Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 8205, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589473

RESUMEN

This paper proposes an innovative approach to improve the performance of grid-connected photovoltaic (PV) systems operating in environments with variable atmospheric conditions. The dynamic nature of atmospheric parameters poses challenges for traditional control methods, leading to reduced PV system efficiency and reliability. To address this issue, we introduce a novel integration of fuzzy logic and sliding mode control methodologies. Fuzzy logic enables the PV system to effectively handle imprecise and uncertain atmospheric data, allowing for decision-making based on qualitative inputs and expert knowledge. Sliding mode control, known for its robustness against disturbances and uncertainties, ensures stability and responsiveness under varying atmospheric conditions. Through the integration of these methodologies, our proposed approach offers a comprehensive solution to the complexities posed by real-world atmospheric dynamics. We anticipate applications in grid-connected PV systems across various geographical locations and climates. By harnessing the synergistic benefits of fuzzy logic and sliding mode control, this approach promises to significantly enhance the performance and reliability of grid-connected PV systems in the presence of variable atmospheric conditions. On the grid side, both PSO (Particle Swarm Optimization) and GA (Genetic Algorithm) algorithms were employed to tune the current controller of the PI (Proportional-Integral) current controller (inverter control). Simulation results, conducted using MATLAB Simulink, demonstrate the effectiveness of the proposed hybrid MPPT technique in optimizing the performance of the PV system. The technique exhibits superior tracking efficiency, achieving a convergence time of 0.06 s and an efficiency of 99.86%, and less oscillation than the classical methods. The comparison with other MPPT techniques highlights the advantages of the proposed approach, including higher tracking efficiency and faster response times. The simulation outcomes are analyzed and demonstrate the effectiveness of the proposed control strategies on both sides (the PV array and the grid side). Both PSO and GA offer effective methods for tuning the parameters of a PI current controller. According to considered IEEE standards for low-voltage networks, the total current harmonic distortion values (THD) obtained are considerably high (8.33% and 10.63%, using the PSO and GA algorithms, respectively). Comparative analyses with traditional MPPT methods demonstrate the superior performance of the hybrid approach in terms of tracking efficiency, stability, and rapid response to dynamic changes.

2.
Sci Rep ; 14(1): 6653, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509162

RESUMEN

Integration renewable energy sources into current power generation systems necessitates accurate forecasting to optimize and preserve supply-demand restrictions in the electrical grids. Due to the highly random nature of environmental conditions, accurate prediction of PV power has limitations, particularly on long and short periods. Thus, this research provides a new hybrid model for forecasting short PV power based on the fusing of multi-frequency information of different decomposition techniques that will allow a forecaster to provide reliable forecasts. We evaluate and provide insights into the performance of five multi-scale decomposition algorithms combined with a deep convolution neural network (CNN). Additionally, we compare the suggested combination approach's performance to that of existing forecast models. An exhaustive assessment is carried out using three grid-connected PV power plants in Algeria with a total installed capacity of 73.1 MW. The developed fusing strategy displayed an outstanding forecasting performance. The comparative analysis of the proposed combination method with the stand-alone forecast model and other hybridization techniques proves its superiority in terms of forecasting precision, with an RMSE varying in the range of [0.454-1.54] for the three studied PV stations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...