Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Environ Sci Pollut Res Int ; 30(51): 111369-111381, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37814047

RESUMEN

More stringent discharge standards have led to the development of an alternative nutrient recovery system from wastewater. Microalgae cultivation in wastewater treatment works has presented considerable promise from the perspective of sustainable resource management. Growth kinetics models are useful tools to optimize nutrient recovery from wastewater by algal uptake. Therefore, this research aims to identify the growth kinetics of Chlamydomonas reinhardtii under both heterotrophic and phototrophic conditions with different nutrient concentrations that typify those found in wastewater treatment works. In addition, the effects of macronutrients (C, N, and P) on heterotrophic and phototrophic microalgae growth and nutrient recovery were studied. Greater specific growth rates were achieved under heterotrophic conditions than in phototrophic cultivation. The maximum specific growth rates and nutrient recovery efficiencies were achieved at 5 mg P L-1 under both heterotrophic and phototrophic growth conditions. Nitrate was the preferred form of nitrogen source under heterotrophic conditions, while nitrogen sources did not present any significant influences in the phototrophic cultivation. Specific growth rates reported for both heterotrophic and phototrophic microalgae at lower carbon concentrations (3.10 d-1 and 0.46 d-1, sequentially) were higher than those at higher carbon concentrations (1.95 d-1 and 0.22 d-1, respectively). C. reinhardtii presented an extreme capacity to adapt and grow at all experimental conditions tested in heterotrophic and phototrophic cultivations.


Asunto(s)
Chlamydomonas reinhardtii , Microalgas , Aguas Residuales , Nitrógeno/farmacología , Fósforo/farmacología , Carbono/farmacología , Nutrientes , Biomasa
2.
Indoor Air ; 32(11): e13161, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437677

RESUMEN

Hospital-acquired infections (HAIs) are a global challenge incurring mortalities and high treatment costs. The environment plays an important role in transmission due to contaminated air and surfaces. This includes microorganisms' deposition from the air onto surfaces. Quantifying the deposition rate of microorganisms enables understanding surface contamination and can inform strategies to mitigate the infection risk. We developed and validated a novel Automated Multiplate Passive Air Sampling (AMPAS) device. This enables sequences of passive deposition samples to be collected over a controlled time period without human intervention. AMPAS was used with air sampling to measure the effect of ventilation rate and spatial location on the deposition rate of aerosolized Staphylococcus aureus in a 32 m3 chamber. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of microbial load in the air and on surfaces by 45% ± 10% and 44% ± 32%, respectively. The deposition rate onto internal surfaces λd was calculated as 1.38 ± 0.48 h-1 . Samples of airborne and surface microorganisms taken closer to the ventilation supply showed a lower concentration than close to the extract. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment.


Asunto(s)
Contaminación del Aire Interior , Infección Hospitalaria , Humanos , Contaminación del Aire Interior/análisis , Ventilación , Staphylococcus aureus , Hospitales
3.
Sci Rep ; 12(1): 4373, 2022 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-35322064

RESUMEN

Many infectious diseases, including COVID-19, are transmitted by airborne pathogens. There is a need for effective environmental control measures which, ideally, are not reliant on human behaviour. One potential solution is Krypton Chloride (KrCl) excimer lamps (often referred to as Far-UVC), which can efficiently inactivate pathogens, such as coronaviruses and influenza, in air. Research demonstrates that when KrCl lamps are filtered to remove longer-wavelength ultraviolet emissions they do not induce acute reactions in the skin or eyes, nor delayed effects such as skin cancer. While there is laboratory evidence for Far-UVC efficacy, there is limited evidence in full-sized rooms. For the first time, we show that Far-UVC deployed in a room-sized chamber effectively inactivates aerosolised Staphylococcus aureus. At a room ventilation rate of 3 air-changes-per-hour (ACH), with 5 filtered-sources the steady-state pathogen load was reduced by 98.4% providing an additional 184 equivalent air changes (eACH). This reduction was achieved using Far-UVC irradiances consistent with current American Conference of Governmental Industrial Hygienists threshold limit values for skin for a continuous 8-h exposure. Our data indicate that Far-UVC is likely to be more effective against common airborne viruses, including SARS-CoV-2, than bacteria and should thus be an effective and "hands-off" technology to reduce airborne disease transmission. The findings provide room-scale data to support the design and development of effective Far-UVC systems.


Asunto(s)
COVID-19 , Infecciones Estafilocócicas , Desinfección , Humanos , SARS-CoV-2 , Rayos Ultravioleta
4.
Indoor Air ; 32(1): e12938, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34693567

RESUMEN

Self-contamination during doffing of personal protective equipment (PPE) is a concern for healthcare workers (HCW) following SARS-CoV-2-positive patient care. Staff may subconsciously become contaminated through improper glove removal; so, quantifying this exposure is critical for safe working procedures. HCW surface contact sequences on a respiratory ward were modeled using a discrete-time Markov chain for: IV-drip care, blood pressure monitoring, and doctors' rounds. Accretion of viral RNA on gloves during care was modeled using a stochastic recurrence relation. In the simulation, the HCW then doffed PPE and contaminated themselves in a fraction of cases based on increasing caseload. A parametric study was conducted to analyze the effect of: (1a) increasing patient numbers on the ward, (1b) the proportion of COVID-19 cases, (2) the length of a shift, and (3) the probability of touching contaminated PPE. The driving factors for the exposure were surface contamination and the number of surface contacts. The results simulate generally low viral exposures in most of the scenarios considered including on 100% COVID-19 positive wards, although this is where the highest self-inoculated dose is likely to occur with median 0.0305 viruses (95% CI =0-0.6 viruses). Dose correlates highly with surface contamination showing that this can be a determining factor for the exposure. The infection risk resulting from the exposure is challenging to estimate, as it will be influenced by the factors such as virus variant and vaccination rates.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Fómites , Exposición Profesional , Equipo de Protección Personal , Fómites/virología , Guantes Protectores/virología , Hospitales , Humanos , Equipo de Protección Personal/virología , SARS-CoV-2
5.
Bioresour Technol ; 343: 126086, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34624468

RESUMEN

The anaerobic co-digestion (AcoD) of microalgae is a prospective option for generating biomethane from renewable sources. This study investigates the effects of inoculum-to-substrate ratio (ISR), C/N ratio and biochar (BC) load on the AcoD of Chlorella vulgaris and cellulose. An initial augmentation of BC at ISR 0.5-0.9 and C/N ratio 10-30 offered a pH buffering effect and resulted in biomethane yields of 233-241 mL CH4/g VS, corresponding to 1.8-4.6 times the controls. BC addition ameliorated significantly AcoD, supporting the digestate stability at less favourable conditions. The effect of the process variables was further studied with a 23 factorial design and response optimisation. Under the design conditions, the variables had less influence over methane production. Higher ISRs and C/N ratios favoured AcoD, whereas increasing amounts of BC reduced biomethane yield but enhanced production rate. The factorial design highlighted the importance of BC-load on AcoD, establishing an optimum of 0.58 % (w/v).


Asunto(s)
Chlorella vulgaris , Anaerobiosis , Biocombustibles , Reactores Biológicos , Celulosa , Carbón Orgánico , Digestión , Metano , Estudios Prospectivos
6.
J Eat Disord ; 9(1): 91, 2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34301344

RESUMEN

BACKGROUND: Eating disorders are widely recognized as serious illnesses, with complex psychological and physiological comorbidities. Affected individuals face a protracted and challenging treatment journey which, particularly for children and adolescents, requires significant input from family members as carers. This study investigated the perspectives and experiences of those caring for family members with an eating disorder diagnosis. METHOD: Participants were carers of affected individuals with an eating disorder, and were recruited from an online survey, subsequently consenting to a semi-structured qualitative interview. Inductive thematic analysis was undertaken to identify themes. RESULTS: Most participants in the sample were parents of affected individuals. Significant and ongoing psychological and emotional impacts were identified across the sample. The diagnosis, treatment journey and overall impact of the carer role created a situation captured by the over-arching theme 'life is different now'. Impacts profoundly influenced relationships and were felt across all aspects of life by carers, affected individuals and other family members. Heightened worry and vigilance experienced by carers continued beyond improvement or recovery. CONCLUSIONS: This research highlighted challenging and often exhausting impacts felt by carers due to their pivotal role in eating disorder treatment. Inadequate support for most carers in this sample has clear implications for families as well as service and funding providers. Further research should more fully investigate carer experience with different eating disorders to explore the type of support necessary to build capacity and resilience to reduce carer burden.


Eating disorders (EDs) are serious illnesses with a challenging treatment journey that often requires significant input from family members as carers. This study investigated perspectives and experiences of those caring for family members with an ED diagnosis.Carers reported significant impacts on many facets of their lives. The findings revealed levels of emotional and psychological stress both during and beyond the treatment journey. For carers 'normal' life was profoundly impacted by the complicated and often unanticipated role of treatment provider, and navigating the maze of treatment while trying to understand the diagnosis itself. For those with other children, the impacts were compounded by the distress also witnessed in those children. Relationships were significantly affected by the demands of treatment and the serious consequences of the disorder, as well as misunderstandings and stigma related to EDs.A 'new normal' state of constant worry and ongoing vigilance defined life post-diagnosis. The results indicate the impacts of an ED diagnosis in a loved one, and the demands of caring for that person and assuming the role of treatment provider were life-changing. For these carers, 'life is different now'.

7.
Indoor Air ; 31(5): 1308-1322, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33945176

RESUMEN

Airborne microorganisms in hospitals have been associated with several hospital-acquired infections (HAIs), and various measures of indoor air quality (IAQ) parameters such as temperature, relative humidity, carbon dioxide (CO2 ), particle mass concentration, and particle size have been linked to pathogen survival or mitigation of pathogen spread. To investigate whether there are quantitative relationships between the concentration of airborne microorganisms and the IAQ in the hospital environment. Web of Science, Scopus and PubMed databases were searched for studies reporting airborne microbial levels and any IAQ parameter(s) in hospital environments, from database inception to October 2020. Pooled effect estimates were determined via random-effects models. Seventeen of 654 studies were eligible for the meta-analysis. The concentration of airborne microbial measured as aerobic colony count (ACC) was significantly correlated with temperature (r = 0.25 [95% CI = 0.06-0.42], p = 0.01), CO2 concentration (r = 0.53 [95% CI = 0.40-0.64], p Ë‚ 0.001), particle mass concentration (≤5 µg/m3 ; r = 0.40 [95% CI = 0.04-0.66], p = 0.03), and particle size (≤5 and ˃5 µm), (r = 0.51 [95% CI = 0.12-0.77], p = 0.01 and r = 0.55 [95% CI = 0.20-0.78], p = 0.003), respectively, while not being significantly correlated with relative humidity or particulate matter of size >5 µm. Conversely, airborne total fungi (TF) were not significantly correlated with temperature, relative humidity, or CO2 level. However, there was a significant weak correlation between ACC and TF (r = 0.31 [95% CI = 0.07-0.52], p = 0.013). Although significant correlations exist between ACC and IAQ parameters, the relationship is not definitive; the IAQ parameters may affect the microorganisms but are not responsible for the presence of airborne microorganisms. Environmental parameters could be related to the generating source, survival, dispersion, and deposition rate of microorganisms. Future studies should record IAQ parameters and factors such as healthcare worker presence and the activities carried out such as cleaning, sanitizing, and disinfection protocols. Foot traffic would influence both the generation of microorganisms and their deposition rate onto surfaces in the hospital environment. These data would inform models to improve the understanding of the likely concentration of airborne microorganisms and provide an alternative approach for real-time monitoring of the healthcare environment.


Asunto(s)
Microbiología del Aire , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Hospitales , Material Particulado , Dióxido de Carbono , Monitoreo del Ambiente , Hongos , Humanos , Temperatura
8.
Bioresour Technol ; 321: 124494, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33302012

RESUMEN

The augmentation of biochar produced at 450 and 600-650 °C and hydrochar produced at 250 °C has been investigated using biochemical methane potential experiments of cellulose. The feedstocks used for the char production included the lignocellulosic (oak wood), macroalgae (Fucus serratus) and aquatic plant (water hyacinth). Biomethane production was improved with the addition of lower-temperature biochars from oak wood (285 mL CH4/g VS) and water hyacinth (294 mL CH4/g VS), corresponding to 7 and 11% more than the control. The addition of these two biochars increased the methane production rate of 2.4 and 2.3 times the control, respectively. Higher temperature biochars showed no difference. Conversely, all hydrochars and macroalgae biochars augmentation reduced methane generation by 57-86 %. The chemical and structural composition of each of the chars differed significantly. Surface oxygen functionality appears to be the most important property of the biochars that improved digestion performance.


Asunto(s)
Carbón Orgánico , Metano , Anaerobiosis , Madera
9.
Indoor Air ; 30(5): 993-1004, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32329918

RESUMEN

Bacterial transmission from contaminated surfaces via hand contact plays a critical role in disease spread. However, the fomite-to-finger transfer efficiency of microorganisms during multiple sequential surface contacts with and without gloves has not been formerly investigated. We measured the quantity of Escherichia coli on fingertips of participants after 1-8 sequential contacts with inoculated plastic coupons with and without nitrile gloves. A Bayesian approach was used to develop a mechanistic model of pathogen accretion to examine finger loading as a function of the difference between E coli on surfaces and fingers. We used the model to determine the coefficient of transfer efficiency (λ), and influence of swabbing efficiency and finger area. Results showed that λ for bare skin was higher (49%, 95% CI = 32%-72%) than for gloved hands (30%, CI = 17%-49%). Microbial load tended toward a dynamic equilibrium after four and six contacts for gloved hands and bare skin, respectively. Individual differences between volunteers' hands had a negligible effect compared with use of gloves (P < .01). Gloves reduced loading by 4.7% (CI = -12%-21%) over bare skin contacts, while 20% of participants accrued more microorganisms on gloved hands. This was due to poor fitting, which created a larger finger surface area than bare hands.


Asunto(s)
Bacterias , Fómites/microbiología , Guantes Protectores/microbiología , Mano/microbiología , Desinfección de las Manos , Humanos
10.
PLoS One ; 12(3): e0171735, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28323885

RESUMEN

MOTIVATION: Proper management of fecal sludge has significant positive health and environmental externalities. Most research on managing onsite sanitation so far either simulates the costs of, or the welfare effects from, managing sludge in situ in pit latrines. Thus, designing management strategies for onsite rural sanitation is challenging, because the actual costs of transporting sludge for treatment, and sources for financing these transport costs, are not well understood. METHODS: In this paper we calculate the actual cost of sludge management from onsite latrines, and identify the contributions that latrine owners are willing to make to finance the costs. A spreadsheet-based model is used to identify a cost-effective transport option, and to calculate the cost per household. Then a double-bound contingent valuation method is used to elicit from pit-latrine owners their willingness-to-pay to have sludge transported away. This methodology is employed for the case of a rural subdistrict in Bangladesh called Bhaluka, a unit of administration at which sludge management services are being piloted by the Government of Bangladesh. RESULTS: The typical sludge accumulation rate in Bhaluka is calculated at 0.11 liters/person/day and a typical latrine will need to be emptied approximately once every 3 to 4 years. The costs of emptying and transport are high; approximately USD 13 per emptying event (circa 14% of average monthly income); household contributions could cover around 47% of this cost. However, if costs were spread over time, the service would cost USD 4 per year per household, or USD 0.31 per month per household-comparable to current expenditures of rural households on telecommunications. CONCLUSION: This is one of few research papers that brings the costs of waste management together with financing of that cost, to provide evidence for an implementable solution. This framework can be used to identify cost effective sludge management options and private contributions towards that cost in other (context-specific) administrative areas where onsite sanitation is widespread.


Asunto(s)
Aguas del Alcantarillado , Cuartos de Baño/economía , Administración de Residuos/economía , Bangladesh , Análisis Costo-Beneficio , Humanos , Modelos Económicos , Población Rural , Transportes/economía
13.
BMC Microbiol ; 8: 105, 2008 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-18582388

RESUMEN

BACKGROUND: Cystic fibrosis (CF) is an inherited multi-system disorder characterised by chronic airway infection with pathogens such as Pseudomonas aeruginosa. Acquisition of P. aeruginosa by patients with CF is usually from the environment, but recent studies have demonstrated patient to patient transmission of certain epidemic strains, possibly via an airborne route. This study was designed to examine the survival of P. aeruginosa within artificially generated aerosols. RESULTS: Survival was effected by the solution used for aerosol generation. Within the aerosols it was adversely affected by an increase in air temperature. Both epidemic and non-epidemic strains of P. aeruginosa were able to survive within the aerosols, but strains expressing a mucoid phenotype had a survival advantage. CONCLUSION: This would suggest that segregating individuals free of P. aeruginosa from those with chronic P. aeruginosa infection who are more likely to be infected with mucoid strains may help reduce the risk of cross-infection. Environmental factors also appear to influence bacterial survival. Warming and drying the air within clinical areas and avoidance of humidification devices may also be beneficial in reducing the risk of cross-infection.


Asunto(s)
Aerosoles/química , Microbiología del Aire , Fibrosis Quística/microbiología , Viabilidad Microbiana , Infecciones por Pseudomonas/transmisión , Pseudomonas aeruginosa/crecimiento & desarrollo , Aerosoles/efectos adversos , Humanos , Soluciones Isotónicas/farmacología , Tamaño de la Partícula , Infecciones por Pseudomonas/epidemiología , Infecciones por Pseudomonas/microbiología , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/aislamiento & purificación , Solución de Ringer , Agua/farmacología
14.
BMC Microbiol ; 7: 32, 2007 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-17439657

RESUMEN

BACKGROUND: In recent years there has been renewed interest in the use of air ionisers to control of the spread of airborne infection. One characteristic of air ions which has been widely reported is their apparent biocidal action. However, whilst the body of evidence suggests a biocidal effect in the presence of air ions the physical and biological mechanisms involved remain unclear. In particular, it is not clear which of several possible mechanisms of electrical origin (i.e. the action of the ions, the production of ozone, or the action of the electric field) are responsible for cell death. A study was therefore undertaken to clarify this issue and to determine the physical mechanisms associated with microbial cell death. RESULTS: In the study seven bacterial species (Staphylococcus aureus, Mycobacterium parafortuitum, Pseudomonas aeruginosa, Acinetobacter baumanii, Burkholderia cenocepacia, Bacillus subtilis and Serratia marcescens) were exposed to both positive and negative ions in the presence of air. In order to distinguish between effects arising from: (i) the action of the air ions; (ii) the action of the electric field, and (iii) the action of ozone, two interventions were made. The first intervention involved placing a thin mica sheet between the ionisation source and the bacteria, directly over the agar plates. This intervention, while leaving the electric field unaltered, prevented the air ions from reaching the microbial samples. In addition, the mica plate prevented ozone produced from reaching the bacteria. The second intervention involved placing an earthed wire mesh directly above the agar plates. This prevented both the electric field and the air ions from impacting on the bacteria, while allowing any ozone present to reach the agar plate. With the exception of Mycobacterium parafortuitum, the principal cause of cell death amongst the bacteria studied was exposure to ozone, with electroporation playing a secondary role. However in the case of Mycobacterium parafortuitum, electroporation resulting from exposure to the electric field appears to have been the principal cause of cell inactivation. CONCLUSION: The results of the study suggest that the bactericidal action attributed to negative air ions by previous researchers may have been overestimated.


Asunto(s)
Ionización del Aire , Aniones/farmacología , Antibacterianos/farmacología , Bacterias/efectos de los fármacos , Cationes/farmacología , Electroquímica , Pruebas de Sensibilidad Microbiana , Nitrógeno/farmacología , Electricidad Estática
15.
Redox Rep ; 10(1): 2-8, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15829105

RESUMEN

Organ transplant recipients develop pronounced cardiovascular disease, and decreased antioxidant capacity in plasma and erythrocytes is associated with the pathogenesis of this disease. These experiments tested the hypothesis that the immunosuppressant cyclosporine A (CsA) alters erythrocyte redox balance and reduces plasma antioxidant capacity. Female Sprague-Dawley rats were randomly assigned to a control or CsA treated group. Treatment animals received 25 mg/kg/day of CsA via intraperitoneal injection for 18 days. Control rats were injected with the same volume of the vehicle. Three hours after the final CsA injection, rats were exsanguinated and plasma analysed for total antioxidant status (TAS), alpha-tocopherol, malondialdehyde (MDA), and creatinine. Erythrocytes were analysed for superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPX) and glucose-6-phosphate dehydrogenase (G6PD) activities, alpha-tocopherol, and MDA. CsA administration resulted in a significant (P < 0.05) decrease in plasma TAS and significant increases (P < 0.05) in plasma creatinine and MDA. Erythrocyte CAT was significantly (P < 0.05) increased in CsA treated rats compared to controls. There were no significant differences (P > 0.05) in erythrocyte SOD, GPX, G6PD, alpha-tocopherol or MDA between groups. In summary, CsA alters erythrocyte antioxidant defence and decreases plasma total antioxidant capacity.


Asunto(s)
Antioxidantes/metabolismo , Ciclosporina/farmacología , Eritrocitos/metabolismo , Animales , Peso Corporal/efectos de los fármacos , Creatinina/sangre , Eritrocitos/efectos de los fármacos , Femenino , Malondialdehído/sangre , Ratas , Ratas Sprague-Dawley , Especies Reactivas de Oxígeno/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...