Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
2.
Pathogens ; 12(8)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37623943

RESUMEN

The present retrospective study analyzed the characteristics of strongyloidiasis in patients who were diagnosed at the Outpatient Clinic of the Department of Parasitology-Mycology, Toulouse, France. Sixty-nine file records were included in the study on the basis of a positive stool examination that used Baermann's method. The prominent epidemiological findings were the presence of former immigrants from Italy or Portugal, veterans from the 1st Indochina war, and autochthonous cases. Almost 1/4 of the patients were asymptomatic. Manifestations of skin allergy were the main clinical feature. Blood eosinophilia was present in 76.8% of the patients, and serum total IgE was ≥150 kIU/L in 79.7%. Immunodiagnosis was achieved from 1990 to 2001 by indirect immunofluorescence (IFAT) that was then replaced with ELISA, both methods using Strongyloides ratti filariform larvae. ELISA was found to be similar to IFAT in terms of specificity but exhibited a greater sensitivity. Patients were primarily treated with albendazole or ivermectin beginning in 1993. Forty-eight patients attended the follow-up consultation. Kinetics of the clinical picture and blood eosinophilia were found to be the most convenient parameters to assess the efficacy of anthelmintic therapy. In conclusion, strongyloidiasis remains a neglected disease in Southwestern France. The resolution of clinical features along with the kinetics of eosinophilia appeared to be the most appropriate parameters to check during the posttreatment follow-up.

3.
Pathogens ; 12(7)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37513736

RESUMEN

OBJECTIVES: We aimed to assess the performance of the Novodiag® Stool Parasites (NSP) assay in the diagnosis of the most common intestinal protozoan and microsporidia infections. METHODS: A panel of 167 selected stool samples was retrospectively analysed with the NSP assay and compared to routine microscopy and qPCR methods for the detection of pathogenic protozoa and microsporidia. RESULTS: Whereas specificity was high for all protozoa and microsporidia, NSP sensitivity was strongly dependent on the comparative method used as reference. When compared to microscopic methods, NSP sensitivity was high (96.7 to 100%) for Blastocystis hominis, Entamoeba histolytica and Cyclospora cayetanensis but was lower for Giardia intestinalis (85.2%) and ≤50% for Cystoisospora belli and Dientamoeba fragilis. In comparison to conventional qPCR, the NSP assay demonstrated lower sensitivity characteristics dependent on parasite loads, reaching 60 to 70% for G. intestinalis, D. fragilis, Cryptosporidium spp. and E. histolytica. Sensitivity was 100% for Enterocytozoon bieneusi, but none of the five samples containing Encephalitozoon spp. were detected. CONCLUSIONS: The overall performance of the NSP assay in the diagnosis of gastrointestinal protozoa and microsporidia seems to be better than or equivalent to that observed with microscopic methods but inferior to that obtainable with classical targeted qPCR.

4.
J Mycol Med ; 33(1): 101325, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36270214

RESUMEN

Invasive mould infections are life-threatening and mainly occur in immunocompromised patients. Whereas aspergillosis is described during haemophagocytic lymphohistiocytosis (HLH), only a few cases of concomitant mucormycosis with HLH have been reported. Here, we present an uncommon coinfection of mucormycosis and aspergillosis associated with HLH probably due to a varicella zoster virus (VZV) viraemia which was unresponsive to triple antifungal therapy (liposomal amphotericin B combined with isavuconazole and caspofungin). A review of the cases of mucormycosis with HLH showed that this uncommon association was always lethal and underscored the relevance of screening for mould infections in patients with HLH.


Asunto(s)
Aspergilosis , Coinfección , Linfohistiocitosis Hemofagocítica , Mucormicosis , Humanos , Mucormicosis/complicaciones , Mucormicosis/diagnóstico , Mucormicosis/tratamiento farmacológico , Antifúngicos/uso terapéutico , Coinfección/complicaciones , Coinfección/diagnóstico , Coinfección/tratamiento farmacológico , Linfohistiocitosis Hemofagocítica/complicaciones , Linfohistiocitosis Hemofagocítica/diagnóstico , Linfohistiocitosis Hemofagocítica/tratamiento farmacológico , Aspergilosis/complicaciones , Aspergilosis/diagnóstico , Aspergilosis/tratamiento farmacológico , Hongos
5.
Pathogens ; 11(7)2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35890057

RESUMEN

In the Department of Parasitology and Mycology of Toulouse University Hospitals, patients presenting with common/covert toxocariasis were treated either with albendazole (39 cases) or with diethylcarbamazine (32 cases). Albendazole (ABZ) was given at 10 mg/kg b/w daily for 14 days, and diethylcarbamazine (DEC) was given at 4 mg/kg b/w daily for 21 days. In both groups, follow-up consultations occurred approximately 48 days after the end of the anthelmintic therapy. ABZ and DEC displayed a similar efficacy on the kinetics of the clinical picture (-64.5% of reduction vs. -72.7%, respectively) and on the levels of blood eosinophilia, serum eosinophil cationic protein and serum total IgE. However, the effect of the medication on the laboratory parameters was moderate. The rate of adverse reactions was similar in both groups (38% for ABZ vs. 31% for DEC), but DEC-treated patients complained of more intense and long-lasting side effects. The DEC group had more major adverse reactions, resulting in the termination of the anthelmintic treatment. The results from this retrospective study bring further arguments for considering ABZ, given at 10 mg/kg daily for 2 weeks, as the drug of choice in the treatment of human toxocariasis.

6.
J Clin Microbiol ; 60(5): e0011522, 2022 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-35491823

RESUMEN

For postnatal diagnosis of congenital toxoplasmosis (CT), the gold standard for the detection of anti-Toxoplasma IgM in newborns relies on the immunosorbent agglutination assay (ISAGA), which is manufactured from whole Toxoplasma parasites that become difficult to maintain. For IgG, only the Platelia assay provides a validated assay for cord blood according to the manufacturer, allowing its use in this context. We compared the analytical performance of four commercialized automated assays, Platelia, Abbott, Vidas, and Liaison, for the detection of IgG and IgM in the cord blood or peripheral blood of newborns from women infected during pregnancy. The assays were performed on samples from 509 newborns, collected from the university hospitals of Montpellier, Nîmes, and Toulouse. For IgM, the four assays appeared to be sufficiently informative to be used for congenital toxoplasmosis diagnosis (area under the curve [AUC] > 0.8, receiver operating characteristic [ROC] analysis), with Platelia showing the best performance, similar to ISAGA with regard to accuracy (83%). For the Vidas (76%), Abbott (75%), and Liaison (74%) assays, the accuracy was significantly lower. Maternal treatment significantly decreased the sensitivity of all the assays. For IgG, the four evaluated assays showed a sensitivity of over 90%, with Abbott (95%) and Liaison (94%), exhibiting a significantly higher sensitivity than Platelia (90%). Furthermore, Abbott showed its superiority in the cases of maternal infection during the third trimester. In the context of the newborns of mothers infected by Toxoplasma gondii during pregnancy, to ensure efficient care, Platelia and Abbott seemed to be the most suitable reference tests for the detection of IgM for the former and IgG for the latter.


Asunto(s)
Complicaciones Parasitarias del Embarazo , Toxoplasma , Toxoplasmosis Congénita , Toxoplasmosis , Anticuerpos Antiprotozoarios , Femenino , Humanos , Inmunoglobulina G , Inmunoglobulina M , Recién Nacido , Embarazo , Complicaciones Parasitarias del Embarazo/diagnóstico , Toxoplasmosis/diagnóstico , Toxoplasmosis Congénita/diagnóstico
7.
J Clin Microbiol ; 60(5): e0011622, 2022 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-35491840

RESUMEN

The diagnostic accuracy of a commercial Toxoplasma gondii IgA antibody enzyme-linked immunosorbent assay (ELISA) was evaluated in the context of routine practice on 289 newborns with congenital toxoplasmosis (CT) and 220 healthy controls. The performance of this assay was compared to that of the current gold-standard test for anti-Toxoplasma IgM detection, an immunosorbent agglutination assay (ISAGA). IgM and IgA sensitivity and specificity were assessed in cord and postnatal samples. The sensitivity of IgA detection by ELISA on all serum and peripheral blood samples was 60.56% and 56.52%, respectively, which is low compared with the sensitivity of IgM detection by ISAGA (73.26% on serum samples, 82.35% on peripheral blood). Adding the T. gondii IgA antibody ELISA to the diagnostic panel did not significantly increase the overall performance of the serological diagnosis based on IgM detection.


Asunto(s)
Toxoplasma , Toxoplasmosis Congénita , Toxoplasmosis , Anticuerpos Antiprotozoarios , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunoglobulina A , Inmunoglobulina M , Recién Nacido , Toxoplasmosis/diagnóstico , Toxoplasmosis Congénita/diagnóstico
8.
J Fungi (Basel) ; 8(3)2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-35330260

RESUMEN

While COVID-19-associated pulmonary aspergillosis is now well described in developed countries, COVID-19-associated mucormycosis (CAM) has seemed to remain quite rare in Europe. A retrospective study was performed between March 2020 to September 2021 among COVID-19 adult patients in the intensive care unit (ICU) at Toulouse Hospital (Southern France). PCR screening on respiratory samples, which target Aspergillus or Mucorales DNA, were performed, and the number of fungal detections was evaluated monthly during the study period. During the 19 months of the study, 44 (20.3%) COVID-19 ICU patients had a positive PCR for Aspergillus, an overall rate in keeping with the incidence of ICU COVID-19 patients. Ten patients (7.1%) had a positive Mucorales PCR over the same period. Surprisingly, 9/10 had a positive Mucor/Rhizopus PCR in August-September 2021, during the fourth Delta SARS-CoV-2 variant wave. Epidemic investigations have identified a probable environmental cause linked to construction works in the vicinity of the ICU (high levels of airborne spores due to the mistaken interruption of preventive humidification and summer temperature). Even if CAM are apparently rare in Europe, a cluster can also develop in industrialised countries when environmental conditions (especially during construction work) are associated with a high number of COVID-19 patients in the ICU.

9.
Microorganisms ; 10(2)2022 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-35208697

RESUMEN

For the last four decades, knowledge about human toxocariasis with regard to its epidemiology, pathophysiology, clinical spectrum, and imaging or laboratory diagnosis has substantially progressed. Knowledge about specific therapy with anthelmintics has lagged behind. To date, only four drugs are registered for human use, and their efficacy has rarely been assessed in prospective controlled trials. It is likely that the repurposing of potent anthelmintics from veterinary medicine will improve this situation. Due to its wide availability and a lack of major side effects during short regimens, albendazole has become the drug of choice. However, its efficacy should be more precisely assessed. The role of anthelmintics in the treatment of neurological or ocular toxocariasis remains to be clarified. Prophylactic measures in humans or companion animals are efficient and represent first-line treatments for the control of this zoonosis. Unfortunately, their implementation in areas or countries where toxocariasis epidemiology is driven by poverty is quite difficult or unrealistic.

10.
Microbiol Spectr ; 9(3): e0137621, 2021 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-34937195

RESUMEN

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged in December 2019 and caused a dramatic pandemic. Serological assays are used to check for immunization and assess herd immunity. We evaluated commercially available assays designed to quantify antibodies directed to the SARS-CoV-2 Spike (S) antigen, either total (Wantaï SARS-CoV-2 Ab ELISA) or IgG (SARS-CoV-2 IgG II Quant on Alinity, Abbott, and Liaison SARS-CoV-2 TrimericS IgG, Diasorin). The specificities of the Wantaï, Alinity, and Liaison assays were evaluated using 100 prepandemic sera and were 98, 99, and 97%, respectively. The sensitivities of all three were around 100% when tested on 35 samples taken 15 to 35 days postinfection. They were less sensitive for 150 sera from late infections (>180 days). Using the first WHO international standard (NIBSC), we showed that the Wantai results were concordant with the NIBSC values, while Liaison and Alinity showed a proportional bias of 1.3 and 7, respectively. The results of the 3 immunoassays were significantly globally pairwise correlated and for late infection sera (P < 0.001). They were correlated for recent infection sera measured with Alinity and Liaison (P < 0.001). However, the Wantai results of recent infections were not correlated with those from Alinity or Liaison. All the immunoassay results were significantly correlated with the neutralizing antibody titers obtained using a live virus neutralization assay with the B1.160 SARS-CoV-2 strain. These assays will be useful once the protective anti-SARS-CoV-2 antibody titer has been determined. IMPORTANCE Standardization and correlation with virus neutralization assays are critical points to compare the performance of serological assays designed to quantify anti-SARS-CoV-2 antibodies in order to identify their optimal use. We have evaluated three serological immunoassays based on the virus spike antigen that detect anti-SARS-CoV-2 antibodies: a microplate assay and two chemiluminescent assays performed with Alinity (Abbott) and Liaison (Diasorin) analysers. We used an in-house live virus neutralization assay and the first WHO international standard to assess the comparison. This study could be useful to determine guidelines on the use of serological results to manage vaccination and treatment with convalescent plasma or monoclonal antibodies.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoensayo/métodos , Anticuerpos Neutralizantes/inmunología , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunización , Inmunoglobulina G/sangre , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunología , Vacunación
11.
J Fungi (Basel) ; 7(8)2021 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-34436191

RESUMEN

The host lymphocyte response is decisive in Pneumocystis pneumonia (PCP) pathophysiology but little is known of the specific roles of lymphocyte subpopulations in this fungal infection. Peripheral NK, NKT, B, TCD4+ and TCD8+ subpopulations were compared by immunophenotyping between 20 patients diagnosed with PCP (PCP(+)] and 20 uninfected immunosuppressed patients (PCP(-)). Among PCP(+) subjects, the lymphocyte populations were also compared between surviving and deceased patients. Low B cell count (<40 cells/µL) was more frequent in PCP(+) than in PCP(-) patients (p = 0.03), while there was no difference for the TCD4 count. Among the PCP(+) group, the 7 deceased patients had lower Th1 (p = 0.02) and Tc1 (p = 0.03) populations, higher Th2 response (p = 0.03), higher effector TCD8 (p < 0.01), lower central memory TCD8 (p = 0.04) and reduced NK cells (p = 0.02) compared with the 13 survivors. Th1/Th2 ratio < 17, CD8 Tc1 < 44%, effector TCD8 < 25%, central memory TCD8 < 4%, NK cells < 50 cells/µL and total lymphocytes < 0.75 G/L were associated with a higher risk of mortality (p = 0.003, p = 0.007, p = 0.0007, p = 0.004, p = 0.02 and p = 0.019, respectively). The traditional analysis of TCD4 and TCD8 populations may be insufficient in the context of PCP. It could be completed by using B cells to predict the risk of PCP, and by using lymphocyte subpopulations or total lymphocyte count, which are easy to obtain in all health care facilities, to evaluate PCP prognosis.

12.
Parasite ; 27: 32, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32400389

RESUMEN

To assess the possible influence of atopy on the clinical picture of human toxocariasis, a retrospective study was carried out using file records for patients who attended the Outpatient Clinic of Parasitology in Toulouse University Hospitals. A total of 106 file records for patients who had been diagnosed with common/covert toxocariasis were extracted from the database. Forty-nine patients (20 females and 29 males) were considered atopic since they exhibited a long (≥ 1 year) history of various allergic issues along with a titer ≥ 0.7 kIU/L for specific IgE against at least two out of nine mixes of common inhalant allergens. Fifty-seven patients (42 females and 15 males) were designated nonatopic on the basis of a negative result (<0.35 kIU/L) of the test for specific IgE. Demographic (age and sex), clinical (20 signs or symptoms) and laboratory (blood eosinophil count, eosinophil cationic protein, serum total IgE, and specific anti-Toxocara IgE) variables were investigated by bivariate analysis followed by multivariate regression analysis using "atopy" as the outcome variable. On the basis of our results, the clinical or laboratory picture of toxocaral disease was not affected by the presence of an atopic status.


TITLE: Toxocarose humaine et atopie. ABSTRACT: Pour évaluer la possible influence de l'atopie sur la présentation clinico-biologique de la toxocarose humaine, une étude rétrospective a été réalisée à partir des dossiers de patients vus à la Consultation du Service de Parasitologie-Mycologie du CHU de Toulouse. Cent-six dossiers de patients diagnostiqués comme ayant la forme commune de la toxocarose ont été extraits de la base de données. Quarante-neuf patients (20 femmes et 29 hommes) ont été considérés comme atopiques, eu égard à une longue (≥ 1 an) histoire de manifestations allergiques couplée à une recherche positive (≥ 0.7 kUI/L) des IgE spécifiques contre au moins deux parmi 9 mélanges de pneumallergènes communs. Cinquante-sept patients (42 femmes et 15 hommes) ont été classés non atopiques sur la base d'un résultat négatif (< 0.35 kUI/L) de la recherche d'IgE spécifiques. Les variables démographiques (âge et sexe), cliniques (20 signes ou symptômes) et biologiques (numération des éosinophiles sanguins, dosage des protéines cationiques des éosinophiles, des IgE totales et des IgE spécifiques anti-Toxocara) ont été l'objet d'une analyse statistique bivariée suivie par une régression logistique multivariée, en utilisant "atopie" comme variable à expliquer. Selon nos résultats, le tableau clinique et biologique de la toxocarose n'est pas modifié par la présence d'un état atopique.


Asunto(s)
Hipersensibilidad Inmediata/inmunología , Toxocariasis/inmunología , Adulto , Animales , Anticuerpos Antihelmínticos/sangre , Proteína Catiónica del Eosinófilo/sangre , Eosinófilos/citología , Femenino , Francia , Humanos , Hipersensibilidad Inmediata/parasitología , Inmunoglobulina E/sangre , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Estudios Retrospectivos , Toxocara
13.
PLoS Negl Trop Dis ; 14(3): e0008139, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32210438

RESUMEN

BACKGROUND: Zoonotic visceral leishmaniasis (VL) is endemic in the Mediterranean basin. However, large-scale comparative analyses of the commercial kits for the serological diagnosis of this neglected disease are lacking. This study compared the performances of four enzyme-linked immunosorbent assays (ELISA) and two immunochromatographic tests (ICT) as screening tests for the serodiagnosis of human VL in the Mediterranean region. METHODOLOGY/PRINCIPAL FINDINGS: Serum samples from 319 patients living in France, Tunisia or Morocco were tested using two ICT (IT LEISH and TruQuick LEISH IgG/IgM Meridian) and four ELISA reagents (NovaLisa Leishmania infantum IgG, Bordier Leishmania infantum, Ridascreen Leishmania IgG, and Vircell Leishmania). The population with proven VL (n = 181) included 65 immunocompromised patients. Significantly higher percentages of false-negative results were obtained with all assays in immunocompromised patients, compared with the immunocompetent population. In the whole population, sensitivity and specificity ranged from 80.7% to 93.9% and from 95.7% to 100%, respectively. The maximum accuracy was observed with the Bordier and Vircell ELISA kits (96.2%), and the lowest accuracy with Ridascreen reagent (88.7%). New thresholds of positivity are proposed for the Bordier, Vircell and NovaLisa ELISA kits to achieve 95% sensitivity with the highest possible specificity. Western blot (WB), used as a confirmation method, showed 100% sensitivity and identified 10.1% of asymptomatic carriers among the control population from the South of France. CONCLUSIONS/SIGNIFICANCE: This is the first study that compared commercially available kits for VL serodiagnosis in the endemic region of the Mediterranean basin. It provides specific information about the tests' performance to help clinicians and biologists to select the right assay for VL screening.


Asunto(s)
Leishmaniasis Visceral/diagnóstico , Juego de Reactivos para Diagnóstico , Pruebas Serológicas/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Francia , Humanos , Inmunoensayo/métodos , Lactante , Masculino , Tamizaje Masivo/métodos , Región Mediterránea , Persona de Mediana Edad , Marruecos , Sensibilidad y Especificidad , Túnez , Adulto Joven
14.
Parasite ; 27: 7, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32031519

RESUMEN

BACKGROUND: Primary infection by Toxoplasma gondii in pregnant women can result in serious outcomes for the foetus. A false-positive IgG result during pregnancy can lead to a misdiagnosis of past infection and to stopping preventive measures. We collected 189 sera with positive Architect® Toxo IgG assay (Abbott Laboratories) and negative IgG results with at least two other serological tests, in order to find an explanation for the suspected false-positive IgG results. We used the recomLine Toxoplasma IgG® immunoblot (Mikrogen Diagnostik) to search for specific antigenic reactivities of the sera, and the LDBio Toxo II IgG® immunoblot (LDBio Diagnostics) as a confirmatory test. RESULTS: The bands GRA8 and/or GRA7 were positive for 148 samples (78.3%). GRA8 was the most frequent band, appearing in 133 patterns (70.4%), whereas GRA7 was present for 49 samples (25.9%). Of the 81 samples tested with LDBio®, 23 (28.4%) turned out to be positive. Of the 58 negative LDBio® tests (71.6%) (real false-positive Architect® IgG), 23 samples (39.6%) did not show either a GRA8 or p30 band by recomLine®. Their false positivity with Architect® remains unexplained since Abbott uses these two recombinant antigens for their assay. CONCLUSIONS: The Architect® IgG false positivity for T. gondii seems to be due to reactivity against GRA8 for the majority of the sera and GRA7 to a lesser extent. The hypothesis of past contact with parasites genetically close to T. gondii such as Hammondia hammondi or Neospora caninum seems promising and should be assessed further.


TITLE: Diagnostic sérologique de Toxoplasma gondii : analyse des IgG faux positifs et implications. ABSTRACT: Contexte : La primo-infection à Toxoplasma gondii chez la femme enceinte peut avoir de graves conséquences pour le fœtus. Un résultat IgG faussement positif pendant la grossesse peut mener à un diagnostic erroné d'infection ancienne et à stopper les mesures préventives. Nous avons collecté 189 sérums présentant un résultat Architect® Toxo IgG (Abbott Laboratories) positif ainsi qu'un résultat IgG négatif par au moins deux autres tests sérologiques, dans le but de trouver une explication aux résultats IgG suspectés faux positifs. Nous avons utilisé l'immunoblot recomLine Toxoplasma IgG® (Mikrogen Diagnostik) pour chercher certaines réactivités antigéniques spécifiques des sérums et l'immunoblot LDBio Toxo II IgG® (LDBio Diagnostics) comme test de confirmation. Résultats : Les bandes GRA8 et/ou GRA7 étaient positives pour 148 (78,3 %) échantillons. GRA8 était la bande la plus fréquente, apparaissant dans 133 (70,4 %) profils alors que GRA7 était présente pour 49 (25,9 %) échantillons. Sur les 81 échantillons testés en LDBio®, 23 (28,4 %) se sont révélés positifs. Sur les 58 (71,6 %) tests LDBio® négatifs (réels faux positifs IgG Architect®), 23 (39,6 %) échantillons n'ont montré ni bande GRA8 ni bande p30 en recomLine® et leur fausse positivité reste donc inexpliquée puisque Abbott utilise ces deux antigènes recombinants dans son test. Conclusions : La fausse positivité IgG Architect® pour T. gondii semble être due à une réactivité envers la protéine GRA8 pour la majorité des sérums et envers GRA7 dans une moindre mesure. L'hypothèse d'un contact passé avec des parasites génétiquement proches de T. gondii comme Hammondia hammondi ou Neospora caninum semble prometteuse et devrait être approfondie.


Asunto(s)
Anticuerpos Antiprotozoarios/sangre , Inmunoglobulina G/sangre , Pruebas Serológicas/normas , Toxoplasmosis/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Reacciones Cruzadas , Reacciones Falso Positivas , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Juego de Reactivos para Diagnóstico/normas , Toxoplasma , Toxoplasmosis/inmunología , Adulto Joven
15.
PLoS Negl Trop Dis ; 13(9): e0007711, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31509538

RESUMEN

BACKGROUND: The diagnosis of schistosomiasis currently relies on microscopic detection of schistosome eggs in stool or urine samples and serological assays. The poor sensitivity of standard microscopic procedures performed in routine laboratories, makes molecular detection methods of increasing interest. The aim of the study was to evaluate two in-house real-time Schistosoma PCRs, targeting respectively S. mansoni [Sm] and S. haematobium [Sh] in excreta, biopsies and sera as potential tools to diagnose active infections and to monitor treatment efficacy. METHODS: Schistosoma PCRs were performed on 412 samples (124 urine, 86 stools, 8 biopsies, 194 sera) from patients with suspected schistosomiasis, before anti-parasitic treatment. Results were compared to microscopic examination and serological assays (enzyme-linked immunosorbent assay (ELISA), indirect haemagglutination (HA) and Western Blot (WB) assay). RESULTS: Compared to microscopy, PCRs significantly increased the sensitivity of diagnosis, from 4% to 10.5% and from 33.7% to 48.8%, for Sh in urine and Sm in stools, respectively. The overall sensitivity of PCR on serum samples was 72.7% and reached 94.1% in patients with positive excreta (microscopy). The specificity of serum PCR was 98.9%. After treatment, serum PCR positivity rates slowly declined from 93.8% at day 30 to 8.3% at day 360, whereas antibody detection remained positive after 1 year. CONCLUSION: Schistosoma PCRs clearly outperform standard microscopy on stools and urine and could be part of reference methods combined with WB-based serology, which remains a gold standard for initial diagnosis. When serological assays are positive and microscopy is negative, serum PCRs provide species information to guide further clinical exploration. Biomarkers such as DNA and antibodies are of limited relevance for early treatment monitoring but serum PCR could be useful when performed at least 1 year after treatment to help confirm a cured infection.


Asunto(s)
Schistosoma haematobium/aislamiento & purificación , Schistosoma mansoni/aislamiento & purificación , Esquistosomiasis Urinaria/diagnóstico , Esquistosomiasis mansoni/diagnóstico , Animales , Biopsia , ADN de Helmintos/análisis , Heces/parasitología , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Esquistosomiasis Urinaria/sangre , Esquistosomiasis Urinaria/orina , Esquistosomiasis mansoni/sangre , Esquistosomiasis mansoni/orina , Sensibilidad y Especificidad , Viaje
16.
Parasite ; 26: 51, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31441775

RESUMEN

BACKGROUND: Immunocompromised patients are at high risk for the development of severe toxoplasmosis from tissue cyst reactivation, the most frequently, or from recently acquired acute infections. Knowledge of serologic status is therefore crucial. Screening for toxoplasmosis is sometimes performed while patients are already immunocompromised and have a low or even undetectable IgG titer by routine automated enzyme immunoassays. The aim of this study was to assess the sensitivity and specificity of seven reagents for the detection of low levels of IgG. Sera from 354 patients were collected and analysed. RESULTS: Elecsys® offered the best analytic performances, superior to those of Architect® and Platelia®, which were superior to those of Access II® and TGS TA®. Vidas II® and Liaison II® reagents exhibited poor analytical performances in this cohort. For Elecsys®, Platelia® and Architect®, new thresholds for the grey zone and positive zone have been defined to improve the sensitivity of these reagents while maintaining excellent specificity. CONCLUSIONS: Commercialized assays for toxoplasmosis screening are not suitable for IgG low-level detection in patients without adapting the supplier thresholds to avoid false negative results and risk generalized toxoplasmosis.


TITLE: Performance de sept tests automatisés du commerce pour la détection de faibles taux d'IgG anti-Toxoplasma chez des patients immunodéprimés français. ABSTRACT: Contexte : Les patients immunodéprimés courent un risque élevé de développer une toxoplasmose grave résultant de la réactivation de kystes tissulaires, le plus souvent, ou d'infections aiguës récemment contractées. La connaissance du statut sérologique est donc cruciale. Le dépistage de la toxoplasmose est parfois effectué chez des patients déjà immunodéprimés et dont le titre en IgG est faible, voire indétectable, par les immunoessais enzymatiques automatisés de routine. Le but de cette étude était d'évaluer la sensibilité et la spécificité de sept réactifs pour la détection de faibles taux d'IgG. Les sérums de 354 patients ont été recueillis et analysés. Résultats : Elecsys® offre les meilleures performances analytiques, supérieures à celles d'Architect® et de Platelia®, supérieures à celles d'Access II® et de TGS TA®. Les réactifs Vidas II® et Liaison II® ont présenté des performances analytiques médiocres dans cette cohorte. Pour Elecsys®, Platelia® et Architect®, de nouveaux seuils pour la zone grise et la zone positive ont été définis pour améliorer la sensibilité de ces réactifs tout en maintenant une excellente spécificité. Conclusions : Les tests commercialisés pour le dépistage de la toxoplasmose ne conviennent pas à la détection de faibles taux d'IgG chez les patients sans adaptation des seuils des fournisseurs pour éviter les résultats faux négatifs et le risque de toxoplasmose généralisée.


Asunto(s)
Anticuerpos Antiprotozoarios/sangre , Huésped Inmunocomprometido , Inmunoglobulina G/sangre , Juego de Reactivos para Diagnóstico/normas , Toxoplasmosis/inmunología , Adulto , Automatización de Laboratorios/normas , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Sensibilidad y Especificidad , Pruebas Serológicas/normas , Toxoplasma/inmunología , Toxoplasmosis/diagnóstico , Adulto Joven
17.
Artículo en Inglés | MEDLINE | ID: mdl-30766842

RESUMEN

Aspergillus sp. fungi cause various diseases in both immunocompetent and immunocompromised patients. The most frequent Aspergillus disorders include chronic pulmonary aspergillosis (CPA), a life-threatening disease that affects at least 3 million people worldwide, and allergic bronchopulmonary aspergillosis (ABPA), which affects approximately 4.8 million severe asthmatic patients globally. Diagnosis of such diseases involves IgG serological testing; however, the currently available anti-Aspergillus IgG detection assays are inappropriate for resource-poor laboratory settings, as they are expensive, rely on automated procedures, and require stable electrical power. Therefore, accurate CPA or ABPA diagnosis facilities are lacking in most low- and middle-income countries. We evaluated a novel anti-Aspergillus antibody immunochromatographic test (ICT) that requires minimal laboratory equipment. Two evaluations were performed: a single-center 4-month prospective study in a French reference laboratory (44 cases/257 patients) and a retrospective study in five French reference laboratories (262 cases and 188 controls). We estimated the ICT indices for the diagnosis of chronic aspergillosis, and the test results were compared to those of anti-Aspergillus IgG immunoblot (IB) assay. Of the 713 patients included in the study, 306 had chronic aspergillosis. Test sensitivity and specificity were 88.9% (95%CI[85-92]) and 96.3% (95%CI[94-98]) for the ICT and 93.1% (95%CI[90-96]) and 94.3% (95%CI[92-96]) for the IB, respectively. Agreement between the two assays was almost perfect (kappa = 0.86). As this ICT displays good diagnostic performance and complies with the ASSURED (Affordable, Sensitive, Specific, User-friendly, Equipment-free, and Delivered) criteria, we concluded that this anti-Aspergillus antibody ICT can be used to diagnose Aspergillus diseases in resource-poor settings.


Asunto(s)
Anticuerpos Antifúngicos/sangre , Aspergilosis/diagnóstico , Aspergillus/inmunología , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Pruebas Serológicas/métodos , Francia , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad
18.
Euro Surveill ; 23(4)2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29382413

RESUMEN

Seven cases of urogenital schistosomiasis occurred in Corsica in 2015 and 2016. The episodes were related to exposure to the same river and involved the same parasite strain as an outbreak with 106 cases in summer 2013. The connection calls for further investigations on the presence of an animal reservoir and the survival of infested snails during winter. However, recontamination of the river from previously infected bathers remains the most likely hypothesis.


Asunto(s)
Bulinus/parasitología , Schistosoma haematobium/aislamiento & purificación , Schistosoma/aislamiento & purificación , Esquistosomiasis Urinaria/transmisión , Animales , Notificación de Enfermedades , Monitoreo del Ambiente , Agua Dulce , Humanos , Schistosoma haematobium/genética , Esquistosomiasis Urinaria/parasitología , Esquistosomiasis Urinaria/orina , Caracoles/parasitología
19.
Mil Med Res ; 4: 15, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28546866

RESUMEN

BACKGROUND: Blood eosinophilia is a common laboratory abnormality, and its characterization frequently represents a quandary for primary care physicians. Consequently, in France, specialists and particularly hematologists, often must investigate patients who present with blood eosinophilia that often, but not always, occurs because of allergic causes. Both the Departments of Hematology and Parasitology at Toulouse University Hospitals established a collaboration to rule out allergic causes of eosinophilia, particularly helminthiases, prior to initiating more sophisticated investigations. METHODS: Since 2004, the authors employed the same protocol to investigate eosinophilic outpatients who attended the clinic of Parasitology at Toulouse University Hospitals, and they reported the performance of this diagnostic procedure that was designed to be rapid (no hospitalization required) and only moderately expensive. RESULTS: A total of 406 patients who presented with blood eosinophilia greater than 0.5 (×109, giga cells per litter, G/L) had an allergic etiology in 350 (86.2%) cases. Among the remaining 56 subjects, 17 did not undergo a follow-up and 39 were referred to another specialized department, mostly Hematology. However, only 21 patients attended then were subsequently investigated. Non-allergic causes of eosinophilia, including 3 cases of the lymphoid variant of hypereosinophilic syndrome and 2 cases of myeloproliferative disorder, were identified in 14 patients, whereas 7 remained diagnosed as having idiopathic eosinophilia. CONCLUSION: This study underlines the need to investigate patients presenting with even moderate blood eosinophilia. The work-up that was employed appears to be efficient and versatile and may be used by any medical specialist, such as in hematology, infectious disease, or internal medicine departments, who needs to investigate eosinophilic patients and should initially rule out any etiology of allergic eosinophilia.


Asunto(s)
Protocolos Clínicos/normas , Eosinofilia/etiología , Hipersensibilidad/complicaciones , Hipersensibilidad/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Eosinofilia/fisiopatología , Femenino , Francia , Humanos , Hipersensibilidad/economía , Masculino , Persona de Mediana Edad , Micología , Exposición Profesional/efectos adversos , Pacientes Ambulatorios/estadística & datos numéricos , Enfermedades Parasitarias/complicaciones , Encuestas y Cuestionarios
20.
Diagn Microbiol Infect Dis ; 87(2): 103-107, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27884549

RESUMEN

We assessed the ability to early detect a toxoplasmic seroconversion between 1 immunoblot (LDBIO II®) and 6 automated assays (TGS TA®, Architect®, Vidas II®, Liaison II®, Platelia®, and Elecsys®), comparing the time before anti-Toxoplasma gondii IgG detection during infection in pregnant women. From 2007 to 2015, 620 sera of 269 women were included. The median durations before positive IgG detection with Vidas II®, Liaison II®, Platelia®, and Elecsys® were significantly longer than Architect® with differential times from 11 to 28days (P<0.001). This time was significantly shortened by the use of LDBIO®, resulting in a saving of 13days (P<0.001). The detection of a positive rate of IgG with TGS TA® was as early as Architect® (P=0.105). The ability to early detect a toxoplasmic seroconversion is not equivalent between the assays and has to be considered when selecting the reagents to reduce the time to therapeutic intervention.


Asunto(s)
Anticuerpos Antiprotozoarios/sangre , Pruebas Diagnósticas de Rutina/métodos , Inmunoglobulina G/sangre , Complicaciones Infecciosas del Embarazo/diagnóstico , Seroconversión , Toxoplasma/inmunología , Toxoplasmosis/diagnóstico , Adulto , Automatización de Laboratorios/métodos , Femenino , Francia , Humanos , Embarazo , Juego de Reactivos para Diagnóstico , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...