Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38944191

RESUMEN

OBJECTIVES: To describe the outcomes of aortic endograft thrombosis (AET) as an indication for open conversion (OC) after endovascular aortic aneurysm repair (EVAR) in a multicenter experience. METHODS: This study retrospectively analyzed cases of OC for AET following EVAR across 12 Italian Vascular Surgery centers from 1997 to September 2022. The endpoints were as follows: 30-days mortality and major postoperative complications. Follow-up data included: survival and aortic-related complications. RESULTS: Sixteen patients (mean age: 68.6±8.5 years) were included. Median elapsed time between EVAR to OC was 26.46 months (IQR 13.8-45.9). Proximal aortic cross-clamping site was supraceliac in 8 out of 16 (50%) patients, complete removal of the stentgraft was achieved in 75% of cases (12/16 patients). Reconstructions were: aorto-bi-iliac grafts in 8 cases (50%), 7 aorto-bi-femoral bypass grafts (43.8%), and 1 aorto-aortic tube graft (6.3%). All patients were symptomatic at presentation (68.7% unilateral acute limb ischemia, 25% bilateral acute limb ischemia, 1 patient had chronic severe claudication). Thirty-day mortality was 12.5% (2/16 patients). Overall morbidity rate was 43.8% (7 of 16 patients). No specific risk factors for early mortality were found. The overall estimated survival rate was 80.4% at 1 year, 62.5% at 2 years and 41.7% at 3 years. CONCLUSIONS: OC for AET is typically reserved for complex cases that are not amenable to endovascular solutions. The frequent need for suprarenal clamping and complete endograft removal seem to be associated with high short-term mortality.

2.
Diagnostics (Basel) ; 14(10)2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38786352

RESUMEN

Vascular calcifications in aorto-iliac arteries are emerging as crucial risk factors for cardiovascular diseases (CVDs) with profound clinical implications. This systematic review, following PRISMA guidelines, investigated methodologies for measuring these calcifications and explored their correlation with CVDs and clinical outcomes. Out of 698 publications, 11 studies met the inclusion criteria. In total, 7 studies utilized manual methods, while 4 studies utilized automated technologies, including artificial intelligence and deep learning for image analyses. Age, systolic blood pressure, serum calcium, and lipoprotein(a) levels were found to be independent risk factors for aortic calcification. Mortality from CVDs was correlated with abdominal aorta calcification. Patients requiring reintervention after endovascular recanalization exhibited a significantly higher volume of calcification in their iliac arteries. Conclusions: This review reveals a diverse landscape of measurement methods for aorto-iliac calcifications; however, they lack a standardized reproducibility assessment. Automatic methods employing artificial intelligence appear to offer broader applicability and are less time-consuming. Assessment of calcium scoring could be routinely employed during preoperative workups for risk stratification and detailed surgical planning. Additionally, its correlation with clinical outcomes could be useful in predicting the risk of reinterventions and amputations.

3.
Int Angiol ; 43(2): 271-279, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38502543

RESUMEN

INTRODUCTION: The purpose of this study is to report incidence, indications, and outcomes of early open conversions (EOC) after endovascular aortic repair (EVAR), defined as surgical conversion performed within 30 days from the initial EVAR. EVIDENCE AQUISITION: A systematic review of the literature was performed (database searched: PubMed, Web of Science, Scopus, Cochrane Library; last search April 2023). Articles reporting EOC after EVAR comprising at least five patients were included. Meta-analyses of proportions were performed using a random-effects model. EVIDENCE SYNTHESIS: Seventeen non-randomized studies, published between 1999 and 2022, were included. A total of 35,970 patients had previously undergone EVAR, of these 438 patients underwent EOC. Estimated incidence of EOC was 1.4% (95% CI 1.1-1.4; I2=81.66%). Specifically, in the works published before 2010 the incidence was 1.8% (95% CI 1.3-2.4; I2=74.25) while for subsequent ones it was 0.9% (95% CI 0.6-1.1; I2=69.82). Weighted mean age was 74.91 years (95% CI 72.42-77.39; I2=83.11%). Estimated rate of cause determining EOC were: access issue in 27.7% of patients (95% CI 13.8-41.6; I2=88.14%), incorrect placement of the endograft in 20.1% (95% CI 10.2-30.0; I2=76,9%), problems with "delivery system" in 9.0% (95% CI 4.9-13.1; I2=0%), aorto-iliac rupture in 8.6% (95% CI 4.5-12.6; I2=0%), endoprosthesis migration in 7.9% of cases (95% CI 3.3-12.4; I2=22.96%), failure in engaging the contralateral gate in 4.8% (95% CI 1.6-8; I2=0%), "kinking" or "twisting" of endoprosthesis in 3.3% (95% CI 0.6-5.9; I2=0%), graft thrombosis in 3.2% (95% CI 0.6-5.7; I2=0%), type Ia endoleak in 2.9% (95% CI 0.4-5.4; I2=0%), type III endoleak in 2.8% (95% CI 0.3-5.3; I2=0%) and endograft infection in 2.7% (95% CI 0.3-5.2; I2=0%). Intraoperative conversion rate was 91.1% (95% CI 85.8-96.4; I2=66.01%). Early mortality rate after EOC was 14.5% (95% CI 9.1-19.9; I2=48.31%). Mean length of stay (LOS) was 11.94 days (95% CI 6.718-17.172; I2=92.34%). CONCLUSIONS: The incidence of EOC seems to decrease over time. Causes of EOC were mainly related to access problems and incorrect positioning of the endograft. Most of the EOC were performed intraoperatively carrying a high mortality rate.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Incidencia , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Resultado del Tratamiento , Conversión a Cirugía Abierta , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Factores de Tiempo
4.
Bioengineering (Basel) ; 11(2)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38391683

RESUMEN

There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.

5.
Angiology ; : 33197231206430, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37820380

RESUMEN

We report a multicenter experience of open conversions (OC) for aortic endograft infections (AEI). We retrospectively analyzed all patients who underwent OC for AEI after endovascular aneurysm repair (EVAR), from 1997 to 2021 in 12 Italian centers. The endpoints were as follows: mortality (30-days, in-hospital), major postoperative complications. Follow-up data included: survival, aortic-related complications, infection persistence or reoccurrence. Fifty-eight patients (mean age: 73.8 ± 6.6 years) were included. Median time from EVAR to OC was 14 months (interquartile range 7-45). Thirty-five patients (60.3%) were symptomatic at presentation. Aortic reconstruction was anatomic in 32 patients (55.2%), extra-anatomic in 26 (44.8%). Thirty-day mortality was 31% (18/58). Six additional patients died after 30 days during the same hospitalization (in-hospital mortality: 41.4%). Most common post-operative complications included respiratory failure (38.6%) and renal insufficiency (35.1%). During 28.1 ± 4 months follow-up, 4 aneurysm-related deaths were recorded. Infection re-occurred in 29.4% of the patients. Estimated survival was 50% at 1 year, and 30% at 5 years, and was significantly lower for patients who underwent extra-anatomic reconstructions (37 vs 61% at 1 year, 16 vs 45% at 5 years; log-rank P = .021). OC for AEI is associated with high early mortality. The poor mid-term survival is influenced by aortic complications and infection re-occurrence.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...