Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med ; 88: 104-110, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34218199

RESUMEN

PURPOSE: Respiration-induced tumor or organ positional changes can impact the accuracy of external beam radiotherapy. Motion management strategies are used to account for these changes during treatment. The authors report on the development, testing, and first-in-human evaluation of an electronic 4D (e4D) MR-compatible ultrasound probe that was designed for hands-free operation in a MR and linear accelerator (LINAC) environment. METHODS: Ultrasound components were evaluated for MR compatibility. Electromagnetic interference (EMI) shielding was used to enclose the entire probe and a factory-fabricated cable shielded with copper braids was integrated into the probe. A series of simultaneous ultrasound and MR scans were acquired and analyzed in five healthy volunteers. RESULTS: The ultrasound probe led to minor susceptibility artifacts in the MR images immediately proximal to the ultrasound probe at a depth of <10 mm. Ultrasound and MR-based motion traces that were derived by tracking the salient motion of endogenous target structures in the superior-inferior (SI) direction demonstrated good concordance (Pearson correlation coefficients of 0.95-0.98) between the ultrasound and MRI datasets. CONCLUSION: We have demonstrated that our hands-free, e4D probe can acquire ultrasound images during a MR acquisition at frame rates of approximately 4 frames per second (fps) without impacting either the MR or ultrasound image quality. This use of this technology for interventional procedures (e.g. biopsies and drug delivery) and motion compensation during imaging are also being explored.


Asunto(s)
Imagen por Resonancia Magnética , Respiración , Electrónica , Humanos , Movimiento (Física) , Fantasmas de Imagen , Ultrasonografía
2.
IEEE Netw ; 20172017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31452579

RESUMEN

We developed a magnetic resonance compatible real-time, three-dimensional imaging ultrasound probe for motion management of radiation therapy for liver cancer. The probe contains an 18,000-element, 46.8 mm × 21.5 mm matrix array constructed from three tiled transducer modules with integrated beamforming ASICs. The center frequency and -6 dB fractional bandwidth of the probe was 3.6 MHz and 85 percent respectively. Ferromagnetic materials in the acoustic stack, flex interconnect and electronics boards were greatly minimized for magnetic resonance compatibility. The probe and cable were shielded to minimize the impact of radiofrequency noise on both the ultrasound and magnetic resonance images. The probe's low-profile, side-viewing design allows it to be strapped to a patient so that images may be acquired hands-free. We present simultaneously acquired ultrasound and 3 Tesla magnetic resonance images with minimal artifacts in both images.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...