Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 310
Filtrar
2.
POCUS J ; 8(1): 71-80, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37152333

RESUMEN

Background: Point of care ultrasound (POCUS) is ubiquitous in the modern emergency department (ED). POCUS can be helpful in the management of patients with sepsis in many ways including determining the cause of sepsis, assessing fluid status, guiding resuscitation, and performing procedures. However, the frequency and manner in which POCUS is incorporated into the care of septic patients in community emergency medicine remains unclear. Objective: To evaluate POCUS frequency and exam types used in the care of patients with sepsis in two community EDs in Southern California. Methods: We performed a retrospective analysis of 5,264 ED visits with a diagnosis of sepsis at two community emergency departments between January 2014 and December 2018. Patients 18 years or older who were diagnosed with sepsis and had either lactate ≥ 4 mmol, a documented mean arterial pressure (MAP) < 65 mmHg, or a systolic blood pressure (SBP) < 90 mmHg were included. Charts were reviewed to determine if POCUS was used during the ED evaluation. Primary outcomes were frequency of POCUS use in the cohort, change in POCUS use over the study period, and the types of exams performed. Results: POCUS was used in 21% of encounters meeting inclusion criteria and was positively correlated with ED arrival year (OR = 1.09; CI 1.04, 1.15; p=0.001). The most common POCUS exam was ultrasound-guided central line placement, with the next most common exams being cardiac, followed by inferior vena cava (IVC). Only the frequency of cardiac, IVC, lung and Focused Assessment with Sonography in Trauma (FAST) exams were found to increase significantly over the study period. Conclusions: Total POCUS use increased significantly in this cohort of septic patients over the study period due to more cardiac, IVC, lung and FAST exams being performed.

3.
BMC Med Educ ; 22(1): 614, 2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-35953840

RESUMEN

BACKGROUND: 3D printed models are becoming increasingly popular in healthcare as visual and tactile tools to enhance understanding of anatomy and pathology in medical trainee education, provide procedural simulation training, and guide surgical procedures. Patient-specific 3D models are currently being used preoperatively for trainee medical education in planning surgical approaches and intraoperatively to guide decision-making in several specialties. Our study group utilized a modified Delphi process to create a standardized assessment for trainees using patient-specific 3D models as a tool in medical education during pre-surgical planning. METHODS: A literature review was conducted to identify survey questions administered to clinicians in published surgical planning studies regarding the use of patient-specific 3D models. A core study team reviewed these questions, removed duplicates, categorized them, mapped them to overarching themes, and, where applicable, modified individual questions into a form generalizable across surgical specialties. The core study panel included a physician, physician-scientist, social scientist, engineer/medical student, and 3D printing lab manager. A modified Delphi process was then used to solicit feedback on the clarity and relevance of the individual questions from an expert panel consisting of 12 physicians from specialties including anesthesiology, emergency medicine, radiology, urology, otolaryngology, and obstetrics/gynecology. When the Radiological Society of North America (RSNA)/American College of Radiology (ACR) 3D Printing Registry Data Dictionary was released, additional survey questions were reviewed. A final cross-disciplinary survey of the utility of 3D printed models in surgical planning medical education was developed. RESULTS: The literature review identified 100 questions previously published in surveys assessing patient-specific 3D models for surgical planning. Following the review, generalization, and mapping of survey questions from these studies, a list of 24 questions was generated for review by the expert study team. Five additional questions were identified in the RSNA/ACR 3D Printing Registry Data Dictionary and included for review. A final questionnaire consisting of 20 questions was developed. CONCLUSIONS: As 3D printed models become more common in medical education, the need for standardized assessment is increasingly essential. The standardized questionnaire developed in this study reflects the interests of a variety of stakeholders in patient-specific 3D models across disciplines.


Asunto(s)
Modelos Anatómicos , Médicos , Retroalimentación , Humanos , Impresión Tridimensional , Encuestas y Cuestionarios
4.
J Med Educ Curric Dev ; 9: 23821205221080701, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35237722

RESUMEN

PROBLEM: Health systems science (HSS) curricula in medical schools facilitate an understanding of social determinants of health (SDOH) and their impact on health outcomes. After implementation of an experiential, patient-centered program based around SDOH screening, however, our medical college noted poor student receptivity and engagement. In order to improve the program, we chose a design thinking approach based on the perceived value of actively engaging learners in the design of education. The role of design thinking in curricular quality improvement, however, remains unclear. INTERVENTION: We sought to determine if a current educational model for SDOH screening could be improved by reforming the curriculum using a design thinking workshop involving student and faculty stakeholders. CONTEXT: The current study is a retrospective analysis of first-year medical student, end-of-year evaluations of the Clinical Experience (CE) program at the Sidney Kimmel Medical College before (2018-19) and after (2019-20) implementation of the design thinking workshop and subsequent curriculum changes. IMPACT: Overall positive results significantly increased across all survey questions after the curricular intervention (p < 0.01), indicating increased student satisfaction with the revised curriculum. LESSONS LEARNED: Few studies assess outcomes of design thinking-driven curricular changes. The current study of an SDOH screening program details the implementation of initiatives that originated from a design thinking sprint and assesses program evaluations following these curricular changes. Most of the well-received curricular changes concerned improvements in student training, patient screening and follow-up, and the leveraging of existing technology. The study reinforces the importance of co-creation among stakeholders when redesigning medical curricula.

5.
Acad Emerg Med ; 28(10): 1142-1149, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34425044

RESUMEN

OBJECTIVE: This study seeks to evaluate the test characteristics of D-dimer for pulmonary embolism (PE) in patients with a concurrent diagnosis of COVID-19. We hypothesized that the sensitivity of D-dimer for PE at current institutional cut points would be similar to those without COVID-19. METHODS: This is a multicenter retrospective observational cohort study across five urban and suburban EDs in the same health care system. The electronic health record was queried for all computed tomography pulmonary angiography (CTPA) studies from December 1, 2019, to October 22, 2020. All ED patients who underwent CTPA had D-dimer and COVID-19 testing completed in a single encounter were included in the study. Baseline demographics were obtained. Test characteristics of D-dimer for PE were calculated for patients with and without COVID-19. Additionally, receiver operator characteristics (ROC) curves were constructed for two different D-dimer assays. RESULTS: There were 1158 patient encounters that met criteria for analysis. Performance of D-dimer testing for PE was similar between COVID-19-positive and -negative patients. In COVID-19-positive patients, the sensitivity was 100% (95% confidence interval [CI] = 87.6%-100%), specificity was 11.9% (95% CI = 7.9%-17.1%), and negative predictive value (NPV) was 100%. In COVID-19-negative patients the sensitivity was 97.6% (95% CI = 91.5%-99.7%), specificity was 14.4% (95% CI = 12.1%-17%), and NPV was 98.3% (95% CI = 93.8%-99.6%). For assay 1 the area under the curve (AUC) for COVID-19-positive patients was 0.76 (95% CI = 0.68-0.83), and for COVID-19-negative patients, 0.73 (95% CI = 0.69-0.77). For assay 2, AUC for COVID-19-positive patients was 0.85 (95% CI = 0.77-0.92), and for COVID-19-negative patients, 0.80 (95% CI = 0.77-0.84). Inspection of the ROC curve for assay 1 revealed that 100% sensitivity was maintained up to a threshold of 0.67 FEU (fibrinogen equivalent units; from 0.50 FEU) with an increase in specificity to 29% (from 18.7%), and for assay 2, 100% sensitivity was maintained up to a threshold of 662 D-dimer units (DDU; from 230 DDU) with an increased specificity to 59% (from 6.1%). CONCLUSION: Results from this multicenter retrospective study did not find a significant difference in sensitivity of D-dimer for PE due to concomitant COVID-19 infection. Further study is required to determine if PE can safely be excluded based on D-dimer results alone in patients with suspected or proven COVID-19 or if adjusted D-dimer levels could have a role in management.


Asunto(s)
COVID-19 , Embolia Pulmonar , Prueba de COVID-19 , Productos de Degradación de Fibrina-Fibrinógeno , Humanos , Valor Predictivo de las Pruebas , Embolia Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2 , Sensibilidad y Especificidad
6.
J Ultrasound Med ; 40(4): 857, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32833252
7.
J Emerg Med ; 59(3): 403-408, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32712031

RESUMEN

BACKGROUND: The novel coronavirus SARS-CoV-2 has caused a pandemic, overwhelming health care systems around the world. Hospitals around the world, including the United States, have been struggling to adapt to the influx of patients with COVID-19, the illness caused by SARS-CoV2, given limited resources and high demand for medical care. OBJECTIVES: This article seeks to provide emergency physicians with a guide to sonographic findings in COVID-19 and an algorithm by which point-of-care lung ultrasound may assist emergency physicians caring for these patients during the SARS-CoV-2 pandemic. DISCUSSION: The studies currently being published have established a typical set of ultrasound findings in COVID-19. Point-of-care lung ultrasound is rapid and accessible in most emergency departments in the United States, and even in many resource-poor settings. CONCLUSION: Point-of-care ultrasound provides numerous benefits to emergency providers caring for patients with COVID-19, including decreasing resource utilization, assisting in diagnosis, guiding management of the critically ill patient, and aiding in rapid triage of patients under investigations for COVID-19.


Asunto(s)
Infecciones por Coronavirus/diagnóstico por imagen , Infecciones por Coronavirus/epidemiología , Servicio de Urgencia en Hospital/organización & administración , Neumonía Viral/diagnóstico por imagen , Neumonía Viral/epidemiología , Sistemas de Atención de Punto/organización & administración , Síndrome Respiratorio Agudo Grave/diagnóstico por imagen , Ultrasonografía Doppler/estadística & datos numéricos , COVID-19 , Atención a la Salud/organización & administración , Transmisión de Enfermedad Infecciosa/prevención & control , Femenino , Humanos , Control de Infecciones/métodos , Masculino , Salud Laboral , Pandemias/prevención & control , Pandemias/estadística & datos numéricos , Seguridad del Paciente , Síndrome Respiratorio Agudo Grave/epidemiología , Síndrome Respiratorio Agudo Grave/fisiopatología , Ultrasonografía Doppler/métodos
8.
J Emerg Nurs ; 46(4): 440-448, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32507726

RESUMEN

INTRODUCTION: The physical layout of the emergency department affects the way in which patients and providers move within the space and can cause substantial changes in workflow and, therefore, affect communication patterns between providers. There is no 1 ED design that enables the best patient care, and quantitative studies looking at ED design are limited. The goal of this study was to examine how different ED designs, centralized and decentralized, are associated with communication patterns among health care professionals. METHODS: A task performance, direct observation time study was used. By developing a novel tablet-based digital mapping tool using a cloud-based mapping platform (ArcGIS), data on provider actions and interactions were collected and mapped to a precise location within the emergency department throughout an entire nursing shift. RESULTS: The difference in the duration of nurse-physician interactions between the 2 ED designs was statistically significant. Within the centralized design, nurse-physician interactions totaled 14 minutes and 38 seconds compared with 30 minutes and 11 seconds in the decentralized design (t = 2.31, P = 0.02). More conversations between nurses and physicians occurred inside the patient's room in the decentralized design. DISCUSSION: Our findings suggest that the ED design affects communication patterns among health care providers and that the design has the potential to affect the quality of patient care.


Asunto(s)
Entorno Construido , Servicio de Urgencia en Hospital , Comunicación Interdisciplinaria , Personal de Enfermería en Hospital , Adulto , Femenino , Hospitales de Enseñanza , Humanos , Masculino , Análisis y Desempeño de Tareas , Factores de Tiempo , Estudios de Tiempo y Movimiento , Estados Unidos
9.
J Ultrasound Med ; 39(10): 1965-1976, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32314817

RESUMEN

OBJECTIVES: To perform a systematic review of the accuracy of carotid ultrasound measures in determining volume responsiveness in adults. METHODS: We conducted a systematic review of Ovid MEDLINE and Scopus from conception until January 1, 2019. Two independent reviewers used an iterative process to identify relevant articles and abstract information from them. The quality and risk of bias were assessed with the Quality Assessment of Diagnostic Accuracy Studies version 2 tool. RESULTS: We identified 17 relevant articles with 956 patients. The 2 most frequently cited carotid measures of fluid responsiveness were corrected flow time and peak velocity or change in peak velocity with respiration (ΔCDPV). Accordingly, the diagnostic characteristics of corrected flow time in these studies varied widely, with sensitivities from 60% to 73%, specificities from 82% to 92%, and areas under the receiver operating characteristic curves from 0.75 to 0.88. Optimal cutoff values for ΔCDPV ranged from 9.1% to 14%, with areas under the receiver operating characteristic curves from 0.81 to 0.91, sensitivities from 73% to 86%, and specificities from 78% to 86%. Other measures, such as carotid blood flow and carotid diameter, had limited data to support their use. Heterogeneity of the studies prohibited a meta-analysis. Most studies had a moderate risk of bias and high applicability. CONCLUSIONS: Preliminary research suggests that carotid ultrasound measures may be useful adjunct measures of fluid status; however, they should not be interpreted as absolute and should be placed in a clinical context. The most well-defined and supported measure currently is ΔCDPV, with cutoffs from 9% to 14%. Corrected flow time shows promise, because of heterogeneity of how this value is measured, an optimal cutoff has not been established.


Asunto(s)
Arterias Carótidas , Fluidoterapia , Adulto , Velocidad del Flujo Sanguíneo , Arterias Carótidas/diagnóstico por imagen , Hemodinámica , Humanos , Ultrasonografía
10.
Alzheimers Dement ; 16(1): 60-70, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31914226

RESUMEN

INTRODUCTION: Behavioral variant frontotemporal dementia (bvFTD) may present sporadically or due to an autosomal dominant mutation. Characterization of both forms will improve understanding of the generalizability of assessments and treatments. METHODS: A total of 135 sporadic (s-bvFTD; mean age 63.3 years; 34% female) and 99 familial (f-bvFTD; mean age 59.9; 48% female) bvFTD participants were identified. f-bvFTD cases included 43 with known or presumed chromosome 9 open reading frame 72 (C9orf72) gene expansions, 28 with known or presumed microtubule-associated protein tau (MAPT) mutations, 14 with known progranulin (GRN) mutations, and 14 with a strong family history of FTD but no identified mutation. RESULTS: Participants with f-bvFTD were younger and had earlier age at onset. s-bvFTD had higher total Neuropsychiatric Inventory Questionnaire (NPI-Q) scores due to more frequent endorsement of depression and irritability. DISCUSSION: f-bvFTD and s-bvFTD cases are clinically similar, suggesting the generalizability of novel biomarkers, therapies, and clinical tools developed in either form to the other.


Asunto(s)
Demencia Frontotemporal , Predisposición Genética a la Enfermedad , Mutación/genética , Pruebas Neuropsicológicas/estadística & datos numéricos , Factores de Edad , Anciano , Encéfalo/patología , Proteína C9orf72/genética , Femenino , Demencia Frontotemporal/clasificación , Demencia Frontotemporal/genética , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Progranulinas/genética , Proteínas tau/genética
11.
Alzheimers Dement ; 16(1): 91-105, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31914227

RESUMEN

INTRODUCTION: Leisure activities impact brain aging and may be prevention targets. We characterized how physical and cognitive activities relate to brain health for the first time in autosomal dominant frontotemporal lobar degeneration (FTLD). METHODS: A total of 105 mutation carriers (C9orf72/MAPT/GRN) and 69 non-carriers reported current physical and cognitive activities at baseline, and completed longitudinal neurobehavioral assessments and brain magnetic resonance imaging (MRI) scans. RESULTS: Greater physical and cognitive activities were each associated with an estimated >55% slower clinical decline per year among dominant gene carriers. There was also an interaction between leisure activities and frontotemporal atrophy on cognition in mutation carriers. High-activity carriers with frontotemporal atrophy (-1 standard deviation/year) demonstrated >two-fold better cognitive performances per year compared to their less active peers with comparable atrophy rates. DISCUSSION: Active lifestyles were associated with less functional decline and moderated brain-to-behavior relationships longitudinally. More active carriers "outperformed" brain volume, commensurate with a cognitive reserve hypothesis. Lifestyle may confer clinical resilience, even in autosomal dominant FTLD.


Asunto(s)
Cognición/fisiología , Ejercicio Físico , Degeneración Lobar Frontotemporal , Actividades Recreativas , Pruebas Neuropsicológicas/estadística & datos numéricos , Anciano , Atrofia/patología , Femenino , Degeneración Lobar Frontotemporal/genética , Degeneración Lobar Frontotemporal/patología , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
14.
J Ultrasound Med ; 37(11): 2667-2679, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29708268

RESUMEN

OBJECTIVES: The purpose of this study was to conduct a systematic review of the evidence of educational outcomes associated with teaching ultrasonography (US) to medical students. METHODS: A review of databases through 2016 was conducted for research studies that reported data on teaching US to medical students. Each title and abstract were reviewed by teams of 2 independent abstractors to determine whether the article would be ordered for full-text review and subsequently by 2 independent authors for inclusion. Data were abstracted with a form developed a priori by the authors. RESULTS: Ninety-five relevant unique articles were included (of 6936 identified in the databases). Survey data showed that students enjoyed the US courses and desired more US training. Of the studies that assessed US-related knowledge and skill, most of the results were either positive (16 of 25 for knowledge and 24 of 58 for skill) or lacked a control (8 of 25 for knowledge and 27 of 58 for skill). The limited evidence (14 of 95 studies) of the effect of US training on non-US knowledge and skill (eg, anatomy knowledge or physical examination skill) was mixed. CONCLUSIONS: There is ample evidence that students can learn US knowledge and skills and that they enjoy and want US training in medical school. The evidence for the effect of US on external outcomes is limited, and there is insufficient evidence to recommend it for this purpose at this time.


Asunto(s)
Competencia Clínica , Curriculum , Educación de Pregrado en Medicina/métodos , Ultrasonido/educación , Humanos , Ultrasonografía
17.
J Dairy Sci ; 100(9): 7246-7261, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28711247

RESUMEN

Little is known about the bovine milk proteome or whether it can be affected by diet. The objective of this study was to determine if the dietary rumen degradable protein (RDP):rumen undegradable protein (RUP) ratio could alter the bovine milk proteome. Six Holstein cows (parity: 2.5 ± 0.8) in mid lactation were blocked by days in milk (80 ± 43 d in milk) and milk yield (57.5 ± 6.0 kg) and randomly assigned to treatment groups. The experiment was conducted as a double-crossover design consisting of three 21-d periods. Within each period, treatment groups received diets with either (1) a high RDP:RUP ratio (RDP treatment: 62.4:37.6% of crude protein) or (2) a low RDP:RUP ratio (RUP treatment: 51.3:48.7% of crude protein). Both diets were isonitrogenous and isoenergetic (crude protein: 18.5%, net energy for lactation: 1.8 Mcal/kg of dry matter). To confirm N and energy status of cows, dry matter intake was determined daily, rumen fluid samples were collected for volatile fatty acid analysis, blood samples were collected for plasma glucose, ß-hydroxybutyrate, urea nitrogen, and fatty acid analysis, and total 24-h urine and fecal samples were collected for N analysis. Milk samples were collected to determine the general milk composition and the protein profile. Milk samples collected for high-abundance protein analysis were subjected to HPLC analysis to determine the content of α-casein, ß-casein, and κ-casein, as well as α-lactalbumin and ß-lactoglobulin. Samples collected for low-abundance protein analysis were fractionated, enriched using ProteoMiner treatment, and separated using sodium dodecyl sulfate-PAGE. After excision and digestion, the peptides were analyzed using liquid chromatography (LC) tandem mass spectrometry (MS/MS). The LC-MS/MS data were analyzed using PROC GLIMMIX of SAS (version 9.4, SAS Institute Inc., Cary, NC) and adjusted using the MULTTEST procedure. All other parameters were analyzed using PROC MIXED of SAS. No treatment differences were observed in dry matter intake, milk yield, general milk composition, plasma parameters, or rumen volatile fatty acid concentrations, indicating no shift in total energy or protein available. Milk urea N and plasma urea N concentrations were higher in the RDP group, indicating some shift in N partitioning due to diet. A total of 595 milk proteins were identified, with 83% of these proteins known to be involved in cellular processes. Although none of the low-abundance proteins identified by LC-MS/MS were affected by diet, feeding a diet high in RUP decreased ß-casein, κ-casein, and total milk casein concentration. Further investigations of the interactions between diet and the milk protein profile are needed to manipulate the milk proteome using diet.


Asunto(s)
Proteínas en la Dieta/metabolismo , Lactancia , Proteínas de la Leche/metabolismo , Nitrógeno/metabolismo , Proteoma/metabolismo , Rumen/metabolismo , Animales , Bovinos , Femenino , Embarazo , Distribución Aleatoria , Espectrometría de Masas en Tándem
18.
Acad Emerg Med ; 24(9): 1124-1136, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28464459

RESUMEN

BACKGROUND: The use of ultrasonography (US) to diagnose appendicitis is well established. More recently, point-of-care ultrasonography (POCUS) has also been studied for the diagnosis of appendicitis, which may also prove a valuable diagnostic tool. The purpose of this study was through systematic review and meta-analysis to identify the test characteristics of POCUS, specifically US performed by a nonradiologist physician, in accurately diagnosing acute appendicitis in patients of any age. METHODS: We conducted a thorough and systematic literature search of English language articles published on point-of-care, physician-performed transabdominal US used for the diagnosis of acute appendicitis from 1980 to May, 2015 using OVID MEDLINE In-Process & Other Non-indexed Citations and Scopus. Studies were selected and subsequently independently abstracted by two trained reviewers. A random-effects pooled analysis was used to construct a hierarchical summary receiver operator characteristic curve, and a meta-regression was performed. Quality of studies was assessed using the QUADAS-2 tool. RESULTS: Our search yielded 5,792 unique studies and we included 21 of these in our final review. Prevalence of disease in this study was 29.8%, (range = 6.4%-75.4%). The sensitivity and specificity for POCUS in diagnosing appendicitis were 91% (95% confidence interval [CI] = 83%-96%) and 97% (95% CI = 91%-99%), respectively. The positive and negative predictive values were 91 and 94%, respectively. Studies performed by emergency physicians had slightly lower test characteristics (sensitivity = 80%, specificity = 92%). There was significant heterogeneity between studies (I2 = 99%, 95% CI = 99%-100%) and the quality of the reported studies was moderate, mostly due to unclear reporting of blinding of physicians and timing of scanning and patient enrollment. Several of the studies were performed by a single operator, and the education and training of the operators were variably reported. CONCLUSION: Point-of-care US has relatively high sensitivity and specificity for diagnosing acute appendicitis, although the data presented are limited by the quality of the original studies and large CIs. In the hands of an experienced operator, POCUS is an appropriate initial imaging modality for diagnosing appendicitis. Based on our results, it is premature to utilize POCUS as a stand-alone test or to rule out appendicitis.


Asunto(s)
Apendicitis/diagnóstico por imagen , Sistemas de Atención de Punto/normas , Ultrasonografía/normas , Enfermedad Aguda , Humanos , Curva ROC , Sensibilidad y Especificidad , Ultrasonografía/métodos
19.
J Am Soc Echocardiogr ; 30(7): 714-723.e4, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28495379

RESUMEN

OBJECTIVE: Pulmonary embolism (PE) is a common diagnosis with significant mortality if not appropriately treated. The use of transthoracic echocardiography in patients with PE is common; however, its diagnostic capabilities in this use are unclear. With the increased use of ultrasonography in medical settings, it is important to understand the strengths and limitations of echocardiography for the diagnosis of PE. METHODS: We conducted a systematic review of PubMed, CINAHL, and EMBASE through 2016 for articles assessing the diagnostic accuracy of transthoracic echocardiography for PE. Two authors independently abstracted relevant data from the studies. We assessed quality using the QUADAS-2 tool for diagnostic studies. RESULTS: Undefined "right heart strain" was the most common sign used, and it had a sensitivity of 53% (95% CI, 45%-61%) and a specificity of 83% (95% CI, 74%-90%). Eleven other distinct signs were identified: ventricle size ratio, abnormal septal motion, tricuspid regurgitation, 60/60 sign, McConnell's sign, right heart thrombus, right ventricle hypokinesis, pulmonary hypertension, right ventricular end-diastolic diameter, tricuspid annular plane systolic excursion, and right ventricular systolic pressure. CONCLUSIONS: Studies show a consistently high specificity and low sensitivity for echocardiography in the diagnosis of PE, making it potentially adequate as a rule-in test at the bedside in critical care settings such as the emergency department and intensive care unit for patients with a suspicion of PE, especially those unable to get other confirmatory studies. Future research may continue to clarify the role of bedside echocardiography in conjunction with other tests and imaging in the overall management of PE.


Asunto(s)
Ecocardiografía/métodos , Embolia Pulmonar/diagnóstico por imagen , Diagnóstico Diferencial , Humanos
20.
Physiol Genomics ; 49(3): 141-150, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28087756

RESUMEN

Muscle fiber cross-sectional area (CSA) and proportion of different fiber types are important determinants of muscle function and overall metabolism. Genetic variation plays a substantial role in phenotypic variation of these traits; however, the underlying genes remain poorly understood. This study aimed to map quantitative trait loci (QTL) affecting differences in soleus muscle fiber traits between the LG/J and SM/J mouse strains. Fiber number, CSA, and proportion of oxidative type I fibers were assessed in the soleus of 334 genotyped female and male mice of the F34 generation of advanced intercross lines (AIL) derived from the LG/J and SM/J strains. To increase the QTL detection power, these data were combined with 94 soleus samples from the F2 intercross of the same strains. Transcriptome of the soleus muscle of LG/J and SM/J females was analyzed by microarray. Genome-wide association analysis mapped four QTL (genome-wide P < 0.05) affecting the properties of muscle fibers to chromosome 2, 3, 4, and 11. A 1.5-LOD QTL support interval ranged between 2.36 and 4.67 Mb. On the basis of the genomic sequence information and functional and transcriptome data, we identified candidate genes for each of these QTL. The combination of analyses in F2 and F34 AIL populations with transcriptome and genomic sequence data in the parental strains is an effective strategy for refining QTL and nomination of the candidate genes.


Asunto(s)
Fibras Musculares Esqueléticas/metabolismo , Músculo Esquelético/metabolismo , Mapeo Físico de Cromosoma , Animales , Cromosomas de los Mamíferos/genética , Cruzamientos Genéticos , Femenino , Regulación de la Expresión Génica , Estudios de Asociación Genética , Genómica , Masculino , Ratones , Fenotipo , Sitios de Carácter Cuantitativo/genética , Caracteres Sexuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA