Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Mosq Control Assoc ; 27(1): 61-8, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21476449

RESUMEN

In 2008 and 2009, our current thermal fogging methods and materials were evaluated in underground systems against feral and laboratory strains of adult Culex quinquefasciatus. Culex quinquefasciatus adults collected from storm drain systems the night before treatment were tested concurrently with adults from a susceptible laboratory strain (Sebring) in 10 separate tests. During 2008, there were no significant differences in the low mean percent control obtained between any of the feral populations (29.39%) and susceptible (Sebring) populations (56.04%) tested, whereas in 2009, application of mineral oil alone yielded extremely low, but significantly different mean percent control at 0.99% for ferals and 0.01% for Sebrings. During 2009 mineral oil evaluations, 45,677 droplets were collected in storm drains at distances of 99.1, 50.6, 57.9, 67.7, and 109.7 m from the application site, with 99% of the droplets below 3 microm in diam; additionally, we found no significant differences between mean percent control of Sebring and feral mosquito populations using the higher (3.2x) 1:10 application rate of Pyrocide. However, mean percent control between the feral and susceptible strain (Sebring) during 2009 was lower than in 2008 at 16.55% for ferals and 24.43% in Sebrings. Results indicated that control methodologies and/or chemicals used were ineffective at controlling Cx. quinquefasciatus in storm drains using the chosen experimental design. Based upon this information, thermal fog operations were discontinued due to lack of effectiveness.


Asunto(s)
Aerosoles , Culex , Insecticidas , Control de Mosquitos/métodos , Butóxido de Piperonilo , Piretrinas , Animales , Drenaje de Agua , Aceite Mineral , Control de Mosquitos/instrumentación , Texas
2.
J Am Mosq Control Assoc ; 24(3): 463-4, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18939705

RESUMEN

A multiunit CO2 delivery and anesthetizing system that supports expanded cage testing of mosquitoes is described. This system has proven more efficient than pipetting for conducting multiple tests and has facilitated the tripling of cage testing capabilities.


Asunto(s)
Anestesia , Dióxido de Carbono/administración & dosificación , Culex , Animales , Femenino , Insecticidas , Pruebas de Toxicidad/instrumentación
3.
J Am Mosq Control Assoc ; 23(2): 237-9, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17847862

RESUMEN

A wind-sensitive vane apparatus was designed and implemented specifically to accommodate the attachment of otherwise unidirectional insecticide treatment cages used in ground ultra-low volume mosquito adulticide field tests. This cage support system is useful in keeping the potential West Nile virus and St. Louis encephalitis vector Culex quinquefasciatus caged mosquitoes oriented into the wind during field efficacy tests. Testing capacity for resistance surveillance was tripled during the 2005 season, and more reliable results were achieved as a consequence.


Asunto(s)
Culicidae/efectos de los fármacos , Insecticidas/farmacología , Control de Mosquitos/instrumentación , Control de Mosquitos/métodos , Animales , Texas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...