1.
Bioengineering (Basel) ; 10(5)2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37237696

RESUMEN

Delamination at heterogeneous material interfaces is one of the most prominent failure modes in active implantable medical devices (AIMDs). A well-known example of an AIMD is the cochlear implant (CI). In mechanical engineering, a multitude of testing procedures are known whose data can be used for detailed modeling with respect to digital twins. Detailed, complex models for digital twins are still lacking in bioengineering since body fluid infiltration occurs both into the polymer substrate and along the metal-polymer interfaces. For a newly developed test for an AIMD or CI composed of silicone rubber and metal wiring or electrodes, a mathematical model of these mechanisms is presented. It provides a better understanding of the failure mechanisms in such devices and their validation against real-life data. The implementation utilizes COMSOL Multiphysics®, consisting of a volume diffusion part and models for interface diffusion (and delamination). For a set of experimental data, the necessary diffusion coefficient could be derived. A subsequent comparison of experimental and modeling results showed a good qualitative and functional match. The delamination model follows a mechanical approach. The results of the interface diffusion model, which follows a substance transport-based approach, show a very good approximation to the results of previous experiments.

2.
Polymers (Basel) ; 14(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35566935

RESUMEN

The gold standard for the partial restoration of sensorineural hearing loss is cochlear implant surgery, which restores patients' speech comprehension. The remaining limitations, e.g., music perception, are partly due to a gap between cochlear implant electrodes and the auditory nerve cells in the modiolus of the inner ear. Reducing this gap will most likely lead to improved cochlear implant performance. To achieve this, a bending or curling mechanism in the electrode array is discussed. We propose a silicone rubber-hydrogel actuator where the hydrogel forms a percolating network in the dorsal silicone rubber compartment of the electrode array to exert bending forces at low volume swelling ratios. A material study of suitable polymers (medical-grade PDMS and hydrogels), including parametrized bending curvature measurements, is presented. The curvature radii measured meet the anatomical needs for positioning electrodes very closely to the modiolus. Besides stage-one biocompatibility according to ISO 10993-5, we also developed and validated a simplified mathematical model for designing hydrogel-actuated CI with modiolar hugging functionality.

3.
Nanomaterials (Basel) ; 11(12)2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34947600

RESUMEN

Galinstan, a liquid metal at room temperature, is a promising material for use in flexible electronics. Since it has been successfully integrated in devices for external use, e.g., as stretchable electronic skin in tactile sensation, the possibility of using galinstan for flexible implant technology comes to mind. Usage of liquid metals in a flexible implant would reduce the risk of broken conductive pathways in the implants and therefore reduce the possibility of implant failure. However, the biocompatibility of the liquid metal under study, i.e., galinstan, has not been proven in state-of-the-art literature. Therefore, in this paper, a material combination of galinstan and silicone rubber is under investigation regarding the success of sterilization methods and to establish biocompatibility testing for an in vivo application. First cell biocompatibility tests (WST-1 assays) and cell toxicity tests (LDH assays) show promising results regarding biocompatibility. This work paves the way towards the successful integration of stretchable devices using liquid metals embedded in a silicone rubber encapsulant for flexible surface electro-cortical grid arrays and other flexible implants.

4.
Nanomaterials (Basel) ; 11(4)2021 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-33920671

RESUMEN

Current developments of electrodes for neural recordings address the need of biomedical research and applications for high spatial acuity in electrophysiological recordings. One approach is the usage of novel materials to overcome electrochemical constraints of state-of-the-art metal contacts. Promising materials are carbon nanotubes (CNTs), as they are well suited for neural interfacing. The CNTs increase the effective contact surface area to decrease high impedances while keeping minimal contact diameters. However, to prevent toxic dissolving of CNTs, an appropriate surface coating is required. In this study, we tested flexible surface electrocorticographic (ECoG) electrodes, coated with a CNT-silicone rubber composite. First, we describe the outcome of surface etching, which exposes the contact nanostructure while anchoring the CNTs. Subsequently, the ECoG electrodes were used for acute in vivo recordings of auditory evoked potentials from the guinea pig auditory cortex. Both the impedances and the signal-to-noise ratios of coated contacts were similar to uncoated gold contacts. This novel approach for a safe application of CNTs, embedded in a surface etched silicone rubber, showed promising results but did not lead to improvements during acute recordings.