Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Unfallchirurgie (Heidelb) ; 127(5): 391-402, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38619616

RESUMEN

Head injuries are frequent occurrences in emergency departments worldwide and are notable for the fact that attention must be paid to the sequelae of intracranial and extracranial trauma. It is crucial to assess potential intracranial injuries and to strive for both medically sound and esthetically pleasing extracranial outcomes. The aim of this continuing education article is to provide a refresher on knowledge of head injuries and the associated nuances for wound care.


Asunto(s)
Traumatismos Craneocerebrales , Humanos , Traumatismos Craneocerebrales/complicaciones , Traumatismos Craneocerebrales/cirugía , Traumatismos Craneocerebrales/terapia , Neurocirugia , Lesiones Traumáticas del Encéfalo/terapia
3.
Br J Radiol ; 96(1148): 20211408, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37334789

RESUMEN

OBJECTIVES: To investigate the interdisciplinary interobserver reproducibility of Hertel-exophthalmometry-like protrusion measurements on multidetector-row-computed-tomography- (MDCT-) images of the orbit to facilitate structured evaluation of the orbit and mid-face. METHODS: Respective reproducibility of base-length along the interfronto-zygomatic line, right and left ocular protrusion, and deriving interocular difference was measured in this retrospective (04/2009-03/2020) single-centre observational study. MDCT-series and slice-positions were selected independently, using picture-archiving-and-communication-system- (PACS-) tools on tilt-corrected axial MDCT-images (slice-thickness 0.6-3.0 mm, window/centre 350/50 HU) in 37 selected adult patients (24 female, age 57 ± 13 years, average±standard-deviation) with clinical indication for Hertel-exophthalmometry, by one radiology-attending, two ophthalmology-attendings, one critical-care-attending, and one ear-nose-throat-surgery resident, respectively. Bland-Altman plots and Wilcoxon-matched-pairs-signed-rank-tests compared interobserver results. RESULTS: Mean and median interobserver and intraobserver (radiology-attending) deviations were within 1 mm of respective averages of base-length (98 ± 4 mm), right and left ocular protrusion (21 ± 4 mm) and interocular difference (2 ± 1 mm). Relative interobserver deviations were within 2.0% of average (all patients) for base-length, and 5.0% (>80% of patients) for ocular protrusion. Pairwise interobserver comparison showed no significant differences between interocular differences of protrusion. CONCLUSIONS: Respective measurements of base-length, ocular protrusion, and deriving interocular difference show high interdisciplinary interobserver reproducibility in tilt-corrected axial MDCT-images of the orbit or mid-face. ADVANCES IN KNOWLEDGE: Hertel-exophthalmometry-like protrusion measurements did not depend on the years of experience or the medical subspecialty of the observer. Measurements are objective, well reproducible and important for multiple medical disciplines and should thus be included in pertinent radiology reports.


Asunto(s)
Exoftalmia , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Exoftalmia/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Técnicas de Diagnóstico Oftalmológico , Tomografía Computarizada Multidetector , Variaciones Dependientes del Observador
4.
Eur Arch Otorhinolaryngol ; 279(6): 2845-2855, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34318333

RESUMEN

OBJECTIVES: In pediatric audiology, objective techniques for hearing threshold estimation in infants and children with profound or severe hearing loss play a key role. Auditory brainstem responses (ABR) and auditory steady-state responses (ASSR) are available for frequency-dependent hearing threshold estimations and both techniques show strong correlations but sometimes with considerable differences. The aim of the study was to compare hearing threshold estimations in children with and without cochlear and cochlear nerve malformations. METHODS: Two groups with profound or severe hearing loss were retrospectively compared. In 20 ears (15 children) with malformation of the inner ear and/or cochlear nerve hypoplasia and a control group of 20 ears (11 children) without malformation, ABR were measured with the Interacoustics Eclipse EP25 ABR system® (Denmark) with narrow-band CE-chirps® at 500, 1000, 2000 and 4000 Hz and compared to ASSR at the same center frequencies under similar conditions. RESULTS: ABR and ASSR correlated significantly in both groups (r = 0.413 in malformation group, r = 0.82 in control group). The malformation group showed a significantly lower percentage of "equal" hearing threshold estimations than the control group. In detail, patients with isolated cochlear malformation did not differ significantly from the control group, whereas patients with cochlear nerve hypoplasia showed significantly greater differences. CONCLUSION: ABR and ASSR should be used jointly in the diagnostic approach in children with suspected profound or severe hearing loss. A great difference in hearing threshold estimation between these techniques could hint at the involvement of cochlear nerve or cochlear nerve hypoplasia itself.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico , Pérdida Auditiva , Estimulación Acústica/métodos , Umbral Auditivo/fisiología , Niño , Nervio Coclear , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Pérdida Auditiva/diagnóstico , Humanos , Lactante , Estudios Retrospectivos
6.
Injury ; 52(10): 2707-2711, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32033807

RESUMEN

BACKGROUND: Percutaneous sacroiliac (SI) screw fixation is the standard operative treatment of traumatic disruptions to the posterior pelvic ring. The technique offers good outcomes and early postoperative mobilization, which is vital in elderly patients with fragility fractures of the pelvis. While a double-screw technique has been shown to provide optimal biomechanical stability compared to a single-screw construct, anatomic variations and patient-specific characteristics may prevent the safe insertion of two SI screws. We aimed to determine whether cement augmentation of a single SI screw would provide biomechanical stability comparable to that of the double-screw technique. METHODS: Three sacroiliac screw osteosynthesis configurations were tested on 10 human cadaveric pelvis specimens: a single cannulated screw; two cannulated screws; and a single, cement-augmented cannulated screw. Displacement and stiffness of the anterior and posterior pelvic ring after fixation with each technique were measured under axial load. Results where compared using linear regression and paired t-tests. RESULTS: A single uncemented screw offered significantly worse stability in the anterior pelvis compared to a double-screw technique (P < 0.05) and to a single cement-augmented screw technique (P < 0.05). There was no significant difference in anterior pelvic ring stability between the single cement-augmented screw technique and the double-screw technique (P > 0.05). There was no significant difference in the stability of the posterior pelvic ring between the three techniques (P > 0.05). CONCLUSIONS: A single cement-augmented cannulated sacroiliac screw provides biomechanical stability similar to that of a non-augmented double-screw technique in the treatment of posterior pelvic ring fractures.


Asunto(s)
Tornillos Óseos , Huesos Pélvicos , Anciano , Fenómenos Biomecánicos , Cementos para Huesos , Fijación Interna de Fracturas , Humanos , Huesos Pélvicos/cirugía
7.
Eur J Med Res ; 25(1): 26, 2020 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-32682448

RESUMEN

INTRODUCTION: Unstable fractures of the pelvis remain the predominant cause of severe hemorrhage, shock and early death in severely injured patients. The use of pelvic binders has become increasingly popular, particularly in the preclinical setting. There is currently insufficient evidence available about the stability of the pelvic binder versus supraacetabular fixation using 1 or 2 Schanz screws. We aimed to analyze the stability of the pelvic binder and supraacetabular fixateurs using either 1 or 2 Schanz screws in a cadaver model of an induced pelvic B-type fracture. MATERIALS AND METHODS: The study was undertaken in 7 human fresh-frozen cadaveric pelvises with induced AO-type B fractures. Three stabilization techniques were compared: T-POD (pelvic bandage), supraacetabular external fixator with 1 pin on each side and external fixator with 2 pins on each side. Stability and stiffness were analyzed in a biomechanical testing machine using a 5-step protocol with static and dynamic loading, dislocation data were retrieved by ultrasound sensors at the fracture sites. RESULTS: No significant differences in fracture fragment displacement were detected when using either the T-POD, a 1-pin external fixator or a 2-pin external fixator (P > 0.05). The average difference in displacement between the three methods was < 1 mm. CONCLUSIONS: Pelvic binders are suitable for reduction of pelvic B-type fractures. They provide stability comparable to that of supraacetabular fixators, independently of whether 1 or 2 Schanz screws per side are used. Pelvic binders provide sufficient biomechanical stability for transferring patients without the need to first replace them with surgically applied external fixators. However, soft tissue irritation has to be taken into consideration and prolonged wear should be avoided. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Tornillos Óseos , Fijadores Externos , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Acetábulo/lesiones , Acetábulo/cirugía , Adulto , Anciano , Fenómenos Biomecánicos , Femenino , Estudios de Seguimiento , Fracturas Óseas/patología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
8.
Eur Arch Otorhinolaryngol ; 277(2): 463-467, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31686188

RESUMEN

PURPOSE: We assessed the static nasal valve angle with MR imaging in healthy subjects and evaluated the complex mechanism of nasal valve dynamics during physiologic and forced inspiration. METHODS: In 17 healthy subjects, measurements of the static nasal valve angle were conducted on MR scans, using a TSE Axial T2-weighted sequence and a 3 mm slice thickness. The dynamic changes of nasal valve movement were detected using MR Cine-imaging techniques. RESULTS: The static median angle of the nasal valve was found to be 28.6° with a range of 12.7°-39.3°. The median degree of nasal valve collapse during forced inspiration was 68% (range 20-99%) of the baseline (static nasal valve angle). In the moderately forced inspiration (3 s) the median nasal valve angle declined to 76% of the baseline angle (range 42-100%). In the physiologic or unforced inspiration, the median nasal valve angle was reduced to 86.3% of the baseline angle (range 52-100%). CONCLUSION: MRI, as a non-invasive tool, is a reliable method for evaluation of the static nasal valve angle and for the illustration of the complex nasal valve dynamics.


Asunto(s)
Imagen por Resonancia Magnética , Cavidad Nasal/diagnóstico por imagen , Cavidad Nasal/fisiología , Mecánica Respiratoria/fisiología , Adulto , Femenino , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Masculino , Respiración
9.
J Orthop Surg Res ; 14(1): 465, 2019 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-31881914

RESUMEN

BACKGROUND: Incomplete lateral compression fractures (including AO Type B2.1) are among the most common pelvic ring injuries. Although the treatment of choice remains controversial, sacroiliac (SI) screws are commonly used for the operative treatment of incomplete lateral compression fractures of the pelvic ring. However, the disadvantages of SI screws include the risk of nerve root or blood vessel injury. Recently, tape sutures have been found useful as stabilizing material for the treatment of injuries of the syndesmosis, the rotator cuff and knee ligaments. In this current study, we aimed to test the biomechanical feasibility of tape sutures to stabilize the pelvis in the setting of AO Type B2.1 injury. METHODS: Six human cadaveric pelvises underwent cyclic loading to compare the biomechanical stability of different osteosynthesis methods in a B2.1 fracture model. The methods tested in this experiment were a FiberTape® suture and the currently established SI screw. A 3D ultrasound tracking system was used to measure fracture fragment motion. Linear regression was used to model displacement and stiffness at the posterior and anterior pelvic ring. RESULTS: At the posterior fracture site, the FiberTape® demonstrated similar displacement (2.2 ± 0.8 mm) and stiffness (52.2 ± 18.0 N/mm) compared to the sacroiliac screw (displacement 2.1 ± 0.6 mm, P >  0.999; stiffness 50.8 ± 13.0 N/mm, P > 0.999). Considering the anterior fracture site, the FiberTape® again demonstrated similar displacement (3.8 ± 1.3 mm) and stiffness (29.5 ± 9.0 N/mm) compared to the sacroiliac screw (displacement 2.9 ± 0.8 mm, P = 0.2196; stiffness 37.5 ± 11.5 N/mm, P = 0.0711). CONCLUSION: The newly presented osteosynthesis, the FiberTape®, shows promising results for the stabilization of the posterior pelvic ring in AO Type B2.1 lateral compression fractures compared to a sacroiliac screw osteosynthesis based on its minimal-invasiveness and the statistically similar biomechanical properties.


Asunto(s)
Fracturas Óseas/cirugía , Fracturas por Compresión/cirugía , Huesos Pélvicos/lesiones , Cinta Quirúrgica , Suturas , Adulto , Anciano , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Procedimientos Ortopédicos/métodos
10.
Eur Arch Otorhinolaryngol ; 276(2): 619-620, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30778657

RESUMEN

In the original publication, Fig. 1 was incorrectly published with incomplete legends.

11.
Eur Arch Otorhinolaryngol ; 276(1): 27-40, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30306317

RESUMEN

INTRODUCTION: Hydropic ear disease, initially described by and named after Prosper Menière, is one of the most frequent vertigo disorders and one of the most frequent inner ear disorders. It is the syndrome of endolymphatic hydrops which until 2007 could be diagnostically confirmed only by post-mortem histology. In the past, various attempts to formulate clinical diagnostic criteria have been undertaken but were hampered by the inability to ascertain the diagnosis in living patients. With the milestone achievement of endolymphatic hydrops imaging, today the pathology can be ascertained. In this study, we have performed a detailed analysis of the clinical features of hydropic ear disease for the first time by examining a large cohort of patients with morphologically confirmed endolymphatic hydrops using a detailed physician-administered neurotologic face-to-face interview. RESULTS: During a hydropic vertigo attack, the patients report nausea, vomiting, sweating, urge to defecate, urge to urinate, phosphenes, headache, photophobia, phonophobia and even transient loss of consciousness. A third of the patients does not experience auditory symptoms during the vertigo attacks. Vertigo attacks last less than 20 min in more than one-fourth of the patients. Audiometric hearing loss has its greatest diagnostic value at the frequencies of 1 kHz and below. Cochleovestibular symptom onset simultaneity is associated with a high frequency of drop-attacks. Migraine and autoimmune disorders are not associated with hydropic ear disease. CONCLUSION: This study marks the beginning of the clinical characterization of hydropic ear disease. The findings have important implications for the future formulation of clinical diagnostic criteria.


Asunto(s)
Audiometría/métodos , Oído Interno/patología , Hidropesía Endolinfática/diagnóstico , Imagen por Resonancia Magnética/métodos , Hidropesía Endolinfática/complicaciones , Hidropesía Endolinfática/fisiopatología , Femenino , Estudios de Seguimiento , Pérdida Auditiva/etiología , Pérdida Auditiva/fisiopatología , Humanos , Hiperacusia , Masculino , Persona de Mediana Edad
12.
J Vis Exp ; (132)2018 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-29553505

RESUMEN

Analysis of neural structures in Menière's Disease (MD) is of importance, since a loss of such structures has previously been proposed for this patient group but has yet to be confirmed. This protocol describes a method of in vivo evaluation of neural changes especially well suitable for cranial nerve analysis using magnetic resonance imaging (MRI). MD-patients and normal hearing persons were examined in a 3-T MR-scanner using a scan protocol including strongly T2-weighted 3D gradient-echo-sequence (3D-CISS). In the patient group, MD was additionally confirmed using MRI-based assessment of endolymphatic hydrops. Morphometric analysis was performed using a freeware DICOM viewer. Evaluation of cranial nerves included measurements of cross-sectional areas (CSAs) of the nerves at different levels as well as orthogonal diametric measurements.


Asunto(s)
Nervios Craneales/diagnóstico por imagen , Oído/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Oído/patología , Humanos
13.
Radiol Med ; 122(11): 822-828, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28733918

RESUMEN

PURPOSE: To establish an optimized ultralow-dose digital pulsed fluoroscopy (FP) protocol for upper gastrointestinal tract examinations and to investigate the radiation dose and image quality. MATERIALS AND METHODS: An Alderson-Rando-Phantom with 60 thermoluminescent dosimeters was used for dose measurements to systematically evaluate the dose-area product (DAP) and organ doses of the optimized FP protocol with the following acquisition parameters: 86.7 kV; 77 mA; 0.9 mm3, automatic image noise and contrast adaption. Subjective image quality, depiction of contrast agent and image noise (5-point Likert scale; 5 = excellent) were assessed in 41 patients, who underwent contrast-enhanced FP with the aforementioned optimized protocol by two radiologists in consensus. A conventional digital radiograph (DR) acquisition protocol served as the reference standard for radiation dose and image quality analyses. RESULTS: Phantom measurements revealed a general dose reduction of approximately 96% per image for the FP protocol as compared to the DR standard. DAP could be reduced by 97%. Significant dose reductions were also found for organ doses, both in the direct and scattered radiation beam with negligible orbital (FP 5.6 × 10-3 vs. DR 0.11; p = 0.02) and gonadal dose exposure (female FP 2.4 × 10-3 vs. DR 0.05; male FP 8 × 10-4 vs. DR 0.03; p ≤ 0.0004). FP provided diagnostic image quality in all patients, although reading scores were significantly lower for all evaluated parameters as compared to the DR standard (p < 0.05). CONCLUSION: Ultralow-dose FP is feasible for clinical routine allowing a significant reduction of direct and scattered dose exposure while providing sufficient diagnostic image quality for reliable diagnosis.


Asunto(s)
Fluoroscopía/métodos , Tracto Gastrointestinal Superior/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Dosis de Radiación , Estudios Retrospectivos , Dosimetría Termoluminiscente
14.
Eur Arch Otorhinolaryngol ; 274(8): 3029-3039, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28584970

RESUMEN

Loss of neural structures (such as hair cells or neurones within the spiral ganglion) has been proposed to be involved in Menière's disease (MD) (Spoendlin et al. Acta oto-laryngologica Supplementum 499:1-21, 1; Merchant et al. Eur Arch Oto-Rhino-Laryngol Off J Eur Feder Oto-Rhino-Laryngol Soc (EUFOS) Affil German Soc Oto-Rhino-Laryngol Head Neck Surg 252(2):63-75, 2; Tsuji et al. Ann Otol Rhinol Laryngol Suppl 81:26-31, 3; Kariya, Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 28(8):1063-1068, 4; Megerian Laryngoscope 115(9):1525-1535, 5) but this has yet to be confirmed. Therefore, the aim of this study was to investigate morphometric changes of VIIth and VIIIth cranial nerve in MD. MD is characterized by episodic vertigo, tinnitus, fluctuating hearing loss, and aural fullness. The exact pathophysiological mechanisms involved such as viral infections, autoimmune processes, genetic predisposition, cellular apoptosis, and oxidative stress are still not clear. Using a T2-weighted 3D-GE "constructive interference in steady state" (CISS) 3T magnetic resonance imaging (MRI) sequence, we evaluated the properties of the VIIth and VIIIth cranial nerves as they passed from the cerebellopontine angle to the inner ear modiolus. 21 patients with MD were examined along with 39 normal controls. Bidirectional nerve diameters and cross-sectional areas (CSA) were measured in a transverse plane. The comparison of study and control group showed statistically significant (P < 0.000595 after Bonferroni correction) differences between the CSA measurements. The facial, cochlear, superior vestibular, and inferior vestibular nerves (FN, CN, SVN, IVN) of MD patients were significantly larger than those of the control group, both on the MD-affected side and on the healthy side. Thus for example, the cochlear nerve CSA measurements were 0.69 ± 0.14 mm2 (P < 0.0001) in the affected ears of the unilateral MD group, 0.70 ± 0.12 mm2 (P < 0.0001) in the affected ears of the cohort including the bilateral MD group, 0.71 ± 0.13 mm2 (P < 0.0001) in the non-affected ears of the MD patients, as compared to 0.46 ± 0.14 mm2 in the control group. The perpendicular nerve diameters were found to vary according to site of measurement and type of measurement used. For example a statistically significant enlargement of the short diameter measurements of the SVN at the level of the meatus was found, but not of long diameter measurements at the same site. Although cellular death would theoretically be expected to lead to a decreased nerve thickness, our data showed a swelling of cranial nerves VII and VIII within the study group compared to our normal hearing control group. The similar reaction of the facial nerve supports mediator-based theories of MD pathophysiology.


Asunto(s)
Oído Interno/inervación , Nervio Facial/diagnóstico por imagen , Enfermedad de Meniere , Nervio Vestibulococlear/diagnóstico por imagen , Adulto , Anciano , Femenino , Alemania , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Enfermedad de Meniere/diagnóstico , Enfermedad de Meniere/fisiopatología , Persona de Mediana Edad
15.
Acta Radiol ; 58(9): 1037-1044, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28084814

RESUMEN

Background Fluoroscopy is a frequently used examination in clinical routine without appropriate research evaluation latest hardware and software equipment. Purpose To evaluate the feasibility of low-dose pulsed video-fluoroscopic swallowing exams (pVFSE) to reduce dose exposure in patients with swallowing disorders compared to high-resolution radiograph examinations (hrVFSE) serving as standard of reference. Material and Methods A phantom study (Alderson-Rando Phantom, 60 thermoluminescent dosimeters [TLD]) was performed for dose measurements. Acquisition parameters were as follows: (i) pVFSE: 76.7 kV, 57 mA, 0.9 Cu mm, pulse rate/s 30; (ii) hrVFSE: 68.0 kV, 362 mA, 0.2 Cu mm, pictures 30/s. The dose area product (DAP) indicated by the detector system and the radiation dose derived from the TLD measurements were analyzed. In a patient study, image quality was assessed qualitatively (5-point Likert scale, 5 = hrVFSE; two independent readers) and quantitatively (SNR) in 35 patients who subsequently underwent contrast-enhanced pVFSE and hrVFSE. Results Phantom measurements showed a dose reduction per picture of factor 25 for pVFSE versus hrVFSE images (0.0025 mGy versus 0.062 mGy). The DAP (µGym2) was 28.0 versus 810.5 (pVFSE versus hrVFSE) for an average examination time of 30 s. Direct and scattered organ doses were significantly lower for pVFSE as compared to hrVFSE ( P < 0.05). Image quality was rated 3.9 ± 0.5 for pVFSE versus the hrVFSE standard; depiction of the contrast agent 4.8 ± 0.3; noise 3.6 ± 0.5 ( P < 0.05); SNR calculations revealed a relative decreased of 43.9% for pVFSE as compared to hrVFSE. Conclusion Pulsed VFSE is feasible, providing diagnostic image quality at a significant dose reduction as compared to hrVFSE.


Asunto(s)
Trastornos de Deglución/diagnóstico por imagen , Dosis de Radiación , Grabación en Video , Medios de Contraste , Trastornos de Deglución/fisiopatología , Estudios de Factibilidad , Fluoroscopía/métodos , Humanos , Fantasmas de Imagen , Dosimetría Termoluminiscente
16.
J Neurosurg ; 124(5): 1319-27, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26566206

RESUMEN

OBJECT Treatment of skull base lesions is complex and usually requires a multidisciplinary approach. In meningioma, which is the most common tumor entity in this region, resection is considered to be the most important therapeutic step to avoid tumor recurrence. However, resection of skull base lesions with orbital or optic nerve involvement poses a challenge due to their anatomical structure and their proximity to eloquent areas. Therefore the main goal of surgery should be to achieve the maximum extent of resection while preserving neurological function. In the postoperative course, medical and radiotherapeutic strategies may then be successfully used to treat possible tumor residues. Methods to safely improve the extent of resection in skull base lesions therefore are desirable. The current study reports the authors' experience with the use of intraoperative CT (iCT) combined with neuronavigation with regard to feasibility and possible benefits of the method. METHODS Those patients with tumorous lesions in relationship to the orbit, sphenoid wing, or cavernous sinus who were surgically treated between October 2008 and December 2013 using iCT-based neuronavigation and in whom an intraoperative scan was obtained for control of resection were included. In all cases a second iCT scan was performed under sterile conditions after completion of navigation-guided microsurgical tumor resection. The surgical strategy was adapted accordingly; if necessary, resection was continued. RESULTS Twenty-three patients (19 with WHO Grade I meningioma and 4 with other lesions) were included. The most common clinical symptoms were loss of visual acuity and exophthalmus. Intraoperative control of resection by iCT was successfully obtained in all cases. Intraoperative imaging changed the surgical approach in more than half (52.2%) of these patients, either because iCT demonstrated unexpected residual tumor masses or because the second scan revealed additional tumor tissue that was not detected in the first scan due to overlay by osseous tumor parts; in these cases resection was continued. In the remaining cases resection was concluded as planned because iCT verified the surgeon's microscopic estimation of tumor resection status. Postoperative visual outcome was favorable in more than 80% of patients. CONCLUSIONS Intraoperative CT allows control of resection in case of uncertainty and can help to improve the extent of maximal safe resection, especially in case of osseous tumor parts and masses within the orbit.


Asunto(s)
Neoplasias Meníngeas/patología , Neoplasias Meníngeas/cirugía , Meningioma/patología , Meningioma/cirugía , Microcirugia/métodos , Neoplasia Residual/patología , Neoplasia Residual/cirugía , Neuronavegación/métodos , Neoplasias Orbitales/patología , Neoplasias Orbitales/cirugía , Neoplasias de la Base del Cráneo/patología , Neoplasias de la Base del Cráneo/cirugía , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Reoperación , Sensibilidad y Especificidad
17.
Psychiatry Res ; 221(3): 187-94, 2014 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-24434193

RESUMEN

Primary progressive aphasia (PPA) is characterized by left hemispheric frontotemporal cortical atrophy. Evidence from anatomical studies suggests that the nucleus subputaminalis (NSP), a subnucleus of the cholinergic basal forebrain, may be involved in the pathological process of PPA. Therefore, we studied the pattern of cortical and basal forebrain atrophy in 10 patients with a clinical diagnosis of PPA and 18 healthy age-matched controls using high-resolution magnetic resonance imaging (MRI). We determined the cholinergic basal forebrain nuclei according to Mesulam's nomenclature and the NSP in MRI reference space based on histological sections and the MRI scan of a post-mortem brain in cranio. Using voxel-based analysis, we found left hemispheric cortical atrophy in PPA patients compared with controls, including prefrontal, lateral temporal and medial temporal lobe areas. We detected cholinergic basal forebrain atrophy in left predominant localizations of Ch4p, Ch4am, Ch4al, Ch3 and NSP. For the first time, we have described the pattern of basal forebrain atrophy in PPA and confirmed the involvement of NSP that had been predicted based on theoretical considerations. Our findings may enhance understanding of the role of cholinergic degeneration for the regional specificity of the cortical destruction leading to the syndrome of PPA.


Asunto(s)
Afasia Progresiva Primaria/patología , Corteza Cerebral/patología , Fibras Colinérgicas/patología , Prosencéfalo/patología , Anciano , Atrofia , Encéfalo/patología , Función Ejecutiva , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Corteza Prefrontal/patología , Lóbulo Temporal/patología
18.
Otol Neurotol ; 33(8): 1375-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22918115

RESUMEN

INTRODUCTION: Canal paresis of the horizontal semicircular canal in Ménière's disease is a frequent finding. Endolymphatic hydrops is the single most characteristic morphologic finding in Ménière's disease. However, the relationship between endolymphatic hydrops and canal paresis is still not elucidated. METHODS: We used magnetic resonance imaging to visualize herniation of parts of the vestibular membranous labyrinth into the horizontal semicircular canal and correlated this morphologic feature with the caloric function of the horizontal semicircular canal. RESULTS: Patients who showed herniation into the horizontal canal had a significantly impaired caloric function when compared with patients without this morphologic feature. CONCLUSION: Herniation into the semicircular canal may be the morphologic correlate for impaired caloric response in patients with Ménière's disease.


Asunto(s)
Pruebas Calóricas , Oído Interno/patología , Hernia/patología , Enfermedad de Meniere/patología , Canales Semicirculares/patología , Adolescente , Adulto , Anciano , Hidropesía Endolinfática/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Enfermedad de Meniere/fisiopatología , Persona de Mediana Edad , Parálisis/etiología , Parálisis/patología , Pruebas de Función Vestibular , Vestíbulo del Laberinto/patología , Adulto Joven
19.
Otol Neurotol ; 33(6): 1040-5, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22772006

RESUMEN

OBJECTIVE: To study the correlation between the degree of endolymphatic hydrops as detected in vivo by magnetic resonance (MR) imaging and the auditory and vestibular function in patients with definite Ménière's disease. STUDY DESIGN: Prospective observational study. SETTING: Tertiary referral center for balance disorders. SUBJECTS AND METHODS: In this prospective study, 41 patients who fulfilled the criteria for definite unilateral Ménière's disease according to the American Association of Otolaryngology-Head and Neck Surgery and who showed a summating potential-to-action potential ratio of greater than 0.4 on electrocochleography were included. Intratympanic contrast-enhanced 3 Tesla MR imaging of the inner ear was performed using a 3D Inversion Recovery Turbo Spin Echo sequence. The degree of endolymphatic hydrops was graded on a Likert scale (0-3) in the cochlea and by vestibular endolymph space ratio in the vestibulum. The degree of hydrops was then analyzed with respect to its correlation with audiometric hearing levels, interaural amplitude ratios of vestibular evoked myogenic potentials, degree of horizontal semicircular canal paresis on caloric irrigation, and disease duration. RESULTS: The degree of hearing loss and the disease duration correlated significantly with cochlear hydrops (r = 0.85; r = 0.34). Sacculus dysfunction was significantly correlated with vestibular hydrops (r = -0.47). There was no significant correlation between horizontal semicircular canal paresis and vestibular hydrops. CONCLUSION: In patients with clinically and electrocochleographically confirmed definite Ménière's disease, the degree of MR morphological hydrops severity correlates significantly with impairment of hearing function and sacculus function.


Asunto(s)
Audiometría de Respuesta Evocada/métodos , Oído Interno/patología , Hidropesía Endolinfática/etiología , Hidropesía Endolinfática/patología , Enfermedad de Meniere/complicaciones , Enfermedad de Meniere/patología , Potenciales de Acción/fisiología , Adulto , Anciano , Medios de Contraste , Interpretación Estadística de Datos , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Canales Semicirculares/fisiopatología , Potenciales Vestibulares Miogénicos Evocados/fisiología , Pruebas de Función Vestibular
20.
Comput Aided Surg ; 17(3): 153-60, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22452534

RESUMEN

INTRODUCTION: For successful cochlear implantation in difficult ears, image guided navigation systems can help identify surgical landmarks or confirm the surgeon's anatomical knowledge. In this pilot case study, exact navigation based on intraoperative CT scanning was investigated and helped confirm important and necessary landmarks, such as the facial nerve, cochlea and intracochlear structures, and at least adequate placement of a straight electrode array. MATERIAL AND METHODS: Intraoperative imaging was performed on a 40-slice sliding-gantry CT scanner (Siemens SOMATOM Sensation 40 Open) with an expanded gantry bore (82 cm). Raw image data were reconstructed with a slice thickness and increment of 0.6 mm and were imported to a frameless infrared-based navigation station (BrainLAB VectorVision Sky). In a preoperative accuracy and feasibility study, a phantom skull was scanned and registered five times by the navigation system. Based on the encouraging results, the system was then applied to a male patient with post-traumatic sensorineural hearing loss. The intraoperative target positioning error was measured by a "blinded" colleague who defined the distance of the pointer from different sections of the facial nerve without seeing the intraoperative field. RESULTS: The average deviation in the phantom skull was 0.91 mm (SD 0.27 mm) on the mastoid, 1.01 mm (SD 0.21 mm) on the round window, and 0.9 mm (SD 0.18 mm) on the inner ear canal. Surgery could be performed without major complications. The distance of the pointer from the facial nerve could be defined exactly using navigation in ten measurements. The cochleostomy and electrode insertion were performed with the aid of navigation. After insertion, direct intraoperative control of the electrode position was achieved by means of a low-dose CT scan. Two months postoperatively, the patient had a satisfactory open-set speech understanding of 85%. CONCLUSION: With the use of intraoperative acquisition of CT images (or digital volume tomography devices) and automatic volumetric registration for navigation, surgical precision can be improved, thereby allowing successful cochlear implant surgery in patients with complex malformations or who have undergone multiple previous ear surgeries and consequently lack anatomical landmarks. Our study clearly shows that this high-technology combination is superior to other registration methods in terms of accuracy and precision. Further investigations should aim at developing automatic segmentation and applications for minimally invasive surgery of the lateral skull base.


Asunto(s)
Implantación Coclear/instrumentación , Pérdida Auditiva/cirugía , Periodo Intraoperatorio , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Adulto , Implantación Coclear/métodos , Nervio Facial/cirugía , Estudios de Factibilidad , Femenino , Pérdida Auditiva/etiología , Humanos , Masculino , Proyectos Piloto , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Heridas y Lesiones/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...