1.
PLoS One ; 17(12): e0278749, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36542608

RESUMEN

The Democratic Republic of the Congo (DRC) has a high measles incidence despite elimination efforts and has yet to introduce rubella vaccine. We evaluated the performance of a prototype rapid digital microfluidics powered (DMF) enzyme-linked immunoassay (ELISA) assessing measles and rubella infection, by testing for immunoglobulin M (IgM), and immunity from natural infection or vaccine, by testing immunoglobulin G (IgG), in outbreak settings. Field evaluations were conducted during September 2017, in Kinshasa province, DRC. Blood specimens were collected during an outbreak investigation of suspected measles cases and tested for measles and rubella IgM and IgG using the DMF-ELISA in the field. Simultaneously, a household serosurvey for measles and rubella IgG was conducted in a recently confirmed measles outbreak area. DMF-ELISA results were compared with reference ELISA results tested at DRC's National Public Health Laboratory and the US Centers for Disease Control and Prevention. Of 157 suspected measles cases, rubella IgM was detected in 54% while measles IgM was detected in 13%. Measles IgG-positive cases were higher among vaccinated persons (87%) than unvaccinated persons (72%). In the recent measles outbreak area, measles IgG seroprevalence was 93% overall, while rubella seroprevalence was lower for children (77%) than women (98%). Compared with reference ELISA, DMF-ELISA sensitivity and specificity were 82% and 78% for measles IgG; 88% and 89% for measles IgM; 85% and 85% for rubella IgG; and 81% and 83% for rubella IgM, respectively. Rubella infection was detected in more than half of persons meeting the suspected measles case definition during a presumed measles outbreak, suggesting substantial unrecognized rubella incidence, and highlighting the need for rubella vaccine introduction into the national schedule. The performance of the DMF-ELISA suggested that this technology can be used to develop rapid diagnostic tests for measles and rubella.


Asunto(s)
Sarampión , Rubéola (Sarampión Alemán) , Niño , Humanos , Femenino , República Democrática del Congo/epidemiología , Estudios Seroepidemiológicos , Microfluídica , Anticuerpos Antivirales , Rubéola (Sarampión Alemán)/diagnóstico , Rubéola (Sarampión Alemán)/epidemiología , Rubéola (Sarampión Alemán)/prevención & control , Sarampión/diagnóstico , Sarampión/epidemiología , Sarampión/prevención & control , Vacuna contra la Rubéola , Inmunoglobulina M , Inmunoglobulina G , Técnicas para Inmunoenzimas , Brotes de Enfermedades
2.
Langmuir ; 35(15): 5342-5352, 2019 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-30958677

RESUMEN

In digital microfluidics, discrete droplets of fluid are made to move on an open surface with no microchannels. These systems are commonly operated by application of electrical driving forces to an array of electrodes. While these driving forces are well characterized, the dissipative forces opposing droplet movement have not been as thoroughly examined. In recognition of this deficit, we used force-velocity plots to characterize droplet movement in digital microfluidics, which was found to be consistent with a simple theoretical framework for understanding dissipation effects for droplets in two-plate, air-filled devices. Interestingly, in some conditions, a previously unreported ″velocity saturation″ effect was observed. When examined across a range of different liquids, the forces at which this saturation occurs seem to be lower for liquids with smaller surface tensions. Furthermore, when driven at forces that cause saturation, physical phenomena are observed that are akin to what has been reported for stationary droplets in the electrowetting literature. These phenomena are detrimental to device performance, leading to a new "force window" approach that delineates the optimum operation conditions for different liquids. We propose that these findings may be useful for a wide range of applications for experts and new users alike in this growing field.

3.
Sci Transl Med ; 10(438)2018 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-29695457

RESUMEN

Serosurveys are useful for assessing population susceptibility to vaccine-preventable disease outbreaks. Although at-risk populations in remote areas could benefit from this type of information, they face several logistical barriers to implementation, such as lack of access to centralized laboratories, cold storage, and transport of samples. We describe a potential solution: a compact and portable, field-deployable, point-of-care system relying on digital microfluidics that can rapidly test a small volume of capillary blood for disease-specific antibodies. This system uses inexpensive, inkjet-printed digital microfluidic cartridges together with an integrated instrument to perform enzyme-linked immunosorbent assays (ELISAs). We performed a field validation of the system's analytical performance at Kakuma refugee camp, a remote setting in northwestern Kenya, where we tested children aged 9 to 59 months and caregivers for measles and rubella immunoglobulin G (IgG). The IgG assays were determined to have sensitivities of 86% [95% confidence interval (CI), 79 to 91% (measles)] and 81% [95% CI, 73 to 88% (rubella)] and specificities of 80% [95% CI, 49 to 94% (measles)] and 91% [95% CI, 76 to 97% (rubella)] (measles, n = 140; rubella, n = 135) compared with reference tests (measles IgG and rubella IgG ELISAs from Siemens Enzygnost) conducted in a centralized laboratory. These results demonstrate a potential role for this point-of-care system in global serological surveillance, particularly in remote areas with limited access to centralized laboratories.


Asunto(s)
Inmunoensayo/métodos , Microfluídica/métodos , Preescolar , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoglobulina G/sangre , Lactante , Masculino , Sistemas de Atención de Punto
4.
Anal Chem ; 89(8): 4330-4338, 2017 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-28379683

RESUMEN

Isaac Newton famously observed that "if I have seen further it is by standing on the shoulders of giants." We propose that this sentiment is a powerful motivation for the "open-source" movement in scientific research, in which creators provide everything needed to replicate a given project online, as well as providing explicit permission for users to use, improve, and share it with others. Here, we write to introduce analytical chemists who are new to the open-source movement to best practices and concepts in this area and to survey the state of open-source research in analytical chemistry. We conclude by considering two examples of open-source projects from our own research group, with the hope that a description of the process, motivations, and results will provide a convincing argument about the benefits that this movement brings to both creators and users.

5.
Lab Chip ; 16(23): 4560-4568, 2016 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-27801455

RESUMEN

The diagnosis of infectious disease is typically carried out at the point-of-care (POC) using the lateral flow assay (LFA). While cost-effective and portable, LFAs often lack the clinical sensitivity and specificity required for accurate diagnoses. In response to this challenge, we introduce a new digital microfluidic (DMF) platform fabricated using a custom inkjet printing and roll-coating process that is scalable to mass production. The performance of the new devices is on par with that of traditional DMF devices fabricated in a cleanroom, with a materials cost for the new devices of only US $0.63 per device. To evaluate the usefulness of the new platform, we performed a 13-step rubella virus (RV) IgG immunoassay on the inkjet printed, roll-coated devices, which yielded a limit of detection of 0.02 IU mL-1, well below the diagnostic cut-off of 10 IU mL-1 for RV infection and immunity. We propose that this represents a breakthrough for DMF, lowering the costs to a level such that the new platforms will be an attractive alternative to LFAs for the diagnosis of infectious disease at the POC.


Asunto(s)
Costos y Análisis de Costo , Tinta , Dispositivos Laboratorio en un Chip/economía , Sistemas de Atención de Punto , Impresión , Ensayo de Inmunoadsorción Enzimática , Diseño de Equipo , Inmunoglobulina G/análisis , Virus de la Rubéola/inmunología , Virus de la Rubéola/aislamiento & purificación
6.
Adv Mater ; 26(18): 2838-43, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24458780

RESUMEN

The first example of so-called "digital microfluidics" (DMF) implemented on paper by inkjet printing is reported. A sandwich enzyme-linked immunosorbent assay (ELISA) is demonstrated as an example of a complex, multistep protocol that would be difficult to achieve with capillary-driven paper microfluidics. Furthermore, it is shown that paper-based DMF devices have comparable performance to traditional photolithographically patterned DMF devices at a fraction of the cost.


Asunto(s)
Equipos Desechables , Ensayo de Inmunoadsorción Enzimática/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Papel , Impresión Tridimensional , Tiras Reactivas , Procesamiento de Señales Asistido por Computador/instrumentación , Periféricos de Computador , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
7.
Small ; 10(6): 1184-93, 2014 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-24376046

RESUMEN

Efforts to develop self-contained microreactors and artificial cells have been limited by difficulty in generating membranes that can be robustly and repeatedly manipulated to load and release cargo from phospholipid compartments. Here we describe a purely optical method to form pores in a membrane generated from porphyrin-phospholipid conjugates electro-assembled into microscale giant porphyrin vesicles and manipulated using confocal microscopy. The pores in the membrane resealed within a minute allowing for repeated pore formation with precise spatial and temporal control and optical gating to allow selective diffusion of biomolecules across the membrane. Temporal control of pore formation was illustrated by performing sequential DNA hybridization reactions. A biotin-avidin based strategy was developed to selectively attach enzymes to the interior of the vesicle, demonstrating spatial control and the potential of giant porphyrin vesicles as versatile microreactors.


Asunto(s)
Liposomas/química , Fenómenos Ópticos , Porfirinas/química , ADN/metabolismo , Difusión , Tamaño de la Partícula , Porosidad , Factores de Tiempo
8.
Anal Chem ; 85(20): 9638-46, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23978190

RESUMEN

We introduce an automated digital microfluidic (DMF) platform capable of performing immunoassays from sample to analysis with minimal manual intervention. This platform features (a) a 90 Pogo pin interface for digital microfluidic control, (b) an integrated (and motorized) photomultiplier tube for chemiluminescent detection, and (c) a magnetic lens assembly which focuses magnetic fields into a narrow region on the surface of the DMF device, facilitating up to eight simultaneous digital microfluidic magnetic separations. The new platform was used to implement a three-level full factorial design of experiments (DOE) optimization for thyroid-stimulating hormone immunoassays, varying (1) the analyte concentration, (2) the sample incubation time, and (3) the sample volume, resulting in an optimized protocol that reduced the detection limit and sample incubation time by up to 5-fold and 2-fold, respectively, relative to those from previous work. To our knowledge, this is the first report of a DOE optimization for immunoassays in a microfluidic system of any format. We propose that this new platform paves the way for a benchtop tool that is useful for implementing immunoassays in near-patient settings, including community hospitals, physicians' offices, and small clinical laboratories.

9.
Integr Biol (Camb) ; 5(8): 1014-25, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23770992

RESUMEN

The potential benefits of using new technologies such as microfluidics for life science applications are exciting, but it is critical to understand and document potential biases imposed by these technologies on the observed results. Here, we report the first study of genome-level effects on cells manipulated by digital microfluidics. These effects were evaluated using a broad suite of tools: cell-based stress sensors for heat shock activation, single-cell COMET assays to probe changes in DNA integrity, and DNA microarrays and qPCR to evaluate changes in genetic expression. The results lead to two key observations. First, most DMF operating conditions tested, including those that are commonly used in the literature, result in negligible cell-stress or genome-level effects. Second, for DMF devices operated at high driving frequency (18 kHz) and with large driving electrodes (10 mm × 10 mm), there are significant damage to DNA integrity and differential genomic regulation. We hypothesize that these effects are caused by droplet heating. We recommend that for DMF applications involving mammalian cells that driving frequencies be kept low (≤ 10 kHz) and electrode sizes be kept small (≤ 5 mm) to avoid detrimental effects.


Asunto(s)
Microfluídica/métodos , Animales , Apoptosis , Ensayo Cometa , ADN/química , Electrodos , Citometría de Flujo , Perfilación de la Expresión Génica , Proteínas Fluorescentes Verdes/química , Calor , Ratones , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos , Fenotipo , Reacción en Cadena de la Polimerasa
10.
Biosens Bioelectron ; 42: 314-20, 2013 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-23208104

RESUMEN

We report the first digital microfluidic (DMF) system capable of impedance sensing of mammalian cells. The new system was validated in three assays: calibration, proliferation, and serum sensing. In the first assay, three cell lines (HeLa, CHO-K1, and NIH-3T3) were seeded at different densities to determine the relationship between impedance and cell number, which was found to be linear for each type of cell. In the proliferation assay, cells were grown for four days and their proliferation rates were determined by regular impedance measurements. In the serum sensing assay, a dilution series of cell media containing different concentrations of serum was evaluated using impedance measurements to determine the optimum conditions for proliferation. The DMF impedance system is label-free, does not require imaging, and is compatible with long-term cell culture. We propose that this system will be useful for the growing number of scientists who are seeking methods other than fluorescence or cell sorting to analyze adherent cells in situ.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas de Cultivo de Célula/métodos , Impedancia Eléctrica , Microfluídica/métodos , Animales , Proliferación Celular , Células HeLa , Humanos , Ratones , Células 3T3 NIH
11.
Artículo en Inglés | MEDLINE | ID: mdl-22524226

RESUMEN

Digital microfluidics (DMF) is an emerging liquid-handling technology that enables individual control over droplets on an open array of electrodes. These picoliter- to microliter-sized droplets, each serving as an isolated vessel for chemical processes, can be made to move, merge, split, and dispense from reservoirs. Because of its unique advantages, including simple instrumentation, flexible device geometry, and easy coupling with other technologies, DMF is being applied to a wide range of fields. In this review, we summarize the state of the art of DMF technology from the perspective of analytical chemistry in sections describing the theory of droplet actuation, device fabrication and integration, and applications.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Animales , Técnicas de Cultivo de Célula/instrumentación , Técnicas de Química Analítica/instrumentación , ADN/análisis , Pruebas de Enzimas/instrumentación , Diseño de Equipo , Humanos , Inmunoensayo/instrumentación , Proteómica/instrumentación
12.
Anal Chem ; 84(8): 3731-8, 2012 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-22413743

RESUMEN

Dried blood spot (DBS) samples on filter paper are surging in popularity as a sampling and storage vehicle for a wide range of clinical and pharmaceutical applications. For example, a DBS sample is collected from every baby born in the province of Ontario, Canada, for quantification of approximately one hundred analytes that are used to screen for 28 conditions, including succinylacetone (SA), a marker for hepatorenal tyrosinemia. Unfortunately, the conventional methods used to evaluate DBS samples for newborn screening and other applications are tedious and slow, with limited options for automated analysis. In response to this challenge, we have developed a method to couple digital microfluidics (DMF) to nanoelectrospray ionization mass spectrometry (nESI-MS) for SA quantification in DBS samples. The new system is formed by sandwiching a pulled glass capillary emitter between the two DMF substrates such that the capillary emitter is immobilized without external seals or gaskets. Moreover, we introduce a new feedback control system that enables high-fidelity droplet manipulation across DBS samples without manual intervention. The system was validated by application to on-chip extraction, derivatization, and analysis of SA and other analytes from DBS samples, with comparable performance to gold-standard methods. We propose that the new methods described here can potentially contribute to a new generation of analytical techniques for quantifying analytes in DBS samples for a wide range of applications.


Asunto(s)
Pruebas con Sangre Seca , Microfluídica , Espectrometría de Masa por Ionización de Electrospray , Aminoácidos/análisis , Aminoácidos/sangre , Automatización , Cromatografía Liquida/métodos , Heptanoatos/análisis , Heptanoatos/sangre , Humanos
13.
Lab Chip ; 11(3): 535-40, 2011 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-21038034

RESUMEN

Digital microfluidics (DMF) is a technique in which discrete droplets are manipulated by applying electrical fields to an array of electrodes. In an ideal DMF system, each application of driving potential would cause a targeted droplet to move onto an energized electrode (i.e., perfect fidelity between driving voltage and actuation); however, in real systems, droplets are sometimes observed to resist movement onto particular electrodes. Here, we implement a sensing and feedback control system in which all droplet movements are monitored, such that when a movement failure is observed, additional driving voltages can be applied until the droplet completes the desired operation. The new system was evaluated for a series of liquids including water, methanol, and cell culture medium containing fetal bovine serum, and feedback control was observed to result in dramatic improvements in droplet actuation fidelity and velocity. The utility of the new system was validated by implementing an enzyme kinetics assay with continuous mixing. The new platform for digital microfluidics is simple and inexpensive and thus should be useful for scientists and engineers who are developing automated analysis platforms.


Asunto(s)
Bioensayo/métodos , Retroalimentación , Técnicas Analíticas Microfluídicas/métodos , Células Cultivadas , Medios de Cultivo/química , Electrodos , Agua/química
14.
J Magn Reson Imaging ; 31(2): 328-38, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20099345

RESUMEN

PURPOSE: To evaluate three multicoil breast arrays for both conventional and SENSE-accelerated imaging. MATERIALS AND METHODS: Two commercially available 8-element coils and a prototype 16-element coil were compared. One 8-element array had adjustable coils located next to the breast tissue and the other had a fixed coil arrangement; both were designed to allow parallel imaging in the left-right direction. The 16-element coil was designed to have coil sensitivity variation in both the left-right and superior-inferior directions, and also had adjustable coils. Their performance was assessed in terms of signal-to-noise ratio (SNR), g-factor, and uniformity with a custom-built phantom. RESULTS: The 16-element array with adjustable coils provided the highest SNR, while the 8-element coil with a fixed coil arrangement had the best uniformity. All coils performed well for SENSE acceleration in the left-right direction. The 8-element coils did not have the capability for acceleration in the superior-inferior direction across the whole volume. The 16-element coil enabled acceleration in the superior-inferior direction in addition to the left-right direction. CONCLUSION: Smaller, adjustable coil elements located next to breast tissue can provide greater SNR than larger, fixed coil elements. A multicoil breast array with high intrinsic SNR and low g-factors enables high-quality parallel imaging.


Asunto(s)
Mama/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Vis Exp ; (33)2009 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-19898419

RESUMEN

Clinical proteomics has emerged as an important new discipline, promising the discovery of biomarkers that will be useful for early diagnosis and prognosis of disease. While clinical proteomic methods vary widely, a common characteristic is the need for (i) extraction of proteins from extremely heterogeneous fluids (i.e. serum, whole blood, etc.) and (ii) extensive biochemical processing prior to analysis. Here, we report a new digital microfluidics (DMF) based method integrating several processing steps used in clinical proteomics. This includes protein extraction, resolubilization, reduction, alkylation and enzymatic digestion. Digital microfluidics is a microscale fluid-handling technique in which nanoliter-microliter sized droplets are manipulated on an open surface. Droplets are positioned on top of an array of electrodes that are coated by a dielectric layer - when an electrical potential is applied to the droplet, charges accumulate on either side of the dielectric. The charges serve as electrostatic handles that can be used to control droplet position, and by biasing a sequence of electrodes in series, droplets can be made to dispense, move, merge, mix, and split on the surface. Therefore, DMF is a natural fit for carrying rapid, sequential, multistep, miniaturized automated biochemical assays. This represents a significant advance over conventional methods (relying on manual pipetting or robots), and has the potential to be a useful new tool in clinical proteomics.


Asunto(s)
Técnicas Analíticas Microfluídicas/métodos , Proteínas/análisis , Proteómica/métodos , Animales , Automatización de Laboratorios/instrumentación , Automatización de Laboratorios/métodos , Bovinos , Técnicas Analíticas Microfluídicas/instrumentación , Proteómica/instrumentación , Albúmina Sérica Bovina/análisis