Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomed Res Int ; 2021: 6652250, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33628801

RESUMEN

OBJECTIVES: To evaluate the in vitro effectiveness of desensitizing agents in reducing dentine permeability. METHODS: The efficacy of desensitizing agents in reducing dentine permeability by occluding dentine tubules was evaluated using a fluid filtration device that conducts at 100 cmH2O (1.4 psi) pressure, and SEM/EDX analyses were evaluated and compared. Forty-two dentine discs (n = 42) of 1 ± 0.2 mm width were obtained from caries-free permanent human molars. Thirty dentine discs (n = 30) were randomly divided into 3 groups (n = 10): Group 1: 2.7% wt. monopotassium-monohydrogen oxalate (Mp-Mh oxalate), Group 2: RMGI XT VAR, and Group 3: LIQ SiO2. Dentine permeability was measured following treatment application after 10 minutes, storage in artificial saliva after 10 minutes and 7 days, and citric acid challenge for 3 minutes. Data were analysed with a repeated measures ANOVA test. Dentine discs (n = 12) were used for SEM/EDX analyses to acquire data on morphological changes on dentine surface and its mineral content after different stages of treatment. RESULTS: Desensitizing agents' application on the demineralized dentine discs exhibited significant reduction of permeability compared to its maximum acid permeability values. Mp-Mh oxalate showed a significant reduction in dentine permeability (p < 0.05) when compared to RMGI XT VAR and LIQ SiO2. On SEM/EDX analysis, all the agents formed mineral precipitates that occluded the dentine tubules. CONCLUSIONS: 2.7% wt. monopotassium-monohydrogen oxalate was significantly effective in reducing dentine permeability compared to RMGI XT VAR and LIQ SiO2.


Asunto(s)
Desensibilizantes Dentinarios , Permeabilidad de la Dentina/efectos de los fármacos , Sensibilidad de la Dentina , Dentina/metabolismo , Diente Molar/metabolismo , Desensibilizantes Dentinarios/química , Desensibilizantes Dentinarios/farmacología , Sensibilidad de la Dentina/tratamiento farmacológico , Sensibilidad de la Dentina/metabolismo , Humanos
2.
Biomed Res Int ; 2018: 4072815, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30276206

RESUMEN

The effectiveness of remineralizing agents in reducing dentine permeability by tubule occlusion using fluid filtration device functioning at 100 cmH2O (1.4 psi) pressure and SEM/EDX analysis were evaluated and compared. Seventy (n = 70) dentine discs of 1±0.2 mm width were prepared from sound permanent human molars. Fifty (n = 50) dentine discs were randomly divided into 5 groups (n = 10): Group 1: GC Tooth Mousse Plus (Recaldent GC Corporation Tokyo, Japan), Group 2: Clinpro™ White Varnish (3M ESPE, USA), Group 3: Duraphat® Varnish (Pharbil Waltrop GmbH, Germany), Group 4: Colgate Sensitive Pro-Relief™ dentifrice (Colgate Palmolive, Thailand), and Group 5: Biodentine™ (Septodont/UK). Dentine permeability was measured after treatment application at 10 minutes, artificial saliva immersion at 7 days, and citric acid challenge for 3 minutes. Data were analyzed by two-way repeated measures ANOVA. Dentine specimens (n = 20) were used for SEM/EDX analyses to obtain qualitative results on dentine morphology and surface deposits. Each treatment agent significantly reduced dentine permeability immediately after treatment application and created precipitates on treated dentine surfaces. All agents increased permeability values after 7 days of artificial saliva immersion except Clinpro White Varnish and Biodentine. Clinpro White Varnish exhibited significant resistance to acid challenge compared to others. Colgate Sensitive Pro-Relief dentifrice has a dual mechanism of action in reducing the dentine sensitivity.


Asunto(s)
Desensibilizantes Dentinarios/farmacología , Permeabilidad de la Dentina , Humanos , Microscopía Electrónica de Rastreo , Diente Molar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA