Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Neurochir (Wien) ; 166(1): 76, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38340225

RESUMEN

PURPOSE: External ventricular drain (EVD) implantation is one of the fundamental procedures of emergency neurosurgery usually performed freehand at bedside or in the operating room using anatomical landmarks. However, this technique is frequently associated with malpositioning leading to complications or dysfunction. Here, we describe a novel navigated bedside EVD insertion technique, which is evaluated in a clinical case series with the aim of safety, accuracy, and efficiency in neurosurgical emergency settings. METHODS: From 2021 to 2022, a mobile health-assisted navigation instrument (Thomale Guide, Christoph Miethke, Potsdam, Germany) was used alongside a battery-powered single-use drill (Phasor Health, Houston, USA) for bedside EVD placement in representative neurosurgical pathologies in emergency situations requiring ventricular cerebrospinal fluid (CSF) relief and intracranial pressure (ICP) monitoring. RESULTS: In all 12 patients (8 female and 4 male), navigated bedside EVDs were placed around the foramen of Monro at the first ventriculostomy attempt. The most frequent indication was aneurysmal subarachnoid hemorrhage. Mean operating time was 25.8 ± 15.0 min. None of the EVDs had to be revised due to malpositioning or dysfunction. Two EVDs were converted into a ventriculoperitoneal shunt. Drainage volume was 41.3 ± 37.1 ml per day in mean. Mean length of stay of an EVD was 6.25 ± 2.8 days. Complications included one postoperative subdural hematoma and cerebrospinal fluid infection, respectively. CONCLUSION: Combining a mobile health-assisted navigation instrument with a battery-powered drill and an appropriate ventricular catheter may enable and enhance safety, accuracy, and efficiency in bedside EVD implantation in various pathologies of emergency neurosurgery without adding relevant efforts.


Asunto(s)
Hemorragia Subaracnoidea , Humanos , Masculino , Femenino , Hemorragia Subaracnoidea/cirugía , Ventriculostomía/métodos , Drenaje/métodos , Derivación Ventriculoperitoneal , Quirófanos , Estudios Retrospectivos
2.
Spine J ; 23(12): 1799-1807, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37619869

RESUMEN

BACKGROUND CONTEXT: Due to the complexity of neurovascular structures in the atlantoaxial region, spinal navigation for posterior C1-C2 instrumentation is nowadays a helpful tool to increase accuracy of surgery and safety of patients. Many available intraoperative navigation devices have proven their reliability in this part of the spine. Two main imaging techniques are used: intraoperative CT (iCT) and cone beam computed tomography (CBCT). PURPOSE: Comparison of iCT- and CBCT-based technologies for navigated posterior instrumentation in C1-C2 instability. STUDY DESIGN: Retrospective study. PATIENT SAMPLE: A total of 81 consecutive patients from July 2014 to April 2020. OUTCOME MEASURES: Screw accuracy and operating time. METHODS: Patients with C1-C2 instability received posterior instrumentation using C2 pedicle screws, C1 lateral mass or pedicle screws. All screws were inserted using intraoperative imaging either using iCT or CBCT systems and spinal navigation with autoregistration technology. Following navigated screw insertion, a second intraoperative scan was performed to assess the accuracy of screw placement. Accuracy was defined as the percentage of correctly placed screws or with minor cortical breach (<2 mm) as graded by an independent observer compared to misplaced screws. RESULTS: A total of 81 patients with C1-C2 instability were retrospectively analyzed. Of these, 34 patients were operated with the use of iCT and 47 with CBCT. No significant demographic difference was found between groups. In the iCT group, 97.7% of the C1-C2 screws were correctly inserted; 2.3% showed a minor cortical breach (<2 mm); no misplacement (>2 mm). In the CBCT group, 98.9% of screws were correctly inserted; no minor pedicle breach; 1.1% showed misplacement >2 mm. Accuracy of screw placement demonstrated no significant difference between groups. Both technologies allowed sufficient identification of screw misplacement intraoperatively leading to two screw revisions in the iCT and three in the CBCT group. Median time of surgery was significantly shorter using CBCT technology (166.5 minutes [iCT] vs 122 minutes [CBCT]; p<.01). CONCLUSIONS: Spinal navigation using either iCT- or CBCT-based systems with autoregistration allows safe and reliable screw placement and intraoperative assessment of screw positioning. Using the herein presented procedural protocols, CBCT systems allow shorter operating time.


Asunto(s)
Inestabilidad de la Articulación , Tornillos Pediculares , Enfermedades de la Columna Vertebral , Fusión Vertebral , Cirugía Asistida por Computador , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada de Haz Cónico , Cirugía Asistida por Computador/métodos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Fusión Vertebral/métodos
3.
J Neurosurg ; 139(4): 1152-1159, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36933256

RESUMEN

OBJECTIVE: Endonasal endoscopic odontoidectomy (EEO) is an alternative to transoral surgery for symptomatic ventral compression of the anterior cervicomedullary junction (CMJ), allowing for earlier extubation and feeding. Because the procedure destabilizes the C1-2 ligamentous complex, posterior cervical fusion is often performed concomitantly. The authors' institutional experience was reviewed to describe the indications, outcomes, and complications in a large series of EEO surgical procedures in which EEO was combined with posterior decompression and fusion. METHODS: A consecutive, prospective series of patients who underwent EEO between 2011 and 2021 was studied. Demographic and outcome metrics, radiographic parameters, extent of ventral compression, extent of dens removal, and increase in CSF space ventral to the brainstem were measured on the preoperative and postoperative scans (first and most recent scans). RESULTS: Forty-two patients (26.2% pediatric) underwent EEO: 78.6% had basilar invagination, and 76.2% had Chiari type I malformation. The mean ± SD age was 33.6 ± 3.0 years, with a mean follow-up of 32.3 ± 4.0 months. The majority of patients (95.2%) underwent posterior decompression and fusion immediately before EEO. Two patients underwent prior fusion. There were 7 intraoperative CSF leaks but no postoperative CSF leaks. The inferior limit of decompression fell between the nasoaxial and rhinopalatine lines. The mean ± SD vertical height of dens resection was 11.98 ± 0.45 mm, equivalent to a mean ± SD resection of 74.18% ± 2.56%. The mean increase in ventral CSF space immediately postoperatively was 1.68 ± 0.17 mm (p < 0.0001), which increased to 2.75 ± 0.23 mm (p < 0.0001) at the most recent follow-up (p < 0.0001). The median (range) length of stay was 5 (2-33) days. The median time to extubation was 0 (0-3) days. The median time to oral feeding (defined as, at minimum, toleration of a clear liquid diet) was 1 (0-3) day. Symptoms improved in 97.6% of patients. Complications were rare and mostly associated with the cervical fusion portion of the combined surgical procedures. CONCLUSIONS: EEO is safe and effective for achieving anterior CMJ decompression and is often accompanied by posterior cervical stabilization. Ventral decompression improves over time. EEO should be considered for patients with appropriate indications.


Asunto(s)
Encefalopatías , Apófisis Odontoides , Humanos , Niño , Adulto , Imagen por Resonancia Magnética , Endoscopía/métodos , Nariz/cirugía , Tronco Encefálico/cirugía , Encefalopatías/cirugía , Descompresión Quirúrgica/métodos , Apófisis Odontoides/diagnóstico por imagen , Apófisis Odontoides/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...