Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Orthop J Sports Med ; 11(9): 23259671231196875, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37736603

RESUMEN

Background: Healing of the rotator cuff after repair constitutes a major clinical challenge with reported high failure rates. Identifying structural musculotendinous predictors for failed rotator cuff repair could enable improved diagnosis and management of patients with rotator cuff disease. Purpose: To investigate structural predictors of the musculotendinous unit for failed tendon healing after rotator cuff repair. Study Design: Cohort study; Level of evidence, 2. Methods: Included were 116 shoulders of 115 consecutive patients with supraspinatus (SSP) tear documented on magnetic resonance imaging (MRI) who were treated with an arthroscopic rotator cuff repair. Preoperative assessment included standardized clinical and imaging (MRI) examinations. Intraoperatively, biopsies of the joint capsule, the SSP tendon, and muscle were harvested for histological assessment. At 3 and 12 months postoperatively, patients were re-examined clinically and with MRI. Structural and clinical predictors of healing were evaluated using logistic and linear regression models. Results: Structural failure of tendon repair, which was significantly associated with poorer clinical outcome, was associated with older age (ß = 1.12; 95% CI, 1.03 to 1.26; P = .03), shorter SSP tendon length (ß = 0.89; 95% CI, 0.8 to 0.98; P = .02), and increased proportion of slow myosin heavy chain (MHC)-I/fast MHC-II hybrid muscle fibers (ß = 1.23; 95% CI, 1.07 to 1.42; P = .004). Primary clinical outcome (12-month postoperative Constant score) was significantly less favorable for shoulders with fatty infiltration of the infraspinatus muscle (ß = -4.71; 95% CI, -9.30 to -0.12; P = .044). Conversely, a high content of fast MHC-II muscle fibers (ß = 0.24; 95% CI, 0.026 to 0.44; P = .028) was associated with better clinical outcome. Conclusion: Both decreased tendon length and increased hybrid muscle fiber type were independent predictors for retear. Clinical outcome was compromised by tendon retearing and increased fatty infiltration of the infraspinatus muscle. A high content of fast MHC-II SSP muscle fibers was associated with a better clinical outcome. Registration: NCT02123784 (ClinicalTrials.govidentifier).

2.
J Shoulder Elbow Surg ; 30(11): e676-e688, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33878485

RESUMEN

BACKGROUND: With progress in arthroscopic surgery, latissimus dorsi transfer for irreparable posterosuperior rotator cuff tears (RCTs) has become a reliable all-arthroscopic or arthroscopically assisted procedure. The mid-term results of arthroscopically assisted latissimus dorsi transfer (aLDT) are scarce in the literature. The purpose of this study was to report our clinical and radiographic mid-term results of aLDT for irreparable posterosuperior RCTs. METHODS: Thirty-one consecutive patients with a mean age of 55.5 years (range, 38-73 years) at the time of aLDT were evaluated after a mean of 3.5 years (range, 2-5 years). All patients had irreparable, full-thickness tears of at least the complete supraspinatus, with or without infraspinatus tendons, and 12 patients (39%) had undergone previous rotator cuff repair (RCR). A concomitant upper-third subscapularis repair was needed at the time of aLDT in 7 patients (23%). Mid-term results were assessed clinically and radiographically (including magnetic resonance imaging). RESULTS: At final follow-up, 4 patients with failure (13%) had undergone revision to reverse total shoulder arthroplasty (RTSA) essentially for untreatable pain. Patients with revision to RTSA had significantly higher preoperative pain levels (Constant pain score, 6 points vs. 11 points; P = .032) and lower Constant activity scores (2 points vs. 5 points, P = .017) than the remaining 27 patients. Patients with failed previous RCRs had significantly inferior results compared with patients without previous repair (mean Subjective Shoulder Value, 67% vs. 88%; P = .035). For the 27 patients without revision, the mean relative Constant score improved from 63% to 76% (P = .032), the Constant pain score, from 10.5 to 12.7 points (P = .012), and the Subjective Shoulder Value, from 43% to 77% (P < .001). Significant progression of glenohumeral arthropathy by 2 or more grades according to the Hamada classification was observed in 13 of the 27 patients (48%), but there was no significant difference in clinical outcomes between the patients with arthropathy (n = 13) and those without it (n = 14, P = .923). CONCLUSIONS: The mid-term results of aLDT for irreparable posterosuperior RCTs were associated with significant improvements in objective and subjective outcome measures. The failure rate leading to conversion to RTSA was relatively high in this cohort. The failures were associated with unusually intense pain in low-demand individuals and/or revision of failed RCR. Long-term results of aLDT are needed to evaluate the effect of this procedure on the progression of osteoarthritis.


Asunto(s)
Lesiones del Manguito de los Rotadores , Músculos Superficiales de la Espalda , Adulto , Anciano , Humanos , Persona de Mediana Edad , Rango del Movimiento Articular , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Transferencia Tendinosa , Resultado del Tratamiento
3.
J Shoulder Elbow Surg ; 30(9): 2022-2031, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33545338

RESUMEN

BACKGROUND: Rock climbers are particularly susceptible to shoulder injuries due to repetitive upper-limb movements on vertical or overhanging terrain. However, the long-term effects of prolonged climbing on the shoulder joints are still unknown. PURPOSE: The purpose of this study was to analyze the prevalence of pain and degenerative changes in the shoulder joints after high-level rock climbing over at least 25 years. We hypothesized that specific climber-associated patterns of degeneration would be found. METHODS: Thirty-one adult male high-level rock climbers were compared to an age- and sex-matched control group of 31 nonclimbers. All participants underwent a detailed interview, standardized clinical examination, and bilateral (climbers) or unilateral (nonclimbers, dominant side) magnetic resonance imaging (MRI) scans. Clinical and MRI findings of the groups were compared. RESULTS: The lifetime prevalence of shoulder pain in the rock climbers was 77%. The rock climbers had significantly more abnormalities in the labrum (82% vs. 52%; P = .002), long biceps tendon (53% vs. 23%; P = .006), and cartilage (28% vs. 3%; P = .005). These increased changes positively correlated with climbing intensity. There were no differences between the 2 groups with respect to rotator cuff tendon pathology (68% vs. 58%; P = .331) and acromioclavicular joint degeneration (88% vs. 90%; P = .713). Despite the increased degenerative changes in the rock climbers, their Constant score (CS) was still better than that of the nonclimbers (CS 94, interquartile range [IQR] 92-97, vs. CS 93, IQR 91-95; P = .019). CONCLUSIONS: Prolonged high-level rock climbing leads to a high prevalence of shoulder pain and increased degenerative changes to the labrum, long biceps tendon, and cartilage. However, it is not related to any restriction in shoulder function.


Asunto(s)
Traumatismos en Atletas , Montañismo , Lesiones del Hombro , Adulto , Humanos , Imagen por Resonancia Magnética , Masculino , Hombro , Lesiones del Hombro/diagnóstico por imagen
4.
Skeletal Radiol ; 50(6): 1177-1188, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33169220

RESUMEN

OBJECTIVE: To prospectively assess the evolution of postoperative MRI findings in asymptomatic patients after total hip arthroplasty (THA) over 24 months (mo). METHODS: This prospective cohort study included 9 asymptomatic patients (56.7 ± 15.0 years) after THA. Metal artifact-reduced 1.5-T MRI was performed at 3, 6, 12, and 24 mo after surgery. The femoral stem and acetabular cup were assessed by two readers for bone marrow edema (BME), periprosthetic bone resorption, and periosteal edema in addition to periarticular soft tissue edema and joint effusion. RESULTS: BME was common around the femoral stem in all Gruen zones after 3 mo (range: 50-100%) and 6 mo (range: 33-100%) and in the acetabulum in DeLee and Charnley zone II after 3 mo (100%) and 6 mo (33%). BME decreased substantially after 12 mo (range: 0-78%) and 24 mo (range: 0-50%), may however persist in particular in Gruen zones 1 + 7. Periosteal edema along the stem was common 3 mo postoperatively (range: 63-75%) and rare after 24 mo: 13% only in Gruen zones 2 and 5. Twelve months and 24 mo postoperatively, periprosthetic bone resorption was occasionally present around the femoral stem (range: 11-33% and 13-38%, respectively). Soft tissue edema occurred exclusively along the surgical access route after 3 mo (100%) and 6 mo (89%) and never at 12 mo or 24 mo (0%). CONCLUSION: Around the femoral stem, BME (33-100%) and periosteal edema (0-75%) are common until 6 mo after THA, decreasing substantially in the following period, may however persist up to 24 mo (BME: 0-50%; periosteal edema: 0-13%) in few non-adjoining Gruen zones. Soft tissue edema along the surgical access route should have disappeared 12 mo after surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artefactos , Densidad Ósea , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos
5.
Radiology ; 296(1): 98-108, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32396046

RESUMEN

Background MRI with metal artifact reduction has gained importance in assessment of pain with total hip arthroplasty (THA). However, its role in diagnosis of periprosthetic joint infection (PJI) has not been well defined. Purpose To evaluate findings of PJI after THA and to determine the diagnostic performance of 1.5-T MRI with metal artifact reduction. Materials and Methods Dedicated compressed sensing-based slice encoding for metal artifact correction 1.5-T MRI examinations (from January 2015 to April 2018) in patients with THA PJI (infection group) and noninfected THA (control group) were retrospectively evaluated by two musculoskeletal radiologists. Fisher exact test was used to compare the groups. Sensitivity, specificity, and accuracy were evaluated for each finding. Interobserver reliability was assessed with κ statistics. Results Forty patients (mean age, 69 years ± 11 [standard deviation]; 26 men) in the infection group and 100 patients (mean age, 67 years ± 11; 42 men) in the control group were evaluated. Periosteal reaction, capsule edema, and intramuscular edema differed between the two groups (P < .001 for each finding). Periosteal reaction was found in 31 of 40 patients with infection and 10 of 100 participants in the control group (sensitivity, 78%; specificity, 90%; accuracy, 86%); capsule edema was found in 33 of 40 (infection group) and five of 100 (control group) (sensitivity, 83%; specificity, 95%; accuracy, 91%); and intramuscular edema was found in 38 of 40 (infection group) and 14 of 100 (control group) (sensitivity, 95%; specificity, 86%; accuracy, 89%). Interobserver agreement was almost perfect, with κ values between 0.88 and 0.92. No difference between the two groups was found regarding the presence of osteolysis (infection group, 23 of 40; control group, 60 of 100), bone marrow edema (39 of 40 vs 87 of 100), effusion (20 of 40 vs 26 of 100), abductor tendon lesion (22 of 40 vs 62 of 100), or bursitis (14 of 40 vs 34 of 100) (P > .05 for each finding). Conclusion The presence of periosteal reaction, capsule edema, and intramuscular edema after total hip arthroplasty at 1.5-T MRI with metal artifact reduction had a high accuracy in evaluation of periprosthetic joint infection. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Zanetti in this issue.


Asunto(s)
Artefactos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Anciano , Femenino , Articulación de la Cadera/microbiología , Prótesis de Cadera/microbiología , Humanos , Masculino , Metales , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
Eur Radiol ; 30(4): 2241-2252, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31863147

RESUMEN

OBJECTIVES: To assess the spectrum of periprosthetic MRI findings after primary total hip arthroplasty (THA). METHODS: This multi-center cohort study analyzed 31 asymptomatic patients (65.7 ± 12.7 years) and 27 symptomatic patients (62.3 ± 11.9 years) between 6 months and 2 years after THA. 1.5-T MRI was performed using Compressed Sensing SEMAC and high-bandwidth sequences. Femoral stem and acetabular cup were assessed for bone marrow edema, osteolysis, and periosteal reaction in Gruen zones and DeLee and Charnley zones. Student t test and Fisher's exact test were performed. RESULTS: The asymptomatic and symptomatic groups showed different patterns of imaging findings. Bone marrow edema was seen in 19/31 (61.3%) asymptomatic and 22/27 (81.5%) symptomatic patients, most commonly in Gruen zones 1, 7, and 8 (p ≥ 0.18). Osteolysis occurred in 14/31 (45.2%) asymptomatic and 14/27 (51.9%) symptomatic patients and was significantly more common in Gruen zone 7 in the symptomatic group (8/27 (29.6%)) compared to the asymptomatic group (2/31 (6.5%)) (p = 0.03). Periosteal reaction was present in 4/31 asymptomatic (12.9%) and 9/27 symptomatic patients (33.3%) and more common in Gruen zones 5 and 6 in the symptomatic group (p = 0.04 and 0.02, respectively). In the acetabulum, bone marrow edema pattern was encountered in 3/27 (11.1%) symptomatic patients but not in asymptomatic patients (p ≥ 0.21). Patient management was altered in 8/27 (29.6%) patients based on MRI findings. CONCLUSIONS: Periprosthetic bone marrow edema is common after THA both in asymptomatic and symptomatic patients. Osteolysis and periosteal reaction are more frequent in symptomatic patients. MRI findings led to altered patient management in 29.6% of patients. KEY POINTS: • Bone marrow edema pattern was frequent in both asymptomatic and symptomatic patients after THA, particularly around the proximal femoral stem in Gruen zones 1, 7, and 8. • Osteolysis was significantly more frequent in symptomatic patients in Gruen zone 7. • Periosteal reaction occurred more frequently in symptomatic patients in Gruen zones 5 and 6.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema/diagnóstico por imagen , Fémur/diagnóstico por imagen , Prótesis de Cadera , Imagen por Resonancia Magnética/métodos , Osteólisis/diagnóstico por imagen , Periostio/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Enfermedades Asintomáticas , Estudios de Cohortes , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Estudios Prospectivos
7.
Am J Sports Med ; 47(13): 3080-3088, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31536372

RESUMEN

BACKGROUND: Muscle atrophy and fatty infiltration are limiting factors for successful rotator cuff (RC) repair. Quantitative data regarding these hallmarks of degenerative muscle changes after RC repair in humans are scarce. By utilizing a new application of the 6-point Dixon magnetic resonance imaging technology, 3-dimensional volume and fat fraction analysis of the whole RC muscle have become possible. PURPOSE: Quantitative analysis of atrophy and fatty infiltration of the supraspinatus muscle after healed and failed RC tendon-to-bone repair. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Muscle volume and fat fraction were measured preoperatively and at 3 and 12 months postoperatively in 19 failed and 21 healed arthroscopic supraspinatus tendon repairs, with full muscle volume segmentation and magnetic resonance Dixon sequences. RESULTS: In both groups, the muscle volume initially decreased 3 months after RC repair by -3% in intact (P = .140) and -10% in failed repair (P = .004) but recovered between 3 and 12 months to 103% (P = .274) in intact and 92% (P = .040) in failed repairs when compared with the preoperative volume (difference of change between groups, preoperative to 12 month: P = .013). The supraspinatus muscle's fat fraction did not significantly change after successful repair (6.5% preoperative, 6.6% after 3 months, and 6.7% after 12 months; all nonsignificant). There was, however, a significant increase from 7.8% to 10.8% at 3 months (P = .014) and 11.4% at 12 months (P = .020) after failed repair (difference between groups at 3- and 12-month follow-up: P = .018 and P = .001, respectively). CONCLUSION: After successful arthroscopic repair, RC tendon tear-induced fatty infiltration can be almost stopped, and muscle atrophy can even be slightly reversed. In case of a failed repair, however, these changes are further pronounced during the first 3 postoperative months but seem to stabilize thereafter.


Asunto(s)
Adiposidad , Atrofia Muscular/etiología , Complicaciones Posoperatorias/etiología , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/fisiología , Adulto , Anciano , Artroplastia , Artroscopía , Estudios de Cohortes , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Atrofia Muscular/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Periodo Posoperatorio , Estudios Prospectivos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/complicaciones , Tendones/cirugía , Insuficiencia del Tratamiento
8.
Heliyon ; 4(10): e00853, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30364500

RESUMEN

PURPOSE: To compare conventional single-shot echo planar imaging (ss-EPI) and simultaneous multi-slice (SMS) readout-segmented EPI (rs-EPI) for magnetic resonance diffusion tensor imaging (DTI) of the ulnar nerve. MATERIALS AND METHODS: This study was approved by the local ethics committee. Ten healthy volunteers (mean age 30.4 ± 4.01 years; range 25-36 years) underwent 3T DTI of the ulnar nerve at the level of the cubital tunnel. DTI was performed based on ss-EPI as well as SMS rs-EPI sequences. Signal-to-noise ratio (SNR), image quality, and DTI parameters in the ulnar nerve (fractional anisotropy, FA; mean diffusivity, MD) were compared between the two sequences by two independent radiologists. RESULTS: Acquisition time was 5:12 min for ss-EPI and 5:18 min for SMS rs-EPI. Between the two sequences, no significant differences were found for derived DTI measures FA (p = 0.11) and MD values (p = 0.93). Compared to conventional ss-EPI, SMS rs-EPI yielded significantly less ghosting artifacts (p = 0.04) but inferior nerve depiction (p = 0.001) and worse overall image quality (p = 0.008). CONCLUSION: SMS rs-EPI is not advantageous over ss-EPI in DTI of the ulnar nerve at the level of the cubital tunnel.

9.
Radiology ; 289(1): 170-180, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30040056

RESUMEN

Purpose To determine the diagnostic performance of MRI for helping to predict posterolateral knee instability in patients with acute anterior cruciate ligament (ACL) tear. Materials and Methods This retrospective cohort study was performed in a consecutive series of 162 patients (mean age, 32.8 years ± 10.0 [standard deviation]; 95 men [mean age, 31.0 years ± 9.6] and 67 women [mean age, 35.4 years ± 10.0]) who underwent ACL reconstruction with (n = 19) or without (n = 143) concomitant posterolateral corner (PLC) reconstruction between June 2014 and February 2017. MR images were evaluated by two radiologists. Diagnostic performance of imaging findings was calculated. Clinical evidence of posterolateral instability requiring PLC reconstruction served as reference standard. The most significant predictors of posterolateral instability were determined with decision tree analysis. Results In patients with and without PLC reconstruction, respectively, the lateral collateral ligament was completely torn in 10 of 19 (52.6%) and seven of 143 (4.9%) patients; the posterior cruciate ligament in two of 19 (10.5%) and five of 143 (3.5%) patients; the popliteus tendon in three of 19 (15.8%) and none of 143 (0%) patients; and the biceps femoris tendon in four of 19 (21.1%) and none of 143 (0%) patients (data for reader 1). The smaller structures of the PLC were not constantly viewable. Complete tear or avulsion of the lateral collateral ligament was more frequent in patients who needed PLC reconstruction (P < .001), and decision tree analysis revealed that this finding was the most statistically significant predictor of posterolateral instability. Instability was correctly predicted in 147 of 162 patients (90.7%) by reader 1 and 151 of 162 patients (93.2%) by reader 2. Conclusion Complete tear or avulsion of the lateral collateral ligament was the most significant predictor at MRI of posterolateral instability. Assessment of the smaller posterolateral corner structures did not improve diagnostic performance. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Árboles de Decisión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Adulto Joven
10.
Radiol Clin North Am ; 55(5): 1055-1070, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28774448

RESUMEN

This article clarifies the current role of MR imaging in the assessment of myopathies. Typical MR imaging findings are discussed for different forms of myopathies, including idiopathic inflammatory myopathies, muscular dystrophies, and congenital myopathies. The last section deals with advanced MR imaging techniques and their potential role in further characterization of muscular disease.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Enfermedades Musculares/diagnóstico por imagen , Humanos
11.
PLoS One ; 12(1): e0169349, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28107436

RESUMEN

PURPOSE: The aim of this study was to evaluate the relevance of the three-dimensional (3D) structure of breast microcalcifications (MC) as a predictor of malignancy using highly resolved micro-computed tomography (micro-CT) datasets of biopsy samples. MATERIAL AND METHODS: The study included 28 women with suspicious MC in their mammogram undergoing vacuum-assisted biopsy. Directly after the intervention, the specimens were scanned in a micro-CT with an isometric spatial resolution of 9 µm. Datasets were analysed regarding the number, volume and morphology of suspicious non-monomorphic MC (fl-fine linear, fp-fine pleomorphic, ch-coarse heterogeneous) and the structure model index (SMI). Histological evaluation was performed according to the B-classification: normal tissue or benign (group A: B1, B2), unclear malignant potential or suspicious of malignancy (group B: B3, B4) and malignant lesions (group C: B5). RESULTS: In all groups, suspicious non-monomorphic MC were found: group A exhibited fp MC in 38.5% of samples, no fl/ch; group B: fl 14.3%, fp 28.6%, ch 14.3%; group C always had at least one type of suspicious non-monomorphic MC (fl (57.1%) or fp (57.1%)) in each sample. The different histologic groups showed a similar mean SMI (benign: 2.97 ± 0.31, malignant: 3.02 ± 0.10, unclear: 2.90 ± 0.28). Between the three groups, no significant differences were found regarding number, volume or SMI value of MC. CONCLUSION: 3D structure based on the SMI of MC analysed with highest spatial resolution is not significantly associated with the B-classification of breast lesions. Thus, magnification views of MC may be omitted in the analysis of MC detected in mammograms.


Asunto(s)
Algoritmos , Enfermedades de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Biopsia , Femenino , Humanos , Imagenología Tridimensional , Persona de Mediana Edad
12.
Invest Radiol ; 52(6): 381-387, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28092272

RESUMEN

OBJECTIVE: The aim of this study was to compare the degree of artifact reduction in magnetic resonance imaging achieved with slice encoding for metal artifact correction (SEMAC) in combination with view angle tilting (VAT) and multiacquisition variable resonance image combination (MAVRIC) for standard contrast weightings and different metallic materials. METHODS: Four identically shaped rods made of the most commonly used prosthetic materials (stainless steel, SS; titanium, Ti; cobalt-chromium-molybdenum, CoCr; and oxidized zirconium, oxZi) were scanned at 3 T. In addition to conventional fast spin-echo sequences, metal artifact reduction sequences (SEMAC-VAT and MAVRIC) with varying degrees of artifact suppression were applied at different contrast weightings (T1w, T2w, PDw). Two independent readers measured in-plane and through-plane artifacts in a standardized manner. In addition, theoretical frequency-offset and frequency-offset-gradient maps were calculated. Interobserver agreement was assessed using intraclass correlation coefficient. RESULTS: Interobserver agreement was almost perfect (intraclass correlation coefficient, 0.86-0.99). Stainless steel caused the greatest artifacts, followed by CoCr, Ti, and oxZi regardless of the imaging sequence. While for Ti and oxZi rods scanning with weak SEMAC-VAT showed some advantage, for SS and CoCr, higher modes of SEMAC-VAT or MAVRIC were necessary to achieve artifact reduction. MAVRIC achieved better artifact reduction than SEMAC-VAT at the cost of longer acquisition times. Simulations matched well with the apparent geometry of the frequency-offset maps. CONCLUSIONS: For Ti and oxZi implants, weak SEMAC-VAT may be preferred as it is faster and produces less artifact than conventional fast spin-echo. Medium or strong SEMAC-VAT or MAVRIC modes are necessary for significant artifact reduction for SS and CoCr implants.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Metales , Cromo , Cobalto , Variaciones Dependientes del Observador , Fantasmas de Imagen , Estudios Prospectivos , Titanio
13.
J Magn Reson Imaging ; 46(3): 663-677, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28067973

RESUMEN

PURPOSE: To assess the feasibility of diffusion tensor imaging (DTI) using simultaneous multislice (SMS) acquisition with blipped controlled aliasing in parallel imaging (CAIPI) for accelerated readout-segmented echo planar imaging (rs-EPI) of the mandibular nerves. DTI of the mandibular nerves using EPI is challenging due to susceptibility artifacts. Rs-EPI is less prone to artifacts but associated with longer scan durations. MATERIALS AND METHODS: Eight asymptomatic volunteers were imaged at 3T using a 64-channel head/neck coil. Conventional, 2-fold (2xSMS) and 3-fold (3xSMS) slice-accelerated rs-EPI sequences were acquired. Tractography of the mandibular nerves was performed. Signal-to-noise ratio (SNR), fractional anisotropy (FA), mean diffusivity (MD), and number of tracts were calculated. Artifacts were evaluated qualitatively on Likert scales. Parameters were compared statistically. Clinical feasibility of 2xSMS rs-EPI was tested in four patients. RESULTS: SNR was similar for conventional (mean ± SD; 8.55 ± 3.90) and 2xSMS rs-EPI (7.83 ± 3.15) but lower for 3xSMS rs-EPI (5.42 ± 2.93; analysis of variance, P = 0.004). FA was similar for all sequences (rs-EPI, 0.42 ± 0.08; 2xSMS rs-EPI, 0.43 ± 0.08; 3xSMS rs-EPI, 0.44 ± 0.06), while 3xSMS rs-EPI showed lower MD (rs-EPI, 0.0015 ± 0.0003; 2xSMS rs-EPI, 0.0014 ± 0.0001; 3xSMS rs-EPI, 0.0013 ± 0.0003) and lower number of tracts (rs-EPI, 66.56 ± 51.31; 2xSMS rs-EPI, 65.75 ± 55.40; 3xSMS rs-EPI, 37.93 ± 52.42) compared to rs-EPI and 2xSMS rs-EPI. Additionally, 2xSMS rs-EPI was feasible in four clinical patients and provided robust imaging results. CONCLUSION: 2xSMS rs-EPI yielded similar SNR, FA, and MD values compared to conventional rs-EPI at reduced scan time and is feasible in clinical patients. These findings suggest the potential clinical applicability of rs-EPI for DTI of the mandibular nerve. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:663-677.


Asunto(s)
Imagen de Difusión Tensora/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Nervio Mandibular/diagnóstico por imagen , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
14.
Invest Radiol ; 52(3): 163-169, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27662577

RESUMEN

OBJECTIVES: The aims of this study were to implement a protocol for simultaneous multislice (SMS) accelerated diffusion-weighted imaging (DWI) of the kidneys and to perform a systematic analysis of image quality of the data sets. MATERIALS AND METHODS: Ten healthy subjects and 5 patients with renal masses underwent DWI of the kidney in this prospective institutional review board-approved study on a 3 T magnetic resonance scanner. Simultaneous multislice DWI echo-planar sequences (acceleration factors [AFs] 2 and 3) were compared with conventional echo-planar DWI as reference standard for each acquisition scheme. The following 3 acquisition schemes were applied: comparison A, with increased number of acquisitions at constant scan time; comparison B, with reduction of acquisition time; and comparison C, with increased slice resolution (constant acquisition time, increasing number of slices). Interreader reliability was analyzed by calculating the intraclass correlation coefficient (ICC). Qualitative image quality features were evaluated by 2 independent radiologists on a 5-point Likert scale. Quantification accuracy of the apparent diffusion coefficients (ADCs) and signal-to-noise ratios (SNRs) were assessed by region of interest analysis. Furthermore, lesion conspicuity in the 5 patients was assessed using a 5-point Likert scale by 2 independent radiologists. RESULTS: Interreader agreement was substantial with an ICC of 0.68 for the overall image quality and an ICC of 0.73 for the analysis of artifacts. In comparison A, AF2 resulted in increased SNR (P < 0.05) by 21% at stable image quality scores (image quality: P = 0.76, artifacts: P = 0.21). In comparison B, applying AF2, the scan time could be reduced by 46% without significant reduction in qualitative image quality scores (P = 0.059) or SNR (P = 0.126). In comparison C, slice resolution could be improved by 28% using AF2 with stable image quality scores and SNR. In general, AF3 resulted in reduced image quality and SNR. Significantly reduced ADC values were observed for AF3 in comparison C (cortex: P = 0.003; medulla: P = 0.001) compared with the standard echo-planar imaging sequence. The conventional DWI and the SMS DWI with AF2 showed stable lesion conspicuity ([AF1/AF2]: reader 1 [1.8/1.4] and reader 2 [1.8/1.4]). The lesion conspicuity was lower using AF3 (reader 1: 2.2 and reader 2: 1.8). CONCLUSIONS: In conclusion, SMS DWI of the kidney is a potential tool to substantially reduce scan time without negative effects on SNR, ADC quantification accuracy, and image quality if an AF2 is used. Although AF3 results in even higher scan time reduction, a negative impact on image quality, SNR, ADC quantification accuracy, and lesion conspicuity must be considered.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Renales/diagnóstico por imagen , Adulto , Artefactos , Femenino , Humanos , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Relación Señal-Ruido
15.
Dentomaxillofac Radiol ; 46(1): 20160280, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27704872

RESUMEN

OBJECTIVES: To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. METHODS: Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. RESULTS: TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). CONCLUSIONS: MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Articulación Temporomandibular/diagnóstico por imagen , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Estudios Prospectivos , Relación Señal-Ruido
16.
Eur J Radiol ; 85(11): 1948-1955, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27776645

RESUMEN

PURPOSE: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. MATERIALS AND METHODS: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). RESULTS: In scheme (i) no differences in SNR were observed (p=0.321-0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. CONCLUSION: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Hígado/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Relación Señal-Ruido , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados , Factores de Tiempo
17.
NMR Biomed ; 29(6): 767-75, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27061811

RESUMEN

Diffusional kurtosis MRI (DKI) quantifies the deviation of water diffusion from a Gaussian distribution. We investigated the influence of passive elongation and shortening of the lower leg muscles on the DKI parameters D (diffusion coefficient) and K (kurtosis). After approval by the local ethics committee, eight healthy volunteers (age, 29.1 ± 2.9 years) underwent MRI of the lower leg at 3 T. Diffusion-weighted images were acquired with 10 different b values at three ankle positions (passive dorsiflexion 10°, neutral position 0°, passive plantar flexion 40°). Parametrical maps of D and K were obtained by voxel-wise fitting of the signal intensities using a non-linear Levenberg-Marquardt algorithm. D and K were measured in the tibialis anterior, medial and lateral gastrocnemius, and soleus muscles. In the neutral position, D and K values were in the range between 1.66-1.79 × 10(-3) mm(2) /s and 0.21-0.39, respectively. D and K increased with passive shortening, and decreased with passive elongation, which could also be illustrated on the parametrical maps. In dorsiflexion, D (p < 0.01) and K (p = 0.036) were higher in the tibialis anterior than in the medial gastrocnemius. In plantar flexion, the opposite was found for K (p = 0.035). DKI parameters in the lower leg muscles are significantly influenced by the ankle joint position, indicating that the diffusion of water molecules in skeletal muscle deviates from a Gaussian distribution depending on muscle tonus. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/fisiología , Imagen de Difusión por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Adulto , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Pierna , Masculino , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
MAGMA ; 29(5): 751-63, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27094553

RESUMEN

OBJECTIVE: Diffusion-weighted magnetic resonance imaging (DW-MRI) combined with intravoxel incoherent motion (IVIM) analysis may be applied for assessment of organ lesions, diffuse parenchymal pathologies, and therapy monitoring. The aim of this study was to determine IVIM reference parameters of abdominal organs for translational research in a large cohort of C57Bl/6 laboratory mice. MATERIALS AND METHODS: Anesthetized mice (n = 29) were measured in a 4.7 T small-animal MR scanner with a diffusion-weighted echo-planar imaging sequence at the [Formula: see text]-values 0, 13, 24, 55, 107, 260, 514, 767, 1020 s/mm(2). IVIM analysis was conducted on the liver, spleen, renal medulla and cortex, pancreas, and small bowel with computation of the true tissue diffusion coefficient [Formula: see text], the perfusion fraction [Formula: see text], and the pseudodiffusion coefficient [Formula: see text]. Microvessel density (MVD) was assessed by immunohistochemistry (IHC) against panendothelial cell antigen CD31. RESULTS: Mean values of the different organs [[Formula: see text] (10(-3) mm(2)/s); [Formula: see text] (%); [Formula: see text] (10(-3) mm(2)/s); MVD (MV/mm(2))]: liver 1.15 ± 0.14; 14.77 ± 6.15; 50.28 ± 33.21, 2008.48 ± 419.43, spleen 0.55 ± 0.12; 9.89 ± 5.69; 24.46 ± 17.31; n.d., renal medulla 1.50 ± 0.20; 14.63 ± 4.07; 35.50 ± 18.01; 1231.88 ± 290.61, renal cortex 1.34 ± 0.18; 10.83 ± 3.70; 16.74 ± 6.74; 810.09 ± 193.50, pancreas 1.23 ± 0.22; 20.12 ± 7.46; 29.35 ± 17.82, 591.15 ± 86.25 and small bowel 1.06 ± 0.13; 16.48 ± 3.63; 15.31 ± 7.00; 420.50 ± 168.42. Unlike [Formula: see text] and [Formula: see text], [Formula: see text] correlates significantly with MVD (r = 0.90, p = 0.037). CONCLUSION: This systematic evaluation of murine abdominal organs with IVIM and MVD analysis allowed to establish reference parameters for future DW-MRI translational research studies on small-animal disease models.


Asunto(s)
Abdomen/diagnóstico por imagen , Microcirculación , Movimiento (Física) , Abdomen/patología , Animales , Difusión , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Inmunohistoquímica , Intestino Delgado/diagnóstico por imagen , Riñón/diagnóstico por imagen , Hígado/diagnóstico por imagen , Ratones , Ratones Endogámicos C57BL , Microvasos , Páncreas/diagnóstico por imagen , Perfusión , Molécula-1 de Adhesión Celular Endotelial de Plaqueta/metabolismo , Bazo/diagnóstico por imagen
19.
Dentomaxillofac Radiol ; 45(4): 20150420, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26837671

RESUMEN

OBJECTIVE: To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using a standard TMJ surface coil and a head coil at 3.0 T. METHODS: 22 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) and a 32-channel head coil at 3.0 T (Philips Ingenia; Philips Healthcare, Netherlands). Imaging protocol consisted of an oblique sagittal proton density weighted turbo spin echo sequence (repetition time/echo time, 2700/26 ms). For quantitative assessment, a spherical phantom was imaged using the same sequence including a noise scan and a B1+ scan. Signal-to-noise ratio (SNR) maps and B1+ maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of both TMJs with the jaw in the closed position. Two independent blinded readers assessed accuracy of TMJ anatomical representation and overall image quality on a 5-point scale. Quantitative and qualitative measurements were compared between coils using t-tests and Wilcoxon signed-rank test, respectively. RESULTS: Quantitative analysis showed similar B1+ and significantly higher SNR for the head coil than the TMJ surface coil. Qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the articular disc, bilaminar zone and lateral pterygoid muscle. Furthermore, better overall image quality was observed for the head coil than for the TMJ surface coil. CONCLUSIONS: A 32-channel head coil is preferable to a standard 2-channel TMJ surface coil when imaging the TMJ at 3.0 T, because it yields higher SNR, thus increasing accuracy of the anatomical representation of the TMJ.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Articulación Temporomandibular/anatomía & histología , Adulto , Cartílago Articular/anatomía & histología , Diseño de Equipo , Femenino , Humanos , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Músculos Pterigoideos/anatomía & histología , Relación Señal-Ruido , Disco de la Articulación Temporomandibular/anatomía & histología , Adulto Joven
20.
Eur J Radiol ; 85(1): 131-135, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26724657

RESUMEN

PURPOSE: To assess differences in fat signal fraction (FSF) in skeletal muscle as determined by two-point Dixon technique at 3T before and after application of intravenous gadoterate meglumide (Gd-DOTA). MATERIALS AND METHODS: Eight patients (mean age, 50.8 years; range, 41-72 years) underwent clinical whole-body MRI at 3T for myopathic symptoms. Two-point Dixon technique based T1-weighted turbo spin-echo images were acquired before and after the administration of intravenous Gd-DOTA. On both image sets, the FSF was calculated in the gluteus medius, gluteus maximus, and quadriceps muscles bilaterally. Pre- and post-contrast FSF values were compared by linear regression, Bland-Altman plot as well as paired Student t-tests with Bonferroni correction. RESULTS: The mean pre- and post-contrast FSF of included muscles were 28.7%±14.9% and 27.8%±15.1%, respectively. Linear regression indicated almost equivalent FSF estimation between pre- and post-contrast measurements (sum of squared residuals R(2), 0.92±0.04; slope, 0.97; X-intercept, -0.05; Y-intercept, +0.05). The Bland-Altman plot revealed a minimal systematical bias of the post-contrast FSF measurements of -0.87%. Paired Student t-tests did not reveal significant differences (overall p-value, 0.168). CONCLUSION: Gd-DOTA does not significantly influence FSF quantification in skeletal muscle based on the two-point Dixon technique at 3T.


Asunto(s)
Medios de Contraste/administración & dosificación , Compuestos Heterocíclicos/administración & dosificación , Imagen por Resonancia Magnética , Músculo Esquelético/patología , Compuestos Organometálicos/administración & dosificación , Adiposidad , Adulto , Anciano , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Inyecciones Intravenosas , Modelos Lineales , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA