Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 15(1): 8074, 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39277587

RESUMEN

Smart windows, capable of tailoring light transmission, can significantly reduce energy consumption in building services. While mechano-responsive windows activated by strains are promising candidates, they face long-lasting challenges in which the space for the light scatterer's operation has to be enlarged along with the window size, undermining the practicality. Recent attempts to tackle this challenge inevitably generate side effects with compromised performance in light modulation. Here, we introduce a cuttlefish-inspired design to enable the closing and opening of pores within the 3D porous structure by through-thickness compression, offering opacity and transparency upon release and compression. By changing the activation mode from the conventional in-plane to through-thickness direction, the space requirement is intrinsically decoupled from the lateral size of the scatterer. Central to our design is the asymmetry of pore orientation in the 3D porous structure. These inclined pores against the normal direction increase the opaqueness upon release and improve light modulation sensitivity to compression, enabling transmittance regulation upon compression by an infinitesimal displacement of 50 µm. This work establishes a milestone for smart window technologies and will drive advancements in the development of opto-electric devices.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38083148

RESUMEN

Stroke is a debilitating condition that leads to a loss of motor function, inability to perform daily life activities, and ultimately worsening quality of life. Robot-based rehabilitation is a more effective method than conventional rehabilitation but needs to accurately recognize the patient's intention so that the robot can assist the patient's voluntary motion. This study focuses on recognizing hand grasp motion intention using high-density electromyography (HD-EMG) in patients with chronic stroke. The study was conducted with three chronic stroke patients and involved recording HD-EMG signals from the muscles involved in hand grasp motions. The adaptive onset detection algorithm was used to accurately identify the start of hand grasp motions accurately, and a convolutional neural network (CNN) was trained to classify the HD-EMG signals into one of four grasping motions. The average true positive and false positive rates of the grasp onset detection on three subjects were 91.6% and 9.8%, respectively, and the trained CNN classified the grasping motion with an average accuracy of 76.3%. The results showed that using HD-EMG can provide accurate hand grasp motion intention recognition in chronic stroke patients, highlighting the potential for effective robot-based rehabilitation.


Asunto(s)
Mano , Accidente Cerebrovascular , Humanos , Electromiografía/métodos , Mano/fisiología , Intención , Calidad de Vida , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico , Fuerza de la Mano/fisiología
3.
Artículo en Inglés | MEDLINE | ID: mdl-38083274

RESUMEN

Accurate gait phase detection is crucial for safe and efficient robotic prosthesis control in lower limb amputees. Several sensing modalities, including mechanical and biological signals, have been proposed to improve the accuracy of gait phase detection. In this paper, we propose a bioimpedance and sEMG fusion sensor for high-accuracy gait phase detection. We fabricated a wearable band-type sensor for multichannel bioimpedance and sEMG measurement, and we conducted gait experiments with a transtibial amputee to obtain biosignal data. Finally, we trained a deep-learning-based gait phase detection algorithm and evaluated its detection performance. Our results showed that using both bioimpedance and sEMG yielded the highest accuracy of 95.1%. Using only sEMG yielded a higher accuracy (90.9%) than that using only bioimpedance (85.1%). Therefore, we conclude that using both signals simultaneously is beneficial for improving the accuracy of gait phase detection. In addition, the proposed sensor can be applied to several applications by improving the accuracy of motion intention detection.


Asunto(s)
Amputados , Miembros Artificiales , Humanos , Marcha , Extremidad Inferior , Movimiento (Física)
4.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36176084

RESUMEN

Rehabilitation of the hand motor function is essential for stroke patients to resume activities of daily living. Recent studies have shown that wearable robot systems, like a multi degree-of-freedom soft glove, have the potential to improve hand motor impairment. The rehabilitation system, which is intuitively controlled according to the user's intention, is expected to induce active participation of the user and further promote brain plasticity. However, due to the patient-specific nature of stroke patients, extracting the intention from stroke patients is still challenging. In this study, we implemented a classifier that combines EEG and EMG to detect chronic stroke patients' four types of intention: rest, grasp, hold, and release. Three chronic stroke patients participated in the experiment and performed rest, grasp, hold, and release actions. The rest vs. grasp binary classifier and release vs. hold binary classifier showed 76.9% and 86.6% classification accuracy in real-time, respectively. In addition, patient-specific accuracy comparisons showed that the hybrid approach was robust to upper limb impairment level compared to other approaches. We believe that these results could pave the way for the development of BCI-based robotic hand rehabilitation therapy.


Asunto(s)
Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Actividades Cotidianas , Electroencefalografía/métodos , Mano , Fuerza de la Mano , Humanos , Intención , Rehabilitación de Accidente Cerebrovascular/métodos
5.
Artículo en Inglés | MEDLINE | ID: mdl-35925857

RESUMEN

To prevent lower back pain (LBP) in the industrial workplace, various powered back support exoskeletons (BSEs) have been developed. However, conventional kinematics-triggered assistance (KA) strategies induce latency, degrading assistance efficiency. Therefore, we proposed and experimentally evaluated a surface electromyography (sEMG)-triggered assistance (EA) strategy. Nine healthy subjects participated in the lifting experiments: 1) external loads test, 2) extra latency test, and 3) repetitive lifting test. In the external loads test, subject performed lifting with four different external loads (0 kg, 7.5 kg, 15 kg, and 22.5 kg). The assistance was triggered earlier by EA compared to KA from 114 ms to 202 ms, 163 ms to 269 ms for squat and stoop lifting respectively, as external loads increased from 0 kg to 22.5 kg. In the extra latency test, the effects of extra latency (manual switch, 0 ms, 100 ms and 200 ms) in EA on muscle activities were investigated. Muscle activities were minimized in the fast assistance (0 ms and 100 ms) condition and increased with extra latency. In the repetitive lifting test, the EA strategy significantly reduced L1 muscle fatigue by 70.4% in stoop lifting, compared to KA strategy. Based on the experimental results, we concluded that fast assistance triggered by sEMG improved assistance efficiency in BSE and was particularly beneficial in heavy external loads situations. The proposed assistive strategy can be used to prevent LBP by reducing back muscle fatigue and is easily applicable to various industrial exoskeleton applications.


Asunto(s)
Dispositivo Exoesqueleto , Dolor de la Región Lumbar , Dorso/fisiología , Fenómenos Biomecánicos , Electromiografía/métodos , Humanos , Elevación , Dolor de la Región Lumbar/prevención & control , Músculo Esquelético/fisiología
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4130-4133, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33018907

RESUMEN

In recent years, high-density surface electromyography (HD-sEMG) has shown promising advantages in many robotics applications. Using HD-sEMG can not only reduce the sensitivity of the sensor position on the muscle belly but can also facilitate the acquisition of more muscle activity information due to spatial sampling. As current commercial HD-EMG systems use stationary amplifiers, leading to bulky measurements and poor portability, the interest in developing an HD-EMG sensor has increased. However, the insufficient electrode density and complicated fabrication process are challenges to overcome. In this paper, we propose a flexible HD-EMG sensor with an on-board amplifier capable of a density level of 0.53 channel/cm2, higher than those in previous works. First, we investigated the effects of different sensor parameters (i.e., the electrode material, the inter-electrode distance (IED) and the size of the electrode) on the measured signal quality. Second, a low-cost, easily fabricated, easily customized HD-EMG fabrication method was proposed based on the selected sensor parameters with a signal-to-noise ratio (SNR) comparable to those of commercial sensors. Finally, we applied a muscle activation estimation algorithm to validate the feasibility of the designed HD-EMG sensor, showing higher estimation accuracy levels. The results here demonstrate that the designed HD-EMG sensor can be used as an effective human-machine interface for robotics applications.


Asunto(s)
Algoritmos , Músculo Esquelético , Amplificadores Electrónicos , Electrodos , Electromiografía , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA