Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
J Clin Med ; 11(7)2022 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-35407542

RESUMEN

Background: Persistent air leak is a common complication after lung resection causing prolonged length of stay and increased healthcare costs. Surgical intervention can be an option, but other more conservative approaches should be considered first. Here, we describe the use of flexible bronchoscopy to apply fibrin glue and autologous blood sequentially to the damaged lung. We named the technique "flexible thoracoscopy". METHODS: Medical records from patients with persistent air leaks after lung resection were collected retrospectively. Depending on the type of aerostasis that was performed, two groups were created: flexible thoracoscopy and surgery (thoracotomy). Flexible thoracoscopy was introduced at our institution in 2013. We entered the pleural space with a bronchoscope following the same surgical pathway that was used for tube thoracostomy. Perioperative characteristics and outcomes were analyzed using R software (ver. 3.4.4). RESULTS: From 1997 to 2021, a total of 23 patients required an intervention for persistent air leaks. Aerostasis was performed via flexible thoracoscopy in seventeen patients (69%) and via thoracotomy in six patients (31%). The median age was 70 years (22-82). Twenty patients were males (87%). There was no difference in age, sex distribution, BMI, comorbidities and FEV1%. An ASA score of 3 was more represented in the flexible thoracoscopy group; however, no evidence of a difference was found when compared to the thoracotomy group (p = 0.124). Length of in-hospital stay and chest tube duration was also similar between groups (p = 1 and p = 0.68, respectively). CONCLUSIONS: Aerostasis achieved either by flexible thoracoscopy or by thoracotomy showed similar results. We believe that flexible thoracoscopy could be a valid alternative to facilitate minimally invasive treatments for persistent air leaks. Further studies are needed to confirm these results.

2.
Thorac Surg Clin ; 28(4): 527-532, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30268298

RESUMEN

Endoluminal antireflux procedures were pioneered in the 1980s as an alternative to the more invasive Nissen fundoplication. Recent advances in device design and technique have generated renewed interest. Herein we review available data for currently available devices used for endoluminal therapy for GERD.


Asunto(s)
Fundoplicación/métodos , Reflujo Gastroesofágico/cirugía , Ablación por Radiofrecuencia/métodos , Endoscopía Gastrointestinal , Reflujo Gastroesofágico/diagnóstico , Reflujo Gastroesofágico/terapia , Humanos
3.
J Bras Pneumol ; 44(4): 307-314, 2018.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-30328929

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. METHODS: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. RESULTS: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). CONCLUSIONS: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias Pulmonares/patología , Nódulos Pulmonares Múltiples/patología , Neumotórax/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Gruesa/efectos adversos , Niño , Preescolar , Femenino , Hemorragia/etiología , Humanos , Biopsia Guiada por Imagen/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Nódulo Pulmonar Solitario/patología , Tomografía Computarizada por Rayos X , Adulto Joven
4.
J. bras. pneumol ; 44(4): 307-314, July-Aug. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-975920

RESUMEN

ABSTRACT Objective: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. Methods: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. Results: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). Conclusions: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high.


RESUMO Objetivo: Avaliar a precisão diagnóstica da biópsia percutânea com agulha grossa, guiada por TC - doravante denominada BAG-TC - de nódulos pulmonares ≤ 2 cm, bem como identificar fatores que influenciam a precisão do procedimento e sua morbidade. Métodos: Estudo retrospectivo, realizado em um único centro, com 170 pacientes consecutivos submetidos a BAG-TC de nódulos pulmonares pequenos (≤ 2 cm) entre janeiro de 2010 e agosto de 2015. Resultados: Do total de biópsias, 156 resultaram em diagnóstico definitivo, com precisão diagnóstica global de 92,3%. Lesões maiores estiveram relacionadas com maior precisão global (OR = 1,30; p = 0,007). A presença de hemorragia parenquimatosa durante o procedimento resultou em menor precisão (OR = 0,13; p = 0,022). Pneumotórax foi a complicação mais comum. Uma distância > 3 cm entre a lesão e a pleura foi identificada como fator de risco de pneumotórax (OR = 16,94), ao passo que a realização de tampão sanguíneo após a biópsia foi um fator de proteção contra o pneumotórax (OR = 0,18). Conclusões: O diagnóstico de nódulos pequenos (< 2 cm) é um desafio do ponto de vista técnico. A BAG-TC é uma excelente ferramenta diagnóstica, cuja precisão é alta.


Asunto(s)
Humanos , Masculino , Femenino , Preescolar , Niño , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Neumotórax/etiología , Nódulos Pulmonares Múltiples/patología , Biopsia con Aguja Gruesa/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X , Estudios Retrospectivos , Factores de Riesgo , Nódulo Pulmonar Solitario/patología , Biopsia con Aguja Gruesa/efectos adversos , Biopsia Guiada por Imagen/efectos adversos , Hemorragia/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...