Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 41(1): 72-9, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10025613

RESUMEN

The use of a high-temperature superconducting probe for in vivo magnetic resonance microscopy at 2 T is described. To evaluate the performance of the probe, a series of SNR comparisons are carried out. The SNR increased by a factor of 3.7 compared with an equivalent copper coil. Quantitative measures of the SNR gain are in good agreement with theoretical predictions. A number of issues that are unique to the application of HTS coils are examined, including the difficulty in obtaining homogenous excitation without degrading the SNR of the probe. The use of the HTS probe in transmit-receive mode is simple to implement but results in nonuniform excitation. The effect of using the probe in this mode of operation on the T1 and T2 contrast is investigated. Methods for improving homogeneity are explored, such as employing a transmit volume coil. It is found that the cost of using an external transmit coil is an increased probe noise temperature and a reduced SNR by approximately 30%. Other important aspects of the probe are considered, including the effect of temperature on probe stability. Three-dimensional in vivo imaging sets are acquired to assess the stability of the probe for long scans. High-resolution images of the rat brain demonstrate the utility of the probe for microscopy applications.


Asunto(s)
Encéfalo/fisiología , Calor , Imagen por Resonancia Magnética/métodos , Microscopía/métodos , Animales , Artefactos , Encéfalo/anatomía & histología , Femenino , Procesamiento de Imagen Asistido por Computador , Modelos Teóricos , Ratas , Ratas Endogámicas F344 , Conductividad Térmica
2.
IEEE Trans Biomed Eng ; 43(12): 1197-9, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9214839

RESUMEN

We present the results from sodium magnetic resonance imaging (MRI) experiments using high-temperature superconducting (HTS) receiver coils. Sodium imaging has been shown to have great potential for the assessment of cell integrity but suffers from a substantially lower signal-to-noise ratio (SNR) than that of a hydrogen imaging. The use of an HTS receiver coil was found to significantly increase the SNR relative to an equivalent copper receiver coil at room temperature. The SNR gains afforded by HTS coils can also be used to decrease the imaging time.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Cobre , Conductividad Eléctrica , Diseño de Equipo , Análisis de Fourier , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...