Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Biomed Opt Express ; 14(7): 3610-3621, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37497492

RESUMEN

Preoperative assessment of liver function reserve (LFR) is essential for determining the extent of liver resection and predicting the prognosis of patients with liver disease. In this paper, we present a real-time, handheld photoacoustic imaging (PAI) system-based noninvasive approach for rapid LFR assessment. A linear-array ultrasound transducer was sealed in a housing filled with water; its front end was covered with a plastic wrap. This PAI system was first implemented on phantoms to confirm that the photoacoustic (PA) intensity of indocyanine green (ICG) in blood reflects the concentration of ICG in blood. In vivo studies on normal rabbits and rabbits with liver fibrosis were carried out by recording the dynamic PA signal of ICG in their jugular veins. By analyzing the PA intensity-time curve, a clear difference was identified in the pharmacokinetic behavior of ICG between the two groups. In normal rabbits, the mean ICG clearance rate obtained by PAI at 15 min after administration (PAI-R15) was below 21.6%, whereas in rabbits with liver fibrosis, PAI-R15 exceeded 62.0% because of poor liver metabolism. The effectiveness of the proposed method was further validated by the conventional ICG clearance test and pathological examination. Our findings suggest that PAI is a rapid, noninvasive, and convenient method for LFR assessment and has immense potential for assisting clinicians in diagnosing and managing patients with liver disease.

2.
World J Surg ; 45(7): 2108-2115, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33770240

RESUMEN

OBJECTIVES: To evaluate the clinical impact and technical feasibility of augmented reality laparoscopic navigation (ARLN) system in laparoscopic splenectomy for massive splenomegaly. METHODS: The clinical data of 17 consecutive patients who underwent laparoscopic splenectomy using ARLN (ARLN group) and 26 patients without ARLN guidance (Non-ARLN group) between January 2018 and April 2020 were enrolled. Propensity score matching (PSM) analysis was performed between the patients with and without ARLN guidance at a ratio of 1:1. RESULTS: Mean intraoperative blood loss was significantly lower in the ARLN-group than in the Non-ARLN group (306.6 ml vs. 462.6 ml, p = 0.047). All the patients in the ARLN-group achieved successful splenic artery dissection, while surgical success was achieved in 12 patients in the Non-ARLN group (p = 0.044). Postoperative hospital stay was significantly longer in the Non-ARLN group (3.8 days vs. 4.5 days, p = 0.040). CONCLUSIONS: ARLN can provide feasible and accurate intraoperative image guidance, and it could be helpful in the performance of laparoscopic splenectomy for massive splenomegaly.


Asunto(s)
Realidad Aumentada , Laparoscopía , Humanos , Estudios Retrospectivos , Esplenectomía , Esplenomegalia/cirugía , Resultado del Tratamiento
4.
J Surg Oncol ; 122(8): 1580-1586, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32895951

RESUMEN

OBJECTIVE: The aim of this study was to present a novel bile-duct obstructed area imaging (BOAI) and to investigate the feasibility and accuracy of this method in guiding hepatectomy for intrahepatic cholangiocarcinoma (ICC) with intrahepatic biliary obstruction. METHODS: From May 2017 to October 2019, eligible patients who underwent hepatectomy guided by BOAI were enrolled. Perioperative outcomes and operative data were analyzed. To assess the feasibility of BOAI and Glissonean pedicle approach, demarcations based on them were compared. To verify the accuracy of BOAI staining of the target territory, simple linear regression analysis, and intraclass correlation coefficient were used to examine the relationship between predicted resected liver volume (PRLV) and actual resected liver volume (ARLV). RESULTS: BOAI staining achieved valid demarcation in 15 (93.8%) of 16 patients, whereas the ischemic line achieved valid demarcation in only nine patients (57.3%; p = .017). ARLV and PRLV had a strong positive correlation (PRLV = 60.06 + 0.925 × ARLV; R = .945; p = .000). Meanwhile, ARLV (intraclass correlation coefficient = .971) achieved an excellent agreement with PRLV (p < .001). CONCLUSIONS: The novel BOAI staining method can provide valid, feasible, and accurate demarcation line and may be an effective method in the surgical treatment of intrahepatic biliary obstruction.


Asunto(s)
Neoplasias de los Conductos Biliares/cirugía , Colangiocarcinoma/cirugía , Colestasis/cirugía , Colorantes/química , Diagnóstico por Imagen/métodos , Hepatectomía/métodos , Cirugía Asistida por Computador/métodos , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Neoplasias de los Conductos Biliares/patología , Colangiocarcinoma/diagnóstico por imagen , Colangiocarcinoma/patología , Colestasis/diagnóstico por imagen , Colestasis/patología , Estudios de Factibilidad , Femenino , Fluorescencia , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
5.
Biomaterials ; 195: 13-22, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30599289

RESUMEN

Pancreatic cancer is one of the most lethal malignancies worldwide. The existing therapeutic regimen in the clinic for advanced inoperable carcinomas are far from satisfactory, thus it is urgent to seek more effective anticancer strategies. In the pursuit of novel, more effective interventions, photothermal therapy (PTT) based on nanomaterials has attracted increased attention. Recent advances in related fields have catalyzed the generation of novel nanoprobes, such as organic dyes, metal nanoparticles. However, organic dyes are poorly stable and easy to quench while metal nanoparticles with potential metal toxicity are difficult to degrade, both of which have low light-to-heat conversion efficiency, broad spectrum of anti-tumor effects, and lack of tumor targeting specificity. Single-walled carbon nanotubes (SWNTs) can remedy the above inadequacies. Herein, we report our water-soluble, bio-stable and low-toxicity SWNTs with excellent photothermal conversion efficiency. Specific modifications can enable visualization of the aggregate characteristics of SWNTs at the macroscopic or microscopic level in tumors. The dye-conjugated SWNTs bound with targeting antibodies that can induce them specifically targeting to pancreatic tumors for purposes of performing dyes imaging-guided cytotoxic PTT. PTT using this method achieves precise and excellent curative effects with minimal adverse effects, thus providing a promising strategy for anticancer therapy.


Asunto(s)
Nanotubos de Carbono/química , Imagen Óptica/métodos , Neoplasias Pancreáticas/terapia , Fototerapia/métodos , Receptor IGF Tipo 1/química , Animales , Humanos
6.
J Surg Oncol ; 118(7): 1081-1087, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30293249

RESUMEN

BACKGROUND: The aim of this study was to assess the accuracy of actual resected liver volume (ARLV) in anatomical liver resections (ALRs) guided by 3-dimensional parenchymal staining using fusion indocyanine green fluorescence imaging (IGFI). METHODS: Patients eligible for hepatic resection were enrolled in the current study from January 2016 to November 2017. All patients underwent surgery planning based on Medical Image Three-Dimensional Visualization System (MI-3DVS) before the operation, in which predicted resected liver volumes (PRLVs) were calculated. Under 3-dimensional guidance by fusion IGFI, ALRs were performed and ARLVs were measured. Simple linear regression, intra-class correlation coefficient (ICC) and Bland-Altman analysis were used to evaluate the relationship and agreement between PRLV and ARLV. RESULTS: Of the 27 patients who achieved valid demarcation by fusion IGFI, 12 (44.4%) received hemihepatectomy, while 10 (37.0%) and five (18.5%) underwent sectionectomy and segmentectomy, respectively. The relationship and agreement between PRLV (481.37 ± 189.47 cm³) and ARLV (450.57 ± 205.19 cm³) were then evaluated. The simple regression equation obtained was PRLV = 0.874 × ARLV + 87.75 (R = 0.946; P = 0.000). Meanwhile, ARLV (ICC = 0.943) achieved an excellent agreement with PRLV ( P < 0.001); 25 of 27 dots were in the range of 95% confidence interval in Bland-Altman analysis. CONCLUSIONS: In the study, these findings validated the consistency between PRLV calculated by MI-3DVS and ARLV guided by fusion IGFI, which proved that IGFI can accurately guide anatomical hepatectomy. Generally, fusion IGFI can provide a valid, feasible and accurate demarcation line, which can confer precision to hepatic resection.


Asunto(s)
Hepatectomía/métodos , Imagenología Tridimensional , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Hígado/diagnóstico por imagen , Imagen Óptica , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/secundario , Carcinoma Hepatocelular/cirugía , Colangiocarcinoma/diagnóstico por imagen , Colangiocarcinoma/secundario , Colangiocarcinoma/cirugía , Femenino , Colorantes Fluorescentes , Humanos , Verde de Indocianina , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Estudios Prospectivos , Coloración y Etiquetado , Tomografía Computarizada por Rayos X
7.
J Laparoendosc Adv Surg Tech A ; 28(7): 794-798, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29620955

RESUMEN

INTRODUCTION: To study the anatomical features and classification of the angle between the right gastroepiploic vein (RGEV) and superior mesenteric vein/portal vein (SMV/PV) and to guide the catheterization of intraportal infusion chemotherapy through RGEV and reduce surgical complications. PATIENTS AND METHODS: A retrospective three-dimensional (3D) computed tomography study was undertaken on 200 consecutive subjects with or without hepatic malignant tumors with a dedicated workstation 3D-MIA (the improved MI-3DVS workstation) developed by ourselves to determine the prevalence of surgically significant angle between RGEV and SMV/PV anatomic variations and its classification. RESULTS: The mean value of the angles between the end of RGEV and SMV/PV (AERS/P) (200 cases) was 84.2° ± 23.8 (31.4°-151.5°): 40.6° ± 92.3 (-177.9° to 178.0°) (sagittal angle), 81.7° ± 29.8 (-79.3° to 160.7°) (coronal angle), and 10.5° ± 94.3 (-178.7° to 175.8°) (horizontal angle). The mean value of the angles between the right bend of RGEV and SMV/PV (ARRS/P) (168 cases) was 104.8° ± 26.1 (20.5°-159.7°):49.3° ± 117.8 (-175.3° to 179.5°) (sagittal angle), 103.5° ± 37.7 (-178.8° to 168.9°) (coronal angle), and 12.6° ± 102.8 (-179.9° to 179.2°) (horizontal angle). The AERS/P were classified into large angle group (32 cases, 16%), middle angle group (113 cases, 56.5%), and small angle group (55 cases, 27.5%) based on angle variations and risks of catheterization. CONCLUSIONS: Precognition of the variations of AERS/P and ARRS/P before surgery is useful during chemotherapy pump catheterizing through RGEV in reduction of surgical complications by modulating the angle and direction of RGEV running into SMV/PV properly.


Asunto(s)
Cateterismo , Quimioterapia del Cáncer por Perfusión Regional , Venas Mesentéricas/anatomía & histología , Vena Porta/anatomía & histología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional , Masculino , Venas Mesentéricas/diagnóstico por imagen , Persona de Mediana Edad , Vena Porta/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
8.
Nan Fang Yi Ke Da Xue Xue Bao ; 37(8): 1131-1135, 2017 Aug 20.
Artículo en Chino | MEDLINE | ID: mdl-28801298

RESUMEN

OBJECTIVE: To study the value of 3D visualization technique in breast-preserving surgery for breast cancer with immediate breast reconstruction using laparoscopically harvested pedicled latissimus dorsi muscle flap. METHODS: From January, 2015 to May, 2016, 30 patients with breast cancer underwent breast-preserving surgery with immediate breast reconstruction using pedicled latissimus dorsi muscle flap. The CT data of the arterial phase and venous phase were collected preoperatively and imported into the self-developed medical image 3D visualization system for image segmentation and 3D reconstruction. The 3D models were imported into the simulation surgery platform for virtual surgery to prepare for subsequent surgeries. The cosmetic outcomes of the patients were evaluated 6 months after the surgery. Another 18 patients with breast cancer who underwent laparoscopic latissimus dorsi muscle breast reconstruction without using 3D visualization technique from January to December, 2014 served as the control group. The data of the operative time, intraoperative blood loss and postoperative appearance of the breasts were analyzed. RESULTS: The reconstructed 3D model clearly displayed the anatomical structures of the breast, armpit, latissimus dorsi muscle and vessels and their anatomical relationship in all the 30 cases. Immediate breast reconstruction was performed successfully in all the cases with median operation time of 226 min (range, 210 to 420 min), a median blood loss of 95 mL (range, 73 to 132 mL). Evaluation of the appearance of the breast showed excellent results in 22 cases, good appearance in 6 cases and acceptable appearance in 2 cases. In the control group, the median operation time was 283 min (range, 256 to 313 min) and the median blood loss was 107 mL (range, 79 to 147 mL) with excellent appearance of the breasts in 10 cases, good appearance in 4 cases and acceptable appearance in 4 cases. CONCLUSION: 3D reconstruction technique can clearly display the morphology of the latissimus dorsi and the thoracic dorsal artery, allows calculation of the volume of the breast and the latissimus dorsi, and helps in defining the scope of resection of the latissimus dorsi to avoid injuries of the pedicled vessels. This technique also helps to shorten the operation time, reduce intraoperative bleeding, and improve the appearance of the reconstructed breast using pedicled latissimus dorsi muscle flap.

9.
Biochem Biophys Res Commun ; 487(1): 122-127, 2017 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-28408212

RESUMEN

The aim of this study was to evaluate the inhibiting effect of apigenin on liver cancer in vivo based on the optical molecular imaging method. Subcutaneous liver tumor models were established using respective 1 × 106 firefly luciferase (fLuc) and green fluorescent protein (GFP) labeled human hepatocellular carcinoma cells (HepG2-fLuc and HepG2-GFP cells) in 20 BALB/c nude mice which were randomly divided into two groups, 10 in each group. After the tumor cells were implanted 15 days, apigenin was administered through intraperitoneal injection in group B, the other ten mice as control group A. Bioluminescence imaging (BLI) and fluorescence molecular imaging (FMI) were carried out for the follow-up of subcutaneous tumor model. As time goes on, intensity and distribution of bioluminescence and fluorescence of tumours increased gradually with the growth of tumours little by little. The whole process of observation was in accordance with known activities of HCC in the human liver. The tumor volume and tumor weight were significant lower in group B than in group A (p < 0.05), Subcutaneous tumours in the apigenin treatment group B based on BLI and FMI were significantly inhibited compared to the control group A (p < 0.05). Apigenin could be expected as a new drug to treat hepatocellular carcinoma. Optical molecular imaging technology enabled the non-invasive and reliable assessment of anti-tumor drug efficacy on liver cancer.


Asunto(s)
Apigenina/administración & dosificación , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/patología , Imagen Molecular/métodos , Animales , Antineoplásicos/administración & dosificación , Línea Celular Tumoral , Relación Dosis-Respuesta a Droga , Ensayos de Selección de Medicamentos Antitumorales/métodos , Humanos , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Microscopía Fluorescente/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
10.
Clin Imaging ; 43: 9-14, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28153667

RESUMEN

OBJECTIVE: To confirm the histological grade of hepatocellular carcinoma (HCC) by gadoxetic acid-enhanced MRI. METHODS: Ninety-five HCC patients underwent gadoxetic acid-enhanced MRI before surgical intervention. The correlations among the signal absolute enhancement, contrast enhancement ratio (CER) and tumor histological grade were analyzed. RESULTS: The correlation between CER of tumor-to-liver and the grades of tumor differentiation is the most significant negative. The k-value for the CER of tumor-to-liver and histopathologic analysis is 0.62, which gives evidence of good agreement. CONCLUSION: The quantitative analysis of gadoxetic acid-enhanced MRI can predict the histological grades of small HCCs.


Asunto(s)
Carcinoma Hepatocelular/patología , Medios de Contraste , Gadolinio DTPA , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Clasificación del Tumor , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
11.
Nan Fang Yi Ke Da Xue Xue Bao ; 36(8): 1129-33, 2016 Aug 20.
Artículo en Chino | MEDLINE | ID: mdl-27578585

RESUMEN

OBJECTIVE: To study the clinical value of digital 3D technique combined with nanocarbon-aided navigation in endoscopic sentinel lymph node biopsy for breast cancer. METHODS: Thirty-nine female patients with stage I/II breast cancer admitted in our hospital between September 2014 and September 2015 were recruited. CT lymphography data of the patients were segmented to reconstruct digital 3D models, which were imported into FreeForm Modeling Surgical System Platform for visual simulation surgery before operation. Endoscopic sentinel lymph node biopsy and endoscopic axillary lymph node dissection were then carried out, and the accuracy and clinical value of digital 3D technique in endoscopic sentinel lymph node biopsy were analyzed. RESULTS: s The 3D models faithfully represented the surgical anatomy of the patients and clearly displayed the 3D relationship among the sentinel lymph nodes, axillary lymph nodes, axillary vein, pectoralis major, pectoralis minor muscle and latissimus dorsi. In the biopsy, the detection rate of sentinel lymph nodes was 100% in the patients with a coincidence rate of 87.18% (34/39), a sensitivity of 91.67% (11/12), and a false negative rate of 8.33% (1/12). Complications such as limb pain, swelling, wound infection, and subcutaneouseroma were not found in these patients 6 months after the operation. CONCLUSION: Endoscopic sentinel lymph node biopsy assisted by digital 3D technique and nanocarbon-aided navigation allows a high detection rate of sentinel lymph nodes with a high sensitivity and a low false negative rate and can serve as a new method for sentinel lymph node biopsy for breast cancer.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Endoscopía , Imagenología Tridimensional , Biopsia del Ganglio Linfático Centinela , Ganglio Linfático Centinela/patología , Axila , Femenino , Humanos , Escisión del Ganglio Linfático , Metástasis Linfática , Nanopartículas
12.
Biomed Res Int ; 2016: 8931732, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27294142

RESUMEN

Background. Treatment selection for small hepatocellular carcinoma (sHCC) is controversial. We aimed to compare the outcomes of medical imaging three-dimensional visualization system (MI-3DVS) guided surgical resection (SR) and ultrasonography guided radiofrequency ablation (RFA) for sHCC. Methods. In total, 194 patients who underwent SR or RFA in our hospital between January 2006 and May 2010 were retrospectively enrolled. Overall survival (OS), recurrence-free survival (RFS), and postoperative complications were compared. Cox regression was used to estimate the benefits of MI-3DVS-guided SR on OS and RFS. Results. Ninety-two patients underwent SR and 102 underwent RFA. The SR group experienced more complications (41.3% versus 19.6%) and longer hospital stay (18.04 ± 7.11 versus 13.06 ± 5.59) (both p < 0.05). The 1-, 2-, 3-, 4-, and 5-year OS was 96.7%, 95.7%, 93.5%, 83.5%, and 61.1% in the SR group and 95.0%, 88.1%, 72.7%, 56.9%, and 39.5% in the RFA group. Corresponding RFS was 95.7%, 94.6%, 84.7%, 59.8%, and 40.2% in SR group and 91.2%, 80.3%, 60.5%, 32.3%, and 22.3% in RFA group. The 5-year OS and RFS were higher in SR group (both p < 0.001). Interestingly, there was no significance in OS and RFS among subgroups aged >60 years. Independent predictors of OS and RFS, respectively, were intervention (HR, 2.769 and 1.933), tumor number (HR, 5.128 and 3.903), and serum alpha-fetoprotein (AFP) (HR, 1.871 and 1.474) (all p < 0.05). Conclusions. MI-3DVS based hepatectomy should be considered primary treatment while RFA can be treated as alternative therapy for older patients. Intervention, tumor number, and AFP are independent predictors for both survival and recurrence.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter/métodos , Hepatectomía/métodos , Neoplasias Hepáticas , Adulto , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Tasa de Supervivencia
13.
World J Surg ; 40(6): 1467-76, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26796886

RESUMEN

BACKGROUND: A majority of factors associated with the occurrence of clinical relevant postoperative pancreatic fistula (CR-POPF) after pancreaticoduodenectomy (PD) can only be identified intra- or postoperatively. There are no reports for assessing the morphological features of pancreatic stump and analyzing its influence on CR-POPF risk after PD preoperatively. METHOD: A total of 90 patients underwent PD between April 2012 and May 2014 in our hospital were included. Preoperative computed tomographic (CT) images were imported into the Medical Image Three-Dimensional Visualization System (MI-3DVS) for acquiring the morphological features of pancreatic stump. The demographics, laboratory test and morphological features of pancreatic stump were recorded prospectively. The clinical course was evaluated focusing on the occurrence of pancreatic fistula as defined by the International Study Group on Pancreatic Fistula (ISGPF). Logistic regression analysis was used to identify independent predictors of CR-POPF. RESULTS: CR-POPF occurred in 18 patients (14 grade B, 4 grade C). In univariate analysis, male gender (P = 0.026), body mass index (BMI) ≥ 25.3 kg/m(2) (P = 0.002), main pancreas duct diameter (MPDD) < 3.1 mm (P = 0.005), remnant pancreatic parenchymal volume (RPPV) > 27.8 mL (P < 0.001), and area of cut surface (AOCS) > 222.3 mm(2) (P < 0.001) were associated with an increased risk of CR-POPF. In multivariate analysis, BMI ≥ 25.3 kg/m(2) (OR 12.238, 95 % CI 1.822-82.215, P = 0.010) and RPPV > 27.8 mL (OR 12.907, 95 % CI 1.602-104.004, P = 0.016) were the only independent risk factors associated with CR-POPF. A cut-off value of 27.8 mL for RPPV established based on the receiver operating characteristic (ROC) curve, which was the strongest single predictive factor for CR-POPF, with a sensitivity and specificity of 77.8 and 86.1 %, respectively. The area under the ROC curve of RPPV was 0.770 (95 % CI 0.629-0.911, P < 0.001). CONCLUSIONS: Our study demonstrated that CR-POPF is correlated with BMI and RRPV. MI-3DVS provides us a novel and convenient method for measuring the RPPV. Preoperative acquisition of RPPV and BMI may help the surgeons in fitting postoperative management to patient's individual risk after PD.


Asunto(s)
Índice de Masa Corporal , Páncreas/diagnóstico por imagen , Páncreas/cirugía , Fístula Pancreática/etiología , Pancreaticoduodenectomía/efectos adversos , Complicaciones Posoperatorias/etiología , Anciano , Área Bajo la Curva , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Conductos Pancreáticos/patología , Curva ROC , Factores de Riesgo , Tomografía Computarizada por Rayos X
14.
J Surg Res ; 195(1): 105-12, 2015 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-25680473

RESUMEN

BACKGROUND: Hepatolithiasis is challenging for surgeons to treat especially in patients with previous hepatobiliary surgery. The aim of the study was to report our experience of rigid choledochoscopy lithotripsy in targeted treatment of hepatolithiasis under the guidance of a medical image three-dimensional visualization system, which we developed and patented (software copyright no: 2008SR18 798) by comparing it with hepatectomy without a three-dimensional (3D) reconstruction technique. METHODS: Between December 2007 and March 2013, 64 patients underwent rigid choledochoscopy lithotripsy based on 3D visualization technology conducted by a medical image three-dimensional visualization system for hepatolithiasis (group A). During the same period, 61 patients with hepatolithiasis were selected for hepatectomy (group B). Comparative analysis was made of demographic and perioperative characteristics of the two groups. RESULTS: 3D visualization was instructive for surgeons on how the stones were distributed and what the spatial relationship was between stones and the intrahepatic vascular system. Compared with patients in group B, those in group A had a significantly lower intermediate residual stone rate, a faster operating time, a lower intraoperative blood loss and intraoperative blood transfusion, a shorter postoperative hospital stay, less postoperative complications, and more liver function reserved (P < 0.05 for all). Final residual stone rate, stone recurrence rate, and recurrent cholangitis rate were similar. CONCLUSIONS: 3D visualization technology provides an important reference and a valuable planning for rigid choledochoscopy lithotripsy, which is a feasible and effective method for management of hepatolithiasis.


Asunto(s)
Imagenología Tridimensional , Litiasis/cirugía , Litotricia/métodos , Hepatopatías/cirugía , Cirugía Asistida por Computador/estadística & datos numéricos , Adulto , Anciano , Procedimientos Quirúrgicos del Sistema Digestivo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
J Am Coll Surg ; 220(1): 28-37, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25456781

RESUMEN

BACKGROUND: The aim of this retrospective study was to compare the outcomes of operations based on 3-dimensional (3D) operation planning with non 3D-assisted operations in the treatment of centrally located hepatocellular carcinoma. STUDY DESIGN: From April 2008 to March 2014, 116 patients with centrally located hepatocellular carcinoma received surgical treatment in our department. Among these cases, a total of 60 patients received resection with operation planning based on 3D reconstructions (group A); the remaining 56 received treatment with the aid of traditional imaging (group B). Three-dimensional surgical planning, including the classification system for centrally located hepatocellular carcinoma, was elaborated in the study. RESULTS: Compared with group B, group A was linked to shorter operation time (294.5 ± 61.9 minutes vs 324.3 ± 83.1 minutes; p = 0.028) and lower rate of hepatic inflow occlusion (51.7% vs 71.4%; p = 0.029). No differences were found in surgical methods, intraoperative blood transfusion, and intraoperative blood loss. The groups were similar in their rates of complications, except that group B was more liable to have Clavien Grade III to V complications (3.3% vs 14.3%; p = 0.048). In addition, a significant difference in ascites was found across the 2 cohorts (2 in group A and 8 in group B; p = 0.048), and the 2 groups also differed significantly in total bilirubin (23.2 ± 16.1 g/L vs 31.1 ± 24.1 g/L; p = 0.032) and albumin (29.3 ± 5.2 g/L vs 27.8 ± 7.9 g/L; p = 0.033). CONCLUSIONS: Compared with non 3D-assisted operations, the operation planning based on 3D reconstruction is a more effective and reasonable method in the treatment of centrally located hepatocellular carcinoma. In addition, the classification system may facilitate the 3D operation planning.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Hepatectomía/métodos , Imagenología Tridimensional , Neoplasias Hepáticas/cirugía , Tomografía Computarizada Multidetector , Cuidados Preoperatorios/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento
16.
Hepatogastroenterology ; 61(134): 1556-62, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25436342

RESUMEN

BACKGROUND: Treatment of complicated hepatolithiasis is complex and difficult. In this report, we present a novel approach to manage complicated hepatolithiasis using the rigid choledochoscope guided by CT-based 3D reconstruction technique with or without hepatectomy. METHODS: Between February 2012 to December 2013, 25 patients with complicated hepatolithiasis underwent rigid choledochoscope guided by CT-based 3D reconstruction technique combined with or without hepatectomy. 27 patients with complicated hepatolithiasis underwent a traditional operation (traditional method group) from June 2011 to January 2012. All operations were performed by the authors. RESULTS: The final stone clearance rate of the rigid choledochoscope group was 96%, whereas that of the traditional method group was 74.1% (P=0.032). There was no patient died of postoperative mortality in two groups. Moreover, the operative time in the traditional method group was significantly longer than that in the rigid choledochoscope group (P=0.010). Recurrent intrahepatic bile duct stones were not found during the follow-up period in the two groups. CONCLUSIONS: Operative rigid choledochoscope guided by CT-based 3D reconstruction technique combined with or without hepatectomy may be an effective and safe treatment for complicated hepatolithiasis.


Asunto(s)
Colelitiasis/cirugía , Endoscopios , Endoscopía , Imagenología Tridimensional , Hepatopatías/cirugía , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/métodos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Colelitiasis/complicaciones , Colelitiasis/diagnóstico por imagen , Endoscopía/instrumentación , Endoscopía/métodos , Diseño de Equipo , Femenino , Hepatectomía , Humanos , Hepatopatías/complicaciones , Hepatopatías/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Tempo Operativo , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Factores de Tiempo , Resultado del Tratamiento
17.
Int J Med Robot ; 10(4): 410-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24711375

RESUMEN

BACKGROUND: Our main aim was to evaluate the value of medical image three-dimensional visualization system (MI-3DVS) in pancreaticoduodenctomy patients with hepatic artery variance. METHODS: 114 patients who had undergone pancreatoduodenectomy were retrospectively summarized and analyzed. Clinical data of 64-slice multidetector CT angiography (64-MDCTA) scanning was introduced into MI-3DVS for procedural segmentation, registration and 3-dimensional (3D) reconstruction. The findings were compared with those found during the operation and by postoperative digital subtraction angiography (DSA) of coeliac artery. RESULTS: The 3D model demonstrated the origination and bifurcations of blood vessels, and the relationships among neoplasms, organs and blood vessels efficiently. About (14/114 cases, 12.3%) had variant. The sensitivity, specificity and accuracy of MI-3DVS in variant hepatic artery diagnosis were 100%. It assisted in preoperative procedural planning that was consistent with intraoperative findings. CONCLUSIONS: MI-3DVS can be applied for accurate diagnosis of hepatic artery variance. It also provides detailed preoperative guidance for individualized procedural planning.


Asunto(s)
Arteria Hepática/diagnóstico por imagen , Imagenología Tridimensional/métodos , Neoplasias Pancreáticas/cirugía , Pancreaticoduodenectomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Estudios Retrospectivos
18.
Pancreas ; 43(3): 389-95, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24622068

RESUMEN

OBJECTIVE: This study aimed to investigate the clinical significance of 3-dimensional (3D) reconstruction of peripancreatic vessels for patients with suspected pancreatic cancer (PC). METHODS: A total of 89 patients with PC were included; 60 patients randomly underwent computed tomographic angiography. Based on the findings of 3D reconstruction of peripancreatic vessels, the appropriate method for individualized tumor resection was determined. These patients were compared with 29 conventionally treated patients with PC. RESULTS: The rate of visualization was 100% for great vessels around the pancreas. The detection rates for anterior superior pancreaticoduodenal artery, posterior superior pancreaticoduodenal artery, anterior inferior pancreaticoduodenal artery, posterior inferior pancreaticoduodenal artery, dorsal pancreatic artery, superior marginal arterial branch of the pancreatic head, anterior superior pancreaticoduodenal vein, posterior superior pancreaticoduodenal vein, anterior inferior pancreaticoduodenal vein, and posterior inferior pancreaticoduodenal vein were 86.6%, 85.0%, 76.6%, 71.6%, 91.6%, 53.3%, 61.6%, 55.0%, 43.3%, and 51.6%, respectively. Forty-three patients who had undergone 3D reconstruction underwent surgery. Of the 29 conventionally treated patients, 19 underwent surgery. The operative time, blood loss, length of hospital stay, and complication incidence of the 43 patients were superior to that of the 19 patients. CONCLUSIONS: A peripancreatic vascular reconstruction can reveal the vascular anatomy, variations of peripancreatic vascular, and tumor-induced vascular changes; the application of the simulation surgery platform could reduce surgical trauma and decrease operative time.


Asunto(s)
Vasos Sanguíneos/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Periodo Preoperatorio , Tomografía Computarizada Espiral/métodos , Adulto , Anciano , Angiografía/métodos , Arterias/patología , Duodeno/irrigación sanguínea , Duodeno/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Páncreas/irrigación sanguínea , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/irrigación sanguínea , Neoplasias Pancreáticas/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Método Simple Ciego , Resultado del Tratamiento , Venas/patología , Adulto Joven
19.
Hepatogastroenterology ; 61(131): 613-22, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-26176045

RESUMEN

BACKGROUND/AIMS: Three-dimensional (3D) imaging may improve surgical interventions for complicated hepatolithiasis. METHODOLOGY: Between July 2008 and December 2012 a total of 131 patients with complicated hepatolithiasis underwent surgical therapy in the Department of Hepatobiliary Surgery Zhujiang Hospital, Southern Medical University. 77 patients received preoperative planning using a computed tomography (CT)-based 3D reconstruction technique, and 54 received treatment based on preoperative planning with traditional imaging (CT, ultrasonography, magnetic resonance imaging/magnetic resonance cholangiography). Perioperative and long-term outcomes were analyzed. RESULTS: 3D reconstruction facilitated significantly more accurate diagnosis of pathological morphology than conventional imaging methods, as confirmed during surgery. Patients that received 3D reconstruction preoperative planning had significantly better clinical outcomes. The immediate stone clearance rates were 92.2% and 61.1%, respectively. Additional postoperative choledochoscopic lithotripsy raised the clearance rates to 94.8% and 81.5%, respectively. The hospital mortality rates were 0% and 1.9%, respectively, and the complication rates were 33.8% and 44.4%, respectively. With a median follow-up of 28 months (5-38 months), the long-term overall asymptomatic survival rates were 80.5% and 46.3%, respectively. 3D reconstruction preoperative planning was a significant prognostic protective factor of long-term asymptomatic survival for the patients with complicated hepatolithiasis (Cox regression analysis, RR = 0.348, 95% confidence interval 0.185-0.657, p = 0.001). CONCLUSION: Surgical therapy conducted following preoperative planning using 3D reconstruction achieved better clinical outcomes than conventional imaging techniques. Whilst conventional imaging techniques accurately identify intrahepatic stones, they are less capable of identifying bile duct stricture.


Asunto(s)
Colecistectomía/métodos , Imagenología Tridimensional , Litiasis/cirugía , Hepatopatías/cirugía , Tomografía Computarizada Multidetector , Interpretación de Imagen Radiográfica Asistida por Computador , Cirugía Asistida por Computador/métodos , Adulto , Anciano , China , Colangiopancreatografia Retrógrada Endoscópica , Pancreatocolangiografía por Resonancia Magnética , Colecistectomía/efectos adversos , Colecistectomía/mortalidad , Femenino , Humanos , Litiasis/complicaciones , Litiasis/diagnóstico por imagen , Litiasis/mortalidad , Hepatopatías/complicaciones , Hepatopatías/diagnóstico por imagen , Hepatopatías/mortalidad , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/mortalidad , Factores de Tiempo , Resultado del Tratamiento
20.
Hepatogastroenterology ; 61(135): 1901-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25713886

RESUMEN

BACKGROUND/AIMS: The aim of this study was to compare the results of the Three-Dimensional Visualization System (MI-3DVS or 3D) in the diagnostic accuracy of hepatolithiasis. METHODOLOGY: From February 2007 to March 2013, forty-eight patients with hepatolithiasis were admitted to our department. Meanwhile, choosing forty-one patients without hepatolithiasis as controlgroup. MI-3DVS, MRCP, CT, and US were performed and the results of these imaging methods in detecting calculi distribution, bile duct dilatation/stricture, and liver atrophy/hypertrophy were analyzed. RESULTS: The total display accuracy on bile duct stricture/dilatation using by 3D was higher than using by MRCP, CT, US. The total accuracy of 3D in detecting the liver atrophy was 96.6%, which was superior to that of US (p=0.009) and CT (p=0.044), and there was no significant difference compared with MRCP (P=0.120). The results on diagnosis of calculi distribution by 3D was better than US (p=0.003) and MRCP (p=0.029), but had no significantly difference compared with CT (P=0.246), and they were all close to intraoperative findings. CONCLUSIONS: MI-3DVS could be used to select patients with hepatolithiasis as a supplement approach to other imaging methods and as an innovative means in pre-operative assessment and post-operative follow-ups in hepatolithiasis.


Asunto(s)
Conductos Biliares , Pancreatocolangiografía por Resonancia Magnética , Colelitiasis/diagnóstico , Endosonografía , Imagenología Tridimensional , Hígado , Tomografía Computarizada por Rayos X , Atrofia , Conductos Biliares/diagnóstico por imagen , Conductos Biliares/patología , Estudios de Casos y Controles , Colelitiasis/diagnóstico por imagen , Colelitiasis/patología , Constricción Patológica , Dilatación Patológica , Femenino , Humanos , Hipertrofia , Hígado/diagnóstico por imagen , Hígado/patología , Masculino , Persona de Mediana Edad , Imagen Multimodal , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...