Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-37982158

RESUMEN

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Hemorragia/etiología , Hemorragia/prevención & control , Técnicas Hemostáticas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
2.
J Invasive Cardiol ; 35(5): E234-E247, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37219850

RESUMEN

OBJECTIVES: This study aimed to assess discordance between results of instantaneous wave-free ratio (iFR), fractional flow reserve (FFR), and intravascular ultrasound (IVUS) in intermediate left main coronary (LM) lesions, and its impact on clinical decision making and outcome. METHODS: We enrolled 250 patients with a 40%-80% LM stenosis in a prospective, multicenter registry. These patients underwent both iFR and FFR measurements. Of these, 86 underwent IVUS and assessment of the minimal lumen area (MLA), with a 6 mm2 cutoff for significance. RESULTS: Isolated LM disease was recognized in 95 patients (38.0%), while 155 patients (62.0%) had both LM disease and downstream disease. In 53.2% of iFR+ and 56.7% of FFR+ LM lesions, the measurement was positive in only one daughter vessel. iFR/FFR discordance occurred in 25.0% of patients with isolated LM disease and 36.2% of patients with concomitant downstream disease (P=.049). In patients with isolated LM disease, discordance was significantly more common in the left anterior descending artery and younger age was an independent predictor of iFR-/FFR+ discordance. iFR/MLA and FFR/MLA discordance occurred in 37.0% and 29.4%, respectively. Within 1 year of follow-up, major cardiac adverse events (MACE) occurred in 8.5% and 9.7% (P=.763) of patients whose LM lesion was deferred or revascularized, respectively. Discordance was not an independent predictor of MACE. CONCLUSIONS: Current methods of estimating LM lesion significance often yield discrepant findings, complicating therapeutic decision-making.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Humanos , Estudios Prospectivos , Toma de Decisiones Clínicas , Constricción Patológica , Sistema de Registros
3.
Acta Cardiol ; 77(10): 922-929, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36044035

RESUMEN

BACKGROUND: Stroke is a major concern in transcatheter aortic valve replacement (TAVR). The introduction of a cerebral protection devices may counteract the evolution towards minimally invasive TAVR. At this time, there is insufficient data to support the routine use of these devices. METHODS: We aimed to evaluate the outcome of the routine use of the Sentinel Cerebral protection system® (CPS) in patients undergoing TAVR, after completing a CT-based screening process for feasibility of Sentinel implantation. We report our initial experience with the routine implementation of the Sentinel CPS in all anatomically suitable patients undergoing TAVR. We retrospectively compared the procedural characteristics and outcomes between all TAVR patients treated with (n = 78) and without (n = 79) intended Sentinel. RESULTS: The Sentinel CPS could successfully be deployed in 99% of intended cases after CT feasibility screening. TAVR procedures with Sentinel CPS were not longer than procedures without Sentinel use (89 ± 20 versus 120 ± 50 min, p = 0.007). Sentinel CPS use was not associated with an increased risk of procedural complications. Stroke was observed in none (0%) of the Sentinel CPS patients, and in 6.3% of the non-Sentinel CPS patients (p = 0.05). The finding of stroke was associated with a high risk of early postprocedural mortality: 60% of stroke patients died within 3 months. CONCLUSION: Routine use of the Sentinel CPS in CT-screened TAVR patients is feasible with high procedural success, without significant adverse events and without counteracting the evolution towards minimally invasive TAVR. Clinically relevant stroke was observed in none of the Sentinel CPS patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Tiempo , Embolia Intracraneal/diagnóstico , Embolia Intracraneal/etiología , Embolia Intracraneal/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo
4.
Acta Cardiol ; 77(4): 328-332, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34176430

RESUMEN

Combining myocardial perfusion single photon emission computed tomography (SPECT-MPI) and coronary computed tomography angiography (CCTA) is an interesting hybrid imaging option in modern cardiovascular medicine. The integrated hybrid technique has a number of advantages compared to visual side-by-side analysis of the separate modalities. CT attenuation map can correct for attenuation artefacts and thus improve the diagnostic accuracy of SPECT-MPI. Moreover, the anatomical information of the CCTA and the perfusion map of SPECT-MPI allow for vessel-based correlation and culprit vessel identification. Combining SPECT-MPI with CCTA is an appealing tool in the work-up of complex ischaemic heart disease and might help determine the optimal treatment strategy. This case series illustrates the role of SPECT-CCTA in decision-making of revascularization strategy in complex ischaemic heart disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Humanos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X
5.
Acta Cardiol ; 76(8): 863-869, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32727305

RESUMEN

AIMS: The current study assessed the impact of COVID-19-related public containment measures (i.e. lockdown) on the ST elevation myocardial infarction (STEMI) epidemic in Belgium. METHODS AND RESULTS: Clinical characteristics, reperfusion therapy modalities, COVID-19 status and in-hospital mortality of consecutive STEMI patients who were admitted to Belgian hospitals for percutaneous coronary intervention (PCI) were recorded during a three-week period starting at the beginning of the lockdown period on 13 March 2020. Similar data were collected for the same time period for 2017-2019. An evaluation of air quality revealed a 32% decrease in ambient NO2 concentrations during lockdown (19.5 µg/m³ versus 13.2 µg/m³, p < .001). During the three-week period, there were 188 STEMI patients admitted for PCI during the lockdown versus an average 254 STEMI patients before the lockdown period (incidence rate ratio = 0.74, p = .001). Reperfusion strategy was predominantly primary PCI in both time periods (96% versus 95%). However, there was a significant delay in treatment during the lockdown period, with more late presentations (>12 h after onset of pain) (14% versus 7.6%, p = .04) and with longer door-to-balloon times (median of 45 versus 39 min, p = .02). Although the in-hospital mortality between the two periods was comparable (5.9% versus 6.7%), 5 of the 7 (71%) COVID-19-positive STEMI patients died. CONCLUSION: The present study revealed a 26% reduction in STEMI admissions and a delay in treatment of STEMI patients. Less exposure to external STEMI triggers (such as ambient air pollution) and/or reluctance to seek medical care are possible explanations of this observation.


Asunto(s)
COVID-19 , Control de Enfermedades Transmisibles , Epidemias , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Bélgica/epidemiología , COVID-19/prevención & control , Estudios Transversales , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/epidemiología
6.
Ann Noninvasive Electrocardiol ; 25(6): e12794, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32804415

RESUMEN

BACKGROUND: Noninvasive risk stratification aims to detect abnormalities in the pathophysiological mechanisms underlying ventricular arrhythmias. We studied the predictive value of repeating risk stratification in patients with an implantable cardioverter-defibrillator (ICD). METHODS: The EUTrigTreat clinical study was a prospective multicenter trial including ischemic and nonischemic cardiomyopathies and arrhythmogenic heart disease. Left ventricular ejection fraction ≤40% (LVEF), premature ventricular complexes >400/24 hr (PVC), non-negative microvolt T-wave alternans (MTWA), and abnormal heart rate turbulence (HRT) were considered high risk. Tests were repeated within 12 months after inclusion. Adjusted Cox regression analysis was performed for mortality and appropriate ICD shocks. RESULTS: In total, 635 patients had analyzable baseline data with a median follow-up of 4.4 years. Worsening of LVEF was associated with increased mortality (HR 3.59, 95% CI 1.17-11.04), as was consistent abnormal HRT (HR 8.34, 95%CI 1.06-65.54). HRT improvement was associated with improved survival when compared to consistent abnormal HRT (HR 0.10, 95%CI 0.01-0.82). For appropriate ICD shocks, a non-negative MTWA test or high PVC count at any moment was associated with increased arrhythmic risk independent of the evolution of test results (worsening: HR 3.76 (95%CI 1.43-9.88) and HR 2.50 (95%CI 1.15-5.46); improvement: HR 2.80 (95%CI 1.03-7.61) and HR 2.45 (95%CI 1.07-5.62); consistent: HR 2.47 (95%CI 0.95-6.45) and HR 2.40 (95%CI 1.33-4.33), respectively). LVEF improvement was associated with a lower arrhythmic risk (HR 0.34, 95%CI 0.12-0.94). CONCLUSIONS: Repeating LVEF and HRT improved the prediction of mortality, whereas stratification of ventricular arrhythmias may be improved by repeating LVEF measurements, MTWA and ECG Holter monitoring.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía Ambulatoria/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Anciano , Europa (Continente) , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Medición de Riesgo
7.
EuroIntervention ; 14(17): 1776-1783, 2019 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-30375333

RESUMEN

AIMS: We aimed to investigate the effects of an initial learning period with mandatory optical coherence tomography (OCT) guidance for the implantation of everolimus-eluting bioresorbable vascular scaffolds (BVS). METHODS AND RESULTS: We analysed procedural and clinical outcomes of all BVS implantations at a single centre where OCT guidance was mandatory in the initial rollout (OCT-mandatory) phase. We compared these data with the later phase where use of OCT was at operator discretion (OCT-selective or angiography). We implanted 406 BVS in 306 vessels (201 OCT, 105 angiography) in 272 patients. Follow-up duration was 38±10 months. Annualised rates of device-oriented cardiac events (DOCE) and scaffold thrombosis (ScT) were 1.4% and 0.4%, respectively. The risks of DOCE (HR 1.06, 95% CI: 0.33-3.34; p=0.71) and ScT (HR 0.48, 95% CI: 0.07-3.85; p=0.49) were not significantly different when comparing the OCT and angiography groups. CONCLUSIONS: Routine use of OCT to guide and optimise BVS implants results in very acceptable outcomes. Further, the benefits of such an early OCT-mandatory "learning" period persist after cessation of routine OCT usage when imaging is not routinely used. A period of mandatory OCT usage for BVS implants may therefore be beneficial in improving patient outcomes with these devices.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Angiografía Coronaria , Humanos , Andamios del Tejido , Tomografía de Coherencia Óptica , Resultado del Tratamiento
8.
BMC Cardiovasc Disord ; 18(1): 122, 2018 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-29921223

RESUMEN

BACKGROUND: Percutaneous coronary interventions (PCI) of old calcified saphenous vein grafts (SVGs) is challenging and is associated with a considerably high risk of adverse ischemic events in the short- and long-term as compared to native coronary arteries. We report a case in which a non-dilatable, calcified SVG lesion is successfully treated with rotational atherectomy followed by PCI and stenting with local stent delivery (LSD) technique using the Guidezilla™ guide extension catheter (5-in-6 Fr) in the "child-in-mother" fashion. CASE PRESENTATION: A 70 years-old man with a dilated ischemic cardiomyopathy, triple coronary artery bypass grafting (CABG) in 1990 and chronic renal failure (baseline GFR: 45 ml/min/1.73 m2) underwent a coronary angiography for a Non-ST segment elevation myocardial infarction (NSTEMI). Native coronary circulation was completely occluded at the proximal segments. Grafts angiography showed a tandem calcified lesions of SVG on distal right coronary artery (RCA) and an ostial stenosis of the SVG on first obtuse marginal branch (OM1). Left internal mammary artery on the mid left anterior descending artery was patent. Ad Hoc PCI of SVG on RCA was attempted. The proximal calcified stenosis has been crossed with a 1.5 x 12 mm balloon only with the support of Guidezilla™, however the non-compliant (NC) balloon 2.5 x 15 mm was unable to break the hard and calcified plaque. After several attempts, the procedure was interrupted with a suboptimal result. An elective transradial PCI of SVG on RCA with rotational atherectomy was performed. Two runs with 1.25 mm burr and 2 runs with 1.5 mm burr were carried out. Then, the use of distal anchoring balloon warranted support and tracking, made as centring rail for the advance of the tip of the "mother-and-child" catheter into the SVG. During slow deflation of the balloon, the Guidezilla™ was advanced distal to the stenoses to be stented, thus allowing the placement of two long drug eluting stents according to a LSD technique. CONCLUSIONS: Rotational atherectomy is a feasible option for non-dilatable stenoses in old SVGs when there is no evidence of thrombus or vessel dissection and the subsequent use of "mother-and-child" catheter has a key role, especially in case of radial approach, for long stents delivery.


Asunto(s)
Aterectomía Coronaria/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Puente de Arteria Coronaria/efectos adversos , Oclusión de Injerto Vascular/cirugía , Infarto del Miocardio sin Elevación del ST/cirugía , Intervención Coronaria Percutánea , Vena Safena/trasplante , Calcificación Vascular/cirugía , Anciano , Angiografía Coronaria , Stents Liberadores de Fármacos , Diseño de Equipo , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/etiología , Infarto del Miocardio sin Elevación del ST/fisiopatología , Intervención Coronaria Percutánea/instrumentación , Vena Safena/diagnóstico por imagen , Vena Safena/fisiopatología , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/etiología , Calcificación Vascular/fisiopatología , Grado de Desobstrucción Vascular
9.
Int J Cardiol ; 253: 27-28, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-29306467
11.
Clin Transplant ; 32(2)2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29194769

RESUMEN

OBJECTIVE: Cardiac allograft vasculopathy (CAV) can be detected early with intravascular ultrasound (IVUS), but there is limited information on the most efficient imaging protocol. METHODS: Coronary angiography and IVUS of the three coronary arteries were performed. Volumetric IVUS analysis was performed, and a Stanford grade determined for each vessel. RESULTS: Eighteen patients were included 18 (range 12-24) months after transplantation. Angiographic CAV severity ranged from none (CAV0) to mild (CAV1), whereas IVUS CAV severity ranged from none (Stanford grade I) to severe (grade IV). Maximal intimal thickness measured with IVUS was significantly greater in the LAD (0.84 ± 0.48 mm) than in the LCX (0.46 ± 0.32 mm) or the RCA (0.53 ± 0.41 mm, P = .005). Diagnostic accuracy of IVUS in the left anterior descending artery was 100% (18 of 18 Stanford grades matched the patient's highest overall Stanford grade), 66% in the right coronary artery (12 of 18), and 56% in the left circumflex artery (11 of 18). The minimal required length of left anterior descending artery pullbacks to attain 100% accuracy was 36 mm (range 3-36 mm) distal from the guide catheter ostium. CONCLUSIONS: These data suggest that focal IVUS imaging of the proximal LAD followed by volumetric analysis may suffice when screening for transplant vasculopathy.


Asunto(s)
Vasos Coronarios/patología , Rechazo de Injerto/diagnóstico , Trasplante de Corazón/efectos adversos , Complicaciones Posoperatorias , Ultrasonografía/métodos , Enfermedades Vasculares/diagnóstico , Adolescente , Adulto , Anciano , Aloinjertos , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Diagnóstico Precoz , Procedimientos Endovasculares , Femenino , Estudios de Seguimiento , Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/etiología , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/etiología , Adulto Joven
12.
Acta Cardiol ; 73(1): 19-27, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28685657

RESUMEN

OBJECTIVE: A new end point called ICD-resistant mortality was evaluated to assess the clinical efficacy of ICD implantations. METHODS AND RESULTS: In 302 ICD patients with ischaemic cardiomyopathy, we investigated which clinical parameters predicted useful ICD implantations using cumulative incidence competing risk analysis. Implantation was deemed clinically useful when the ICD provided appropriate therapy and the patient survived implantation by 1 year and the first shock by 30 days. ICD-resistant mortality (ICDRM) was defined as death within 30 days after the first shock, within 1 year of implantation or without previous appropriate ICD therapy. After 5 years, ICDRM occurred in 23% of implantations, while 36% were clinically useful. After multivariable analysis, ICDRM was associated with LVEF <35% (HR: 2.63; p = .005), beta-blocker dose <50% (HR: 2.0; p = .01) and anterior or diffuse infarct location (HR: 3.61; p = .001 and HR: 2.89; p = .02). Useful ICD implantations were associated with beta-blocker dose <50% (HR: 1.64; p = .02) and non-anterior infarct location (HR: 3.22 vs anterior and 1.59 vs diffuse; combined p<.001). CONCLUSIONS: Five years after implantation, an ICD could be classified as useful in 1 out of 3, while ICDRM occurred in one out of four patients. At 10 years, up to 80% of implantations could be categorized. Lower LVEF was related with significantly higher incidence of ICDRM. Anterior infarcts were associated with more ICDRM and less useful implantations than non-anterior infarcts. Future risk stratification for ICD should focus more on the discrimination between arrhythmic risk, probably preventable by ICDs and ICD-resistant mortality risk.


Asunto(s)
Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables , Cardioversión Eléctrica/mortalidad , Isquemia Miocárdica/terapia , Anciano , Bélgica/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 40(10): 1147-1159, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28857211

RESUMEN

BACKGROUND: A proportion of patients with an implantable cardioverter-defibrillator (ICD) in prevention of sudden cardiac death will only receive their first appropriate ICD therapy (AT) after device replacement. Clinical reassessment at the time of replacement could be helpful to guide the decision to replace or not in the future. METHODS: All patients with an ICD for primary or secondary prevention in ischemic (ICM) or nonischemic cardiomyopathy were included in a single-center retrospective registry. The association of changes in left ventricular ejection fraction (LVEF; cut-off at 35%), worsening renal function (decrease in estimated glomerular filtration rate > 15 mL/min), and worsening New York Heart Association class at elective device replacement with mortality and AT was analyzed using adjusted Cox regression analysis. RESULTS: A total of 238 (33%) out of 727 patients received elective device replacement (86.1% male, 74.4% ICM, 42.9% primary prevention). During this replacement 20.2% received a device upgrade. The mean time to replacement was 6.4 ± 2.0 years and mean follow-up after replacement was 3.4 ± 3.0 years. Of patients who did not receive AT before replacement 23.1% received their first AT after replacement. Worsening renal function (hazard ratio [HR] 2.79, 95% confidence interval [CI] 1.50-5.18) and a consistently LVEF ≤35% compared to a consistently LVEF >35% (HR 2.15, 95% CI 1.10-4.19) at the time of replacement were independent predictors of mortality. Independent predictors of first AT after replacement could not be identified. CONCLUSION: Although reassessment of LVEF and renal function at replacement can be helpful in predicting total mortality, the clinical utility to guide reimplantation seemed limited. Our experience indicates that approximately 25% of patients received their first AT only after replacement.


Asunto(s)
Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Desfibriladores Implantables , Riñón/fisiopatología , Función Ventricular Izquierda , Anciano , Cardiomiopatías/mortalidad , Femenino , Humanos , Masculino , Pronóstico , Estudios Retrospectivos
14.
Circ Cardiovasc Imaging ; 10(7)2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28687539

RESUMEN

BACKGROUND: The correlation between angiographic assessment of coronary stenoses and fractional flow reserve (FFR) is weak. Whether and how risk factors impact the diagnostic accuracy of angiography is unknown. We sought to evaluate the diagnostic accuracy of angiography by visual estimate and by quantitative coronary angiography when compared with FFR and evaluate the influence of risk factors (RF) on this accuracy. METHODS AND RESULTS: In 1382 coronary stenoses (1104 patients), percent diameter stenosis by visual estimation (DSVE) and by quantitative coronary angiography (DSQCA) was compared with FFR. Patients were divided into 4 subgroups, according to the presence of RFs, and the relationship between DSVE, DSQCA, and FFR was analyzed. Overall, DSVE was significantly higher than DSQCA (P<0.0001); nonetheless, when examined by strata of DS, DSVE was significantly smaller than DSQCA in mild stenoses, although the reverse held true for severe stenoses. Compared with FFR, a large scatter was observed for both DSVE and DSQCA. When using a dichotomous FFR value of 0.80, C statistic was significantly higher for DSVE than for DSQCA (0.712 versus 0.640, respectively; P<0.001). C statistics for DSVE decreased progressively as RFs accumulated (0.776 for ≤1 RF, 0.750 for 2 RFs, 0.713 for 3 RFs and 0.627 for ≥4 RFs; P=0.0053). In addition, in diabetics, the relationship between FFR and angiographic indices was particularly weak (C statistics: 0.524 for DSVE and 0.511 for DSQCA). CONCLUSIONS: Overall, DSVE has a better diagnostic accuracy than DSQCA to predict the functional significance of coronary stenosis. The predictive accuracy of angiography is moderate in patients with ≤1 RFs, but weakens as RFs accumulate, especially in diabetics.


Asunto(s)
Cateterismo Cardíaco , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Anciano , Bélgica , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Vasos Coronarios/fisiopatología , Bases de Datos Factuales , Angiopatías Diabéticas/diagnóstico por imagen , Angiopatías Diabéticas/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
15.
Circ Cardiovasc Interv ; 10(4)2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28400462

RESUMEN

BACKGROUND: During thermodilution-based assessment of volumetric coronary blood flow, we observed that intracoronary infusion of saline increased coronary flow. This study aims to quantify the extent and unravel the mechanisms of saline-induced hyperemia. METHODS AND RESULTS: Thirty-three patients were studied; in 24 patients, intracoronary Doppler flow velocity measurements were performed at rest, after intracoronary adenosine, and during increasing infusion rates of saline at room temperature through a dedicated catheter with 4 lateral side holes. In 9 patients, global longitudinal strain and flow propagation velocity were assessed by transthoracic echocardiography during a prolonged intracoronary saline infusion. Taking adenosine-induced maximal hyperemia as reference, intracoronary infusion of saline at rates of 5, 10, 15, and 20 mL/min induced 6%, 46%, 111%, and 112% of maximal hyperemia, respectively. There was a close agreement of maximal saline- and adenosine-induced coronary flow reserve (intraclass correlation coefficient, 0.922; P<0.001). The same infusion rates given through 1 end hole (n=6) or in the contralateral artery (n=6) did not induce a significant increase in flow velocity. Intracoronary saline given on top of an intravenous infusion of adenosine did not further increase flow. Intracoronary saline infusion did not affect blood pressure, systolic, or diastolic left ventricular function. Heart rate decreased by 15% during saline infusion (P=0.021). CONCLUSIONS: Intracoronary infusion of saline at room temperature through a dedicated catheter for coronary thermodilution induces steady-state maximal hyperemia at a flow rate ≥15 mL/min. These findings open new possibilities to measure maximal absolute coronary blood flow and minimal microcirculatory resistance.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria/fisiología , Vasos Coronarios/fisiopatología , Microcirculación/efectos de los fármacos , Cloruro de Sodio/administración & dosificación , Función Ventricular Izquierda/fisiología , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Enfermedad de la Arteria Coronaria/diagnóstico , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Hiperemia/fisiopatología , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Termodilución/métodos
17.
Pacing Clin Electrophysiol ; 39(8): 848-57, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27198580

RESUMEN

BACKGROUND: Clinical guidelines on implantable cardioverter defibrillator (ICD) therapy changed significantly in the last decades with potential inherent effects on therapy efficacy. We aimed to study therapy rates in time and the association between therapies and mortality. METHODS: All patients receiving an ICD, primary and secondary prevention, were included in a single-center retrospective registry. Information on first appropriate and inappropriate therapies was documented. Dates of implant were divided in P1: 1996-2001, P2: 2002-2008, and P3: 2009-2014. RESULTS: A total of 727 patients, 84.9% male-66.4% ischemic cardiomyopathy (ICM)-56% primary prevention-mean follow-up 5.2 ± 4.1 years, were included. There was a shift from secondary to primary prevention indications, from ischemic to non-ICM, and from single chamber to cardiac resynchronization therapy defibrillator devices. The annual 1- and 3-year appropriate shock (AS) rate declined from 29.4% and 15.1% in P1, over 13.3% and 9.2% in P2 to 7.8% and 5.7% in P3 (log-rank P < 0.001), while inappropriate shock (IAS) rates remained unchanged (log-rank P = 0.635). After multivariate regression analysis a higher age at implant, lower left ventricular ejection fraction, history of stroke, diabetes mellitus, intake of loop diuretics or digitalis, higher creatinine, and longer QTc were independent predictors of mortality. CONCLUSION: These changes in clinical practice with a shift to primary prevention and rise in non-ICM implants caused a significant decrease in AS incidence, while IAS remained stable. Receiving AS or IAS was not an independent predictor of mortality in our real-life cohort.


Asunto(s)
Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/prevención & control , Implantación de Prótesis/mortalidad , Distribución por Edad , Anciano , Bélgica/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pautas de la Práctica en Medicina/estadística & datos numéricos , Pautas de la Práctica en Medicina/tendencias , Prevalencia , Implantación de Prótesis/estadística & datos numéricos , Implantación de Prótesis/tendencias , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo
18.
Circulation ; 133(5): 502-8, 2016 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-26733607

RESUMEN

BACKGROUND: The fractional flow reserve (FFR) value of 0.75 has been validated against ischemic testing, whereas the FFR value of 0.80 has been widely accepted to guide clinical decision making. However, revascularization when FFR is 0.76 to 0.80, within the so-called gray zone, is still debatable. METHODS AND RESULTS: From February 1997 to June 2013, all patients with single-segment disease and an FFR value within the gray zone or within the 2 neighboring FFR strata (0.70-0.75 and 0.81-0.85) were included. Study end points consisted of major adverse cardiovascular events (death, myocardial infarction, and any revascularization) up to 5 years. Of 17 380 FFR measurements, 1459 patients were included. Of them, 449 patients were treated with revascularization and 1010 patients were treated with medical therapy. In the gray zone, the major adverse cardiovascular events rate was similar (37 [13.9%] versus 21 [11.2%], respectively; P=0.3) between medical therapy and revascularization, whereas a strong trend toward a higher rate of death or myocardial infarction (25 [9.4] versus 9 [4.8], P=0.06) and overall death (20 [7.5] versus 6 [3.2], P=0.059) was observed in the medical therapy group. Among medical therapy patients, a significant step-up increase in major adverse cardiovascular events rate was observed across the 3 FFR strata, especially with proximal lesion location. In revascularization patients, the major adverse cardiovascular events rate was not different across the 3 FFR strata. CONCLUSIONS: FFR in and around the gray zone bears a major prognostic value, especially in proximal lesions. These data confirm that FFR≤0.80 is valid to guide clinical decision making.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico/fisiología , Revascularización Miocárdica/métodos , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
JACC Cardiovasc Interv ; 8(11): 1422-1430, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26404193

RESUMEN

OBJECTIVES: The present study sought to establish the dosage of intracoronary (IC) adenosine associated with minimal side effects and above which no further increase in flow can be expected. BACKGROUND: Despite the widespread adoption of IC adenosine in clinical practice, no wide-ranging, dose-response study has been conducted. A recurring debate still exists regarding its optimal dose. METHODS: In 30 patients, Doppler-derived flow velocity measurements were obtained in 10 right coronary arteries (RCAs) and 20 left coronary arteries (LCAs) free of stenoses >20% in diameter. Flow velocity was measured at baseline and after 8 ml bolus administrations of arterial blood, saline, contrast medium, and 9 escalating doses of adenosine (4 to 500 µg). The hyperemic value was expressed in percent of the maximum flow velocity reached in a given artery (Q/Qmax, %). RESULTS: Q/Qmax did not increase significantly beyond dosages of 60 µg for the RCA and 160 µg for LCA. Heart rate did not change, whereas mean arterial blood pressure decreased by a maximum of 7% (p < 0.05) after bolus injections of IC adenosine. The incidence of transient A-V blocks was 40% after injection of 100 µg in the RCA and was 15% after injection of 200 µg in the LCA. The duration of the plateau reached 12 ± 13 s after injection of 100 µg in the RCA and 21 ± 6 s after the injection of 200 µg in the LCA. A progressive prolongation of the time needed to return to baseline was observed. Hyperemic response after injection of 8 ml of contrast medium reached 65 ± 36% of that achieved after injection of 200 µg of adenosine. CONCLUSIONS: This wide-ranging, dose-response study indicates that an IC adenosine bolus injection of 100 µg in the RCA and 200 µg in the LCA induces maximum hyperemia while being associated with minimal side effects.


Asunto(s)
Adenosina/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/efectos de los fármacos , Hiperemia/fisiopatología , Vasodilatación/efectos de los fármacos , Vasodilatadores/administración & dosificación , Adenosina/efectos adversos , Anciano , Velocidad del Flujo Sanguíneo , Medios de Contraste/administración & dosificación , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Relación Dosis-Respuesta a Droga , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Factores de Tiempo , Vasodilatadores/efectos adversos
20.
Europace ; 16(7): 1069-77, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24196450

RESUMEN

AIMS: In high-risk patients, implantable cardioverter-defibrillators (ICDs) can convert the mode of death from arrhythmic to pump failure death. Therefore, we introduced the concept of 'ICD-resistant mortality' (IRM), defined as death (a) without previous appropriate ICD intervention (AI), (b) within 1 month after the first AI, or (c) within 1 year after the initial ICD implantation. Implantable cardioverter-defibrillator implantation in patients with a high risk of IRM should be avoided. METHODS AND RESULTS: Implantable cardioverter-defibrillator patients with ischaemic heart disease were included if a digitized 24 h Holter was available pre-implantation. Demographic, electrocardiographic, echocardiographic, and 24 h Holter risk factors were collected at device implantation. The primary endpoint was IRM. Cox regression analyses were used to test the association between predictors and outcome. We included 130 patients, with a mean left ventricular ejection fraction (LVEF) of 33.6 ± 10.3%. During a follow-up of 52 ± 31 months, 33 patients died. There were 21 cases of IRM. Heart rate turbulence (HRT) was the only Holter parameter associated with IRM and total mortality. A higher New York Heart Association (NYHA) class and a lower body mass index were the strongest predictors of IRM. Left ventricular ejection fraction predicted IRM on univariate analysis, and was the strongest predictor of total mortality. The only parameter that predicted AI was non-sustained ventricular tachycardia. CONCLUSION: Implantable cardioverter-defibrillator implantation based on NYHA class and LVEF leads to selection of patients with a higher risk of IRM and death. Heart rate turbulence may have added value for the identification of poor candidates for ICD therapy. Available Holter parameters seem limited in their ability to predict AI.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Frecuencia Cardíaca , Isquemia Miocárdica/complicaciones , Taquicardia Ventricular/terapia , Anciano , Índice de Masa Corporal , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Electrocardiografía Ambulatoria , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Selección de Paciente , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/mortalidad , Factores de Tiempo , Insuficiencia del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...