Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 201
Filtrar
1.
Clin Res Cardiol ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196345

RESUMEN

BACKGROUND AND AIMS: The impact of mitral regurgitation (MR) in asymptomatic patients is not well defined. We aimed to determine the prevalence of MR-related complications and their association with 10-year survival in a large unselected asymptomatic MR cohort. METHODS: Health insurance claims data from Germany's second largest health insurance fund, BARMER, which maintains longitudinal data on 8.7 million German residents, were retrospectively analyzed. All patients with an outpatient diagnosis of MR in a minimum of two quarters during a calendar year and first recorded diagnosis between 2008 and 2011 were included. Patients with any complication attributable to MR or mitral valve intervention at index were excluded. Outcomes were compared between study group and age- and sex-matched controls (i.e., without known cardiac disease). MR-related complications of interest were new congestive heart failure, new-onset atrial fibrillation, pulmonary hypertension, or cardiac decompensation. RESULTS: A total of 56,577 individuals (median age 68 years, 67% female) with asymptomatic MR were identified. At 10 years, MR-related complications were more frequent in the study group vs. control group (46.5% vs. 20.8%, OR 3.31, P < 0.0001). Furthermore, MR-related complications were more common in male vs. female patients with an asymptomatic MR (OR 2.65, P < 0.0001). The occurrence of at least one MR-related complication was associated with a reduced 10-year survival (OR 1.80, P < 0.0001). CONCLUSIONS: Almost half of patients with asymptomatic MR experience complications during a 10 year follow-up which result in impaired survival. These results imply the necessity of long-term disease management program. Furthermore, decision-making process and timing for mitral valve intervention in asymptomatic patients should be reevaluated.

2.
Clin Res Cardiol ; 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38117299

RESUMEN

BACKGROUND: Anxiety and limited patient comprehension may pose significant barriers when informing elderly patients about complex procedures such as transcatheter aortic valve implantation (TAVI). OBJECTIVES: We aimed to evaluate the utility of medical graphics to improve the patient informed consent (IC) before TAVI. METHODS: In this prospective, randomized dual center study, 301 patients were assigned to a patient brochure containing medical graphics (Comic group, n = 153) or sham information (Control group, n = 148) on top of usual IC. Primary outcomes were patient understanding of central IC-related aspects and periprocedural anxiety assessed by the validated Spielberger State Trait Anxiety Inventory (STAI), both analyzed by cognitive status according to the Montreal Cognitive Assessment (MoCA). RESULTS: Patient understanding was significantly higher in the Comic group [mean number of correct answers 12.8 (SD 1.2) vs. 11.3 (1.8); mean difference 1.5 (95% CI 1.2-1.8); p < 0.001]. This effect was more pronounced in the presence of cognitive dysfunction (MoCA < 26) [12.6 (1.2) in the Comic vs. 10.9 (1.6) in the Control group; mean difference 1.8 (1.4-2.2), p < 0.001]. Mean STAI score declined by 5.7 (95% CI 5.1-6.3; p < 0.001) in the Comic and 0.8 points (0.2-1.4; p = 0.015) in the Control group. Finally, mean STAI score decreased in the Comic group by 4.7 (3.8-5.6) in cognitively impaired patients and by 6.6 (95% CI 5.8 to 7.5) in patients with normal cognitive function (p < 0.001 each). CONCLUSIONS: Our results prove beneficial effects for using medical graphics to inform elderly patients about TAVI by improving patient understanding and reducing periprocedural anxiety (DRKS00021661; 23/Oct/2020). Medical graphics entailed significant beneficial effects on the primary endpoints, patient understanding and periprocedural anxiety, compared to the usual patient informed consent (IC) procedure. Patient understanding of IC-related aspects was significantly higher in the Comic group, with a more pronounced benefit in patients with cognitive impairment (p for IC method and cognitive status < 0.001, respectively; p for IC method x MoCA category interaction = 0.017). There further was a significant decline of periprocedural anxiety in patients with and without cognitive impairment (p for IC method x measuring time point < 0.001; p for IC method x MoCA category x measuring time point interaction = 0.018).

3.
J Heart Lung Transplant ; 41(6): 810-817, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35422347

RESUMEN

BACKGROUND: The majority (89%) of left ventricular assist device (LVAD) patients have an implantable cardioverter-defibrillator (ICD) in place. Due to the advances of modern-day LVAD therapy, more patients are on support for longer. This inevitably leads to more LVAD patients facing ICD generator battery depletion. Until now, there are insufficient data regarding periprocedural risks of generator replacements in a high-risk group like the LVAD cohort. METHODS: A retrospective, single-center analysis of pocket-related outcomes of all ICD generator replacements in LVAD and Non-LVAD patients between January 2014 and December 2018. The primary outcome was the combined endpoint of clinically significant pocket hematoma and/or cardiac implantable electronic device (CIED) infection in the first 6 months after ICD generator exchange. The clinically significant hematoma was defined as hematoma requiring reoperation, prolongation of hospitalization, or interruption of anticoagulation. The cumulative incidence function was calculated for the primary endpoint. RESULTS: Two hundred seventy-seven patients underwent ICD generator exchange in our clinic in this time. Of these, 251 patients had a complete 6-month follow-up regarding clinically significant pocket hematomas and pocket infections. One hundred ninety patients had no LVAD, and 61 patients were on LVAD support. The rate of the primary combined endpoint clinically significant pocket hematoma and/or CIED infection was 3.5 times higher in LVAD patients compared to the non-LVAD cohort (event rate 39.14 vs 11.07 per 100 patient-years, p = 0.048). Clinically significant pocket hematomas necessitating revision occurred nearly 4 times more often in the LVAD group (p = 0.042). Pocket device infection rates were around 16 times higher in LVAD patients compared to non-LVAD patients (p = 0.002). CONCLUSIONS: Compared to Non-LVAD patients, LVAD patients exhibit a relevant higher rate of clinically significant pocket hematoma and CIED infection after ICD generator exchange. This information should additionally be considered in the decision-making process regarding the indication for ICD generator exchange.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Hematoma/epidemiología , Hematoma/etiología , Humanos , Estudios Retrospectivos
4.
Int J Pharm ; 604: 120747, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34051320

RESUMEN

Granular materials are part of the design, production and final products of different industrial sectors. Powder flowability is a major topic in manufacturing and transport as it is closely related to process feasibility. Nonetheless, the flows of granular materials are not easy to describe or quantify, even in the simple case of dry monodisperse cohesionless particles. Flowability assessment is not a standard or normalized issue; still, no test is able predict powder flow behavior in all the different mechanical situations encountered during processing. This study aims (1) to evaluate flowability, as device-related, through the force or the energy supplied to the powder bed and (2) to study the effect of glidants and moisture content on flowability. To illustrate these aims, the flowability of two well-known pharmaceutical excipients, Avicel® PH-102 and Retalac® mixed with four different types of precipitated nano-silica (SIPERNAT® D10, D17, 50 S and 500 LS), was assessed using two granular compaction devices: Densitap® and FT4® compaction cell. Our results show that the hydrophilicity of colloidal silica affects surface coverage, ranging from 6% to over 80%. Binary mixtures with hydrophobic additives, D10 and D17, generated smaller silica aggregates with a wider spread on the surface of host particles. For Retalac® conditioned at 20% RH, HR values changed from 1.30 (acceptable flow) to 1.17 (good flow). For Avicel® PH-102, conditioned at 60% RH, HR values changed from 1.22 (fair flow) to less than 1.10 (excellent flow).


Asunto(s)
Celulosa , Excipientes , Humedad , Tamaño de la Partícula , Polvos
5.
J Cardiovasc Magn Reson ; 23(1): 15, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33641670

RESUMEN

BACKGROUND: Circulatory efficiency reflects the ratio between total left ventricular work and the work required for maintaining cardiovascular circulation. The effect of severe aortic valve stenosis (AS) and aortic valve replacement (AVR) on left ventricular/circulatory mechanical power and efficiency is not yet fully understood. We aimed to quantify left ventricular (LV) efficiency in patients with severe AS before and after surgical AVR. METHODS: Circulatory efficiency was computed from cardiovascular magnetic resonance (CMR) imaging derived volumetric data, echocardiographic and clinical data in patients with severe AS (n = 41) before and 4 months after AVR and in age and sex-matched healthy subjects (n = 10). RESULTS: In patients with AS circulatory efficiency was significantly decreased compared to healthy subjects (9 ± 3% vs 12 ± 2%; p = 0.004). There were significant negative correlations between circulatory efficiency and LV myocardial mass (r = - 0.591, p < 0.001), myocardial fibrosis volume (r = - 0.427, p = 0.015), end systolic volume (r = - 0.609, p < 0.001) and NT-proBNP (r = - 0.444, p = 0.009) and significant positive correlation between circulatory efficiency and LV ejection fraction (r = 0.704, p < 0.001). After AVR, circulatory efficiency increased significantly in the total cohort (9 ± 3 vs 13 ± 5%; p < 0.001). However, in 10/41 (24%) patients, circulatory efficiency remained below 10% after AVR and, thus, did not restore to normal values. These patients also showed less reduction in myocardial fibrosis volume compared to patients with restored circulatory efficiency after AVR. CONCLUSION: In our cohort, circulatory efficiency is reduced in patients with severe AS. In 76% of cases, AVR leads to normalization of circulatory efficiency. However, in 24% of patients, circulatory efficiency remained below normal values even after successful AVR. In these patients also less regression of myocardial fibrosis volume was seen. Trial Registration clinicaltrials.gov NCT03172338, June 1, 2017, retrospectively registered.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Función Ventricular Izquierda , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Casos y Controles , Ecocardiografía Doppler , Femenino , Fibrosis , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Miocardio/patología , Recuperación de la Función , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Remodelación Ventricular
6.
Anaesthesia ; 75(8): 1039-1049, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32342498

RESUMEN

In patients with pre-operative anaemia undergoing cardiac surgery, combination treatment with intravenous iron, subcutaneous erythropoietin alpha, vitamin B12 and oral folic acid reduces allogeneic blood product transfusions. It is unclear if certain types of anaemia particularly benefit from this treatment. We performed a post-hoc analysis of anaemic patients from a randomised trial on the 'Effect of ultra-short-term treatment of patients with iron deficiency or anaemia undergoing cardiac surgery'. We used linear regression analyses to examine the efficacy of a combination anaemia treatment compared with placebo on the following deficiencies, each representing a part of the combination treatment: ferritin and transferrin saturation; endogenous erythropoietin; holotranscobalamine; and folic acid in erythrocytes. Efficacy was defined as change in reticulocyte count from baseline to the first, third and fifth postoperative days and represented erythropoietic activity in the immediate peri-operative recovery phase. In all 253 anaemic patients, iron deficiency was the most common cause of anaemia. Treatment significantly increased reticulocyte count in all regression analyses on postoperative days 1, 3 and 5 (all p < 0.001). Baseline ferritin and endogenous erythropoietin were negatively associated with change in reticulocyte count on postoperative day 5, with an unstandardised regression coefficient B of -0.08 (95%CI -0.14 to -0.02) and -0.14 (95%CI -0.23 to -0.06), respectively. Quadruple anaemia treatment was effective regardless of the cause of anaemia and its effect manifested early in the peri-operative recovery phase. The more pronounced a deficiency was, the stronger the subsequent boost to erythropoiesis may have been.


Asunto(s)
Anemia/tratamiento farmacológico , Cuidados Preoperatorios/métodos , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Anemia Ferropénica/tratamiento farmacológico , Transfusión Sanguínea/estadística & datos numéricos , Procedimientos Quirúrgicos Cardíacos/métodos , Método Doble Ciego , Quimioterapia Combinada , Eritropoyetina/administración & dosificación , Eritropoyetina/uso terapéutico , Femenino , Ácido Fólico/administración & dosificación , Ácido Fólico/uso terapéutico , Hematínicos/administración & dosificación , Hematínicos/uso terapéutico , Humanos , Hierro/administración & dosificación , Hierro/uso terapéutico , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Recuento de Reticulocitos , Vitamina B 12/administración & dosificación , Vitamina B 12/uso terapéutico , Complejo Vitamínico B/administración & dosificación , Complejo Vitamínico B/uso terapéutico
7.
Chirurg ; 91(3): 235-239, 2020 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-32144448

RESUMEN

Less than 10 years ago a breakthrough was made in the world of computer science and artificial intelligence (AI) with the application of deep neural networks, which initially found little attention in medicine. In 2017 the first high-ranking publications on the medical application of AI were published. The potential of AI became known to many both in clinical medicine as well as in clinical and biomedical research. At the end of 2019 a phase of upheaval is occurring: first concepts for regulatory procedures have appeared, a large number of start-ups but also established companies are endeavoring to introduce AI-based medical devices into the market. This article discusses the basic principles for understanding AI-based medical devices as well as an overview of current AI-based solutions specific to cardiac surgery.


Asunto(s)
Investigación Biomédica , Procedimientos Quirúrgicos Cardíacos , Inteligencia Artificial , Redes Neurales de la Computación
8.
Eur Heart J ; 41(2): 200-203, 2020 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-31909425
9.
Sci Rep ; 9(1): 3327, 2019 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-30804387

RESUMEN

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

11.
Sci Rep ; 7(1): 9897, 2017 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-28851875

RESUMEN

Optimizing treatment planning is essential for advances in patient care and outcomes. Precisely tailored therapy for each patient remains a yearned-for goal. Cardiovascular modelling has the potential to simulate and predict the functional response before the actual intervention is performed. The objective of this study was to proof the validity of model-based prediction of haemodynamic outcome after aortic valve replacement. In a prospective study design virtual (model-based) treatment of the valve and the surrounding vasculature were performed alongside the actual surgical procedure (control group). The resulting predictions of anatomic and haemodynamic outcome based on information from magnetic resonance imaging before the procedure were compared to post-operative imaging assessment of the surgical control group in ten patients. Predicted vs. post-operative peak velocities across the valve were comparable (2.97 ± 1.12 vs. 2.68 ± 0.67 m/s; p = 0.362). In wall shear stress (17.3 ± 12.3 Pa vs. 16.7 ± 16.84 Pa; p = 0.803) and secondary flow degree (0.44 ± 0.32 vs. 0.49 ± 0.23; p = 0.277) significant linear correlations (p < 0.001) were found between predicted and post-operative outcomes. Between groups blood flow patterns showed good agreement (helicity p = 0.852, vorticity p = 0.185, eccentricity p = 0.333). Model-based therapy planning is able to accurately predict post-operative haemodynamics after aortic valve replacement. These validated virtual treatment procedures open up promising opportunities for individually targeted interventions.

12.
Int J Cardiol ; 241: 326-329, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28499667

RESUMEN

BACKGROUND: Stanford acute type A aortic dissection (ATAAD) is a potentially lethal condition. Epidemiology studies show a statistical incidence in Europe of approximately 2-16 cases/100,000 inhabitants/year. In Germany, the estimated incidence (here subsumed under "thoracic aortic dissection" with 4.63 cases/100,000 inhabitants/year) is mainly extracted from medical death certificates by the German Federal Statistical Office. The prehospital incidence of ATAAD deaths is largely unknown. Since patients often die in the pre-hospital setting, the incidence of ATAAD is therefore likely to be higher than current estimates. MATERIAL AND METHODS: For the period from 2010 to 2014, we retrospectively analyzed all in-hospital ATAAD data from two of the largest cardiac surgical centers that treat ATAAD in the Berlin-Brandenburg region. In addition, autopsy reports of all forensic medicine institutes and of one large pathological provider in the region were analyzed to identify additional non-hospitalized ATAAD patients. Based on these findings, the regional incidence of ATAAD was calculated. RESULTS: In addition to in-hospital ATAAD patients (n=405), we identified additional 145 lethal ATAAD cases among 14,201 autopsy reports. The total of 550 ATAAD cases led to an estimated incidence of 11.9 cases/100,000 inhabitants/year for the whole Berlin-Brandenburg region. Arterial hypertension, pre-existing aortic dilatation, and hereditary connective tissue disorder were found in, respectively, 62.7%, 10%, and 1.8% of patients. CONCLUSION: ATAAD is more frequent than previously reported. Our results show that when patients who die outside of cardiac surgery centers are included, the incidence of ATAAD significantly exceeds the rate reported by the Federal Statistical Office.


Asunto(s)
Aorta/patología , Aneurisma de la Aorta/epidemiología , Aneurisma de la Aorta/patología , Disección Aórtica/epidemiología , Disección Aórtica/patología , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/mortalidad , Aneurisma de la Aorta/mortalidad , Berlin/epidemiología , Femenino , Alemania/epidemiología , Hospitalización/tendencias , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
13.
Chem Commun (Camb) ; 52(97): 14023-14026, 2016 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-27853758

RESUMEN

Self-assembly of a molecule with many distinct conformational states, resulting in eight possible pairs of surface enantiomers, is investigated on a Au(111) surface under UHV conditions. The complex molecule is equipped with alkyl and carboxyl moieties to promote controlled self-assembly of lamellae structures. From statistical analysis of Scanning Tunnelling Microscopy (STM) data we observe a clear selection of specific conformational states after self-assembly. Using Density Functional Theory (DFT) calculations we rationalise how this selection is correlated to the orientation of the alkyl moieties in mirror-image domains of the lamellae structures, leading to selection of three out of the eight possible enantiomeric pairs.

16.
Eur Heart J ; 36(41): 2779, 2015 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26129948

RESUMEN

Corrigendum to: 2014 ESC Guidelines on the diagnosis and treatment of aortic diseases [Eur Heart Journal (2014) 35, 2873­2926,doi:10.1093/eurheartj/ehu281]. In Table 3, the radiation for MRI is "0" and not "-". The corrected table is shown below.

17.
Herz ; 40(2): 231-9, 2015 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-25822421

RESUMEN

Mechanical circulatory support nowadays represents an important option in the treatment of patients with advanced heart insufficiency. Once developed as a bridging to heart transplantation, it is now a valuable option for permanent support in patients for whom a heart transplantation is not possible due to contraindications or a lack of available organs. Furthermore, it can be used as a bridging to myocardial recovery and explantation. The number of implantations of left ventricular assist devices (LVAD) has clearly increased in recent years and approximately one half of these implantations is already carried out in centers not specialized in transplantations. This development necessitates that every practicing physician is aware of the basic principles of mechanical circulatory support and with the possible complications. This article gives a summary of the current state of the technology and treatment of patients with long-term VADs.


Asunto(s)
Insuficiencia Cardíaca/prevención & control , Corazón Auxiliar , Bombas de Infusión Implantables , Cuidado Terminal/métodos , Disfunción Ventricular Izquierda/terapia , Enfermedad Crónica , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Humanos , Diseño de Prótesis , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico
18.
Transplant Proc ; 46(5): 1463-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24935314

RESUMEN

INTRODUCTION: There are conflicting reports on the posttransplantation morbidity and mortality of patients listed urgently and/or supported by a ventricular assist device (VAD). The aim of this study was to analyze the outcomes with regard to pretransplantation condition (elective, urgent, VAD). METHODS: All adult recipients between January 1, 2005, and October 31, 2012, were included. Demographics; preoperative, operative, and postoperative data; outpatient follow-up; and donor characteristics were collected and analyzed. RESULTS: Of a total of 74 patients, 19 were listed urgently, 20 had a Berlin Heart EXCOR BVAD (biventricular assist device) (Berlin Heart, Berlin, Germany) (8 urgent), 7 had a Berlin Heart INCOR left VAD (Berlin Heart, Berlin, Germany) (2 urgent), and 2 had a HeartWare left VAD (HeartWare International, Framingham, Mass, USA) (none urgent). Mean age was 52 ± 12years. The overall 30-day, 1-year, and 3-year survival was 90% ± 3%, 79% ± 5%, and 66% ± 7%. There was no difference in survival when comparing urgently listed (95% ± 5%, 84% ± 8%, 74% ± 12%) and elective patients (89% ± 4%, 77% ± 6%, 63% ± 8%; P = .4), and VAD patients (86% ± 6%, 76% ± 8%, 63% ± 11%) and those without mechanical support (93% ± 4%, 81% ± 6%, 69% ± 9%; P = .6). In-hospital outcomes and long-term complications were also comparable. CONCLUSIONS: Our series suggests that urgent patients and patients on a VAD have a posttransplantation outcome comparable to elective patients and patients without a VAD. These data support the effectiveness of the current practice of listing for heart transplantation.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Índice de Severidad de la Enfermedad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Resultado del Tratamiento
19.
Eur J Emerg Med ; 21(2): 105-11, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23751288

RESUMEN

OBJECTIVE: The use of emergency medical services increases with the age of patients. Some care providers hold on to the prejudice that these alarms are unnecessary or of a lower importance. We assessed the relation of age and age-dependent emergency characteristics, taking into consideration the ratings of emergency physicians on whether or not emergency cases were considered truly in need of emergency physician attendance. METHODS: Emergency physicians dispatched by the Berlin Fire Department evaluated for each case the necessity of emergency physician attendance. Case characteristics such as the day of the week and location of the emergency as well as patient characteristics such as age, sex, prior status, and care dependency were recorded. In addition, whether or not the physician accompanied the patient to the hospital was recorded as a parameter for emergency severity. Analysis was performed using multiple logistic regression modeling. RESULTS: During the 6-month prospective study period, 2702 cases were evaluated. Emergency medical services are used more frequently by older individuals, especially octogenarians. Emergency cases in older individuals were significantly more often rated as in need of emergency physician attendance; however, the rate of patients accompanied by the emergency physician to the hospital did not differ between the age groups. The age of patients, the primary diagnosis, the day and location of the emergency, and the presence of pre-existing dementia showed a significant impact on the necessity of physician-attended emergency missions. CONCLUSION: Despite common prejudices, emergency cases in elder patients are rated more often as in need of emergency physician attendance compared with those involving younger patients.


Asunto(s)
Enfermedad Crónica/terapia , Servicios Médicos de Urgencia/organización & administración , Servicios de Salud para Ancianos/organización & administración , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Urgencias Médicas , Servicios Médicos de Urgencia/normas , Alemania , Servicios de Salud para Ancianos/normas , Humanos , Lactante , Persona de Mediana Edad , Estudios Prospectivos , Calidad de la Atención de Salud , Encuestas y Cuestionarios , Adulto Joven
20.
Perfusion ; 28(4): 292-7, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23404056

RESUMEN

BACKGROUND: In order to reduce the negative effects of extracorporeal circulation (ECC), the perfusion system and management were optimized at our institution. The goals of optimization were a reduction in the priming volume, in the foreign surface area and in microbubble activity, as well as optimization of suction blood management. METHODS: Sixty patients were included in this retrospective study. Patients were assigned to two groups, with regard to the use of an optimized perfusion system (OPS-group, n=30) and a standard perfusion system (SPS-group, n=30). All patients underwent elective procedures. RESULTS: There were no significant differences with respect to patient demographics and operation time. ECC time and cross-clamp time were significantly longer in the OPS group. Statistically significant differences in outcome between the two groups were seen with regard to the following variables: effective priming volume (OPS: 775±447ml; SPS: 1610±0ml; p<0.0001), hemoglobin drop after the start of ECC (OPS: 2.7±1.2g/dl; SPS: 4.2±0.8g/dl; p<0.0001), c-reactive protein on postoperative day 2 (OPS: 121.0±59.4 U/l; SPS: 164.0±50.2 U/l; p=0.003). With regard to the use of blood transfusions, a 33% reduction in the overall amount of transfused units was seen. The rate of patients without transfusions during the entire hospital stay increased from 37% (SPS) to 53% (OPS). The mean transfused red blood cell units per patient was lower in the OPS-group (1.6±2.4 units) than in the SPS-group (2.3±3.5 units). CONCLUSION: With the described optimized perfusion system, a significantly lower priming volume, leading to less hemodilution after the onset of CPB, was achieved. The amount of blood transfusions and the inflammatory response were reduced.


Asunto(s)
Puente Cardiopulmonar/métodos , Circulación Extracorporea/métodos , Adulto , Anciano , Anciano de 80 o más Años , Transfusión Sanguínea , Proteína C-Reactiva/análisis , Puente Cardiopulmonar/instrumentación , Circulación Extracorporea/instrumentación , Femenino , Hemoglobinas/análisis , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA