Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Lancet Neurol ; 15(2): 145-153, 2016 02.
Artículo en Inglés | MEDLINE | ID: mdl-26708675

RESUMEN

BACKGROUND: Moderate cooling after birth asphyxia is associated with substantial reductions in death and disability, but additional therapies might provide further benefit. We assessed whether the addition of xenon gas, a promising novel therapy, after the initiation of hypothermia for birth asphyxia would result in further improvement. METHODS: Total Body hypothermia plus Xenon (TOBY-Xe) was a proof-of-concept, randomised, open-label, parallel-group trial done at four intensive-care neonatal units in the UK. Eligible infants were 36-43 weeks of gestational age, had signs of moderate to severe encephalopathy and moderately or severely abnormal background activity for at least 30 min or seizures as shown by amplitude-integrated EEG (aEEG), and had one of the following: Apgar score of 5 or less 10 min after birth, continued need for resuscitation 10 min after birth, or acidosis within 1 h of birth. Participants were allocated in a 1:1 ratio by use of a secure web-based computer-generated randomisation sequence within 12 h of birth to cooling to a rectal temperature of 33·5°C for 72 h (standard treatment) or to cooling in combination with 30% inhaled xenon for 24 h started immediately after randomisation. The primary outcomes were reduction in lactate to N-acetyl aspartate ratio in the thalamus and in preserved fractional anisotropy in the posterior limb of the internal capsule, measured with magnetic resonance spectroscopy and MRI, respectively, within 15 days of birth. The investigator assessing these outcomes was masked to allocation. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00934700, and with ISRCTN, as ISRCTN08886155. FINDINGS: The study was done from Jan 31, 2012, to Sept 30, 2014. We enrolled 92 infants, 46 of whom were randomly assigned to cooling only and 46 to xenon plus cooling. 37 infants in the cooling only group and 41 in the cooling plus xenon group underwent magnetic resonance assessments and were included in the analysis of the primary outcomes. We noted no significant differences in lactate to N-acetyl aspartate ratio in the thalamus (geometric mean ratio 1·09, 95% CI 0·90 to 1·32) or fractional anisotropy (mean difference -0·01, 95% CI -0·03 to 0·02) in the posterior limb of the internal capsule between the two groups. Nine infants died in the cooling group and 11 in the xenon group. Two adverse events were reported in the xenon group: subcutaneous fat necrosis and transient desaturation during the MRI. No serious adverse events were recorded. INTERPRETATION: Administration of xenon within the delayed timeframe used in this trial is feasible and apparently safe, but is unlikely to enhance the neuroprotective effect of cooling after birth asphyxia. FUNDING: UK Medical Research Council.


Asunto(s)
Anestésicos por Inhalación/farmacología , Asfixia Neonatal/terapia , Hipotermia Inducida/métodos , Cápsula Interna/diagnóstico por imagen , Evaluación de Resultado en la Atención de Salud , Tálamo/diagnóstico por imagen , Xenón/farmacología , Acidosis/etiología , Anestésicos por Inhalación/administración & dosificación , Anestésicos por Inhalación/efectos adversos , Puntaje de Apgar , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Asfixia Neonatal/complicaciones , Terapia Combinada , Estudios de Factibilidad , Femenino , Humanos , Recién Nacido , Ácido Láctico/metabolismo , Imagen por Resonancia Magnética , Masculino , Resucitación , Método Simple Ciego , Xenón/administración & dosificación , Xenón/efectos adversos
2.
J Digit Imaging ; 26(5): 886-90, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23619930

RESUMEN

Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging data sets for population phenotyping. It integrates a mature image archival system with an intuitive web-based user interface that provides visualisation and export functionality. In addition, utilities for auditing, data migration and system monitoring are included in a virtual machine image that is easily deployed with minimal configuration. The result is a freely available turnkey solution, designed to support epidemiological and imaging genetics research. It allows the management of patient data sets in a secure, scalable manner without requiring the installation of any bespoke software on end users' workstations. MRIdb is an open-source software, available for download at http://www3.imperial.ac.uk/bioinfsupport/resources/software/mridb .


Asunto(s)
Sistemas de Administración de Bases de Datos , Imagen por Resonancia Magnética , Sistemas de Información Radiológica , Bases de Datos Factuales , Humanos , Interfaz Usuario-Computador
3.
Neuroimage ; 63(2): 663-73, 2012 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-22776460

RESUMEN

In the rodent brain the hemodynamic response to a brief external stimulus changes significantly during development. Analogous changes in human infants would complicate the determination and use of the hemodynamic response function (HRF) for functional magnetic resonance imaging (fMRI) in developing populations. We aimed to characterize HRF in human infants before and after the normal time of birth using rapid sampling of the blood oxygen level dependent (BOLD) signal. A somatosensory stimulus and an event related experimental design were used to collect data from 10 healthy adults, 15 sedated infants at term corrected post menstrual age (PMA) (median 41+1 weeks), and 10 preterm infants (median PMA 34+4 weeks). A positive amplitude HRF waveform was identified across all subject groups, with a systematic maturational trend in terms of decreasing time-to-peak and increasing positive peak amplitude associated with increasing age. Application of the age-appropriate HRF models to fMRI data significantly improved the precision of the fMRI analysis. These findings support the notion of a structured development in the brain's response to stimuli across the last trimester of gestation and beyond.


Asunto(s)
Encéfalo/crecimiento & desarrollo , Hemodinámica/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Encéfalo/irrigación sanguínea , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Adulto Joven
4.
Neuroimage ; 50(4): 1427-37, 2010 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20114082

RESUMEN

As population-based studies may obtain images from scanners with different field strengths, a method to normalize regional brain volumes according to intracranial volume (ICV) independent of field strength is needed. We found systematic differences in ICV estimation, tested in a cohort of healthy subjects (n=5) that had been imaged using 1.5T and 3T scanners, and confirmed in two independent cohorts. This was related to systematic differences in the intensity of cerebrospinal fluid (CSF), with higher intensities for CSF located in the ventricles compared with CSF in the cisterns, at 3T versus 1.5T, which could not be removed with three different applied bias correction algorithms. We developed a method based on tissue probability maps in MNI (Montreal Neurological Institute) space and reverse normalization (reverse brain mask, RBM) and validated it against manual ICV measurements. We also compared it with alternative automated ICV estimation methods based on Statistical Parametric Mapping (SPM5) and Brain Extraction Tool (FSL). The proposed RBM method was equivalent to manual ICV normalization with a high intraclass correlation coefficient (ICC=0.99) and reliable across different field strengths. RBM achieved the best combination of precision and reliability in a group of healthy subjects, a group of patients with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and can be used as a common normalization framework.


Asunto(s)
Encéfalo/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Anciano , Algoritmos , Enfermedad de Alzheimer/patología , Automatización , Encéfalo/patología , Ventrículos Cerebrales/anatomía & histología , Ventrículos Cerebrales/patología , Líquido Cefalorraquídeo , Trastornos del Conocimiento/patología , Estudios de Cohortes , Humanos , Tamaño de los Órganos , Probabilidad , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA