Magn Reson Med ; 91(2): 640-648, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37753628

RESUMEN

PURPOSE: To demonstrate the technical feasibility and the value of ultrahigh-performance gradient in imaging the prostate in a 3T MRI system. METHODS: In this local institutional review board-approved study, prostate MRI was performed on 4 healthy men. Each subject was scanned in a prototype 3T MRI system with a 42-cm inner-diameter gradient coil that achieves a maximum gradient amplitude of 200 mT/m and slew rate of 500 T/m/s. PI-RADS V2.1-compliant axial T2 -weighted anatomical imaging and single-shot echo planar DWI at standard gradient of 70 mT/m and 150 T/m/s were obtained, followed by DWI at maximum performance (i.e., 200 mT/m and 500 T/m/s). In comparison to state-of-the-art clinical whole-body MRI systems, the high slew rate improved echo spacing from 1020 to 596 µs and, together with a high gradient amplitude for diffusion encoding, TE was reduced from 55 to 36 ms. RESULTS: In all 4 subjects (waist circumference = 81-91 cm, age = 45-65 years), no peripheral nerve stimulation sensation was reported during DWI. Reduced image distortion in the posterior peripheral zone prostate gland and higher signal intensity, such as in the surrounding muscle of high-gradient DWI, were noted. CONCLUSION: Human prostate MRI at simultaneously high gradient amplitude of 200 mT/m and slew rate of 500 T/m/s is feasible, demonstrating that improved gradient performance can address image distortion and T2 decay-induced SNR issues for in vivo prostate imaging.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Masculino , Humanos , Persona de Mediana Edad , Anciano , Próstata/diagnóstico por imagen , Estudios de Factibilidad , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
2.
Neuroimage ; 279: 120328, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37586445

RESUMEN

Measuring the time/frequency dependence of diffusion MRI is a promising approach to distinguish between the effects of different tissue microenvironments, such as membrane restriction, tissue heterogeneity, and compartmental water exchange. In this study, we measure the frequency dependence of diffusivity (D) and kurtosis (K) with oscillating gradient diffusion encoding waveforms and a diffusion kurtosis imaging (DKI) model in human brains using a high-performance, head-only MAGNUS gradient system, with a combination of b-values, oscillating frequencies (f), and echo time that has not been achieved in human studies before. Frequency dependence of diffusivity and kurtosis are observed in both global and local white matter (WM) and gray matter (GM) regions and characterized with a power-law model ∼Λ*fθ. The frequency dependences of diffusivity and kurtosis (including changes between fmin and fmax, Λ, and θ) vary over different WM and GM regions, indicating potential microstructural differences between regions. A trend of decreasing kurtosis over frequency in the short-time limit is successfully captured for in vivo human brains. The effects of gradient nonlinearity (GNL) on frequency-dependent diffusivity and kurtosis measurements are investigated and corrected. Our results show that the GNL has prominent scaling effects on the measured diffusivity values (3.5∼5.5% difference in the global WM and 6∼8% difference in the global cortex) and subsequently affects the corresponding power-law parameters (Λ, θ) while having a marginal influence on the measured kurtosis values (<0.05% difference) and power-law parameters (Λ, θ). This study expands previous OGSE studies and further demonstrates the translatability of frequency-dependent diffusivity and kurtosis measurements to human brains, which may provide new opportunities to probe human brain microstructure in health and disease.


Asunto(s)
Imagen de Difusión Tensora , Sustancia Blanca , Humanos , Imagen de Difusión Tensora/métodos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen , Sustancia Gris/diagnóstico por imagen
3.
Int J Hyperthermia ; 39(1): 1283-1293, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36162814

RESUMEN

BACKGROUND: In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied. OBJECTIVE: We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis. METHODS: Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data. RESULTS: Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n - 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue. CONCLUSION: We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.


Asunto(s)
Encéfalo , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Proteína Ácida Fibrilar de la Glía , Hígado , Imagen por Resonancia Magnética/métodos , Porcinos
4.
Int J Hyperthermia ; 38(1): 907-915, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34148489

RESUMEN

BACKGROUND: High-intensity focused ultrasound (HIFU) serves as a noninvasive stereotactic system for the ablation of brain metastases; however, treatments are limited to simple geometries and energy delivery is limited by the high acoustic attenuation of the calvarium. Minimally-invasive magnetic resonance-guided robotically-assisted (MRgRA) needle-based therapeutic ultrasound (NBTU) using multislice volumetric 2-D magnetic resonance thermal imaging (MRTI) overcomes these limitations and has potential to produce less collateral tissue damage than current methods. OBJECTIVE: To correlate multislice volumetric 2-D MRTI volumes with histologically confirmed regions of tissue damage in MRgRA NBTU. METHODS: Seven swine underwent a total of 8 frontal MRgRA NBTU lesions. MRTI ablation volumes were compared to histologic tissue damage on brain sections stained with 2,3,5-triphenyltetrazolium chloride (TTC). Bland-Altman analyses and correlation trends were used to compare MRTI and TTC ablation volumes. RESULTS: Data from the initial and third swine's ablations were excluded due to sub-optimal tissue staining. For the remaining ablations (n = 6), the limits of agreement between the MRTI and histologic volumes ranged from -0.149 cm3 to 0.252 cm3 with a mean difference of 0.052 ± 0.042 cm3 (11.1%). There was a high correlation between the MRTI and histology volumes (r2 = 0.831) with a strong linear relationship (r = 0.868). CONCLUSION: We used a volumetric MRTI technique to accurately track thermal changes during MRgRA NBTU in preparation for human trials. Improved volumetric coverage with MRTI enhanced our delivery of therapy and has far-reaching implications for focused ultrasound in the broader clinical setting.


Asunto(s)
Neoplasias Encefálicas , Ultrasonido Enfocado de Alta Intensidad de Ablación , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Porcinos
5.
Neurosurgery ; 88(2): 356-365, 2021 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-32985661

RESUMEN

BACKGROUND: Models have been developed for predicting ideal contact and amplitude for subthalamic nucleus (STN) deep brain stimulation (DBS) for Parkinson disease (PD). Pulse-width is generally varied to modulate the size of the energy field produced. Effects of varying frequency in humans have not been systematically evaluated. OBJECTIVE: To examine how altered frequencies affect blood oxygen level-dependent activation in PD. METHODS: PD subjects with optimized DBS programming underwent functional magnetic resonance imaging (fMRI). Frequency was altered and fMRI scans/Unified Parkinson Disease Rating Scale motor subunit (UPDRS-III) scores were obtained. Analysis using DBS-OFF data was used to determine which regions were activated during DBS-ON. Peak activity utilizing T-values was obtained and compared. RESULTS: At clinically optimized settings (n = 14 subjects), thalamic, globus pallidum externa (GPe), and posterior cerebellum activation were present. Activation levels significantly decreased in the thalamus, anterior cerebellum, and the GPe when frequency was decreased (P < .001). Primary somatosensory cortex activation levels significantly decreased when frequency was increased by 30 Hz, but not 60 Hz. Sex, age, disease/DBS duration, and bilaterality did not significantly affect the data. Retrospective analysis of fMRI activation patterns predicted optimal frequency in 11/14 subjects. CONCLUSION: We show the first data with fMRI of STN DBS-ON while synchronizing cycling with magnetic resonance scanning. At clinically optimized settings, an fMRI signature of thalamic, GPe, and posterior cerebellum activation was seen. Reducing frequency significantly decreased thalamic, GPe, and anterior cerebellum activation. Current standard-of-care programming can take up to 6 mo using UPDRS-III testing alone. We provide preliminary evidence that using fMRI signature of frequency may have clinical utility and feasibility.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Estimulación Encefálica Profunda/métodos , Imagen por Resonancia Magnética/métodos , Enfermedad de Parkinson/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
IEEE Trans Biomed Eng ; 68(6): 1838-1846, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32924937

RESUMEN

The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was 1.27 °C. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.


Asunto(s)
Imagen por Resonancia Magnética , Terapia por Ultrasonido , Animales , Fantasmas de Imagen , Rotación , Porcinos , Ultrasonografía
8.
Neuromodulation ; 23(4): 515-524, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32369255

RESUMEN

BACKGROUND: Deep brain stimulation (DBS) is a well-accepted treatment of Parkinson's disease (PD). Motor phenotypes include tremor-dominant (TD), akinesia-rigidity (AR), and postural instability gait disorder (PIGD). The mechanism of action in how DBS modulates motor symptom relief remains unknown. OBJECTIVE: Blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) was used to determine whether the functional activity varies in response to DBS depending on PD phenotypes. MATERIALS AND METHODS: Subjects underwent an fMRI scan with DBS cycling ON and OFF. The effects of DBS cycling on BOLD activation in each phenotype were documented through voxel-wise analysis. For each region of interest, ANOVAs were performed using T-values and covariate analyses were conducted. Further, a correlation analysis was performed comparing stimulation settings to T-values. Lastly, T-values of subjects with motor improvement were compared to those who worsened. RESULTS: As a group, BOLD activation with DBS-ON resulted in activation in the motor thalamus (p < 0.01) and globus pallidus externa (p < 0.01). AR patients had more activation in the supplementary motor area (SMA) compared to PIGD (p < 0.01) and TD cohorts (p < 0.01). Further, the AR cohort had more activation in primary motor cortex (MI) compared to the TD cohort (p = 0.02). Implanted nuclei (p = 0.01) and phenotype (p = <0.01) affected activity in MI and phenotype alone affected SMA activity (p = <0.01). A positive correlation was seen between thalamic activation and pulse-width (p = 0.03) and between caudate and total electrical energy delivered (p = 0.04). CONCLUSIONS: These data suggest that DBS modulates network activity differently based on patient motor phenotype. Improved understanding of these differences may further our knowledge about the mechanisms of DBS action on PD motor symptoms and to optimize treatment.


Asunto(s)
Encéfalo/fisiopatología , Estimulación Encefálica Profunda/métodos , Enfermedad de Parkinson/terapia , Anciano , Mapeo Encefálico/métodos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Fenotipo
9.
Magn Reson Med ; 83(1): 352-366, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31385628

RESUMEN

PURPOSE: To establish peripheral nerve stimulation (PNS) thresholds for an ultra-high performance magnetic field gradient subsystem (simultaneous 200-mT/m gradient amplitude and 500-T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42-cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks. METHODS: The MAGNUS head gradient was installed in a whole-body 3T scanner with a custom 16-rung bird-cage transmit/receive RF coil compatible with phased-array receiver brain coils. Twenty adult subjects (10 male, mean ± SD age = 40.4 ± 11.1 years) underwent the imaging and PNS study. The tests were repeated by displacing subject positions by 2-4 cm in the superior-inferior and anterior-posterior directions. RESULTS: The x-axis (left-right) yielded mostly facial stimulation, with mean ΔGmin = 111 ± 6 mT/m, chronaxie = 766 ± 76 µsec. The z-axis (superior-inferior) yielded mostly chest/shoulder stimulation (123 ± 7 mT/m, 620 ± 62 µsec). Y-axis (anterior-posterior) stimulation was negligible. X-axis and z-axis thresholds tended to increase with age, and there was negligible dependency with gender. Translation in the inferior and posterior directions tended to increase the x-axis and z-axis thresholds, respectively. Electric field simulations showed good agreement with the PNS results. Imaging at MAGNUS gradient performance with increased PNS threshold provided a 35% reduction in noise-to-diffusion contrast as compared with whole-body performance (80 mT/m gradient amplitude, 200 T/m/sec gradient slew rate). CONCLUSION: The PNS threshold of MAGNUS is significantly higher than that for whole-body gradients, which allows for diffusion gradients with short rise times (under 1 msec), important for interrogating brain microstructure length scales.


Asunto(s)
Encéfalo/diagnóstico por imagen , Estimulación Eléctrica , Campos Magnéticos , Neuroimagen/instrumentación , Neuroimagen/métodos , Nervios Periféricos/diagnóstico por imagen , Sistema Nervioso Periférico/diagnóstico por imagen , Adulto , Algoritmos , Diseño de Equipo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Nervios Periféricos/fisiología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Imagen de Cuerpo Entero
10.
Magn Reson Med ; 83(6): 2356-2369, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31763726

RESUMEN

PURPOSE: To develop a highly efficient magnetic field gradient coil for head imaging that achieves 200 mT/m and 500 T/m/s on each axis using a standard 1 MVA gradient driver in clinical whole-body 3.0T MR magnet. METHODS: A 42-cm inner diameter head-gradient used the available 89- to 91-cm warm bore space in a whole-body 3.0T magnet by increasing the radial separation between the primary and the shield coil windings to 18.6 cm. This required the removal of the standard whole-body gradient and radiofrequency coils. To achieve a coil efficiency ~4× that of whole-body gradients, a double-layer primary coil design with asymmetric x-y axes, and symmetric z-axis was used. The use of all-hollow conductor with direct fluid cooling of the gradient coil enabled ≥50 kW of total heat dissipation. RESULTS: This design achieved a coil efficiency of 0.32 mT/m/A, allowing 200 mT/m and 500 T/m/s for a 620 A/1500 V driver. The gradient coil yielded substantially reduced echo spacing, and minimum repetition time and echo time. In high b = 10,000 s/mm2 diffusion, echo time (TE) < 50 ms was achieved (>50% reduction compared with whole-body gradients). The gradient coil passed the American College of Radiology tests for gradient linearity and distortion, and met acoustic requirements for nonsignificant risk operation. CONCLUSIONS: Ultra-high gradient coil performance was achieved for head imaging without substantial increases in gradient driver power in a whole-body 3.0T magnet after removing the standard gradient coil. As such, any clinical whole-body 3.0T MR system could be upgraded with 3-4× improvement in gradient performance for brain imaging.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Acústica , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Cabeza/diagnóstico por imagen , Humanos , Campos Magnéticos
11.
Radiology ; 293(1): 174-183, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31385756

RESUMEN

BackgroundWith growing numbers of patients receiving deep brain stimulation (DBS), radiologists are encountering these neuromodulation devices at an increasing rate. Current MRI safety guidelines, however, limit MRI access in these patients.PurposeTo describe an MRI (1.5 T and 3 T) experience and safety profile in a large cohort of participants with active DBS systems and characterize the hardware-related artifacts on images from functional MRI.Materials and MethodsIn this prospective study, study participants receiving active DBS underwent 1.5- or 3-T MRI (T1-weighted imaging and gradient-recalled echo [GRE]-echo-planar imaging [EPI]) between June 2017 and October 2018. Short- and long-term adverse events were tracked. The authors quantified DBS hardware-related artifacts on images from GRE-EPI (functional MRI) at the cranial coil wire and electrode contacts. Segmented artifacts were then transformed into standard space to define the brain areas affected by signal loss. Two-sample t tests were used to assess the difference in artifact size between 1.5- and 3-T MRI.ResultsA total of 102 participants (mean age ± standard deviation, 60 years ± 11; 65 men) were evaluated. No MRI-related short- and long-term adverse events or acute changes were observed. DBS artifacts were most prominent near the electrode contacts and over the frontoparietal cortical area where the redundancy of the extension wire is placed subcutaneously. The mean electrode contact artifact diameter was 9.3 mm ± 1.6, and 1.9% ± 0.8 of the brain was obscured by the coil artifact. The coil artifacts were larger at 3 T than at 1.5 T, obscuring 2.1% ± 0.7 and 1.4% ± 0.7 of intracranial volume, respectively (P < .001). The superficial frontoparietal cortex and deep structures neighboring the electrode contacts were most commonly obscured.ConclusionWith a priori local safety testing, patients receiving deep brain stimulation may safely undergo 1.5- and 3-T MRI. Deep brain stimulation hardware-related artifacts only affect a small proportion of the brain.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Martin in this issue.


Asunto(s)
Artefactos , Encéfalo/diagnóstico por imagen , Estimulación Encefálica Profunda/instrumentación , Electrodos Implantados , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Imagen Eco-Planar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
Neurosurgery ; 85(6): E1043-E1049, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31313816

RESUMEN

BACKGROUND: Chronic pain occurs in 83% of Parkinson disease (PD) patients and deep brain stimulation (DBS) has shown to result in pain relief in a subset of patients, though the mechanism is unclear. OBJECTIVE: To compare functional magnetic resonance imaging (MRI) data in PD patients with chronic pain without DBS, those whose pain was relieved (PR) with DBS and those whose pain was not relieved (PNR) with DBS. METHODS: Functional MRI (fMRI) with blood oxygen level-dependent activation data was obtained in 15 patients in control, PR, and PNR patients. fMRI was obtained in the presence and absence of a mechanical stimuli with DBS ON and DBS OFF. Voxel-wise analysis using pain OFF data was used to determine which regions were altered during pain ON periods. RESULTS: At the time of MRI, pain was scored a 5.4 ± 1.2 out of 10 in the control, 4.25 ± 1.18 in PNR, and 0.8 ± 0.67 in PR cohorts. Group analysis of control and PNR groups showed primary somatosensory (SI) deactivation, whereas PR patients showed thalamic deactivation and SI activation. DBS resulted in more decreased activity in PR than PNR (P < .05) and more activity in anterior cingulate cortex (ACC) in PNR patients (P < .05). CONCLUSION: Patients in the control and PNR groups showed SI deactivation at baseline in contrast to the PR patients who showed SI activation. With DBS ON, the PR cohort had less activity in SI, whereas the PNR had more anterior cingulate cortex activity. We provide pilot data that patients whose pain responds to DBS may have a different fMRI signature than those who do not, and PR and PNR cohorts produced different brain responses when DBS is employed.


Asunto(s)
Encéfalo/diagnóstico por imagen , Dolor Crónico , Estimulación Encefálica Profunda , Imagen por Resonancia Magnética , Enfermedad de Parkinson , Dolor Crónico/etiología , Dolor Crónico/terapia , Estudios de Cohortes , Humanos , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/terapia
13.
J Magn Reson Imaging ; 49(6): 1736-1749, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30552842

RESUMEN

BACKGROUND: The majority of Parkinson's disease patients with deep brain stimulation (DBS) use a monopolar configuration, which presents challenges for EEG and MRI studies. The literature reports algorithms to convert monopolar to bipolar settings. PURPOSE/HYPOTHESIS: To assess brain responses of Parkinson's disease patients implanted with DBS during fMRI studies using their clinical and presumed equivalent settings using a published conversion recipe. STUDY TYPE: Prospective. SUBJECTS: Thirteen DBS patients. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, fMRI using gradient echo-planar imaging. ASSESSMENT: Patients underwent 30/30sec ON/OFF DBS fMRI scans using monopolar and bipolar settings. To convert to a bipolar setting, the negative contact used for the monopolar configuration remained constant and the adjacent dorsal contact was rendered positive, while increasing the voltage by 30%. fMRI activation/deactivation maps and motor Unified Parkinson's Disease Rating Scale (UPDRS-III) scores were compared for patients in both configurations. STATISTICAL TESTS: T-tests were used to compare UPDRS scores and volumes of tissue activated (VTA) diameters in monopolar and bipolar configurations. RESULTS: The patterns of fMRI activation in the monopolar and bipolar configurations were generally different. The thalamus, pallidum, and visual cortices exhibited higher activation using the patient's clinical settings than the presumed equivalent settings. VTA diameters were lower (7 mm vs. 6.3 mm, P = 0.047) and UPDRS scores were generally higher in the bipolar (33.2 ± 16) than in the monopolar configuration (28.3 ± 17.4), without reaching statistical significance (P > 0.05). DATA CONCLUSION: Monopolar and bipolar configurations result in different patterns of brain activation while using a previously published monopolar-bipolar conversion algorithm. Clinical benefits may be achieved with varying patterns of brain responses. Blind conversion from one to the other should be avoided for purposes of understanding the mechanisms of DBS. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.


Asunto(s)
Encéfalo/diagnóstico por imagen , Estimulación Encefálica Profunda/instrumentación , Imagen Eco-Planar , Imagen por Resonancia Magnética , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/terapia , Anciano , Algoritmos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos
14.
J Magn Reson ; 295: 72-79, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30144687

RESUMEN

Test disk electrodes were fabricated from carbon nanotubes (CNT) using the Carbon Nanotube Templated Microfabrication (CNT-M) technique. The CNT-M process uses patterned growth of carbon nanotube forests from surfaces to form complex patterns, enabling electrode sizing and shaping. The additional carbon infiltration process stabilizes these structures for further processing and handling. At a macroscopic scale, the electrochemical, electrical and magnetic properties, and magnetic resonance imaging (MRI) characteristics of the disk electrodes were investigated; their microstructure was also assessed. CNT disk electrodes showed electrical resistivity around 1â€¯Ω·cm, charge storage capacity between 3.4 and 38.4 mC/cm2, low electrochemical impedance and magnetic susceptibility of -5.9 to -8.1 ppm, closely matched to that of tissue (∼-9 ppm). Phantom MR imaging experiments showed almost no distortion caused by these electrodes compared with Cu and Pt-Ir reference electrodes, indicating the potential for significant improvement in accurate tip visualization.

15.
Magn Reson Med ; 80(5): 2232-2245, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29536587

RESUMEN

PURPOSE: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. METHODS: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. RESULTS: In a comparison of anatomical imaging in 16 patients using T2 -weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. CONCLUSIONS: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen de Cuerpo Entero/instrumentación , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Imagenología Tridimensional , Imanes , Masculino , Fantasmas de Imagen , Relación Señal-Ruido
16.
Magn Reson Med ; 79(4): 2432-2439, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28766824

RESUMEN

PURPOSE: To assess the impact of synchronization errors between the assumed functional MRI paradigm timing and the deep brain stimulation (DBS) on/off cycling using a custom electrocardiogram-based triggering system METHODS: A detector for measuring and predicting the on/off state of cycling deep brain stimulation was developed and tested in six patients in office visits. Three-electrode electrocardiogram measurements, amplified by a commercial bio-amplifier, were used as input for a custom electronics box (e-box). The e-box transformed the deep brain stimulation waveforms into transistor-transistor logic pulses, recorded their timing, and propagated it in time. The e-box was used to trigger task-based deep brain stimulation functional MRI scans in 5 additional subjects; the impact of timing accuracy on t-test values was investigated in a simulation study using the functional MRI data. RESULTS: Following locking to each patient's individual waveform, the e-box was shown to predict stimulation onset with an average absolute error of 112 ± 148 ms, 30 min after disconnecting from the patients. The subsecond accuracy of the e-box in predicting timing onset is more than adequate for our slow varying, 30-/30-s on/off stimulation paradigm. Conversely, the experimental deep brain stimulation onset prediction accuracy in the absence of the e-box, which could be off by as much as 4 to 6 s, could significantly decrease activation strength. CONCLUSIONS: Using this detector, stimulation can be accurately synchronized to functional MRI acquisitions, without adding any additional hardware in the MRI environment. Magn Reson Med 79:2432-2439, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Estimulación Encefálica Profunda , Electrocardiografía , Imagen por Resonancia Magnética , Enfermedad de Parkinson/diagnóstico por imagen , Algoritmos , Encéfalo/diagnóstico por imagen , Electrodos , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Núcleo Subtalámico/diagnóstico por imagen
17.
IEEE Netw ; 20172017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31452579

RESUMEN

We developed a magnetic resonance compatible real-time, three-dimensional imaging ultrasound probe for motion management of radiation therapy for liver cancer. The probe contains an 18,000-element, 46.8 mm × 21.5 mm matrix array constructed from three tiled transducer modules with integrated beamforming ASICs. The center frequency and -6 dB fractional bandwidth of the probe was 3.6 MHz and 85 percent respectively. Ferromagnetic materials in the acoustic stack, flex interconnect and electronics boards were greatly minimized for magnetic resonance compatibility. The probe and cable were shielded to minimize the impact of radiofrequency noise on both the ultrasound and magnetic resonance images. The probe's low-profile, side-viewing design allows it to be strapped to a patient so that images may be acquired hands-free. We present simultaneously acquired ultrasound and 3 Tesla magnetic resonance images with minimal artifacts in both images.

18.
Magn Reson Med ; 76(6): 1939-1950, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-26628078

RESUMEN

PURPOSE: To characterize peripheral nerve stimulation (PNS) of an asymmetric head-only gradient coil that is compatible with a commercial high-channel-count receive-only array. METHODS: Two prototypes of an asymmetric head-only gradient coil set with a 42-cm inner diameter were constructed for brain imaging at 3T with maximum performance specifications of up to 85 mT/m and 708 T/m/s. Tests were performed in 24 volunteers to measure PNS thresholds with the transverse (x = left-right; y = anterior-posterior [A/P]) gradient coils of both prototypes. Fourteen of these 24 volunteers were also tested for the z-gradient PNS in the second prototype and were scanned with high-slew-rate echo planar imaging (EPI) immediately after the PNS tests. RESULTS: For both prototypes, the y-gradient PNS threshold was markedly higher than the x-gradient threshold. The z-gradient threshold was intermediate between those for the x- and y-coils. Of the 24 volunteers, only two experienced y-gradient PNS at 80 mT/m and 500 T/m/s. All volunteers underwent the EPI scan without PNS when the readout direction was set to A/P. CONCLUSION: Measured PNS characteristics of asymmetric head-only gradient coil prototypes indicate that such coils, especially in the A/P direction, can be used for fast EPI readout in high-performance neuroimaging scans with substantially reduced PNS concerns compared with conventional whole body gradient coils. Magn Reson Med 76:1939-1950, 2016. © 2015 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/fisiología , Terapia por Estimulación Eléctrica/instrumentación , Neuroestimuladores Implantables , Imagen por Resonancia Magnética/instrumentación , Nervios Periféricos/fisiología , Encéfalo/anatomía & histología , Terapia por Estimulación Eléctrica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Magn Reson Med ; 75(2): 897-905, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25772214

RESUMEN

PURPOSE: To design, build, and characterize the performance of a novel 3T, 31-channel breast coil. METHODS: A flexible breast coil, accommodating all breast sizes while preserving close to unity filling factors in all configurations, was designed and built. Its performance was compared to the performance of the current state-of-the-art, 16 channel breast coil (Sentinelle coil, Hologic, Bedford, MA, USA), in phantoms and in vivo. RESULTS: Better axilla coverage and lower inter-coil coupling (12% versus 26%, as characterized by the average off-diagonal elements of the noise correlation matrix) was exhibited by our 31-channel coil compared with the 16-channel coil. Breast area signal-to-noise ratio increases of 68% (phantom) and 28% ± 31% (in vivo) were observed when the 31-channel coil was used. For the 31-channel/16-channel arrays, respectively, two-dimensional acceleration factors of left/right × superior/inferior = 4.3 × 2.4 resulted in average g-factors of 1.10/1.68 (in vitro) and 1.28/2.75 (in vivo); acceleration factors of left/right × anterior/posterior = 3.0 × 2.8 resulted in average g-factors of 1.06/1.54 (in vitro) and 1.05/1.12 (in vivo). CONCLUSION: A high performance breast coil was built; its capabilities were demonstrated in phantom and normal volunteer imaging experiments.


Asunto(s)
Mama/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Femenino , Voluntarios Sanos , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
20.
Int J Hyperthermia ; 30(3): 184-91, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24773040

RESUMEN

Magnetic resonance thermometry (MRT) offers non-invasive temperature imaging and can greatly contribute to the effectiveness of head and neck hyperthermia. We therefore wish to redesign the HYPERcollar head and neck hyperthermia applicator for simultaneous radio frequency (RF) heating and magnetic resonance thermometry. In this work we tested the feasibility of this goal through an exploratory experiment, in which we used a minimally modified applicator prototype to heat a neck model phantom and used an MR scanner to measure its temperature distribution. We identified several distorting factors of our current applicator design and experimental methods to be addressed during development of a fully MR compatible applicator. To allow MR imaging of the electromagnetically shielded inside of the applicator, only the lower half of the HYPERcollar prototype was used. Two of its antennas radiated a microwave signal (150 W, 434 MHz) for 11 min into the phantom, creating a high gradient temperature profile (ΔTmax = 5.35 °C). Thermal distributions were measured sequentially, using drift corrected proton resonance frequency shift-based MRT. Measurement accuracy was assessed using optical probe thermometry and found to be about 0.4 °C (0.1-0.7 °C). Thermal distribution size and shape were verified by thermal simulations and found to have a good correlation (r(2 )= 0.76).


Asunto(s)
Neoplasias de Cabeza y Cuello/terapia , Hipertermia Inducida , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Neoplasias de Cabeza y Cuello/patología , Humanos , Protones