Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Female Pelvic Med Reconstr Surg ; 26(11): e44-e46, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32910079

RESUMEN

We present the case of a patient with recurrent sigmoid neovaginal prolapse treated with a modified Altemeier procedure for rectal prolapse, which has not been previously described in the literature.Our case highlights the difficulty in treating patients with intestinal neovaginal prolapse due to their complex abdominal surgical history, altered anatomy, and goals of care.


Asunto(s)
Colon Sigmoide/cirugía , Procedimientos de Cirugía Plástica/métodos , Prolapso Uterino/cirugía , Vagina/cirugía , Femenino , Humanos , Persona de Mediana Edad , Rabdomiosarcoma/cirugía
2.
Ophthalmic Surg Lasers Imaging Retina ; 48(1): 34-52, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28060392

RESUMEN

BACKGROUND AND OBJECTIVE: To evaluate safety and efficacy of intravitreal aflibercept (Eylea; Regeneron, Tarrytown, NY) injection (IAI) for the treatment of neovascular polypoidal choroidal vasculopathy (PCV) in a predominantly non-Asian population. PATIENTS AND METHODS: This was an open-label, prospective, unmasked, nonrandomized clinical trial. Twenty eyes with neovascular PCV received monthly 2.0 mg IAI for 3 months followed by mandatory IAI every 2 months for 12 months. RESULTS: The mean change in ETDRS best-corrected visual acuity from baseline to 1 year was +11 letters in the treatment-naïve group, +5 letters in the treatment non-naïve group, and +9 letters overall. There was an overall mean reduction of 70 µm from baseline central subfield thickness (CST) at 1 year. Patients received a mean of 6.2 mandatory and 0.7 additional IAI injections overall during the course of 1 year. No serious ocular adverse events were reported. CONCLUSION: At 1 year, neovascular PCV in a predominantly non-Asian population treated with IAI demonstrated favorable visual, anatomic, and safety outcomes. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:34-44.].


Asunto(s)
Coroides/irrigación sanguínea , Neovascularización Coroidal/tratamiento farmacológico , Pólipos/tratamiento farmacológico , Receptores de Factores de Crecimiento Endotelial Vascular/administración & dosificación , Proteínas Recombinantes de Fusión/administración & dosificación , Anciano , Anciano de 80 o más Años , Coroides/patología , Neovascularización Coroidal/diagnóstico , Relación Dosis-Respuesta a Droga , Femenino , Angiografía con Fluoresceína , Estudios de Seguimiento , Fondo de Ojo , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad , Pólipos/diagnóstico , Estudios Prospectivos , Receptores de Factores de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Agudeza Visual
3.
Ophthalmic Surg Lasers Imaging Retina ; 47(11): 1-18, 2016 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-27842191

RESUMEN

BACKGROUND AND OBJECTIVE: To evaluate the safety and efficacy of 0.3 mg ranibizumab (Lucentis; Genentech, South San Francisco, CA) in eyes with persistent diabetic macular edema (DME) after recent, chronic, and frequent bevacizumab (Avastin; Genentech, South San Francisco, CA). PATIENTS AND METHODS: Open-label, prospective study of 0.3 mg ranibizumab for eyes with persistent DME after bevacizumab. Thirty eyes randomized to a sustained group or a pro re nata (PRN) dosing group. RESULTS: The mean change in ETDRS best-corrected visual acuity from baseline to 1 year was +6.7 letters in the sustained group, +6.4 letters in the PRN group, and +6.5 letters overall. There was an overall mean reduction of 116 µm from baseline central subfield thickness at 1 year, with -92 µm and -127 µm decreases in the sustained and PRN groups, respectively. Adverse events included two deaths; one patient with multiple cardiopulmonary comorbidities, myocardial infarction, stroke, osteomyelitis; and mild posterior subcapsular cataracts in two eyes. CONCLUSION: Ranibizumab 0.3 mg demonstrated improved visual and anatomic outcomes in patients with persistent DME following bevacizumab. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:1030-1037.].


Asunto(s)
Retinopatía Diabética/tratamiento farmacológico , Edema Macular/tratamiento farmacológico , Ranibizumab/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Inhibidores de la Angiogénesis/efectos adversos , Inhibidores de la Angiogénesis/uso terapéutico , Bevacizumab/uso terapéutico , Femenino , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ranibizumab/efectos adversos , Tomografía de Coherencia Óptica , Agudeza Visual
4.
J Orthop Surg Res ; 11(1): 107, 2016 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-27671529

RESUMEN

BACKGROUND: Metallic reconstruction plates used for fracture stabilization typically require intraoperative contouring for patient-specific anatomical fit. Despite this, characterization of plate mechanical properties after contouring has previously been limited. The objective of this study was to assess whether contouring affects fatigue resistance for three types of Stryker seven-hole stainless steel (SS) 316LVM fracture fixation plates. The hypothesis was that for each plate type, more contouring repetitions would result in lower fatigue resistance. METHODS: Plates were contoured using a bench-top plate bender to ±20° either 0×, 3×, 6×, or 9× (n = 5 per group) and tested in the straight configuration. Cyclic four-point bending was applied in an incremental stepwise staircase approach (one step = 100,000 cycles, 10 Hz) until failure (defined as brittle fracture or plastic deformation of 10° permanent bend). Moment-cycle product (MCP) was computed as the summation of maximum moment × number of cycles and used as the primary measure of fatigue resistance. RESULTS: No significant differences in fatigue resistance were detected between contouring groups for Basic Fragment Set (BFS) Reconstruction Plates. Significantly lower fatigue resistance was measured for 9× contoured Matta Pelvic System (MPS) Straight Plates compared to 0× contoured plates (p = 0.023). MPS Flex Plates contoured 3× had greater fatigue resistance than 0× contoured (p = 0.031) and 9× contoured plates (p = 0.032). CONCLUSIONS: This work provides fatigue resistance-based evidence that clinicians should avoid high repetitions of contouring for MPS Straight Plates. Meanwhile, BFS Reconstruction Plates and MPS Flex Plates are not negatively affected by contouring. These results allow for improved intraoperative decisions about using or discarding plates after multiple contouring repetitions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA