Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neuroradiology ; 65(2): 391-399, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36271057

RESUMEN

PURPOSE: Embolization of arteriovenous malformations (AVMs) before radiosurgery has been reported to negatively impact the obliteration rate. This study aims to assess treatment outcomes in a series of 190 patients treated by Gamma Knife radiosurgery (GKRS) for previously embolized AVMs. METHODS: The institutional database of AVMs was retrospectively reviewed between January 2004 and March 2018. The clinical and radiological data of patients treated with GKRS for previously embolized AVMs were analyzed. Predicting factors of obliteration and hemorrhage following GKRS were assessed with univariate and multivariate regression analyses. RESULTS: The mean AVM size was significantly reduced after embolization (p < 0.001). The obliteration rate was 78.4%. Multivariate analyses showed that a lower Spetzler-Martin grade (p = 0.035) and a higher marginal dose (p = 0.007) were associated with obliteration. Post-GKRS hemorrhages occurred in 14 patients (7.4%). A longer time between diagnosis and GKRS was the only factor associated with post-GKRS hemorrhages in multivariate analysis (p = 0.022). Complications related to the combined treatment were responsible for a new permanent neurological disability in 20 patients (10.5%), and a case of death (0.5%). CONCLUSIONS: This study shows that the embolization of AVMs does not have a negative impact on the obliteration rate after radiosurgery. Embolization reduces the AVM size to a treatable volume by GKRS. However, the combined treatment results in an increased complication rate related to the addition of the risks of each treatment modality.


Asunto(s)
Embolización Terapéutica , Malformaciones Arteriovenosas Intracraneales , Radiocirugia , Humanos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/terapia , Malformaciones Arteriovenosas Intracraneales/complicaciones , Estudios de Seguimiento
2.
Biomed Phys Eng Express ; 8(6)2022 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-36049399

RESUMEN

INTRODUCTION: Radiomics is a promising imaging-based tool which could enhance clinical observation and identify representative features. To avoid different interpretations, the Image Biomarker Standardisation Initiative (IBSI) imposed conditions for harmonisation. This study evaluates IBSI-compliant radiomics applications against a known benchmark and clinical datasets for agreements. MATERIALS AND METHODS: The three radiomics platforms compared were RadiomiX Research Toolbox, LIFEx v7.0.0, and syngo.via Frontier Radiomics v1.2.5 (based on PyRadiomics v2.1). Basic assessment included comparing feature names and their formulas. The IBSI digital phantom was used for evaluation against reference values. For agreement evaluation (including same software but different versions), two clinical datasets were used: 27 contrast-enhanced computed tomography (CECT) of colorectal liver metastases and 39 magnetic resonance imaging (MRI) of breast cancer, including intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) MRI. The intraclass correlation coefficient (ICC, lower 95% confidence interval) was used, with 0.9 as the threshold for excellent agreement. RESULTS: The three radiomics applications share 41 (3 shape, 8 intensity, 30 texture) out of 172, 84 and 110 features for RadiomiX, LIFEx and syngo.via, respectively, as well as wavelet filtering. The naming convention is, however, different between them. Syngo.via had excellent agreement with the IBSI benchmark, while LIFEx and RadiomiX showed slightly worse agreement. Excellent reproducibility was achieved for shape features only, while intensity and texture features varied considerably with the imaging type. For intensity, excellent agreement ranged from 46% for the DCE maps to 100% for CECT, while this lowered to 44% and 73% for texture features, respectively. Wavelet features produced the greatest variation between applications, with an excellent agreement for only 3% to 11% features. CONCLUSION: Even with IBSI-compliance, the reproducibility of features between radiomics applications is not guaranteed. To evaluate variation, quality assurance of radiomics applications should be performed and repeated when updating to a new version or adding a new modality.


Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...