Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Biol Macromol ; 238: 124100, 2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-36958443

RESUMEN

Human milk (HM) is essential for newborns' food, but its low storage stability is a limiting factor so that microencapsulation may stabilize and protect compounds sensitive to degradation. This study investigated the action of maltodextrin and gum arabic on freeze-dried HM concerning its quality and solubility. Microencapsulation was evidenced by morphology, and all samples presented high encapsulation efficiency (>85 %), proving to be an efficient process. Furthermore, specific signals in the Fourier-Transform Infrared (FTIR) spectra indicate the interactions between the coating materials and the HM matrix. Gum arabic improved the reconstitution properties of freeze-dried HM (higher solubility, 3 % on average, and lower dissolution time, around 80 %), elucidating its high stabilization capacity, even at low concentrations (5 and 10 %). Despite the best results reached by gum arabic, the addition of maltodextrin proved effective; in other words, its low stabilization capacity enables combinations with gum arabic. A lower polidispersibility (difference of 20 % between samples: control and containing gum arabic) was also observed, which means that the encapsulated samples were more homogeneous. Therefore, through the analysis performed, we recommend using gum arabic alone or with maltodextrin to obtain HM microcapsules with a good quality of reconstitution.


Asunto(s)
Goma Arábiga , Leche Humana , Recién Nacido , Humanos , Solubilidad , Cápsulas , Polisacáridos
2.
J Chromatogr Sci ; 60(8): 725-731, 2022 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-34999770

RESUMEN

The direct methylation method developed in this work for coffee samples allowed the determination of fatty acids using smaller sample amounts (100 mg), lower solvent volumes (5 mL) and shorter experimental run time (~12 min). Hence, the experiments are more economical and collaborate with green chemistry, besides favoring the health of the analyst who handles a smaller amount of solvents in a short period. Design Expert software was employed to determine the optimal concentration of the acid and base (0.7 e 1.75 molL-1) and evaluate the sonication time (5 min for both procedures). The experiments were carried out on different coffee samples in which the fat content ranging from 10.18% to 14.86%. The relative standard deviation values for intraday and interday were 2.78% and 7.8%, respectively, confirming the good precision of the proposed method for fatty acid derivatization.


Asunto(s)
Café , Ácidos Grasos , Cromatografía de Gases/métodos , Ácidos Grasos/química , Metilación , Solventes/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA