Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 25(14): 16419-16426, 2017 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-28789146

RESUMEN

The spatial configuration of the ion source generated under femtosecond laser interaction with clusters is investigated. While intense laser pulses (36 fs, 60 mJ, intensity of 4 × 1017 W/cm2) propagated in CO2 cluster (~0.22 µm in diameter) media, the shape of the obtained plasma ion source was registered for the first time by means of pinhole imaging method. The remarkable decrease in fast ion yield in the vicinity of the assumed best laser focus near the gas cluster jet axis is observed. Such observed anisotropy of the ion source is suggested to originate from the influence of the laser prepulse destroying clusters in advance to the arrival of the main pulse. The assumption is confirmed by optical shadowgraphy images of the plasma channel and is important for further development of an efficient laser-plasma-based fast ion source. Following the observed geometry of the ion source, the laser intensity limit allowing to accelerate ions to ~100 keV energy range was estimated.

2.
Sci Adv ; 3(6): e1602705, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28630909

RESUMEN

The understanding of fracture phenomena of a material at extremely high strain rates is a key issue for a wide variety of scientific research ranging from applied science and technological developments to fundamental science such as laser-matter interaction and geology. Despite its interest, its study relies on a fine multiscale description, in between the atomic scale and macroscopic processes, so far only achievable by large-scale atomic simulations. Direct ultrafast real-time monitoring of dynamic fracture (spallation) at the atomic lattice scale with picosecond time resolution was beyond the reach of experimental techniques. We show that the coupling between a high-power optical laser pump pulse and a femtosecond x-ray probe pulse generated by an x-ray free electron laser allows detection of the lattice dynamics in a tantalum foil at an ultrahigh strain rate of [Formula: see text] ~2 × 108 to 3.5 × 108 s-1. A maximal density drop of 8 to 10%, associated with the onset of spallation at a spall strength of ~17 GPa, was directly measured using x-ray diffraction. The experimental results of density evolution agree well with large-scale atomistic simulations of shock wave propagation and fracture of the sample. Our experimental technique opens a new pathway to the investigation of ultrahigh strain-rate phenomena in materials at the atomic scale, including high-speed crack dynamics and stress-induced solid-solid phase transitions.

3.
Opt Express ; 23(25): 31991-2005, 2015 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-26698990

RESUMEN

We present experiments dealing with a femtosecond laser-driven cluster-based plasma, where by analyzing the nonlinear phenomenon of satellites of spectral lines of Ar XVII, we revealed the nonlinear phenomenon of the generation of the second harmonic of the laser frequency. For performing this analysis we developed new results in the theory of satellites of spectral lines. From such lineshape analysis we found, in particular, that the efficiency of converting the short (40 fs) intense (3x10¹8 W/cm²) incident laser light into the second harmonic was 2%. This result is in the excellent agreement with the 2-Dimensional Particle-In-Cell (2D PIC) simulation that we also performed. There is also an order of magnitude agreement between the thresholds for the SHG found from the line shape analysis and from the 2D PIC simulations.

4.
Sci Rep ; 5: 17713, 2015 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-26634431

RESUMEN

Here, we report, that by means of direct irradiation of lithium fluoride a (LiF) crystal, in situ 3D visualization of the SACLA XFEL focused beam profile along the propagation direction is realized, including propagation inside photoluminescence solid matter. High sensitivity and large dynamic range of the LiF crystal detector allowed measurements of the intensity distribution of the beam at distances far from the best focus as well as near the best focus and evaluation of XFEL source size and beam quality factor M(2). Our measurements also support the theoretical prediction that for X-ray photons with energies ~10 keV the radius of the generated photoelectron cloud within the LiF crystal reaches about 600 nm before thermalization. The proposed method has a spatial resolution ~0.4-2.0 µm for photons with energies 6-14 keV and potentially could be used in a single shot mode for optimization of different focusing systems developed at XFEL and synchrotron facilities.

5.
Nat Commun ; 4: 1936, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23733009

RESUMEN

The advent of X-ray lasers allowed the realization of compact coherent soft X-ray sources, thus opening the way to a wide range of applications. Here we report the observation of unexpected concentric rings in the far-field beam profile at the output of a two-stage plasma-based X-ray laser, which can be considered as the first manifestation of a mirage phenomenon in X-rays. We have developed a method of solving the Maxwell-Bloch equations for this problem, and find that the experimentally observed phenomenon is due to the emergence of X-ray mirages in the plasma amplifier, appearing as phase-matched coherent virtual point sources. The obtained results bring a new insight into the physical nature of amplification of X-ray radiation in laser-induced plasma amplifiers and open additional opportunities for X-ray plasma diagnostics and extreme ultraviolet lithography.

6.
Appl Opt ; 52(3): 509-15, 2013 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-23338201

RESUMEN

LiF crystal and film detectors were used to measure the far-field fluence profile of a self-amplified spontaneous-emission free-electron laser beam and diffraction imaging with high spatial resolution. In these measurements the photoluminescence (PL) response of LiF crystal and film was compared over a wide range of soft x-ray fluences. It was found that the soft x-ray fluence dependences of LiF crystal and film differ. At low fluence, the LiF crystal shows higher PL response compared to LiF film, while this comparison is the opposite at higher fluence. Accurate measurement of LiF crystal and film PL response is important for precise characterization of the spatial, spectral, and coherence features of x-ray beams across the full profile and in localized areas. For such measurements, crucial LiF detector attributes are high spatial resolution and high dynamic range.

7.
Opt Express ; 20(4): 3424-33, 2012 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-22418101

RESUMEN

Optical features of point defects photoluminescence in LiF crystals, irradiated by soft X-ray pulses of the Free Electron Laser with wavelengths of 17.2 - 61.5 nm, were measured. We found that peak of photoluminescence spectra lies near of 530 nm and are associated with emission of F3+ centers. Our results suggest that redistribution of photoluminescence peak intensity from the red to the green part of the spectra is associated with a shortening of the applied laser pulses down to pico - or femtosecond durations. Dependence of peak intensity of photoluminescence spectra from the soft X-ray irradiation fluence was measured and the absence of quenching phenomena, even at relatively high fluencies was found, which is very important for wide applications of LiF crystal X-ray imaging detectors.

8.
Opt Lett ; 37(5): 884-6, 2012 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-22378426

RESUMEN

X ray radiation as high as 50 keV, including K(α) of Ba and Mo, have been observed from a solid target during the interaction of low energy ~0.65 mJ, 1 kHz 40 femtosecond laser pulses focused in air at atmospheric pressure. Energetic electrons generating such x rays are possibly produced when the field strength in laser pulse wake exceeds the runaway threshold in air. Two dimensional particle-in-cell simulations that include optical field ionization of air and elastic collisions support this mechanism.

9.
Opt Lett ; 36(9): 1614-6, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21540945

RESUMEN

The interaction between a 25 TW laser and Xe clusters at a peak intensity of 1 × 10¹9 W/cm² has been investigated. Xe K-shell x rays, whose energies are approximately 30 keV, were clearly observed with a hard x-ray CCD at 3.4 MPa. Moreover, we studied the yield of the Xe K-shell x rays by changing the pulse duration of the laser at a constant laser energy and found that the pulse duration of 40 fs is better than that of 300 fs for generating Xe K-shell x rays.

10.
Opt Express ; 19(25): 25812-22, 2011 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-22273974

RESUMEN

We observed that increasing the clusters size and laser pulse contrast can enhance the X-ray flux emitted by femtosecond-laser-driven-cluster plasma. By focusing a high contrast laser (10(-10)) on large argon clusters, high flux Kα-like X-rays (around 2.96 keV) is generated with a total flux of 2.5 × 10(11) photons/J in 4π and a conversion efficiency of 1.2 × 10-4. In the case of large Kr clusters, the best total flux for L-shell X-rays is 5.3 × 1011 photons/J with a conversion efficiency of 1.3 × 10-4 and, for the Kα X-ray (12.7 keV), it is 8 × 10(8) photons/J with a conversion efficiency of 1.6 × 10-6. Using this X-ray source, a single-shot high-performance X-ray imaging is demonstrated.


Asunto(s)
Argón/química , Argón/efectos de la radiación , Criptón/química , Criptón/efectos de la radiación , Rayos Láser , Luz , Dispersión de Radiación
11.
Appl Opt ; 48(32): 6271-6, 2009 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-19904327

RESUMEN

We demonstrate in-line phase-contrast imaging of nanothickness foils by using a relatively large, polychromatic, debris-free femtosecond-laser-driven cluster-based plasma soft x-ray source, and a high-resolution, large dynamic range LiF crystal detector. The spatial coherence length of radiation in our setup reached a value of 5 microm on the sample plane, which is enough to observe phase-contrast enhancement in the images registered by the detector placed only a few hundred micrometers behind the object. We have developed a tabletop soft x-ray emission source, which emits radiation within a 4pi sr solid angle, and which allows one to obtain contact and propagation-based phase-contrast imaging of nanostructures with 700 nm spatial resolutions. This advance could be of utility for metrology applications.

12.
Phys Rev E Stat Nonlin Soft Matter Phys ; 79(1 Pt 2): 016407, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19257148

RESUMEN

We employ the Los Alamos suite of atomic physics codes to model the inner-shell x-ray emission spectrum of xenon and compare results with those obtained via high-resolution x-ray spectroscopy of xenon clusters irradiated by 30fs Ti:Sapphire laser pulses. We find that the commonly employed configuration-average approximation breaks down and significant spin-orbit splitting necessitates a detailed level accounting. We reproduce an interesting spectral trend for a series of experimental spectra taken with varying pulse energy for fixed pulse duration. To simulate the experimental measurements at increasing beam energies, we find that spectral modeling requires an increased hot electron fraction, but decreased atomic density and bulk electron temperature. We believe these latter conditions to be a result of partial cluster destruction due to the increased energy in the laser prepulse.

13.
Microsc Res Tech ; 71(12): 839-48, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18785247

RESUMEN

A lithium fluoride (LiF) crystal has been utilized as a new soft X-ray detector to image different biological samples at a high spatial resolution. This new type of image detector for X-ray microscopy has many interesting properties: high resolution (nanometer scale), permanent storage of images, the ability to clear the image and reuse the LiF crystal, and high contrast with greater dynamic range. Cells of the unicellular green algae Chlamydomonas dysosmos and Chlorella sorokiniana, and pollen grains of Olea europea have been used as biological materials for imaging. The biological samples were imaged on LiF crystals by using the soft X-ray contact microscopy and contact micro-radiography techniques. The laser plasma soft X-ray source was generated using a Nd:YAG/Glass laser focused on a solid target. The X-ray energy range for image acquisition was in the water-window spectral range for single shot contact microscopy of very thin biological samples (single cells) and around 1 keV for multishots microradiography. The main aim of this article is to highlight the possibility of using a LiF crystal as a detector for the biological imaging using soft X-ray radiation and to demonstrate its ability to visualize the microstructure within living cells.


Asunto(s)
Chlamydomonas/citología , Chlorella/citología , Fluoruros , Compuestos de Litio , Microscopía/métodos , Olea/citología , Polen/citología , Rayos X , Animales
14.
Microsc Res Tech ; 71(6): 459-68, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18324615

RESUMEN

In this article, a method to reveal the presence of Mg content inside the different parts of leaves of Hedera helix is presented. In fact a sample of a Hedera helix's leaf, commonly characterized by a green and a white side, is analyzed under X-ray radiation. The presence of two zones with different colors in the Hedera helix's leaf has not been explained. In this connection, there are presently three hypotheses to explain the characteristic double-color appearance of the leaf. The first hypothesis suggests a different cytoplasmic inheritance of chloroplasts at the cell division, the second a different allelic composition, homozygote and heterozygote, between the two zones, and finally the third the action of a virus which changes the color properties in the Hedera's leaves. The resulting effect is a different content of "something" between the green and the white side. We utilized X-ray radiation, obtained from a plasma source with a Mg target, to image Hedera helix leaves and we found that the green side of the leaf is highlighted. We may suppose that the reason why the X-rays from a Mg plasma source, allow us to pick up the green side is probably due to the greater presence of the amount of Mg (from chlorophyll or other complexes and/or salts) in the two sides, green and white, of the leaf.


Asunto(s)
Hedera/química , Rayos Láser , Magnesio/análisis , Hojas de la Planta/química , Radiografía/métodos , Rayos X
15.
Microsc Res Tech ; 71(1): 35-41, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17853444

RESUMEN

High contrast imaging of in vivo Chlorella sorokiniana cells with submicron spatial resolution was obtained with a contact water window X-ray microscopy technique using a point-like, laser-plasma produced, water-window X-ray radiation source, and LiF crystals as detectors. This novel type of X-ray imaging detectors is based on photoluminescence of stable electronic point defects, characterized by high intrinsic resolution. The fluorescence images obtained on LiF crystals exposed in single-shot experiments demonstrate the high sensitivity and dynamic range of this new detector. The powerful performances of LiF crystals allowed us to detect the exudates of Chlorella cells in their living medium and their spatial distribution in situ, without any special sample preparation.


Asunto(s)
Chlorella/citología , Fluoruros/química , Compuestos de Litio/química , Microscopía Fluorescente/instrumentación , Rayos X , Chlorella/metabolismo , Cristalización , Microscopía Fluorescente/métodos
16.
Microsc Res Tech ; 69(8): 666-74, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16788990

RESUMEN

In this paper, an application of contact microradiography with soft X-rays for detecting the uptake site of heavy metal in the whole plant leaves is investigated. The X-ray source is a laser-plasma one based on an Nd:glass laser. The soft X-ray radiation emitted from the plasma laser targets of magnesium, iron, and copper can be strongly absorbed in the leaves' regions rich in iron, magnesium, and copper. This absorbance could point to structures in the leaves where these heavy elements are found. In this work, leaves treated with copper sulfate diluted in water at 1, 2, and 5% were imaged by using a copper target, in order to evaluate differences with untreated control leaves. Our results showed that this methodology highlighted the presence of copper in the treated leaves. This new methodology should detect heavy element pollutants inside plants and it should also be a useful analytic tool in phytoremediation studies.


Asunto(s)
Metales Pesados/metabolismo , Microrradiografía/métodos , Plantas/metabolismo , Cobre/metabolismo , Contaminación Ambiental/prevención & control , Hierro/metabolismo , Hojas de la Planta/metabolismo
17.
Microsc Res Tech ; 64(1): 21-9, 2004 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15287015

RESUMEN

A method for detecting cadmium uptake in leaves of Saponaria officinalis doped with a solution of cadmium acetate is described. The technique based on the exposure of dried leaves to X-rays of a wavelength close to that of the metal K-edge could be useful for phytoremediation studies as it could reveal the bioaccumulation in plants due to the treatment either in vivo or in vitro with heavy metals. X-ray microradiography measurements are in agreement with those from peroxidase enzyme assay utilized to follow the oxidative damage induced by heavy metals. At present, as we will see in this report, microradiography has still poorer sensitivity in comparison with enzyme assay, but it has the advantage of being faster, not destructive, and usable even at very high doping levels, where the enzyme assay technique results are fully saturated. Further analysis of the optical density values could lead to a quantitative measurement of the heavy metal in the sample. Thus, the technology developed in this article could be useful for tracing the intake in phytoremediation studies.


Asunto(s)
Acetatos/metabolismo , Cadmio/metabolismo , Microrradiografía/métodos , Hojas de la Planta/efectos de la radiación , Saponaria/efectos de la radiación , Rayos X , Absorción , Peroxidasa/metabolismo , Hojas de la Planta/metabolismo , Saponaria/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA