Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Physiol Meas ; 45(6)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38838705

RESUMEN

Objective. To compare the acute physiological and perceptual responses to blood flow restriction (BFR) exercise using a traditional research device or novel, automated system.Methods. Forty-four resistance trained individuals performed four sets of unilateral elbow flexion exercise (30% one-repetition maximum) to volitional failure using two distinct restrictive devices [SmartCuffs PRO BFR Model (SMARTCUFF), Hokanson E20 Rapid Inflation device (HOKANSON)] and with two levels of BFR [40% limb occlusion pressure (LOP), 80% LOP]. Blood pressure (BP), muscle thickness (MT), and isometric strength (ISO) were assessed prior to and following exercise. Perceptual responses [ratings of perceived exertion (RPE), discomfort] were assessed prior to exercise and following each exercise set.Main results. Data are displayed as means (SD). Immediately following exercise with 40% LOP, there were no statistical differences between devices for BP, MT, and ISO. However, only following Set 1 of exercise, RPE was greater with SMARTCUFF compared to HOKANSON (p< 0.05). In addition, only following Set 2 of exercise, discomfort was greater with HOKANSON compared to SMARTCUFF (p< 0.001). Immediately following exercise with 80% LOP, there were no statistical differences between devices for BP, MT, and ISO. However, only following Set 4 of exercise, RPE was greater with HOKANSON compared to SMARTCUFF (p< 0.05). In addition, following all exercise sets, discomfort was greater with HOKANSON compared to SMARTCUFF (p< 0.001). For repetitions completed with 40% LOP there were no statistical differences between SMARTCUFF and HOKANSON across any exercise sets. For repetitions completed with 80% LOP there were no statistical differences between SMARTCUFF and HOKANSON across Set 1 of exercise (p= 0.34), however, for Sets 2-4 of exercise, significantly greater number of repetitions were completed during SMARTCUFF than HOKANSON.Significance. The present study provides valuable insight into the efficacy of a novel, automated BFR system (SMARTCUFF) eliciting comparable acute physiological responses to BFR exercise and in some cases favorable perceptual responses when compared to a traditional research device (HOKANSON).


Asunto(s)
Automatización , Ejercicio Físico , Percepción , Flujo Sanguíneo Regional , Humanos , Masculino , Femenino , Ejercicio Físico/fisiología , Flujo Sanguíneo Regional/fisiología , Percepción/fisiología , Adulto Joven , Adulto , Presión Sanguínea/fisiología , Entrenamiento de Fuerza/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA