Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Front Cardiovasc Med ; 11: 1353096, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38572307

RESUMEN

The treatment of outflow tract ventricular arrhythmias (OTVA) through radiofrequency ablation requires the precise identification of the site of origin (SOO). Pinpointing the SOO enhances the likelihood of a successful procedure, reducing intervention times and recurrence rates. Current clinical methods to identify the SOO are based on qualitative analysis of pre-operative electrocardiograms (ECG), heavily relying on physician's expertise. Although computational models and machine learning (ML) approaches have been proposed to assist OTVA procedures, they either consume substantial time, lack interpretability or do not use clinical information. Here, we propose an alternative strategy for automatically predicting the ventricular origin of OTVA patients using ML. Our objective was to classify ventricular (left/right) origin in the outflow tracts (LVOT and RVOT, respectively), integrating ECG and clinical data from each patient. Extending beyond differentiating ventricle origin, we explored specific SOO characterization. Utilizing four databases, we also trained supervised learning models on the QRS complexes of the ECGs, clinical data, and their combinations. The best model achieved an accuracy of 89%, highlighting the significance of precordial leads V1-V4, especially in the R/S transition and initiation of the QRS complex in V2. Unsupervised analysis revealed that some origins tended to group closer than others, e.g., right coronary cusp (RCC) with a less sparse group than the aortic cusp origins, suggesting identifiable patterns for specific SOOs.

2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
3.
Ann Cardiothorac Surg ; 13(1): 31-43, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38380136

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia in the adult population and catheter ablation has emerged as an important rhythm-control strategy and is the most common cardiac ablation procedure performed worldwide. The antiarrhythmic drugs have demonstrated moderate efficacy in long-term maintenance of sinus rhythm; moreover, they are often not tolerated and are associated with adverse events. Catheter ablation has proven to be effective in treating AF, although long-term outcomes have been significantly less favorable in persistent AF than in paroxysmal. The current guidelines recommend catheter ablation as class I indication for patients whom antiarrhythmic drugs have failed or are not tolerated, and as first-line rhythm-control therapy in selected patients with symptomatic AF. Advances in technology and innovative ablation protocols resulted in a remarkable improvement of the efficacy outcomes after pulmonary vein isolation. This review seeks to provide an updated report of the current practices and approaches, and to describe the latest advances in technology that aim to improve procedural safety, efficacy and to reduce procedural requirements in terms of duration and fluoroscopy exposure.

4.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38375690

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) detects myocardial scarring, a risk factor for ventricular arrhythmias (VAs) in hypertrophic cardiomyopathy (HCM). The LGE-CMR distinguishes core, borderzone (BZ) fibrosis, and BZ channels, crucial components of re-entry circuits. We studied how scar architecture affects inducibility and electrophysiological traits of VA in HCM. METHODS AND RESULTS: We correlated scar composition with programmed ventricular stimulation-inducible VA features using LGE intensity maps. Thirty consecutive patients were enrolled. Thirteen (43%) were non-inducible, 6 (20%) had inducible non-sustained, and 11 (37%) had inducible sustained mono (MMVT)- or polymorphic VT/VF (PVT/VF). Of 17 induced VA, 13 (76%) were MMVT that either ended spontaneously, persisted as sustained monomorphic, or degenerated into PVT/VF. Twenty-seven patients (90%) had LGE. Of these, 17 (57%) had non-sustained or sustained inducible VA. Scar mass significantly increased (P = 0.002) from non-inducible to inducible non-sustained and sustained VA patients in both the BZ and core components. Borderzone channels were found in 23%, 67%, and 91% of non-inducible, inducible non-sustained, and inducible sustained VA patients (P = 0.003). All 13 patients induced with MMVT or monomorphic-initiated PVT/VF had LGE. The origin of 10/13 of these VTs matched scar location, with 8/10 of these LGE regions showing BZ channels. During follow-up (20 months, interquartile range: 7-37), one patient with BZ channels and inducible PVT had an ICD shock for VF. CONCLUSION: Scar architecture determines inducibility and electrophysiological traits of VA in HCM. Larger studies should explore the role of complex LGE patterns in refining risk assessment in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Canal de Sodio Activado por Voltaje NAV1.5/deficiencia , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Cicatriz/complicaciones , Cicatriz/patología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Medios de Contraste , Gadolinio/farmacología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones
7.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38011712

RESUMEN

AIMS: Epicardial adipose tissue might promote atrial fibrillation (AF) in several ways, including infiltrating the underlying atrial myocardium. However, the role of this potential mechanism has been poorly investigated. The aim of this study is to evaluate the presence of left atrial (LA) infiltrated adipose tissue (inFAT) by analysing multi-detector computer tomography (MDCT)-derived three-dimensional (3D) fat infiltration maps and to compare the extent of LA inFAT between patients without AF history, with paroxysmal, and with persistent AF. METHODS AND RESULTS: Sixty consecutive patients with AF diagnosis (30 persistent and 30 paroxysmal) were enrolled and compared with 20 age-matched control; MDCT-derived images were post-processed to obtain 3D LA inFAT maps for all patients. Volume (mL) and mean signal intensities [(Hounsfield Units (HU)] of inFAT (HU -194; -5), dense inFAT (HU -194; -50), and fat-myocardial admixture (HU -50; -5) were automatically computed by the software. inFAT volume was significantly different across the three groups (P = 0.009), with post-hoc pairwise comparisons showing a significant increase in inFAT volume in persistent AF compared to controls (P = 0.006). Dense inFAT retained a significant difference also after correcting for body mass index (P = 0.028). In addition, more negative inFAT radiodensity values were found in AF patients. Regional distribution analysis showed a significantly higher regional distribution of LA inFAT at left and right superior pulmonary vein antra in AF patients. CONCLUSION: Persistent forms of AF are associated with greater degree of LA intramyocardial adipose infiltration, independently of body mass index. Compared to controls, AF patients present higher LA inFAT volume at left and right superior pulmonary vein antra.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Atrios Cardíacos/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía , Ablación por Catéter/métodos
8.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37724686

RESUMEN

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Asunto(s)
Cardiomiopatía Hipertrófica , Desfibriladores Implantables , Humanos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/terapia , Bradicardia , Progresión de la Enfermedad , Adenosina Trifosfato
9.
Heart Rhythm ; 20(9): 1279-1286, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37329936

RESUMEN

BACKGROUND: Cardioneuroablation (CNA) is a novel treatment for reflex syncope. The effect of aging on CNA efficacy is not fully understood. OBJECTIVE: The purpose of this study was to assess the impact of aging on candidacy and efficacy of CNA for treating vasovagal syncope (VVS), carotid sinus syndrome (CSS), and functional bradyarrhythmia. METHODS: The ELEGANCE (cardionEuroabLation: patiEnt selection, imaGe integrAtioN and outComEs) multicenter study assessed CNA in patients with reflex syncope or severe functional bradyarrhythmia. Patients underwent pre-CNA Holter electrocardiography (ECG), head-up tilt testing (HUT), and electrophysiological study. CNA candidacy and efficacy was assessed in 14 young (18-40 years), 26 middle-aged (41-60 years), and 20 older (>60 years) patients. RESULTS: Sixty patients (37 men; mean age 51 ± 16 years) underwent CNA. The majority (80%) had VVS, 8% had CSS, and 12% had functional bradycardia/atrioventricular block. Pre-CNA Holter ECG, HUT, and electrophysiological findings did not differ across age groups. Acute CNA success was 93%, without differences between age groups (P = .42). Post-CNA HUT response was negative in 53%, vasodepressor in 38%, cardioinhibitory in 7%, and mixed in 2%, without differences across age groups (P = .59). At follow-up (8 months, interquartile range 4-15), 53 patients (88%) were free of symptoms. Kaplan-Meier curves did not show differences in event-free survival between age groups (P = .29). The negative predictive value of a negative HUT was 91.7%. CONCLUSION: CNA is a viable treatment for reflex syncope and functional bradyarrhythmia in all ages, and is highly effective in mixed VVS. HUT is a key step in postablation clinical assessment.


Asunto(s)
Síncope Vasovagal , Masculino , Persona de Mediana Edad , Humanos , Adulto , Anciano , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirugía , Bradicardia/diagnóstico , Bradicardia/cirugía , Selección de Paciente , Síncope/diagnóstico , Pruebas de Mesa Inclinada/métodos , Envejecimiento , Reflejo
13.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37125968

RESUMEN

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Resultado del Tratamiento
14.
J Interv Card Electrophysiol ; 66(9): 1979-1988, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36877415

RESUMEN

BACKGROUND: Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation. METHODS: In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms. RESULTS: 128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71). CONCLUSIONS: The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Catéteres
16.
J Interv Card Electrophysiol ; 66(8): 1877-1888, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36795268

RESUMEN

BACKGROUND: To predict the outflow tract ventricular arrhythmias (OTVA) site of origin (SOO) before the ablation procedure has important practical implications. The present study sought to prospectively evaluate the accuracy of a clinical and electrocardiographic hybrid algorithm (HA) for the prediction of OTVAs-SOO, and at the same time to develop and to prospectively validate a new score with improved discriminatory capacity. METHODS: In this multicenter study, we prospectively enrolled consecutive patients referred for OTVA ablation (N = 202), and we divided them in a derivation sample and a validation cohort. Surface ECGs during OTVA were analyzed to compare previous published ECG-only criteria and to develop a new score. RESULTS: In the derivation sample (N = 105), the correct prediction rate of HA and ECG-only criteria ranged from 74 to 89%. R-wave amplitude in V3 was the best ECG parameter for discriminating LVOT origin in V3 precordial transition (V3PT) patients, and was incorporated to the novel weighted hybrid score (WHS). WHS correctly classified 99 (94.2%) patients, presenting 90% sensitivity and 96% specificity (AUC 0.97) in the entire population; WHS mantained a 87% sensitivity and 91% specificity (AUC 0.95) in patients with V3PT subgroup. The high discriminatory capacity was confirmed in the validation sample (N = 97): the WHS exhibited an AUC (0.93), and a WHS ≥ 2 allowed a correct prediction of LVOT origin in 87 (90.0%) cases, yielding a sensitivity of 87% and specificity of 90%; moreover, the V3PT subgroup showed an AUC of 0.92, and a punctuation ≥ 2 predicted an LVOT origin with a sensitivity of 94% and specificity of 78%. CONCLUSIONS: The novel hybrid score has proved to accurately anticipate the OTVA's origin, even in those with a V3 precordial transition. A Weighted hybrid score. B Typical examples of the use of the weighted hybrid score. C ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the derivation cohort. D ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the V3 precordial transition OTVA subgroup.

18.
J Perinat Med ; 51(4): 550-558, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-36420537

RESUMEN

OBJECTIVES: Shone's complex (SC) is characterized by sequential obstructions of left ventricular (LV) inflow and outflow. It can be associated with poor long-term prognosis when compared to Simple-Aortic Coarctation (S-CoA). We aimed to assess whether the degree of ventricular disproportion and 2D-speckle-tracking echocardiography (2D-STE) could improve the accuracy of prenatal prediction of SC. METHODS: 75 consecutive fetuses were retrospectively enrolled from January 2010 to June 2021. Fetuses were divided into 4 groups (Group 1: SC; Group 2: S-CoA; Group 3: False Positive-Coarctation of the Aorta [FP-CoA]; group 4: controls). Comparisons for echocardiographic measures and myocardial deformation indices were performed. A receiver operating characteristic (ROC) analysis was performed on the MV/TV (mitral valve/tricuspid valve ratio) and LV GLS (global longitudinal strain) values to identify cut-offs to separate group 1 and 2 fetuses. RESULTS: SC fetuses showed a significant reduction in MV/TV when compared to S-CoA and FP-CoA fetuses (p<0.001). LV GLS in SC fetuses was significantly reduced compared to S-CoA fetuses (-13.3 ± 2.1% vs. -17.0 ± 2.2%, p=0.001). A cut-off value of 0.59 for MV/TV and -15.35% for LV GLS yielded a sensitivity of 76 and 82% and a specificity of 71 and 83% respectively in separating SC vs. S-CoA fetuses. CONCLUSIONS: SC fetuses showed a more severe degree of ventricular disproportion and a lower LV GLS compared to S-CoA, FP-CoA and control fetuses. MV/TV and GLS are both predictors of SC. These findings may improve the quality of prenatal parental counselling.


Asunto(s)
Coartación Aórtica , Embarazo , Femenino , Humanos , Estudios Retrospectivos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/complicaciones , Ecocardiografía , Curva ROC , Feto , Función Ventricular Izquierda
19.
J Interv Card Electrophysiol ; 66(1): 39-47, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36227461

RESUMEN

BACKGROUND: Recent studies showed that an early strategy for ventricular tachycardia (VT) ablation resulted in reduction of VT episodes or mortality. Cardiac magnetic resonance (CMR)-derived border zone channel (BZC) mass has proved to be a strong non-invasive predictor of VT in post-myocardial infarction (MI). CMR-guided VT substrate ablation proved to be safe and effective for reducing sudden cardiac death (SCD) and VA occurrence. METHODS: PREVENT-VT is a prospective, randomized, multicenter, and controlled trial designed to evaluate the safety and efficacy of prophylactic CMR-guided VT substrate ablation in chronic post-MI patients with CMR-derived arrhythmogenic scar characteristics. Chronic post-MI patients with late gadolinium enhancement (LGE) CMR will be evaluated. CMR images will be post-processed and the BZC mass measured: patients with a BZC mass > 5.15 g will be eligible. Consecutive patients will be enrolled at 3 centers and randomized on a 1:1 basis to undergo a VT substrate ablation (ABLATE arm) or optimal medical treatment (OMT arm). Primary prevention ICD will be implanted following guideline recommendations, while non-ICD candidates will be implanted with an implantable cardiac monitor (ICM). The primary endpoint is a composite outcome of sudden cardiac death (SCD) or sustained monomorphic VT, either treated by an ICD or documented with ICM. Secondary endpoints are procedural safety and efficiency outcomes of CMR-guided ablation. DISCUSSION: In some patients, the first VA episode causes SCD or severe neurological damage. The aim of the PREVENT-VT is to evaluate whether primary preventive substrate ablation may be a safe and effective prophylactic therapy for reducing SCD and VA occurrence in patients with previous MI and high-risk scar characteristics based on CMR. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04675073, registered on January 1, 2021.


Asunto(s)
Ablación por Catéter , Infarto del Miocardio , Taquicardia Ventricular , Humanos , Medios de Contraste , Estudios Prospectivos , Cicatriz/diagnóstico por imagen , Cicatriz/cirugía , Cicatriz/etiología , Gadolinio , Arritmias Cardíacas/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/cirugía , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Ablación por Catéter/métodos
20.
Am Heart J ; 255: 94-105, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36272451

RESUMEN

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico , Angiografía Coronaria , Infarto del Miocardio/diagnóstico , Electrocardiografía/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...