Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMJ Case Rep ; 14(4)2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33906889

RESUMEN

Here, we present an interesting case of seroma following hip resurfacing arthroplasty in a 69-year-old man. During the postoperative recovery, the patient made rapid progress and returned to intense activity within the 6-week period. He subsequently developed further right hip pain and swelling. On further examination and on ultrasound scan, a lateral thigh collection was noted. All inflammatory markers were within normal parameters; clinically, there was no evidence of active infection. On initial aspiration and washout, there was a large sterile haemoserous collection. The patient subsequently underwent further aspiration due to persistent collection. After this a revision procedure was performed in two stages with excision of the seroma cavity superficial to fascia lata. Methicillin-sensitive Staphylococcus aureus was grown on extended cultures which was treated successfully with antibiotics. After the second stage revision to total hip replacement, this cavity then recollected. A further trial of aspiration with injection of 200 mg doxycycline, a known sclerosing agent, was performed. The seroma resolved.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Infecciones Estafilocócicas , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Doxiciclina , Humanos , Masculino , Falla de Prótesis , Reoperación , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/cirugía
2.
Proc Inst Mech Eng H ; 233(12): 1318-1326, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31608770

RESUMEN

Hip resurfacing is an attractive alternative to total hip replacement preserving bone and reducing dislocation risk. Recent metal-on-metal designs have caused failure due to metal wear debris. Ceramic implants may mitigate this risk. Temperature increase in periprosthetic bone during cementation can lead to osteonecrosis, while deformation of the component can affect joint lubrication and may increase wear through clamping. Both processes may lead to implant loosening. This study quantifies the temperature and deformation change in a novel ceramic hip resurfacing femoral component compared to a metal standard during cemented implantation in a fresh frozen cadaveric model. Study design and methods Eight femora were prepared from four fresh frozen cadavers. One surgeon experienced in hip resurfacing surgery (J.H.) prepared the femora by reaming. Four ceramic and four metal implants of equal and varying size were cemented in place. Bone and surface temperatures were taken using a probe in the periprosthetic bone and an infrared laser thermometer, respectively. Deformation was measured using a micrometre. Measurements were taken before implantation and every 5-min intervals up to 30 min. The average bone-temperature increment was lower for ceramic heads than for metal heads. Although this difference was not statistically significant, the average bone temperature incremental change in small sizes (42 and 46 mm) was higher than in the large sizes (48 and 50 mm). Most metal heads sustained bearing diameter change that was still near its peak value 30 min after implantation, whereas the ceramic heads suffered a lower diameter change and most of the samples recovered their original diameter 30 min after implantation. Both implants behave similarly, however, a lower temperature rise in bone was observed with ceramic heads. This may lower the risk for thermal damage on periprosthetic bone. The ceramic heads deformed less during surgical implantation. This was not significant.


Asunto(s)
Cerámica , Fémur/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Fenómenos Mecánicos , Metales , Temperatura , Cadáver , Femenino , Humanos , Diseño de Prótesis
3.
Proc Inst Mech Eng H ; 233(6): 603-610, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31017527

RESUMEN

Hip resurfacing is an attractive alternative to total hip replacement preserving bone and reducing dislocation risk. Recent metal-on-metal designs have caused failure due to metal wear debris. Ceramic implants may mitigate this risk. Deformation of the acetabular cup can affect the lubrication, producing high friction torques between the femoral head and the cup that would increase wear and/or lead to cup loosening due to femoral head clamping. Our objective was to quantify the deformation of a novel monobloc ceramic hip resurfacing cup component compared to a metal standard, in a fresh frozen cadaveric model using a press-fit technique representative of standard surgical conditions. For this study eight acetabula were prepared from four fresh frozen cadavers. One surgeon with extensive experience in hip resurfacing surgery (J.H.) prepared the acetabulum by sequential reaming. The implants were then impacted into the acetabulum. Four ceramic and four metal implants were used of equal and varying size. Deformation was measured peri-implantation, and at 30 min, using an optical high-precision deformation sensor (GOM GmbH, Braunschweig, Germany). The maximum inscribed circle and the measurement of radial segment techniques were used. Deformation was greater in the metal implants (mean: 34-22mm) immediately after implantation. At 30 min after implantation, the deformation increased to 36mm in the metal and 26mm in the ceramic cup. Greater diameter changes were observed in larger cups. Metal and ceramic implants did not return to the initial diameter. We conclude the ceramic resurfacing acetabular implants undergo similar deformation to existing metal-on-metal implants. The deformation observed was significantly less in the ceramic component at 30 min on one measure. Less deformation may result in better surface conditions and wear characteristics. Deformation change did not resolve after 30 min for both implants.


Asunto(s)
Acetábulo/anatomía & histología , Cerámica , Prótesis de Cadera , Metales , Implantación de Prótesis/instrumentación , Acetábulo/cirugía , Anciano , Cadáver , Femenino , Articulación de la Cadera/cirugía , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...