mechanical testing has numerous challenges, in particular for low strain rates, like neurosurgery, where redistribution of fluid is biomechanically important. A finite-element (FE) model was generated in FEBio, incorporating a spring element/fluid-structure interaction representation of the pia-arachnoid complex (PAC). The model was loaded to represent gravity in prone and supine positions. Material parameter identification and sensitivity analysis were performed using statistical software, comparing the FE results to human in vivo measurements. Results for the brain Ogden parameters µ, α and k yielded values of 670 Pa, -19 and 148 kPa, supporting values reported in the literature. Values of the order of 1.2 MPa and 7.7 kPa were obtained for stiffness of the pia mater and out-of-plane tensile stiffness of the PAC, respectively. Positional brain shift was found to be non-rigid and largely driven by redistribution of fluid within the tissue. To the best of our knowledge, this is the first study using in vivo human data and gravitational loading in order to estimate the material properties of intracranial tissues. This model could now be applied to reduce the impact of positional brain shift in stereotactic neurosurgery.


Asunto(s)
Encéfalo , Piamadre , Humanos , Simulación por Computador , Análisis de Elementos Finitos , Estrés Mecánico , Fenómenos Biomecánicos
7.
PLoS One ; 17(11): e0277570, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36367887

RESUMEN

N95/FFP3 respirators have been critical to protect healthcare workers and their patients from the transmission of COVID-19. However, these respirators are characterised by a limited range of size and geometry, which are often associated with fitting issues in particular sub-groups of gender and ethnicities. This study describes a novel methodology which combines magnetic resonance imaging (MRI) of a cohort of individuals (n = 8), with and without a respirator in-situ, and 3D registration algorithm which predicted the goodness of fit of the respirator. Sensitivity analysis was used to optimise a deformation value for the respirator-face interactions and corroborate with the soft tissue displacements estimated from the MRI images. An association between predicted respirator fitting and facial anthropometrics was then assessed for the cohort.


Asunto(s)
COVID-19 , Dispositivos de Protección Respiratoria , Humanos , COVID-19/prevención & control , Respiradores N95 , Ventiladores Mecánicos , Personal de Salud
8.
J Tissue Viability ; 31(1): 73-83, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34238649

RESUMEN

Pressure ulcers (PUs) are a major public health challenge, having a significant impact on healthcare service and patient quality of life. Computational biomechanical modelling has enhanced PU research by facilitating the investigation of pressure responses in subcutaneous tissue and skeletal muscle. Extensive work has been undertaken on PUs on patients in the seated posture, but research into heel ulcers has been relatively neglected. The aim of this review was to address the key challenges that exist in developing an effective FE foot model for PU prevention and the confusion surrounding the wide range of outputs reported. Nine FE foot studies investigating heel ulcers in bedrest were identified and reviewed. Six studies modelled the posterior part of the heel, two included the calf and foot, and one modelled the whole body. Due to the complexity of the foot anatomy, all studies involved simplification or assumptions regarding parts of the foot structure, boundary conditions and material parameters. Simulations aimed to understand better the stresses and strains exhibited in the heel soft tissues of the healthy foot. The biomechanical properties of soft tissue derived from experimental measurements are critical for developing a realistic model and consequently guiding clinical decisions. Yet, little to no validation was reported in each of the studies. If FE models are to address future research questions and clinical applications, then sound verification and validation of these models is required to ensure accurate conclusions and prediction of patient outcomes. Recommendations and considerations for future FE studies are therefore proposed.


Asunto(s)
Úlcera por Presión , Reposo en Cama , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Úlcera por Presión/prevención & control , Calidad de Vida
9.
Sci Rep ; 11(1): 17684, 2021 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-34480073

RESUMEN

Positional brain shift (PBS), the sagging of the brain under the effect of gravity, is comparable in magnitude to the margin of error for the success of stereotactic interventions ([Formula: see text] 1 mm). This non-uniform shift due to slight differences in head orientation can lead to a significant discrepancy between the planned and the actual location of surgical targets. Accurate in-vivo measurements of this complex deformation are critical for the design and validation of an appropriate compensation to integrate into neuronavigational systems. PBS arising from prone-to-supine change of head orientation was measured with magnetic resonance imaging on 11 young adults. The full-field displacement was extracted on a voxel-basis via digital volume correlation and analysed in a standard reference space. Results showed the need for target-specific correction of surgical targets, as a significant displacement ranging from 0.52 to 0.77 mm was measured at surgically relevant structures. Strain analysis further revealed local variability in compressibility: anterior regions showed expansion (both volume and shape change), whereas posterior regions showed small compression, mostly dominated by shape change. Finally, analysis of correlation demonstrated the potential for further patient- and intervention-specific adjustments, as intra-cranial breadth and head tilt correlated with PBS reaching statistical significance.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Posicionamiento del Paciente , Técnicas Estereotáxicas , Cirugía Asistida por Computador/métodos , Adulto , Femenino , Humanos , Imagenología Tridimensional , Masculino , Neuronavegación , Orientación , Adulto Joven
10.
J Biomater Appl ; 35(10): 1235-1252, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33573445

RESUMEN

Poly (methyl methacrylate) (PMMA) bone cement is widely used for anchoring joint arthroplasties. In cement brands approved for these procedures, micron-sized particles (usually barium sulphate, BaSO4) act as the radiopacifier. It has been postulated that these particles act as sites for crack initiation and subsequently cement fatigue. This study investigated whether alternative radiopacifiers, anatase titanium dioxide (TiO2) and yttria-stabilised zirconium dioxide (ZrO2), could improve the in vitro mechanical, fatigue crack propagation and biological properties of polymethyl methacrylate (PMMA) bone cement and whether their coating with a silane could further enhance cement performance. Cement samples containing 0, 5, 10, 15, 20 and 25%w/w TiO2 or ZrO2 and 10%w/w silane-treated TiO2 or ZrO2 were prepared and characterised in vitro in terms of radiopacity, compressive and bending strength, bending modulus, fatigue crack propagation, hydroxyapatite forming ability and MC3T3-E1 cell attachment and viability. Cement samples with greater than 10%w/w TiO2 and ZrO2 had a similar radiopacity to the control 10%w/w BaSO4 cement and commercial products. The addition of TiO2 and ZrO2 to bone cement reduced the bending strength and fracture toughness and increased fatigue crack propagation due to the formation of agglomerations and voids. Silane treating TiO2 reversed this effect, enhancing the dispersion and adhesion of particles to the PMMA matrix and resulted in improved mechanical properties and fatigue crack propagation resistance. Silane-treated TiO2 cements had increased nucleation of hydroxyapatite and MC3T3-E1 cell attachment in vitro, without significantly compromising cell viability. This research has demonstrated that 10%w/w silane-treated anatase TiO2 is a promising alternative radiopacifier for PMMA bone cement offering additional benefits over conventional BaSO4 radiopacifiers.


Asunto(s)
Cementos para Huesos/química , Materiales Biocompatibles Revestidos/química , Polimetil Metacrilato/química , Titanio/química , Circonio/química , Animales , Sulfato de Bario/química , Cementos para Huesos/farmacología , Adhesión Celular/efectos de los fármacos , Línea Celular , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Fuerza Compresiva , Ratones , Tamaño de la Partícula , Silanos/química , Estrés Mecánico , Itrio/química
11.
Comput Methods Biomech Biomed Engin ; 23(11): 675-689, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32396392

RESUMEN

Ball-in-socket metal on metal (MOM) contacts were analysed using the Abaqus Finite Element package to simulate dry contact between the acetabular cup and the femoral head. Different cup thicknesses of 4, 6, 8, and 10 mm were considered using a polyurethane foam block support system. Elastohydrodynamic lubrication (EHL) analyses were developed for the contacts using three different approaches to specify the contact. These were (i) A simple model based on the radii of relative curvature, (ii) An equivalent contact model developed so that its dry contact area and maximum pressure replicated the values obtained from the FE analysis, and (iii) A modified version of (ii) that also ensured equivalence of the gap shape outside the contact area. Published in vivo information for the hip joint contact forces over the walking cycle was used to specify the operating conditions for the EHL analysis. The analysis method was found to be effective for all points of the walking cycle for cases where the cup thickness exceeded 5 mm and modelling approach (ii) was identified as satisfactory. For a cup thickness of 4 mm, membrane action began to emerge in the FE analyses so that such contacts behaved in a different way.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis Articulares de Metal sobre Metal , Acetábulo/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Lubrificación , Diseño de Prótesis , Caminata
12.
J Endocrinol ; 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31454785

RESUMEN

Human Prader-Willi syndrome (PWS) is characterised by impairments of multiple systems including the growth hormone (GH) axis and skeletal growth. To address our lack of knowledge of the influence of PWS on skeletal integrity in mice, we have characterised the endocrine and skeletal phenotype of the PWS-ICdel mouse model for "full" PWS and determined the impact of thermoneutrality. Tibial length, epiphyseal plate width and marrow adiposity were reduced by 6%, 18% and 79% in male PWS-ICdel mice, with osteoclast density being unaffected. Similar reductions in femoral length accompanied a 32% reduction in mid-diaphyseal cortical diameter. Distal femoral Tb.N was reduced by 62%, with individual trabeculae being less plate-like and the lattice being more fragmented (Tb.Pf increased by 63%). Cortical strength (Ultimate moment) was reduced by 26% as a result of reductions in calcified tissue strength and the geometric contribution. GH and prolactin contents in PWS-ICdel pituitaries were reduced in proportion to their smaller pituitary size, with circulating IGF-1 concentration reduced by 37-47%. Conversely, while pituitary LH content was halved, circulating gonadotropin concentrations were unaffected. Although longitudinal growth, marrow adiposity and femoral geometry were unaffected by thermoneutrality, strengthened calcified tissue reversed weakened cortex of PWS-ICdel femora. While underactivity of the GH-axis may be due to loss of Snord116 expression and impaired limb bone geometry and strength due to loss of Magel2 expression, comprehensive analysis of skeletal integrity in the single gene deletion models is required. Our data imply that thermoneutrality may ameliorate the elevated fracture risk associated with PWS.

13.
R Soc Open Sci ; 6(1): 181361, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30800383

RESUMEN

For cellular structures with uniform geometry, cell size and distribution, made from a neo-Hookean material, we demonstrate experimentally that large stretching causes nonlinear scaling effects governed by the microstructural architecture and the large strains at the cell level, which are not predicted by the linear elastic theory. For this purpose, three honeycomb-like structures with uniform square cells in stacked distribution were designed, where the number of cells varied, while the material volume and the ratio between the thickness and the length of the cell walls were fixed. These structures were manufactured from silicone rubber and tested under large uniaxial tension in a bespoke test fixture. Optical strain measurements were used to assess the deformation by capturing both the global displacements of the structure and the local deformations in the form of a strain map. The experimental results showed that, under sufficiently large strains, there was an increase in the stiffness of the structure when the same volume of material was arranged as many small cells compared to when it was organized as fewer larger cells. Finite element simulations confirmed our experimental findings. This study sheds light upon the nonlinear elastic responses of cellular structures in large-strain deformations, which cannot be captured within the linear elasticity framework.

14.
J Neurosci Methods ; 308: 337-345, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30179705

RESUMEN

BACKGROUND: The design and use of convection-enhanced delivery catheters remains an active field as clinical trials have highlighted suboptimal distribution as a contributory factor to the failure of those studies. Recent studies indicate limitations and challenges in achieving target coverage using conventional point source delivery. NEW METHOD: The recessed step catheter(RSC), developed by this group, does not function as a point source delivery device, but instead uses 'controlled reflux' of the infusate to a flow inhibiting recess feature. Here we investigate a range of clinically useful step lengths in agarose gel and investigate proof-of-principle in vivo(n = 5). Infusion morphology was characterised in terms of length, width and distribution volume over a range of flow rates. RESULTS: For a fixed infusion volume, increases in catheter step length strongly correlated with increases in the length and volume of distribution (r>0.90, p < 0.001) whilst there were small reductions in the width of distribution (r<-0.62, p < 0.001). Step lengths below 6 mm produced spherical distributions while steps above 12 mm produced elongated distributions. Increasing peak flow rates resulted in significant reductions in distribution volume at each step length, and an increased risk of reflux beyond the step. Modifications to the infusion morphology using changes in step length were confirmed in vivo. CONCLUSIONS: The combination of the recessed step and the ability to adjust the step length with this catheter design make it highly suitable for tailoring the distribution volume of the infusate to meet specific morphological target volumes in the brain.


Asunto(s)
Encéfalo/fisiología , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Animales , Cateterismo/instrumentación , Cateterismo/métodos , Catéteres , Convección , Sus scrofa
15.
J Forensic Sci ; 63(1): 207-213, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28295357

RESUMEN

The aim of this pilot study was to investigate compositional changes in bone during decomposition. Elemental concentrations of barium, calcium, iron, potassium, magnesium, zinc and phosphorus in porcine bone (as an experimental analog for human bone) were analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The samples were taken from porcine bone subjected to shallow burial and surface depositions at 28-day intervals for a period of 140 days. Results indicated that ICP-OES elemental profiling has potential to be developed as a forensic test for determining whether a bone sample originates from the early stages of soft tissue putrefaction. Significant changes in iron, sodium and potassium concentrations were found over 140 days. These elements are known to be primarily associated with proteins and/or tissue fluids within the bone. Changes in their respective concentrations may therefore be linked to dehydration over time and in turn may be indicative of time since deposition.


Asunto(s)
Huesos/metabolismo , Cambios Post Mortem , Animales , Bario/metabolismo , Entierro , Calcio/metabolismo , Patologia Forense , Humanos , Hierro/metabolismo , Magnesio/metabolismo , Modelos Animales , Fósforo/metabolismo , Proyectos Piloto , Potasio/metabolismo , Sodio/metabolismo , Análisis Espectral , Porcinos , Zinc/metabolismo
16.
R Soc Open Sci ; 4(1): 160585, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28280556

RESUMEN

A new anisotropic viscoelastic model is developed for application to the aortic valve (AV). The directional dependency in the mechanical properties of the valve, arising from the predominantly circumferential alignment of collagen fibres, is accounted for in the form of transverse isotropy. The rate dependency of the valve's mechanical behaviour is considered to stem from the viscous (η) dissipative effects of the AV matrix, and is incorporated as an explicit function of the deformation rate ([Formula: see text]). Model (material) parameters were determined from uniaxial tensile deformation tests of porcine AV specimens at various deformation rates, by fitting the model to each experimental dataset. It is shown that the model provides an excellent fit to the experimental data across all different rates and satisfies the condition of strict local convexity. Based on the fitting results, a nonlinear relationship between η and [Formula: see text] is established, highlighting a 'shear-thinning' behaviour for the AV with increase in the deformation rate. Using the model and these outcomes, the stress-deformation curves of the AV tissue under physiological deformation rates in both the circumferential and radial directions are predicted and presented. To verify the predictive capabilities of the model, the stress-deformation curves of AV specimens at an intermediate deformation rate were estimated and validated against the experimental data at that rate, showing an excellent agreement. While the model is primarily developed for application to the AV, it may be applied without the loss of generality to other collagenous soft tissues possessing a similar structure, with a single preferred direction of embedded collagen fibres.

17.
Proc Inst Mech Eng H ; 231(3): 213-221, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28116977

RESUMEN

A preliminary study of acoustic emission during orthopaedic screw fixation was performed using polyurethane foam as the bone-simulating material. Three sets of screws, a dynamic hip screw, a small fragment screw and a large fragment screw, were investigated, monitoring acoustic-emission activity during the screw tightening. In some specimens, screws were deliberately overtightened in order to investigate the feasibility of detecting the stripping torque in advance. One set of data was supported by load cell measurements to directly measure the axial load through the screw. Data showed that acoustic emission can give good indications of impending screw stripping; such indications are not available to the surgeon at the current state of the art using traditional torque measuring devices, and current practice relies on the surgeon's experience alone. The results suggest that acoustic emission may have the potential to prevent screw overtightening and bone tissue damage, eliminating one of the commonest sources of human error in such scenarios.


Asunto(s)
Tornillos Óseos , Acústica , Fenómenos Biomecánicos , Tornillos Óseos/efectos adversos , Huesos/lesiones , Huesos/cirugía , Análisis de Falla de Equipo , Estudios de Factibilidad , Humanos , Redes Neurales de la Computación , Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/métodos , Torque
18.
J Mech Behav Biomed Mater ; 65: 672-678, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27743942

RESUMEN

The purpose of this study was to determine how the Vickers hardness (HV) of bone varies during soft tissue putrefaction. This has possible forensic applications, notably for determining the postmortem interval. Experimental porcine bone samples were decomposed in surface and burial deposition scenarios over a period of 6 months. Although the Vickers hardness varied widely, it was found that when transverse axial hardness was subtracted from longitudinal axial hardness, the difference showed correlations with three distinct phases of soft tissue putrefaction. The ratio of transverse axial hardness to longitudinal axial hardness showed a similar correlation. A difference of 10 or greater in HV with soft tissue present and signs of minimal decomposition, was associated with a decomposition period of 250 cumulative cooling degree days or less. A difference of 10 (+/- standard error of mean at a 95% confidence interval) or greater in HV associated with marked decomposition indicated a decomposition period of 1450 cumulative cooling degree days or more. A difference of -7 to +8 (+/- standard error of mean at a 95% confidence interval) was thus associated with 250 to 1450 cumulative cooling degree days' decomposition. The ratio of transverse axial HV to longitudinal HV, ranging from 2.42 to 1.54, is a more reliable indicator in this context and is preferable to using negative integers These differences may have potential as an indicator of postmortem interval and thus the time of body deposition in the forensic context.


Asunto(s)
Huesos/fisiología , Antropología Forense/métodos , Cambios Post Mortem , Animales , Entierro , Dureza , Porcinos
19.
Hum Mol Genet ; 25(12): 2404-2416, 2016 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-27106103

RESUMEN

Mitochondrial dysfunction connects metabolic disturbance with numerous pathologies, but the significance of mitochondrial activity in bone remains unclear. We have, therefore, characterized the skeletal phenotype in the Opa3L122P mouse model for Costeff syndrome, in which a missense mutation of the mitochondrial membrane protein, Opa3, impairs mitochondrial activity resulting in visual and metabolic dysfunction. Although widely expressed in the developing normal mouse head, Opa3 expression was restricted after E14.5 to the retina, brain, teeth and mandibular bone. Opa3 was also expressed in adult tibiae, including at the trabecular surfaces and in cortical osteocytes, epiphyseal chondrocytes, marrow adipocytes and mesenchymal stem cell rosettes. Opa3L122P mice displayed craniofacial abnormalities, including undergrowth of the lower mandible, accompanied in some individuals by cranial asymmetry and incisor malocclusion. Opa3L122P mice showed an 8-fold elevation in tibial marrow adiposity, due largely to increased adipogenesis. In addition, femoral length and cortical diameter and wall thickness were reduced, the weakening of the calcified tissue and the geometric component of strength reducing overall cortical strength in Opa3L122P mice by 65%. In lumbar vertebrae reduced vertebral body area and wall thickness were accompanied by a proportionate reduction in marrow adiposity. Although the total biomechanical strength of lumbar vertebrae was reduced by 35%, the strength of the calcified tissue (σmax) was proportionate to a 38% increase in trabecular number. Thus, mitochondrial function is important for the development and maintenance of skeletal integrity, impaired bone growth and strength, particularly in limb bones, representing a significant new feature of the Costeff syndrome phenotype.


Asunto(s)
Desarrollo Óseo/genética , Corea/genética , Errores Innatos del Metabolismo/genética , Mitocondrias/genética , Atrofia Óptica/genética , Proteínas/genética , Paraplejía Espástica Hereditaria/genética , Animales , Encéfalo/crecimiento & desarrollo , Encéfalo/fisiopatología , Corea/fisiopatología , Modelos Animales de Enfermedad , Cabeza/crecimiento & desarrollo , Cabeza/fisiopatología , Humanos , Mandíbula/crecimiento & desarrollo , Mandíbula/fisiopatología , Errores Innatos del Metabolismo/fisiopatología , Ratones , Mitocondrias/patología , Mutación Missense , Atrofia Óptica/fisiopatología , Retina/crecimiento & desarrollo , Retina/fisiopatología , Esqueleto/crecimiento & desarrollo , Esqueleto/fisiopatología , Paraplejía Espástica Hereditaria/fisiopatología , Diente/crecimiento & desarrollo , Diente/fisiopatología
20.
Proc Inst Mech Eng H ; 230(3): 169-74, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26743899

RESUMEN

Electrosurgical vessel sealing has been demonstrated to have benefits for both patients and practitioners, but significant variation in the strength of the seal continues to be a concern. This study aims to examine the variation in electrosurgical seal quality along the length of a porcine common carotid artery and explore the relationships between seal quality, vessel size and morphology. Additionally, the study aimed to investigate the minimum safety threshold for successful seals and the influence of vessel characteristics on meeting this requirement. A total of 35 porcine carotid arteries were sealed using the PlasmaKinetic Open Seal device (Gyrus). Each seal was burst pressure tested and a sample taken for staining with elastin van Gieson's stain, with morphological quantification using image processing software ImageJ. With increasing distance from the bifurcation, there was an increase in seal strength and a reduction in both elastin content and vessel outer diameter. A significant correlation was found between burst pressure with both outer diameter (p < 0.0001) and elastin content (p = 0.001). When considering the safe limits of operation, vessels of less than 5 mm in outer diameter were shown to consistently produce a seal of a sufficient strength (burst pressure > 360 mmHg) irrespective of vessel morphology.


Asunto(s)
Arterias Carótidas/cirugía , Electrocirugia/métodos , Electrocirugia/normas , Animales , Arterias Carótidas/fisiología , Electrocirugia/instrumentación , Modelos Cardiovasculares , Presión , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA