1.
Eur J Transl Myol ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38785351

RESUMEN

Blockchain technology has gained popularity since the invention of Bitcoin in 2008. It offers a decentralized and secure system for managing and protecting data. In the healthcare sector, where data protection and patient privacy are crucial, blockchain has the potential to revolutionize various aspects, including patient data management, orthopedic registries, medical imaging, research data, and the integration of Internet of Things (IoT) devices. This manuscript explores the applications of blockchain in orthopedics and highlights its benefits. Furthermore, the combination of blockchain with artificial intelligence (AI), machine learning, and deep learning can enable more accurate diagnoses and treatment recommendations. AI algorithms can learn from large datasets stored on the blockchain, leading to advancements in automated clinical decision-making. Overall, blockchain technology has the potential to enhance data security, interoperability, and collaboration in orthopedics. While there are challenges to overcome, such as adoption barriers and data sharing willingness, the benefits offered by blockchain make it a promising innovation for the field.

2.
J Pers Med ; 14(4)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38673051

RESUMEN

Bilateral scaphoid fractures are rare lesions, warranting a review to synthesize current knowledge, identify gaps, and suggest research directions. Two authors, adhering to PRISMA guidelines, in January 2024 identified 16 case reports (1976-2023). Data extraction included demographics, injury mechanisms, associated injuries, fracture sites, treatments, and outcomes. Among 121 initial outcomes, 16 articles met the criteria, predominantly affecting young people (93.75% males, mean age 22 years). High-energy traumas (75%) often caused associated wrist injuries (68.75%). Most fractures required surgical intervention (68.75%), primarily headless compression screws. Bilateral scaphoid fractures, which are rare but associated with high-energy traumas, commonly involve wrist injuries. Surgical management is often necessary, yielding better outcomes with fewer complications. Further research is essential to understand the epidemiology, optimal management, and long-term results. Early diagnosis and appropriate treatment are crucial for preventing complications and ensuring favorable patient outcomes.

3.
J Orthop Traumatol ; 24(1): 15, 2023 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-37055638

RESUMEN

BACKGROUND: The functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions. MATERIALS AND METHODS: By means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by ± 3°. RESULTS: The greatest von Mises stress state in the bone component for the 90° working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0° and 145° showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90° (- 3° in the sagittal plane, 0° in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement. CONCLUSION: The areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90°. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.


Asunto(s)
Prótesis de Codo , Humanos , Análisis de Elementos Finitos , Húmero , Cúbito , Cementos para Huesos
4.
Trauma Case Rep ; 44: 100786, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36851906

RESUMEN

Bennet's fracture represents one of the most common injuries of the hand district, involving the base of the thumb, and it is affects children and elderly patients the most. The fracture is caused by direct axial trauma to a partially flexed first metacarpal and it is always intra-articular: the fracture line separates the palmar ulnar aspect of the first metacarpal base from the remaining first metacarpal. The fracture pattern is such that the first metacarpal shaft moves dorsally, proximally, and radially due to the pull of the abductor pollicis longus, extensor pollicis longus, extensor pollicis brevis, and the adductor pollicis brevis, which remain attached to the fracture fragment. The surgical treatment consists of closed reduction with percutaneous pinning or open reduction with either pins or interfragmentary screws. The decision to treat these fractures with either open reduction or closed reduction is still a matter of debate. To the best of our knowledge, there are no cases of bilateral Bennett's fracture reported in literature. The aim of this paper is to present a rare case of bilateral Bennet's fracture, the decision of two different treatments, and the good clinical outcomes.