Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 114: 167-72, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27236833

RESUMEN

Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively.

2.
Appl Radiat Isot ; 109: 425-429, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26651164

RESUMEN

In this new approach, the active shielding of a low level spectrometer is monitored by an extendable dead time used as an "extendable GATE" signal. This concept is directly inspired from the live-timed anti-coincidence system implemented at LNE-LNHB (MTR2 modules). This allows a significant reduction in the cost and complexity of the system since several electronic modules are replaced by only one module dedicated specifically to this type of experiment. Settings of this new approach are detailed and results are discussed.

3.
Appl Radiat Isot ; 81: 67-70, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23623315

RESUMEN

In the framework of environmental measurements by gamma-ray spectrometry, some laboratories need to characterize samples in geometries for which a calibration is not directly available. A possibility is to use an efficiency transfer code, e.g., ETNA. However, validation for large volume sources, such as Marinelli geometries, is needed. With this aim in mind, ETNA is compared, initially to a Monte Carlo simulation (PENELOPE) and subsequently to experimental data obtained with a high-purity germanium detector (HPGe).


Asunto(s)
Algoritmos , Modelos Estadísticos , Monitoreo de Radiación/métodos , Monitoreo de Radiación/normas , Programas Informáticos , Espectrometría gamma/métodos , Espectrometría gamma/normas , Simulación por Computador , Internacionalidad , Transferencia Lineal de Energía , Dosis de Radiación
4.
Appl Radiat Isot ; 81: 114-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23582499

RESUMEN

In this work, PENELOPE2008 and MCNP5 software packages were used to investigate the effect of simulation parameters such as cut-off energy of photons and electrons on the detector response function and peak escape intensity to assess their influence on the efficiency determination. The results showed a general agreement between the two codes, however both the intensity of escape peaks and total efficiency computed with PENELOPE2008 are higher than those obtained with MCNP5. Moreover, the calculated efficiencies are typically 8% higher than what is experimentally found in the low energy range. Further investigation was required to obtain better agreement and lead to better estimate of the real germanium crystal dimensions and dead layer.


Asunto(s)
Algoritmos , Artefactos , Radiación Cósmica , Modelos Estadísticos , Método de Montecarlo , Programas Informáticos , Espectrometría gamma/instrumentación , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación
5.
Appl Radiat Isot ; 81: 71-5, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23615361

RESUMEN

In this study, different aspects of the Compton scattering inside volume sources are illustrated using experimental approach and Monte Carlo simulation. For the low-energy range (below 100 keV) scattered events represents around 30% of the whole spectrum. Influence of the source-detector geometry is discussed. The scattering effects induce strong differences in spectrum shape for different geometrical conditions. This should influence efficiency transfer factors. A new approach is proposed, including the scattered events, to avoid complex peak area determination.


Asunto(s)
Modelos Estadísticos , Método de Montecarlo , Radiometría/métodos , Programas Informáticos , Análisis Espectral/métodos , Simulación por Computador , Transferencia de Energía , Fotones , Dispersión de Radiación
6.
Appl Radiat Isot ; 70(9): 2137-40, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22410298

RESUMEN

The numerical calculation of coincidence summing corrections requires both the total and full-energy peak efficiencies to be included in the corrective factors. Moreover, in the case of volume sources, the coincidence probability depends on the position of the photon emission inside the radioactive sample, thus it is necessary to calculate the coincidence summing corrective factors by integrating the elemental contributions for the entire volume. The software ETNA calculates coincidence summing corrective factors according to a deterministic method, for volume sources, two approaches are included in the software: the "simplified" calculation uses directly the efficiency of the volume source like in the case of point source, and the "complete" calculation performs the volume integration. To assess the difference between these, different geometrical cases are tested for several radionuclides using both methods.


Asunto(s)
Algoritmos , Artefactos , Modelos Estadísticos , Radioisótopos/análisis , Radiometría/métodos , Programas Informáticos , Simulación por Computador , Dosis de Radiación
7.
Appl Radiat Isot ; 68(7-8): 1423-7, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20022512

RESUMEN

The activity measurement of beta-plus emitters by gamma-ray spectrometry is studied. Experimental measurements are performed with (22)Na, (65)Zn and (64)Cu with sources included in a lead container. For these nuclides, the activity can be derived both from one photon emission peak and from the 511 keV annihilation peak, including annihilation in-flight correction and geometry correction computed by Monte Carlo simulation. The activity values obtained using the two types of peaks show satisfying agreement. The extension of the method to volume sources is discussed.


Asunto(s)
Partículas beta , Radioisótopos/análisis , Espectrometría gamma/métodos , Cobre/análisis , Métodos , Sodio/análisis , Zinc/análisis
8.
Appl Radiat Isot ; 67(5): 957-60, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19285421

RESUMEN

Gamma-ray spectrometry measurements have been carried out to determine the activity of natural radionuclides in a phosphogypsum sample included in a specific tight container. The gamma spectrometer includes an N-type coaxial high-purity germanium (HPGe) detector equipped with an anti-cosmic system. This measurement required the determination of linear attenuation coefficients of phosphogypsum to calculate self-absorption correction between efficiency calibration conditions and measurement ones. The results are given for the three natural chains and for (40)K, in term of specific activity/g of dry material, ranging from a few Bq kg(-1) to a few hundreds Bq kg(-1). The equilibrium within the different families and the (235)U/(238)U ratio are discussed.


Asunto(s)
Sulfato de Calcio/análisis , Fósforo/análisis , Radioisótopos/análisis , Espectrometría gamma/métodos , Absorción , Calibración , Espectrometría gamma/instrumentación
9.
Appl Radiat Isot ; 60(2-4): 159-65, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14987636

RESUMEN

A tunable monochromatic X-ray source operating in the 1-20 keV energy range is described. An X-ray tube provides initial photons. A dispersive crystal performs the energy selection, according to Bragg's law. An X-ray detector is connected to the monochromator fixed exit. This setup can be used for metrological studies. A first application consists in measuring attenuation coefficients in the 4-10 keV energy range. Results for aluminum and copper are given, with average relative uncertainties (1sigma) of 1% and 3% respectively.


Asunto(s)
Calibración/normas , Análisis de Falla de Equipo , Radiometría/instrumentación , Radiometría/normas , Estándares de Referencia , Transductores , Rayos X , Diseño de Equipo , Dosis de Radiación , Radiometría/métodos , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA