Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
AJNR Am J Neuroradiol ; 42(8): 1472-1478, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34083260

RESUMEN

BACKGROUND: Infarct volume inversely correlates with good recovery in stroke. The magnitude and predictors of infarct growth despite successful reperfusion via endovascular treatment are not known. PURPOSE: We aimed to summarize the extent of infarct growth in patients with acute stroke who achieved successful reperfusion (TICI 2b-3) after endovascular treatment. DATA SOURCES: We performed a systematic review and meta-analysis by searching MEDLINE and Google Scholar for articles published up to October 31, 2020. STUDY SELECTION: Studies of >10 patients reporting baseline and post-endovascular treatment infarct volumes on MR imaging were included. Only patients with TICI 2b-3 were included. We calculated infarct growth at a study level as the difference between baseline and follow-up MR imaging infarct volumes. DATA ANALYSIS: Our search yielded 345 studies, and we included 10 studies reporting on 973 patients having undergone endovascular treatment who achieved successful reperfusion. DATA SYNTHESIS: The mean baseline infarct volume was 19.5 mL, while the mean final infarct volume was 37.5 mL. A TICI 2b reperfusion grade was achieved in 24% of patients, and TICI 2c or 3 in 76%. The pooled mean infarct growth was 14.8 mL (95% CI, 7.9-21.7 mL). Meta-regression showed higher infarct growth in studies that reported higher baseline infarct volumes, higher rates of incomplete reperfusion (modified TICI 2b), and longer onset-to-reperfusion times. LIMITATIONS: Significant heterogeneity among studies was noted and might be driven by the difference in infarct growth between early- and late-treatment studies. CONCLUSIONS: These results suggest considerable infarct growth despite successful endovascular treatment reperfusion and call for a faster workflow and the need for specific therapies to limit infarct growth.


Asunto(s)
Isquemia Encefálica , Procedimientos Endovasculares , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/cirugía , Humanos , Infarto , Reperfusión , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento
2.
AJNR Am J Neuroradiol ; 41(5): 792-797, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32327438

RESUMEN

BACKGROUND AND PURPOSE: Infarct volume in acute ischemic stroke is an important prognostic marker and determines endovascular treatment decisions. This study evaluates the magnitude and potential clinical impact of the error related to partial volume effects in infarct volume measurement on diffusion-weighted MR imaging in acute stroke and explores how increasing spatial resolution could reduce this error. MATERIALS AND METHODS: Diffusion-weighted imaging of 393 patients with acute stroke, of whom 56 had anterior circulation large-vessel occlusion, was coregistered to standard space. Lesion boundaries were manually segmented. A 3D lesion-volume model was resampled for voxel sizes from 4 × 4 × 8 to 1 × 1 × 2 mm, and the surface-volume, corresponding to the partial volume error, was calculated. The number of cases with anterior circulation large-vessel occlusion, in which the endovascular therapy core threshold of 70 mL was contained within the margin of error, was calculated as a function of imaging resolution. RESULTS: The mean infarct core volume was 27.2 ± 49.9 mL. The mean surface volume was 14.7 ± 20.8 mL for 2 × 2 × 4 mm resolution and 7.4 ± 10.7 mL for 1 × 1 × 2 mm resolution. With a resolution of 2 × 2 × 4 mm, 70 mL was contained within the margin of error in 7/56 cases (12.5%) with large-vessel occlusion, while with a 1 × 1 × 2 mm voxel size, the margin of error was 3/56 (5%). The lesion-volume range of potentially misclassified lesions dropped from 46.5-94.1 mL for a 2 × 2 × 4 mm resolution to 64.4-80.1 mL for a 1 × 1 × 2 mm resolution. CONCLUSIONS: Partial volume effect is an important source of error in infarct volume measurement in acute stroke. Increasing spatial resolution substantially decreases the mean error. Standard use of high-resolution DWI should be considered to increase the reliability of infarct volume measurements.


Asunto(s)
Artefactos , Infarto Encefálico/diagnóstico por imagen , Infarto Encefálico/patología , Interpretación de Imagen Asistida por Computador/métodos , Neuroimagen/métodos , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
3.
AJNR Am J Neuroradiol ; 37(12): 2251-2257, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27561834

RESUMEN

BACKGROUND AND PURPOSE: Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. MATERIALS AND METHODS: Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0-900 s/mm2). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values >200 s/mm2. Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R2) were computed for the simplified model, with biexponential fitting as the reference standard. RESULTS: Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P < .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R2) compared with full biexponential fitting. CONCLUSIONS: Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.


Asunto(s)
Encéfalo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Modelos Teóricos , Encéfalo/patología , Neoplasias Encefálicas/irrigación sanguínea , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Glioma/irrigación sanguínea , Glioma/diagnóstico por imagen , Glioma/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Movimiento (Física) , Imagen de Perfusión/métodos , Reproducibilidad de los Resultados , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/patología
4.
Cerebrovasc Dis ; 38(2): 117-20, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25278110

RESUMEN

BACKGROUND: The effects of intravenous thrombolysis on floating thrombi in cervical and intracranial arteries of acute ischemic stroke patients are unknown. Similarly, the best prevention methods of early recurrences remain controversial. This study aimed to describe the clinical and radiological outcome of thrombolyzed strokes with floating thrombi. METHODS: We retrospectively analyzed all thrombolyzed stroke patients in our institution between 2003 and 2010 with floating thrombi on acute CT-angiography before the intravenous thrombolysis. The floating thrombus was diagnosed if an elongated thrombus of at least 5 mm length, completely surrounded by contrast on supra-aortic neck or intracerebral arteries, was present on CT-angiography. Demographics, vascular risk factors, and comorbidities were recorded and stroke etiology was determined after a standardized workup. Repeat arterial imaging was performed by CTA at 24 h or before if clinical worsening was noted and then by Doppler and MRA during the first week and at four months. RESULTS: Of 409 thrombolyzed stroke patients undergoing acute CT Angiography, seven (1.7%) had a floating thrombus; of these seven, six had it in the anterior circulation. Demographics, risk factors and stroke severity of these patients were comparable to the other thrombolyzed patients. After intravenous thrombolysis, the floating thrombi resolved completely at 24 h in four of the patients, whereas one had an early recurrent stroke and one developed progressive worsening. One patient developed early occlusion of the carotid artery with floating thrombus and subsequently a TIA. The two patients with a stable floating thrombus had no clinical recurrences. In the literature, only one of four reported cases were found to have a thrombolysis-related early recurrence. CONCLUSIONS: Long-term outcome seemed similar in thrombolyzed patients with floating thrombus, despite a possible increase of very early recurrence. It remains to be established whether acute mechanical thrombectomy could be a safer and more effective treatment to prevent early recurrence. However, intravenous thrombolysis should not be withheld in eligible stroke patients.


Asunto(s)
Isquemia Encefálica/tratamiento farmacológico , Fibrinolíticos/efectos adversos , Trombosis/tratamiento farmacológico , Activador de Tejido Plasminógeno/efectos adversos , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Angiografía Cerebral/métodos , Femenino , Fibrinolíticos/administración & dosificación , Fibrinolíticos/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Tejido Plasminógeno/uso terapéutico , Resultado del Tratamiento
5.
Neuroradiology ; 56(8): 629-35, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24838807

RESUMEN

INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p=2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p=1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Angiografía por Resonancia Magnética , Accidente Cerebrovascular/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Circulación Cerebrovascular , Preescolar , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Humanos , Masculino , Microcirculación , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
6.
AJNR Am J Neuroradiol ; 35(2): 256-62, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23928134

RESUMEN

BACKGROUND AND PURPOSE: Intravoxel incoherent motion MRI has been proposed as an alternative method to measure brain perfusion. Our aim was to evaluate the utility of intravoxel incoherent motion perfusion parameters (the perfusion fraction, the pseudodiffusion coefficient, and the flow-related parameter) to differentiate high- and low-grade brain gliomas. MATERIALS AND METHODS: The intravoxel incoherent motion perfusion parameters were assessed in 21 brain gliomas (16 high-grade, 5 low-grade). Images were acquired by using a Stejskal-Tanner diffusion pulse sequence, with 16 values of b (0-900 s/mm(2)) in 3 orthogonal directions on 3T systems equipped with 32 multichannel receiver head coils. The intravoxel incoherent motion perfusion parameters were derived by fitting the intravoxel incoherent motion biexponential model. Regions of interest were drawn in regions of maximum intravoxel incoherent motion perfusion fraction and contralateral control regions. Statistical significance was assessed by using the Student t test. In addition, regions of interest were drawn around all whole tumors and were evaluated with the help of histograms. RESULTS: In the regions of maximum perfusion fraction, perfusion fraction was significantly higher in the high-grade group (0.127 ± 0.031) than in the low-grade group (0.084 ± 0.016, P < .001) and in the contralateral control region (0.061 ± 0.011, P < .001). No statistically significant difference was observed for the pseudodiffusion coefficient. The perfusion fraction correlated moderately with dynamic susceptibility contrast relative CBV (r = 0.59). The histograms of the perfusion fraction showed a "heavy-tailed" distribution for high-grade but not low-grade gliomas. CONCLUSIONS: The intravoxel incoherent motion perfusion fraction is helpful for differentiating high- from low-grade brain gliomas.


Asunto(s)
Algoritmos , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/fisiopatología , Circulación Cerebrovascular , Glioma/diagnóstico , Glioma/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Niño , Preescolar , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...