Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Physiol ; 12: 624317, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33889086

RESUMEN

BACKGROUND: Abnormal synchronization of neuronal activity in dopaminergic circuits is related to motor impairment in Parkinson's disease (PD). Vibrotactile coordinated reset (vCR) fingertip stimulation aims to counteract excessive synchronization and induce sustained unlearning of pathologic synaptic connectivity and neuronal synchrony. Here, we report two clinical feasibility studies that examine the effect of regular and noisy vCR stimulation on PD motor symptoms. Additionally, in one clinical study (study 1), we examine cortical beta band power changes in the sensorimotor cortex. Lastly, we compare these clinical results in relation to our computational findings. METHODS: Study 1 examines six PD patients receiving noisy vCR stimulation and their cortical beta power changes after 3 months of daily therapy. Motor evaluations and at-rest electroencephalographic (EEG) recordings were assessed off medication pre- and post-noisy vCR. Study 2 follows three patients for 6+ months, two of whom received daily regular vCR and one patient from study 1 who received daily noisy vCR. Motor evaluations were taken at baseline, and follow-up visits were done approximately every 3 months. Computationally, in a network of leaky integrate-and-fire (LIF) neurons with spike timing-dependent plasticity, we study the differences between regular and noisy vCR by using a stimulus model that reproduces experimentally observed central neuronal phase locking. RESULTS: Clinically, in both studies, we observed significantly improved motor ability. EEG recordings observed from study 1 indicated a significant decrease in off-medication cortical sensorimotor high beta power (21-30 Hz) at rest after 3 months of daily noisy vCR therapy. Computationally, vCR and noisy vCR cause comparable parameter-robust long-lasting synaptic decoupling and neuronal desynchronization. CONCLUSION: In these feasibility studies of eight PD patients, regular vCR and noisy vCR were well tolerated, produced no side effects, and delivered sustained cumulative improvement of motor performance, which is congruent with our computational findings. In study 1, reduction of high beta band power over the sensorimotor cortex may suggest noisy vCR is effectively modulating the beta band at the cortical level, which may play a role in improved motor ability. These encouraging therapeutic results enable us to properly plan a proof-of-concept study.

2.
Clin Neurophysiol ; 131(1): 193-198, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31809982

RESUMEN

OBJECTIVE: To assay EEG signal quality recorded with tripolar concentric ring electrodes (TCREs) compared to regular EEG electrodes. METHODS: EEG segments were recorded simultaneously by TCREs and regular electrodes, low-pass filtered at 35 Hz (REG35) and 70 Hz (REG70). Clips were rated blindly by nine electroencephalographers for presence or absence of key EEG features, relative to the "gold-standard" of the clinical report. RESULTS: TCRE showed less EMG artifact (F = 15.4, p < 0.0001). Overall quality rankings were not significantly different. Focal slowing was better detected by TCRE and spikes were better detected by regular electrodes. Seizures (n = 85) were detected by TCRE in 64 cases (75.3%), by REG70 in 75 (88.2%) and REG35 in 69 (81.2%) electrodes. TCRE detected 9 (10.6%) seizures not detected by one of the other 2 methods. In contrast, 14 seizures (16.5%) were not detected by TCRE, but were by REG35 electrodes. Each electrode detected interictal spikes when the other did not. CONCLUSIONS: TCRE produced similar overall quality and confidence ratings versus regular electrodes, but less muscle artifact. TCRE recordings detected seizures in 7% of instances where regular electrodes did not. SIGNIFICANCE: The combination of the two types increased detection of epileptiform events compared to either alone.


Asunto(s)
Artefactos , Electrodos , Electroencefalografía/instrumentación , Diseño de Equipo , Convulsiones/fisiopatología , Calibración , Electroencefalografía/normas , Humanos , Músculos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...