Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med ; 104: 149-159, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36427487

RESUMEN

PURPOSE: In order to translate the FLASH effect in clinical use and to treat deep tumors, Very High Electron Energy irradiations could represent a valid technique. Here, we address the main issues in the design of a VHEE FLASH machine. We present preliminary results for a compact C-band system aiming to reach a high accelerating gradient and high current necessary to deliver a Ultra High Dose Rate with a beam pulse duration of 3µs. METHODS: The proposed system is composed by low energy high current injector linac followed by a high acceleration gradient structure able to reach 60-160 MeV energy range. To obtain the maximum energy, an energy pulse compressor options is considered. CST code was used to define the specifications RF parameters of the linac. To optimize the accelerated current and therefore the delivered dose, beam dynamics simulations was performed using TSTEP and ASTRA codes. RESULTS: The VHEE parameters Linac suitable to satisfy FLASH criteria were simulated. Preliminary results allow to obtain a maximum energy of 160 MeV, with a peak current of 200 mA, which corresponds to a charge of 600 nC. CONCLUSIONS: A promising preliminary design of VHEE linac for FLASH RT has been performed. Supplementary studies are on going to complete the characterization of the machine and to manufacture and test the RF prototypes.


Asunto(s)
Aceleradores de Partículas
2.
Phys Rev Lett ; 106(14): 144801, 2011 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-21561195

RESUMEN

We report the first experimental implementation of a method based on simultaneous use of an energy chirp in the electron beam and a tapered undulator, for the generation of ultrashort pulses in a self-amplified spontaneous emission mode free-electron laser (SASE FEL). The experiment, performed at the SPARC FEL test facility, demonstrates the possibility of compensating the nominally detrimental effect of the chirp by a proper taper of the undulator gaps. An increase of more than 1 order of magnitude in the pulse energy is observed in comparison to the untapered case, accompanied by FEL spectra where the typical SASE spiking is suppressed.

3.
Phys Rev Lett ; 104(5): 054801, 2010 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-20366769

RESUMEN

In this Letter we report the first experiments aimed at the simultaneous demonstration of the emittance compensation process and velocity bunching in a high brightness electron source, the SPARC photoinjector in INFN-LNF. While a maximum compression ratio up to a factor 14 has been observed, in a particular case of interest a compression factor of 3, yielding a slice current of 120 A with less than 2 microm slice emittance, has been measured. This technique may be crucial in achieving high brightness beams in photoinjectors aiming at optimized performance of short wavelength single-pass free electron lasers or other advanced applications in laser-plasma accelerators.

4.
Phys Rev Lett ; 99(23): 234801, 2007 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-18233375

RESUMEN

In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA